Novenco jet fans AUO / ARO / AUT / ART / CGF January 2010
Product facts Product Novenco jet fans are produced in unidirectional (AU_ and CGF) and reversible (AR_) versions. AUT/ART circular Basic jet fans (Novax) AUO/ARO oval Design jet fans (Novax) CGF flat jet fans Application The jet fans are used for ventilation of car parks and large spaces where polluted air needs to be removed effectively. They are often part of concepts for fire fighting and hot smoke removal in connection with fires. The operating temperature range is as standard -20 to +40 C. Max. temperature range is from +40 to +120 C. Hot smoke versions withstand 400 C for up to two hours. Product range Novenco jet fans are manufactured in different sizes. AUT/ART AUO/ARO CGF Rotor diameters Construction Diameters [mm] Ø400 Ø290, Ø380, Ø500 Ø500 All the jet fan types move air using the impulse principle. AUT, ART, AUO and ARO are long tubes with cones in the ends. AUO and ARO have silencers in the ends and oval outer fan casings. CGF are flat fans with rotors mounted centrally and perpendicular to the inlet. The AUO have wire guards on the inlet sides and ARO have deflectors. Both types are fitted with external deflectors on the outlet side. AUT and ART have wire guards on both sides and are provided with aerodynamic integrated deflectors. CGF have deflectors in the outlet and wire guards in the inlet. The fans are delivered with suspension brackets for mounting to ceilings or onto walls. CGF is intended for ceiling mounting only. Motors The motors are two-speed 3x400 V, 50 Hz for direct start. Motor protection: Min. IP55 in accordance with IEC 34-5 Insulation class: F or H depending on temperature protection Motor flanges: B14 in accordance with IEC 34-7 and B30 for CGF 500 Electric switches AUO/ARO jet fans have either electric isolating switches integrated in the fan casing or internal terminal boxes. AUT/ART have all external terminal boxes. CGF have internal terminal boxes. Rotors All Novenco jet fans employ direct coupled motors. AUT, ART, AUO and ARO have Novenco Novax rotors consisting of two hub discs with cavities, in which four blades are mounted in preset positions. CGF have Novenco centrifugal wheels with direct coupled motors. Silencers The AUO/ARO fans are fitted with silencers in both ends of the fan casing. Cones designed for minimum pressure loss are mounted on the inlet and outlet sides. The CGF fans are designed with focus on sound attenuation. Materials Blades: Aluminium alloy Hub shells (Novax): Steel sheets Fan tubes (Novax): Rolled steel tube in 3 mm sheet Fan housing (CGF): AluZink Wire guard (Novax): Stainless steel Deflector (Novax): Galvanised steel and aluminium Deflector (CGF): Galvanised steel Suspension: Hot-galvanised 4 mm steel sheet Outer casing for fan housing and silencers (AUO/ARO): 0.75 mm sheet in AluZink Inside tube for silencers (AUO/ ARO): Perforated pregalvanised sheet steel Sound attenuating material (AUO/ARO): Fireproof and moisture resistant Cones (AUO/ARO): Galvanised steel 2 Novenco jet fans
Contents Description 4 Dimensions and technical specifications 5 Important This document is provided As is. Novenco reserves the right to changes without notice due to continuous product development. The fan is designed for continuous operation. The following kinds of operation may cause fatigue break in the impeller and endanger people. Operation in stall area Operation with pulsating counter pressure - called pump mode Operation with repeated starting and stopping If in doubt Novenco should be contacted to assess the suitability of the fan. Copyright (c) 2002 2010, Novenco A/S. All rights reserved. Patents and trademarks Novenco is a registered trademark of Novenco A/S. The Novenco Novax Basic jet fans are patent pending. Pat. no. PA200900058. The designs of Novenco Novax Basic and Novenco CGF jet fans are protected and the property of Novenco A/S. Other trademarks appearing in this document are the property of their respective owners. Quality and environment Novenco is certified in accordance with ISO 9001 and 14001. MU 14264 0110 Novenco jet fans 3
Description Product description Fan types Jet fans are produced in unidirectional and reversible versions with or without silencers. Design jet fans with especially low sound levels are called AUO and ARO. They are available with rotor diameters Ø290, Ø380 or Ø500 mm. Basic jet fans are called AUT and ART. They are only available with rotor diameter Ø400. CGF jet fans have low built-in height and low sound levels. They are only available with rotor diameter Ø500. Fan housings The fan housings of the tube-shaped jet fans are rolled and welded steel tubes in 3 mm sheet. The Design jet fans AUO and ARO have external oval outer casings of AluZink sheet. Safety switches The AUO/ARO are delivered with or without safety switches mounted in the terminal boxes. The terminal boxes are internal and integrated in the fan casing. The AUT/ART all have external terminal boxes. The CGF has internal terminal boxes. Mounting The fans are fitted with brackets for ceiling or wall mounting. Fans type CGF are only for mounting in ceilings. Distance requirements for Novenco jet fans to beams and the height of these are relatively small. Thus on inlet sides there must be a minimum of 0.5 m to beams and on outlet sides a minimum of 2.0 m. Maximum beam height is 0.4 m on outlet sides in installations that are just within the minimum requirements. Classifications The fans meet requirements for operation in unheated, low corrosive environments according to DS/ EN ISO 12944-2, corrosion category C3. Standard is - 20 to +40 C. Deflector on Novenco ARO Design jet fan The CGF fan housings are in 2 mm sheet and assembled with pop rivets. Fans for fire fighting and hot smoke removal are CEcertified and approved in accordance with EN12101-3 for operating in the following temperature ranges. F200 200 C F300 300 C 1 F400 400 C 1 hours x 2 hours x x x Approved temperature ranges 1. Jet fans type CGF are approved up to and including F300. Underside of Novenco CGF jet fan Motors These are 3x400 V, 50 Hz with direct start. Motor protection is IP 55 in accordance with IEC 34-5. Insulation is class F or H. Inside a Novenco AUO Design jet fan Balancing of rotor units is in accordance with VDI 2060, ISO 1940, 1-1986 class Q 6.3. 4 Novenco jet fans
Type / Size Serial / Order No. Blades Marking NOVENCO Ydernæs - DK - 4700 Næstved, Denmark Type Angle Max. RPM by 20 C Max. frequency (Hz) Production Year Type / Size Serial / Order No. Blades Marking Material NOVENCO Ydernæs - DK - 4700 Næstved, Denmark Type Angle Max. RPM by 20 C Max. frequency (Hz) Production Year Dimensions and technical specifications Dimensions D B E 4xØR AUT/ART C A A [mm] B [mm] C [mm] D [mm] E [mm] ØR Total weight [kg] AUT/ART 400 854 522 423 779 470 14 63 D B E 4xØR AUO motor Material C A D B E 4xØR ARO motor C A A [mm] B [mm] C [mm] D [mm] E [mm] ØR Total weight [kg] AUO 290 2570 598 320 506 560 14 80 AUO 380 2672 758 420 506 720 14 110 AUO 500 2606 870 540 600 830 14 160 ARO 290 2823 598 320 506 560 14 80 ARO 380 2918 758 420 506 720 14 110 ARO 500 2854 870 540 600 830 14 160 CGF C D B E A A [mm] B [mm] C [mm] D [mm] E [mm] Total weight [kg] CGF 500 1296.5 810.2 259.9 73.5 27 75 Novenco jet fans 5
Specifications Sizes 400 Sizes 290 Sizes 380 Sizes 500 AUT ART 1 AUO ARO 1 AUO ARO 1 AUO ARO 1 CGF Volume flow [m 3 /s] 1.1 / 2.3 1.0 / 2.2 0.5 / 1 0.5 / 0.9 1.0 / 2.0 1.0 / 1.9 2.2 / 4.3 2.2 / 4.3 0.8 / 1.6 Air speed [m/s] 9 / 18 8 / 18 9 / 18 9 / 17 11 / 22 11 / 22 11 / 22 11 / 22 14 / 27 Thrust [N] 2 14 / 53 13 / 50 5 / 21 4 / 15 15 / 57 15 / 52 27 / 105 28 / 111 12 / 48 Number of poles 2 / 4 8 / 4 Voltage 3x400 V, 50 Hz Motor consumption [kw] 0.25 / 1.1 0.3 / 1.3 0.1 / 0.5 0.1 / 0.5 0.25 / 1.1 0.3 / 1.3 0.5 / 2.2 0.5 / 2.2 0.39 / 0.98 Sound pressure [db(a)] 3 54 / 72 56 / 75 35 / 46 35 / 47 39 / 52 42 / 56 45 / 59 49 / 64 61 / 75 1. Data for reversible fans is given for air direction blade motor. 2. Calculated from the outlet air speed. 3. Calculated sound pressure levels are at 3 m and 45 free field from the fan found in a laboratory. 6 Novenco jet fans
MU 14264 0110 Novenco develops and manufactures ventilation and fire fighting systems that are marketed and distributed world-wide through subsidiaries and agents. The company was founded in Denmark 1947 and has become one of the world-leading suppliers. Novenco symbolises quality and environmentally friendly products. The company is certified according to ISO 9001 and ISO 14001. The headquarters of Novenco is located in Naestved, Denmark. Novenco, Hi-Pres, XFlow and ZerAx are registered trademarks of Novenco. Read more about Novenco on the Internet. Novenco A/S Industrivej 22 DK-4700 Naestved Denmark Tel. +45 70 12 42 22 Fax +45 55 75 65 50 www.novenco-group.com