Data acquisition for the ILC

Similar documents
CALICE: status of a data acquisition system for the ILC calorimeters. Valeria Bartsch, on behalf of CALICE-UK Collaboration

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

LCTPC Setup at the DESY Testbeam. AWLC 14, Fermilab , R. Diener, DESY

Highlights and Visions of LC Detectors

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

Status of Texas active target data manager development. S. Ahn, G.V. Rogachev, E. Koshchiy, J. Hooker, and S. Upadhiajula

The SLAC Detector R&D Program

Micromegas detectors for the upgrade of the ATLAS Muon Spectrometer

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

arxiv: v1 [physics.ins-det] 20 Mar 2017

THE ALICE EXPERIMENT CONTROL SYSTEM

STATUS OF THE LHC EXPERIMENTS.

CMS, In Brief. Bill Gabella Vanderbilt Quarknet session, July 20, 2015 (disgracefully borrowing from Will Johns)

System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS

Status Report about the TPC Detector and Module at CEPC

Towards a Detector Control System for the ATLAS Pixeldetector

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. Status of CMS Commissioning

Expected needs in Electronics for the CERN Experiments. 5 October 2015

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

US CMS Trigger. DOE-NSF Review Wesley H. Smith, U. Wisconsin CMS Trigger Project Manager April 9, 2003

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

The LHCb Outer Tracker: Production & Ageing studies

The Technical Infrastructure Group supplies experimental activities at NBI with technical

Compact Muon Solenoid Detector (CMS) & The Token Bit Manager (TBM) Alex Armstrong & Wyatt Behn Mentor: Dr. Andrew Ivanov

A Beam radiation monitor for the SVT based on CVD diamond sensors!

arxiv: v1 [physics.ins-det] 2 Oct 2013

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

PERSPECTIVES OF MICRO-PATTERN GASEOUS DETECTOR TECHNOLOGIES FOR FUTURE PHYSICS PROJECTS

PoS(ICHEP2012)516. The status of the CMS pixel upgrade detector

2 Overview of the Pixel Detector Control System

TRACI, A MULTIPURPOSE CO 2 COOLING SYSTEM FOR R&D

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Temperature Data Logging

Surface Concept Product Catalog 2014

R&D of GEM detector high rate for CBM Experiment at FAIR Muon Chamber R&D in India

PERSPECTIVES OF MICRO-PATTERN GASEOUS DETECTOR TECHNOLOGIES FOR FUTURE PHYSICS PROJECTS 1

MC-PAD FP7 Marie Curie Initial Training Network on Particle Detectors. Christian J. Schmidt, 4 th NoRHDia Workshop

Detectors Plans for LS1

L0 TRIGGER ELECTRONICS FOR THE SETUP IN RUN MARCH 2017

The TOTEM Detector at LHC

Learning from High Energy Physics Data Acquisition Systems Is this the future of Photon Science DAQ?

Engineering Specification

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

Roadmap for ILC Detector R&D Test Beams

CMS inner detector: the Run 1 to Run 2 transition and first experience of Run 2

US CMS Trigger. DOE-NSF Review. Wesley H. Smith, U. Wisconsin CMS Trigger Project Manager February 14, 2007

Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter

Testing strategy and timeline of E-det 80k. Christian Koffmane for the MPG HLL team

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

ATLAS Diamond Beam Conditions Monitor

The New DUSTTRAK II and DRX Aerosol Monitors

GEM detectors activity at the Laboratori Nazionali di Frascati of INFN

Technical Specification and Operating Procedure PILATUS 300K

The ATLAS detector: status of the construction and installation a year before the first p-p collisions at the LHC Collider

Content INTELLIGENT VEHICLE MONITORING SYSTEM CENTRAL MONITORING SOFTWARE MOBILE CENTRAL MONITORING SOFTWARE PLAY BACK SOFTWARE F-1

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

Substation Monitoring System

The New DUSTTRAK II and DRX Aerosol Monitors

TacBio: A UV-based Biological Aerosol Detector. TacBio Overview Page 1

Product data sheet Palas Promo 2000

PMD2 Plus. Enhanced Walk-Through Multi-Zone Metal Detector. new. Threat Detection through Electromagnetics. generation

Available online at ScienceDirect. Physics Procedia 67 (2015 )

ND280 Construction Status Report

October Network of Companies

HALT/ HASS Testing of ATLAS Pixel Detector Modules OU REU JESSIE JOHNSON ADVISOR: DR. STUPAK GRADUATE STUDENTS: JOSEPH LAMBERT & HYOYEON LEE

arxiv: v1 [physics.ins-det] 27 Jan 2012

Performance Analysis of the AD Detector Control System in the ALICE Experiment

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

US CMS Trigger LPC Meeting. Wesley H. Smith, U. Wisconsin CMS Trigger Project Manager February 17, 2006

Status of the LHCb Detector. LHCC Open Session CERN, 27 November 2002 Werner Witzeling on behalf of the LHCb Collaboration

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Sentry G3 Machinery Protection Monitor

ProStar 325 UV-Vis Detector

MICROPOINT to MICROPOINT II UPGRADE

Continuous, real-time detection, alarming and analysis of partial discharge events

CERN GIF ++ : A new irradiation facility to test large-area particle detectors for the high-luminosity LHC program

LHCb Rich Detectors Control and High Voltage Systems

! "! # $ % & ' ( % % % % ( ( ( % & % ) *

OLIP SYSTEMS INC. OLIP Intelligent Wireless Condition Monitoring System

The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

PMD2 Plus series. Enhanced Walk-Through Metal Detectors. NEW. Threat Detection through Electromagnetics GENERATION

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Status of the PRad Experiment (E )

Monitoring Solutions

RECENT DEVELOPMENTS ON MICRO-PATTERN GASEOUS DETECTORS TECHNOLOGY

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

Di-440 The Modular Analyser

Quality Control of the CMS Tracker and ECAL Installed Optical Cabling

CRUSH: Cognitive Radio Universal Software Hardware

Application of Control System Studio for the NOνA Detector Control System.

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

POWER & ENERGY METERS BEAM PROFILING THZ MEASUREMENT COMPANY PROFILE

Tracking Detectors 2 silicon for HEP

Industrial Ray DR/ ICT integration inspection testing system. (2) Software and Testing

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Transcription:

Data acquisition for the ILC Matthew Wing (UCL / DESY) Introduction DAQ system for the ILC Ongoing common DAQ work, AIDA-2020 Summary and outlook British Museum 138th ILC@DESY General Project Meeting 23 September 2016, DESY

Introduction A DAQ system needs to pass data to and from the detector to some off-detector system DAQ systems need to cater for the following needs in high energy particle physics: Cope with high bandwidth data May have to pick out (trigger on) interesting or spectacular events Collect data with 100% (!) efficiency Work for a long time without (!) fault Integrate a system of many different components Cope with upgrades of accelerators and detectors or other very different running conditions. Other issues within HEP HEP has been a driving force for technology the collection and transfer of data of such high volume and rate was not common at the advent of collider physics. Each accelerator / experiment / detector had a bespoke system to cater for its needs. With industry advances and more common high-speed data transfer, have the opportunity to use commercial off-the-shelf equipment to reduce costs, development time and risk. 2

DAQ considerations for the ILC The ILC s much lower rate and no-trigger operation compared to the LHC make it seem simple(r). However, there are a number of challenges: Highly granular detectors leads to an unprecedented number of channels - Robust control and monitoring is essential - Significant data compression at detector electronics level - Power consumption needs to be low The beam structure is very different to recent colliders with a 1 ms train ~300 nsspaced bunches, all 5 times per second. This is all very different when running beam tests. ILC mode Test-beam mode 3

Original CALICE DAQ architecture During the development of first CALICE (EUDET) technical prototypes, UK groups were developing the DAQ system*: Basic R&D into data acquisition systems for itself and for calorimeters at the ILC. Developed a conceptual design of a DAQ system for calorimetry at the ILC (even though far off). Develop a system using industrial standards and advances: flexible, high-speed serial links, scalable, using commercial off-the-shelf components. Deliver DAQ system for prototype calorimeters. DAQ system could be applicable for final system of other detector systems. Serves as a good example of an overall DAQ system design and much of the design is still in use today. It addresses the boundary between on- and off-detector and detector-specific and generic. It is also an integrated hardware and software solution. *M. Wing et al., A proposed DAQ system for a calorimeter at the International Linear Collider, LC note, LC-DET-2006-008. M.J. Goodrick et al., Development of a modular and scalable data acquisition system for calorimeters at a linear collider, JINST 6 (2011) P10011. 4

Original CALICE DAQ architecture Detector Unit: ASICs DIF: Detector InterFace connects generic DAQ and services LDA: Link/Data Aggregator fansout/in DIFs and drives links to ODR ODR: Off-Detector Receiver is PC interface CCC: Clock and Control Card fansout to ODRs (or LDAs) Control PC: Using DOOCS (software) DAQ$PC ODR Storage DAQ$PC ODR Control$ PC$ (DOOCS) CCC LDA LDA DIF DIF DIF DIF Detector Unit Detector Unit Detector Unit Detector Unit 5

Ongoing common DAQ work, AIDA-2020 Principles, motivation, boundary conditions As part of the AIDA-2020 programme, we aim to provide a common DAQ system. We are not designing a prototype DAQ system for a Linear Collider detector. We cannot develop a fully integrated hardware / software solution from scratch. Priority is to ease running of detectors in a beam test (a service). Should allow more physics and technical understanding to be extracted. Understand performance of detector and / or validation of reconstruction algorithms for individual and multiple detectors. Clear links with other parts of the collaboration on software, calorimetry and, indeed, all detectors under development. In principle (ideally) we should be as inclusive as possible, developing solutions which are useable by all and providing common frameworks and tools. The developments could be used by other (non-lc) detectors too. As a by-product, learning about a future Linear Collider DAQ and some of its challenges. Will discuss here the common solutions being worked on. 6

Needs of common DAQ Beam tests envisaged: More than one calorimeter, e.g. an electromagnetic and a hadronic calorimeter large number of physics, technical and integration issues to be addressed. TPC and silicon reference tracker momentum resolution of TPC. Calorimeter plus tracking position resolution of calorimeter, uniformity, particle flow. Forward beam-pipe calorimeter (FCAL) plus tracking position resolution of FCAL. Priority is to ease running of detectors in a beam test (a service) to allow more physics and technical understanding to be extracted. 7

CALICE structure Individual DAQ hardware (and software) for each calorimeter based on UK design. PC data CALICE DAQ Structure Not realized yet TLU? CALICE Master CCC Clock, start/stop, validation, busy tracker etc. Si CCC PC Sc CCC SDHCAL SDCC data LDA / GDCC WingLDA / MiniLDA DCC HDMI Ethernet USB PC RPI Si DIF Sc DIF SDHCAL DIF data SKIROC SPIROC HARDROC 8 Taikan Suehara, AIDA-2020 kickoff meeting, 3 Jun. 2015 page 3

CALICE DAQ structure 9 T. Suehara and K. Krüger, AIDA-CALICE DAQ interface, AIDA-2020-NOTE-2016-006

TPC DAQ TPC uses modified ALTRO system from ALICE TPC (Lund) Trigger: External trigger Using NIM electronics TLU (never used) Data transferred from chips via an optical link to PC Sampling frequency is 5 / 10 / 20 / 40 MHz. LCTPC has 10k channels Integration with EUDAQ and TLU needed Opportunity to re-work DAQ given need to integrate with Si tracker, based on Kpix D. Tsionou 10

AIDA-2020: interface, synchronisation and control of multiple-detector systems Distribution of timing and synchronisation signals is key to any central DAQ system to allow data from different detectors to be correlated. Synchronisation of different detectors with very different integration times, e.g. vertex detector and calorimeter. Signals need to correspond to same events! Interfaces specified for trigger logic unit (TLU) used for EUDET/AIDA beam telescope and clock and control card (CCC) used by CALICE. - TLU distributes trigger signal and number and data is read out belonging to this trigger. Does not work for auto-triggered systems. - CCC distributes a clock and START and STOP and data readout during that acquisition cycle. Need to agree on a clock frequency; need to define an event. Compatibility between TLU and CCC is crucial. TLU undergoing development for this. The basic interface, synchronisation and control definitions have been documented.* Provide TLUs for combined beam tests and laboratory set-ups, integrate to common DAQ and provide expert support. * D. Cussans, Hardware and software interface specification for AIDA-2020 common beam tests, AIDA-2020-D5.1, http://cds.cern.ch/record/2213430 and references therein. 11

AIDA-2020: Central DAQ and run control Independent standalone (detector) DAQs. EUDAQ as central, high-level DAQ Lightweight modular and portable framework. Originally developed for (EUDET) pixel telescope and used in many beam tests. EUDAQ1 has a stable release and used for many years. Also in AHCAL beam tests. EUDAQ2 scalable and applicable to multidetector setups. A lot of recent progress; hope for a release soon. Users have to provide routines to interface their system. Laboratory tests AHCAL+BIF (Beam InterFace) and now do AHCAL+beam telescope in beam tests big step in common DAQ / EUDAQ integration. 12 K. Krüger

AIDA-2020: Monitoring Development of near-online checks of data quality: for individual detectors and coincidences between different detectors. Using DQM4HEP, developed for SDHCAL beam tests by R. Eté (IPNL, Lyon) and A. Pingault (UGent): https://github.com/dqm4hep Generic data structures compatible with any input data type. Interfaced with EUDAQ. System set up at DESY and used in AHCAL beam test. Participated in June SiECAL / SDHCAL beam test. Producer 0 Producer 1.... Producer n EUDAQ Data Collector Run Control Logger LCIO Stream Disk (LCIO) Monitor (EUDAQ) DQM4HEP LCIO File Streamer Event Collector Analysis Module T. Coates (Sussex) Monitor (DQM4HEP) 13

AIDA-2020: Monitoring Online time correlation of two detectors: AHCAL+BIF Real progress made on common system. 14

AIDA-2020: Event model To define an event model for online data, from different detectors with very different signals and properties. Based on LCIO framework. Also needed for data sanity and quality checks related to multiple-detector information. Lots of information gathering on current systems and their data (format). First proposal for EUDAQ raw data format. Information and proposals collected at: http://flcwiki.desy.de/aida2020wp5_task55_eventmodelforcombineddaq A. Irles 15

Summary and outlook A DAQ system for the ILC presents different challenges to the super-high-rate machines like the LHC. Some more generic R&D would be interesting: Overall system architecture Technology choices and survey of commercial solutions On- / near-detector processing Current focus is on providing common aspects to ease integration of multiple detectors in beam tests with progress in: Definition of interfaces and method of synchronisation Use of EUDAQ as the basic software Generic monitoring framework But, still much to do and many combinations of detectors to test. Expect significant progress over the next year or two Not able to provide a fully hardware- and software-integrated common DAQ system with detector specific parts and generic components. Ideally by the end of AIDA-2020, will have delivered on several aspects of the common system and can then move onto a more generic and fuller common DAQ system. 16