Integrated Solutions Low Voltage Systems

Similar documents
Flameproof Manual Call Points Series MCP

UL HAZARDOUS LOCATIONS SERVICES

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Flameproof Manual Call Points Series MCP

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Indoor/outdoor resistance thermometer Model TR60

Electrical Installations Design, Selection, Erection and Inspection

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Explosion Proof Manual Call Points Series MCP

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Explosion Proof Combination Signal db (A) / 5 Joule

Flameproof Manual Call Points

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Guide for hazardous areas

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

ELECTRICAL EX EQUIPMENT

Main switch current K: with main switch (optional)

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

PANELBOARD PROTECTION ON A GLOBAL SCALE

Temperature Measurement Transmitters for field mounting

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

IECEx Certificate of Conformity

Dräger Polytron 5700 IR Detection of flammable gases and vapours

IECEx Certificate of Conformity

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Operating Manual Distribution box

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Explosion-proof Immersion Heater Type D-8660

Guide to Intrinsically Safe Portable Radios

TYPE APPROVAL CERTIFICATE

Fan Heaters Type VLEx

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Dräger Polytron 8000 Stationary gas detector (EC)

standards: standards:

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

your dust explosion protection experts

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Magnetostrictive sensor For bypass level indicators Model BLM

How Limit Switches Can Stop Machines from Going Boom

Overview of Hazardous Locations as They Relate to Solenoid Valves

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

OPTIBAR DP 7060 Supplementary Instructions

Dräger Polytron 8310 IR Detection of flammable gases and vapour

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

IECEx Certificate of Conformity

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Exp, pressurized systems

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Dräger Polytron 8700 IR Detection of flammable gases and vapors

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Drive systems for the chemical, oil and gas industry. Electric drives and systems

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

Dräger Polytron 5720 IR Toxic Gas Detection

Intrinsically Safe Solutions

DB4 Range - SPEAKERS - Up to 25 Watts

Manual Power relay SR853

Inductive slot sensor

DICTATOR Hold-Open Systems for Hazardous Areas

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Rosemount 752 Fieldbus Remote Indicator

Explosion Protected Panelboards D2Z Series

COMPACT FLAME CONTROLLER CFC 2000

Safety instructions VEGAPULS 64

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Technical Data. Dimensions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Technical Data. Dimensions

Fixed Gas Detection System/Meridian CERTIFICATION

Certificate of Compliance

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

OPTIWAVE X500 Supplementary Instructions

Dräger Polytron 5100 EC Detection of toxic gases and vapors

SET Installation and Operating Instructions. Level switch for one sensor

S T R I T T & P R I E B E I N C.

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Dräger Polytron 5720 IR Detection of carbon dioxide

Transcription:

Integrated Solutions Low Voltage Systems 612

Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx System CUBEx 8264 614 Lighting and Heating Panels made of Polyester Resin 8146 616 made of Light Metal CUBEx 8264 619 UPS Uninterrupted Power Supply Ex UPS CUBEx 8265 621 You will find further information on the Internet www.stahl.de Machine Control General Information Battery Boxes Battery Boxes 8316 Battery Container BC Ex p Technology Pressurized Apparatus General System Description 613

Overview Module technology Flameproof components are built into enclosures designed for increased safety Ex e. Explosion protection to IEC ATEX Marine certification with individual acceptance Explosion protection to Series 8146 in polyester resin Series 8150 in stainless steel Enclosures for modular combination Lighting and heating panels Comprehensive construction Easy handling Installation of flameproof modules (Ex de) fuses, miniature circuit-breakers, switches, contactors, motor protection relay, etc. Terminals in Ex e increased safety standard Rated current up to max. 160 A Mounting frame system for wall-mounting or free-standing with or without protection roof Operating flaps with inspection windows for simple external operation 01625e00 Flameproof enclosures Standard industrial equipment can be built into flameproof enclosures of Ex de construction, pressure with standing. Explosion protection to IEC ATEX Marine certification with individual acceptance Enclosure material Sheet-steel or stainless steel Enclosure for modular combination Standard motor starters Installation of standard electrical equipment fuses, switches, contactors, programmable controllers, regulators, etc. Axial load-through and inspection windows available Rated current up to max. 800 A, dependent on enclosure series Mounting frame system for wall-mounting or free-standing with or without protection roof Different installation system indirect entry using Ex e connection chambers indirect entry using Ex d cable glands or conduit material 02835E00 10295E00 CUBEx systems The straight walled CUBEx design of enclosure, are utilised for the building of control and distribution systems, control panels and terminal boxes. Installed industrial sparking electrical components are planned and wired in accordance to the customer s requirements. The enhanced features of the CUBEx system allows unique possibilities of D2D connections, therefore reducing the necessity for inter-connection chambers. Compact system D2D bushing Explosion protection to ATEX, IEC and NEC Marine certification with individual acceptance Can be used in Zone 1 and Zone 2 Zone 21 and Zone 22 7 basic enclosure sizes Available versions lighting and heating panel standard motor starters Optional: glass windows and cover hinges Entry method direct and indirect 614

Overview 615

Standard Lighting and Heat-Trace Panels Series 8146 Series 8146 06524E00 > Available versions With miniature circuit breaker, tripping characteristic C with residual current circuit breaker and overcurrent release, tripping characteristic B and C > Advantages Installation of miniature circuit breakers under hinged inspection window External operation of the breakers Switch setting visible at all times Operation under voltage Short delivery times WebCode 8146D ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 For use x x x x For use in x For use in x Technical Data Explosion protection Global (IECEx) Gas and dust IECEx PTB 06.0090 Ex d e ia ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db Europe (ATEX) Gas and dust PTB 01 ATEX 1024 E II 2 G Ex d e ia ib [ia Ga] mb q IIA, IIB, IIC T6, T5, T4 Gb Certifications and certificates Certificates E II 2 D Ex tb IIIA, IIIB, IIIC T80 C, T95 C, T130 C Db IP66 IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Taiwan (ITRI), Ukraine (TR), Belarus (TR) 415 / 240 V AC 80 A Rated voltage Rated current Degree of protection IP66 (EN 60529) Enclosure material glass fibre reinforced polyester resin, dark grey similar to RAL 7024 impact resistance ) 7 J surface resistance ( 10 9 Ω flame retardant acc. to IEC/EN 60695, UL 94, ASTM D635 616

Standard Lighting and Heat-Trace Panels Series 8146 Version Quantity Characteristics Layout No. Lighting panels with miniature circuit breaker, 1-pole, 16 A, wiring on terminal blocks 6 C 01 1 x M40, 6 x M25, 12 C 02 1 x M50, 12 x M25, 18 C 03 1 x M50, 18 x M25, 24 C 04 1 x M50, 24 x M25, Version Quantity Characteristics Layout No. Lighting panels with miniature circuit breaker, 1-pole, 16 A, mattress wiring 6 C 06 1 x M40, 6 x M25, 12 C 07 1 x M50, 12 x M25, Version Quantity Characteristics Layout No. Heat-trace panels with residual current circuit breaker and overcurrent release, 1-pole + N, 16 A /30 ma, wiring on terminal blocks 8 B 02 1 x M40, 8 x M25, 12 B 03 1 x M50, 12 x M25, 24 B 05 1 x M50, 24 x M25, 8 C 02 1 x M40, 8 x M25, 12 C 03 1 x M50, 12 x M25, 24 C 05 1 x M50, 24 x M25, Version Quantity Characteristics Layout No. Heat-trace panels with residual current circuit breaker and overcurrent release, 1-pole + N, 16 A / 30 ma, mattress wiring 8 B 07 1 x M40, 8 x M25, 8 C 07 1 x M40, 8 x M25, Cable entries Order number Art. no. 8146/5-ExV-01-06L16C1P-T 137111 8146/5-ExV-02-12L16C1P-T 137118 8146/5-ExV-03-18L16C1P-T 137124 8146/5-ExV-04-24L16C1P-T 137130 Cable entries Order number Art. no. 8146/5-ExV-06-06L16C1P-D 137135 8146/5-ExV-07-12L16C1P-D 137140 Cable entries Order number Art. no. 8146/5-ExV-02-08H16B1N-T 137146 8146/5-ExV-03-12H16B1N-T 137152 8146/5-ExV-05-24H16B1N-T 137157 8146/5-ExV-02-08H16C1N-T 137161 8146/5-ExV-03-12H16C1N-T 137164 8146/5-ExV-05-24H16C1N-T 137167 Cable entries Order number Art. no. 8146/5-ExV-07-08H16B1N-D 137171 8146/5-ExV-07-08H16C1N-D 137173 617

Standard Lighting and Heat-Trace Panels Series 8146 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations 10296E00 10297E00 10298E00 Layout 01 Layout 02 Layout 03 10302E00 10299E00 Layout 04 Layout 07 10300E00 10301E00 Layout 05 Layout 06 618

Lighting and Heating Panel CUBEx Series 8264/5-ExV > Enclosures with Ex d protection > Available versions: with MCB, characteristics C with MCB / ELCB, characteristics B resp. C > Advantage Short delivery time Series 8264/5-ExV 10229E00 WebCode 8264A ATEX / IECEx NEC 505 NEC 506 Class I Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 For use in x x x x For use in x Technical Data Explosion protection Global (IECEx) Gas and dust IECEx KEM 07.0051X Ex d e ia ib [ia Ga] mb IIB+H2 Gb T6... T4 Ex d e ia ib [ia Ga] mb IIB Gb T6... T4 Ex tb IIIC T80 C... T130 C Db Europe (ATEX) Gas and dust Certifications and certificates Certificates KEMA 01 ATEX 2145 X E II 2 G Ex d e ia ib [ia Ga] mb IIB+H2 Gb T6... T4 E II 2 G Ex d e ia ib [ia Ga] mb IIB Gb T6... T4 E II 2 D Ex tb IIIC T80 C... T130 C Db IECEx, ATEX, Brazil (INMETRO), China (China-Ex), India (PESO), Canada (cul), Kazakhstan (TR), Korea (KCs), Russia (TR), Taiwan (ITRI), USA (UL), Belarus (TR) 415 V / 240 V AC 100 A Rated voltage Rated current Degree of protection IP66 (EN 60529) Enclosure standard: Aluminium (saltwater-proof according to EN 13195-1) special: Stainless steel 619

Lighting and Heating Panel CUBEx Series 8264/5-ExV Version Quantity Characteristics Layout No. MCB 1-pole 16 A 12 C 01 1 x M50, 12 x M20 24 C 02 1 x M50, 24 x M20 Version Quantity Characteristics Layout No. MCB / ELCB 1-pole + N 16 A / 30 ma 12 B 01 1 x M50, 12 x M20 24 B 02 1 x M50, 24 x M20 12 C 01 1 x M50, 12 x M20 24 C 02 1 x M50, 24 x M20 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Cable entries Order number Art. no. 8264/5-ExV-01-12L16C1P-D 143210 8264/5-ExV-02-24L16C1P-D 143212 Cable entries Order number Art. no. 8264/5-ExV-01-12H16B1N-D 143214 8264/5-ExV-02-24H16B1N-D 143216 8264/5-ExV-01-12H16C1N-D 143217 8264/5-ExV-02-24H16C1N-D 143218 Layout 01 10046E00 Layout 02 10045E00 620

Ex UPS Series 8265 > Ex UPS Guard battery monitoring according to IEC/EN 60079 et seq. > Stable output voltage > Adjustable UPS time > Functional battery test > Capacity measurement of battery > Potential-free signal outputs Series 8265 12977E00 WebCode 8265B ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x Version Ex UPS Series 8265 Rated input voltage Output voltage Output voltage for UPS mode Battery Order number Art. no. PS 24 V DC 24 V DC 20.6 V DC 10 Ah 8265/55-612-111 206678 13 25 Ah 8265/55-613-111 206679 13 40 Ah 8265/55-614-111 206680 13 60 Ah 8265/55-615-111 206721 13 100... 250 V AC 24 V DC 20.6 V DC 10 Ah 8265/55-612-211 206722 13 25 Ah 8265/55-613-211 206723 13 further versions / designs on request Technical Data Explosion protection Global (IECEx) Gas and dust IECEx PTB 07.0029 (see 8265/5) Ex d e ia ib [ia Ga] IIC T6, T5, T4 Gb Ex tb IIIC T80 C, T95 C Db Europe (ATEX) Gas and dust PTB 06 ATEX 1077 (see 8265/5) E II 2 G Ex d e ia ib [ia Ga] IIC T6, T5, T4 Gb E II 2 D Ex tb IIIC T80 C, T95 C Db Certifications and certificates Certificates IECEx, ATEX Output voltage 24 V DC Output voltage for UPS mode 20.6 V DC Rated operational current 10 A Charging current 1.5 A per battery Closed-circuit current 5 μa UPS time 1 s... 6 h (via DIP switch) Potential-free signal output max. 100 ma Ambient temperature charging: 0... +40 C discharging: -20... +40 C Degree of protection IP66 (IP23 for the battery enclosure) 40 Ah 8265/55-614-211 206724 13 60 Ah 8265/55-615-211 206725 13 621

Ex UPS Series 8265 Project Guidelines The values in the table were determined, observing the criteria for reaching the full battery life. The autonomy time is reached at the end of the battery life. Order number 0050 50 W 24 V DC autonomy time in min. 5 10 60 (1 h) 120 (2 h) 180 (3 h) 300 (5 h) 8265/55-612-111-0050-... 24 V DC 8265/55-612-211-0050-... 100... 250 V AC 8265/55-613-111-0050-... 24 V DC 8265/55-613-211-0050-... 100... 250 V AC 8265/55-614-111-0050-... 24 V DC 8265/55-614-211-0050-... 100... 250 V AC 8265/55-615-111-0050-... 24 V DC 8265/55-615-211-0050-... 100... 250 V AC Set value 0005 0010 0060 0120 0180 0300 0100 100 W 24 V DC 0150 150 W 24 V DC 0200 200 W 24 V DC Order number autonomy time in min. 5 10 60 (1 h) 120 (2 h) 180 (3 h) 300 (5 h) 8265/55-612-111-0100-... 24 V DC 8265/55-612-211-0100-... 100... 250 V AC 8265/55-613-111-0100-... 24 V DC 8265/55-613-211-0100-... 100... 250 V AC 8265/55-614-111-0100-... 24 V DC 8265/55-614-211-0100-... 100... 250 V AC 8265/55-615-111-0100-... 24 V DC 8265/55-615-211-0100-... 100... 250 V AC Set value 0005 0010 0060 0120 0180 0300 Order number autonomy time in min. 5 10 60 (1 h) 120 (2 h) 180 (3 h) 300 (5 h) 8265/55-612-111-0150-... 24 V DC 8265/55-612-211-0150-... 100... 250 V AC 8265/55-613-111-0150-... 24 V DC 8265/55-613-211-0150-... 100... 250 V AC 8265/55-614-111-0150-... 24 V DC 8265/55-614-211-0150-... 100... 250 V AC 8265/55-615-111-0150-... 24 V DC 8265/55-615-211-0150-... 100... 250 V AC Set value 0005 0010 0060 0120 0180 0300 Order number autonomy time in min. 5 10 60 (1 h) 120 (2 h) 180 (3 h) 300 (5 h) 8265/55-612-111-0200-... 24 V DC 8265/55-612-211-0200-... 100... 250 V AC 8265/55-613-111-0200-... 24 V DC 8265/55-613-211-0200-... 100... 250 V AC 8265/55-614-111-0200-... 24 V DC 8265/55-614-211-0200-... 100... 250 V AC 8265/55-615-111-0200-... 24 V DC 8265/55-615-211-0200-... 100... 250 V AC Set value 0005 0010 0060 0120 0180 0300 The battery life is reached according to IEC 896 Part 2. The battery life is reduced substantially, depending on load. The autonomy time is not reached. 622

Ex UPS Series 8265 Description Ex UPS Guard The R. STAHL UPS modular system offers tailor-made and economical UPS solutions for hazardous areas. According to the ATEX directives and common standards, special requirements apply to the charging of batteries in the hazardous area. To ensure explosion protection, the parameters for operation of batteries and battery chargers must be monitored - in addition to the settings on the charger. The new Ex UPS Guard checks the function of the charger and of the batteries according to the ATEX directive. On the market, this unique function provides the safety of the installation. 12974E00 Enclosures used Ex d enclosure Series 8265 with coated surface (RAL7035) Ex e enclosure Series 8146 Systems mounted on frame Series 8298 made of galvanized steel Typical dimensions (H x W x D) / weights 8265/55-612-... 8265/55-613-... 8265/55-614-... 8265/55-615-... 1246 x 396 x 300 mm / weight: approx. 65 kg 1578 x 396 x 300 mm / weight: approx. 84 kg 1578 x 396 x 300 mm / weight: approx. 96 kg 1578 x 396 x 300 mm / weight: approx. 108 kg 623