Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Similar documents
Jet fans JET FANS FANS FOR CAR PARK VENTILATION AUO / ARO / AUP / ARP AUZ/ AUT / ART / CGF

TUNNEL FANS STANDARD AND HOT SMOKE

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

AZN ATEX INSTALLATION AND MAINTENANCE

ACN SMOKE INSTALLATION AND MAINTENANCE

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

English CNA-CNB. Centrifugal fans Installation and maintenance

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

AXIAL & JET FANS FOR TUNNEL VENTILATION

UNIJET CAR PARK VENTILATION SYSTEM

Climaster ZerAx. Air Handling Units. Eco-design requirements

SMOKE CONTROL - NEW DIRECTIONS

Systemair product news - Fans NEWS

Company History Locations Product range References

Hi-Pres Cooling Products Catalogue. Product Catalogue

Transformer oil coolers BETA & CETA

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

POWERPLUS SPP Product Brochure

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Unit heater with accessories

Hi-Pres Cooling Products Catalogue

Novenco Air Handling Units

Units for suspended ceilings

Smoke extract fan SMHA HATCH

ROOFMASTER STEF-HT ROOF FAN

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

JM Aerofoil Fans Bulletin JMA60-05

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Centrifugal Blower. Backward/Aerofoil Curved.

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

Axial flow fan AXICO ANTI-STALL

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Technical data Chimney fans, controllers and accessories in systems for gas fireplaces, stoves and single non-modulating gas boilers

Car Park Ventilation 1

42AM. Air heaters PRODUCT SELECTION DATA

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

When you think safety think Systemair

Atrium H & C Loggia. Mounting instruction. Delivery control 2 View 2 Mounting 3 Water connection 4 False ceiling adaptation 5

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Centrifugal Fans, Non-Overloading, Backward Inclined

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

EHH SERIES DRAW THROUGH FAN COILS CFM

PRODUCT REVIEW. Low Pressure Blowers. Medium Pressure Blowers. High Pressure Blowers. Side Channel Blowers. Conveying Blowers FD RD F

Tunnel Axial Flow Fan

CR A-F-A-E-HQQE 3x400/ HZ

CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

WOLF VENTILATION SYSTEM PRICE LIST

CLIMASTER ZCF AIR HANDLING UNITS

CR A-F-A-E-HQQE 3x400/ HZ

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

Axial fans The right fan for every house

CRN A-F-G-E-HQQE 3x400D 50 HZ

ABOUT US WHO WE ARE? TIME TUNNEL STEPS TO EXCELLENCE FACTS and FIGURES NEW LOGO and SLOGAN CERTIFICATES

CR20-07 A-F-A-E-HQQE 3x400/ HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Evaporators 60HZ version

A. Codes and Standards that are Standard at the University:

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

Gas-fired unit heaters for indoor installation

CONDOR. Supply air ceiling QUICK FACTS

Pumps Mixers Aeration Controls Services SCANPUMP PROCESS PUMPS, BE SERIES. NO-COMPROMISE PUMPING.

KITCHEN EXTRACTORS K Series

TopVent Design Handbook

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

PFS Single stage axial fan The axial fan for modern boiler plants

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Climaster ZerAx. Eco-designkrav. Climaster ZerAx type ZCN-M guide GB

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Lenntech. Tel Fax bar. Multistage Pumps.

Technical data. Chimney fans, controls and accessories for gas fireplaces, stoves and single non-modulating gas boilers G A S

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Units for suspended cei lings

Domestic & Commercial Fans

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Novenco Air Handling Units. Climaster ZCP June 2005

Ceiling diffusers. Type DLQL

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Transcription:

Novenco jet fans AUO / ARO / AUT / ART / CGF January 2010

Product facts Product Novenco jet fans are produced in unidirectional (AU_ and CGF) and reversible (AR_) versions. AUT/ART circular Basic jet fans (Novax) AUO/ARO oval Design jet fans (Novax) CGF flat jet fans Application The jet fans are used for ventilation of car parks and large spaces where polluted air needs to be removed effectively. They are often part of concepts for fire fighting and hot smoke removal in connection with fires. The operating temperature range is as standard -20 to +40 C. Max. temperature range is from +40 to +120 C. Hot smoke versions withstand 400 C for up to two hours. Product range Novenco jet fans are manufactured in different sizes. AUT/ART AUO/ARO CGF Rotor diameters Construction Diameters [mm] Ø400 Ø290, Ø380, Ø500 Ø500 All the jet fan types move air using the impulse principle. AUT, ART, AUO and ARO are long tubes with cones in the ends. AUO and ARO have silencers in the ends and oval outer fan casings. CGF are flat fans with rotors mounted centrally and perpendicular to the inlet. The AUO have wire guards on the inlet sides and ARO have deflectors. Both types are fitted with external deflectors on the outlet side. AUT and ART have wire guards on both sides and are provided with aerodynamic integrated deflectors. CGF have deflectors in the outlet and wire guards in the inlet. The fans are delivered with suspension brackets for mounting to ceilings or onto walls. CGF is intended for ceiling mounting only. Motors The motors are two-speed 3x400 V, 50 Hz for direct start. Motor protection: Min. IP55 in accordance with IEC 34-5 Insulation class: F or H depending on temperature protection Motor flanges: B14 in accordance with IEC 34-7 and B30 for CGF 500 Electric switches AUO/ARO jet fans have either electric isolating switches integrated in the fan casing or internal terminal boxes. AUT/ART have all external terminal boxes. CGF have internal terminal boxes. Rotors All Novenco jet fans employ direct coupled motors. AUT, ART, AUO and ARO have Novenco Novax rotors consisting of two hub discs with cavities, in which four blades are mounted in preset positions. CGF have Novenco centrifugal wheels with direct coupled motors. Silencers The AUO/ARO fans are fitted with silencers in both ends of the fan casing. Cones designed for minimum pressure loss are mounted on the inlet and outlet sides. The CGF fans are designed with focus on sound attenuation. Materials Blades: Aluminium alloy Hub shells (Novax): Steel sheets Fan tubes (Novax): Rolled steel tube in 3 mm sheet Fan housing (CGF): AluZink Wire guard (Novax): Stainless steel Deflector (Novax): Galvanised steel and aluminium Deflector (CGF): Galvanised steel Suspension: Hot-galvanised 4 mm steel sheet Outer casing for fan housing and silencers (AUO/ARO): 0.75 mm sheet in AluZink Inside tube for silencers (AUO/ ARO): Perforated pregalvanised sheet steel Sound attenuating material (AUO/ARO): Fireproof and moisture resistant Cones (AUO/ARO): Galvanised steel 2 Novenco jet fans

Contents Description 4 Dimensions and technical specifications 5 Important This document is provided As is. Novenco reserves the right to changes without notice due to continuous product development. The fan is designed for continuous operation. The following kinds of operation may cause fatigue break in the impeller and endanger people. Operation in stall area Operation with pulsating counter pressure - called pump mode Operation with repeated starting and stopping If in doubt Novenco should be contacted to assess the suitability of the fan. Copyright (c) 2002 2010, Novenco A/S. All rights reserved. Patents and trademarks Novenco is a registered trademark of Novenco A/S. The Novenco Novax Basic jet fans are patent pending. Pat. no. PA200900058. The designs of Novenco Novax Basic and Novenco CGF jet fans are protected and the property of Novenco A/S. Other trademarks appearing in this document are the property of their respective owners. Quality and environment Novenco is certified in accordance with ISO 9001 and 14001. MU 14264 0110 Novenco jet fans 3

Description Product description Fan types Jet fans are produced in unidirectional and reversible versions with or without silencers. Design jet fans with especially low sound levels are called AUO and ARO. They are available with rotor diameters Ø290, Ø380 or Ø500 mm. Basic jet fans are called AUT and ART. They are only available with rotor diameter Ø400. CGF jet fans have low built-in height and low sound levels. They are only available with rotor diameter Ø500. Fan housings The fan housings of the tube-shaped jet fans are rolled and welded steel tubes in 3 mm sheet. The Design jet fans AUO and ARO have external oval outer casings of AluZink sheet. Safety switches The AUO/ARO are delivered with or without safety switches mounted in the terminal boxes. The terminal boxes are internal and integrated in the fan casing. The AUT/ART all have external terminal boxes. The CGF has internal terminal boxes. Mounting The fans are fitted with brackets for ceiling or wall mounting. Fans type CGF are only for mounting in ceilings. Distance requirements for Novenco jet fans to beams and the height of these are relatively small. Thus on inlet sides there must be a minimum of 0.5 m to beams and on outlet sides a minimum of 2.0 m. Maximum beam height is 0.4 m on outlet sides in installations that are just within the minimum requirements. Classifications The fans meet requirements for operation in unheated, low corrosive environments according to DS/ EN ISO 12944-2, corrosion category C3. Standard is - 20 to +40 C. Deflector on Novenco ARO Design jet fan The CGF fan housings are in 2 mm sheet and assembled with pop rivets. Fans for fire fighting and hot smoke removal are CEcertified and approved in accordance with EN12101-3 for operating in the following temperature ranges. F200 200 C F300 300 C 1 F400 400 C 1 hours x 2 hours x x x Approved temperature ranges 1. Jet fans type CGF are approved up to and including F300. Underside of Novenco CGF jet fan Motors These are 3x400 V, 50 Hz with direct start. Motor protection is IP 55 in accordance with IEC 34-5. Insulation is class F or H. Inside a Novenco AUO Design jet fan Balancing of rotor units is in accordance with VDI 2060, ISO 1940, 1-1986 class Q 6.3. 4 Novenco jet fans

Type / Size Serial / Order No. Blades Marking NOVENCO Ydernæs - DK - 4700 Næstved, Denmark Type Angle Max. RPM by 20 C Max. frequency (Hz) Production Year Type / Size Serial / Order No. Blades Marking Material NOVENCO Ydernæs - DK - 4700 Næstved, Denmark Type Angle Max. RPM by 20 C Max. frequency (Hz) Production Year Dimensions and technical specifications Dimensions D B E 4xØR AUT/ART C A A [mm] B [mm] C [mm] D [mm] E [mm] ØR Total weight [kg] AUT/ART 400 854 522 423 779 470 14 63 D B E 4xØR AUO motor Material C A D B E 4xØR ARO motor C A A [mm] B [mm] C [mm] D [mm] E [mm] ØR Total weight [kg] AUO 290 2570 598 320 506 560 14 80 AUO 380 2672 758 420 506 720 14 110 AUO 500 2606 870 540 600 830 14 160 ARO 290 2823 598 320 506 560 14 80 ARO 380 2918 758 420 506 720 14 110 ARO 500 2854 870 540 600 830 14 160 CGF C D B E A A [mm] B [mm] C [mm] D [mm] E [mm] Total weight [kg] CGF 500 1296.5 810.2 259.9 73.5 27 75 Novenco jet fans 5

Specifications Sizes 400 Sizes 290 Sizes 380 Sizes 500 AUT ART 1 AUO ARO 1 AUO ARO 1 AUO ARO 1 CGF Volume flow [m 3 /s] 1.1 / 2.3 1.0 / 2.2 0.5 / 1 0.5 / 0.9 1.0 / 2.0 1.0 / 1.9 2.2 / 4.3 2.2 / 4.3 0.8 / 1.6 Air speed [m/s] 9 / 18 8 / 18 9 / 18 9 / 17 11 / 22 11 / 22 11 / 22 11 / 22 14 / 27 Thrust [N] 2 14 / 53 13 / 50 5 / 21 4 / 15 15 / 57 15 / 52 27 / 105 28 / 111 12 / 48 Number of poles 2 / 4 8 / 4 Voltage 3x400 V, 50 Hz Motor consumption [kw] 0.25 / 1.1 0.3 / 1.3 0.1 / 0.5 0.1 / 0.5 0.25 / 1.1 0.3 / 1.3 0.5 / 2.2 0.5 / 2.2 0.39 / 0.98 Sound pressure [db(a)] 3 54 / 72 56 / 75 35 / 46 35 / 47 39 / 52 42 / 56 45 / 59 49 / 64 61 / 75 1. Data for reversible fans is given for air direction blade motor. 2. Calculated from the outlet air speed. 3. Calculated sound pressure levels are at 3 m and 45 free field from the fan found in a laboratory. 6 Novenco jet fans

MU 14264 0110 Novenco develops and manufactures ventilation and fire fighting systems that are marketed and distributed world-wide through subsidiaries and agents. The company was founded in Denmark 1947 and has become one of the world-leading suppliers. Novenco symbolises quality and environmentally friendly products. The company is certified according to ISO 9001 and ISO 14001. The headquarters of Novenco is located in Naestved, Denmark. Novenco, Hi-Pres, XFlow and ZerAx are registered trademarks of Novenco. Read more about Novenco on the Internet. Novenco A/S Industrivej 22 DK-4700 Naestved Denmark Tel. +45 70 12 42 22 Fax +45 55 75 65 50 www.novenco-group.com