INDUSTRIAL HEAT EXCHANGERS

Similar documents
COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS / AIR COOLERS

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS

SECTION Heating Coils

IN THE MARINE INDUSTRY

SECTION AIR COILS

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Marine Heat Exchangers SALES SERVICE REPAIR

Heat Transfer Equipment

FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

SB Series Brazed Plate Heat Exchanger Installation Manual

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

Steam Coils. Types HI-F5, HI-F8 and E-F5. Catalog 413-6

THE COMPANY. TECHNICAL OFFICE AND PRODUCTION UNITS. Our company has two production units:

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

UltraHeat Plate and Frame Heat Exchangers. Engineered for Excellence

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

the new standard in Heat Transfer Equipment Century Series Heat Exchangers

UNIFIED FACILITIES GUIDE SPECIFICATIONS

EHH SERIES DRAW THROUGH FAN COILS CFM

APPLICATIONS FOR HVAC SYSTEMS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Rectangular Tube Recovery Series RTR

SECTION AIR COILS

REFRIGERATION PRODUCTS

SECTION AIR COOLED WATER CHILLERS

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

DIVISION 23 - HVAC HVAC Air Distribution

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Screw Compressors. AS Series. Capabilities from: 64 to 143 cfm Pressures from: 80 to 217 psig. kaeser.com

Packaged Steam Fired Water Heater

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

High Capacity Instantaneous Steam Fired Water Heater

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

SECTION AIR COILS

Yarway Repairable Drip and Tracer Steam Traps Series 751/761, 711/721, 731/741, 500/546, 460/515/D3

Screw Compressors. S Series. Capacities from: 8.8 to 89 cfm Pressures from: 80 to 217 psig.

Economical and simplified solutions that offer quality and optimum steam trap service.

Mechanical Engineering Department Sheet (1)

AIR HANDLER SPECIFICATION

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

Air treatment solutions. Aftercoolers & condensate treatment

Exchangers. Air-cooled Heat. Exchangers

Custom Duct Heaters. Special Applications

The right trap for the right application.

(2) 325 tpd York Chlorine Liquefier Systems

A product of tomorrow s technology.

ASME Packaged Indirect Fired Water Heater

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

Screw Compressors ESD SERIES. Capacities from: 816 to 1522 cfm Pressures from: 80 to 217 psig

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

TECHNICAL CATALOGUE Section 1 Technical Information

Immersion Heaters. Screw Plug Immersion Heater

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Compressed Air Filters

TYPICAL CPA SPECIFICATIONS

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

MAC-120HE-03 Air-Cooled Chiller

Thermal Fluid Heaters

Screw Compressors. DSD, ESD, and FSD Series ( hp) Capacities from: 544 to 2052 cfm Pressures from: 80 to 217 psig. kaeser.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Heating and Cooling Coils

FOR THE PETROLEUM AND RELATED INDUSTRIES

Product Catalog. Components and Systems for thermal applications. UHS United Heatexchanger Solution GmbH

SINCE Heat Exchangers. Plate and Frame FFW AHRI. Shell and Tube W & S. Brazed FFB cat-2016-he

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Cooler Range. For use with AESSEAL Seal Support Systems.

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

DIVISION 23 - HVAC HVAC Air Distribution

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

SECTION FAN COIL UNITS

Cooling, conditioning, purifying. Cooling, conditioning, purifying.

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Silhouette. Feedwater Heater. Boiler Feedwater

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Transcription:

INDUSTRIAL HEAT EXCHANGERS COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS

Overview Certifications CRN Applications / Products Air Dryers Compressed Natural Gas Economizers Engine & Turbine Exhaust Ethanol Production Fluidized Bed Dryers Heat Recovery High Pressure Aftercoolers Motor & Generator Coolers Natural Gas Coolers Overhead Stripper Condensers Pollution Control Primary Air Coolers Process Cooling / Refrigeration Process Heaters Rotary Kilns Steam Coil Air Preheaters Superheaters Turbine Inlet Air Coils Featured Working Fluids Steam Water Glycols / Compressed Gas Thermal Oil Refrigerants Glycol Mixtures

Industrial Heat Exchangers Primary Air Cooler The Customer Needed: SRC Engineered: Variable operating conditions to meet customer demand 1 Modular air coolers that enabled operation from 10-110% of rated capacity To minimize the impact of airborne contamination on An in-line fin pattern to minimize the risk of fouling and contamination product performance 1 To reduce uncertainty of performance 3 Thermally modeled performance that included over 60 points of operation To maximize quality and reliability 4 ASME U-Stamp Section VIII, Div. 1 / CRN Code requirements Superheater / High Temperature Heat Recovery The Customer Needed: SRC Engineered: Corrosion free heat transfer for Chemical Refining process 1 A finned tube bundle that uses 304H stainless steel Insulated core product to prevent energy loss and provide a safe operating environment Produce superheated steam from entering steam tem- 3 Heat exchanger with cast insulation that was designed for 1400 F gas temperatures A heat exchanger with 3" schedule 40 welded fin pipe delivery a leaving 3 perature of 300 F Compliance to high quality and performance standards 4 steam temperature of 800 F Unit designed to ASME Section VIII, Div. 1 Code and stringent 1 Non-Destructive Testing. 3

Industrial Heat Exchangers 4" 1 6" 3' 10' 8' Combustion Air Preheater Tube: 0.875" x 0.109" wall carbon steel Fin: 0.03" aluminum plate Certification: ASME U-Stamp Section VIII, Div. 1 Ports for daily washing Coils slide out for major cleaning Hot Water for a Dryer Exhaust System Tube: 0.875" x 0.49" carbon steel Certification: ASME U-Stamp Section VIII, Div. 1 Design: 3 row heat exchanger for 63,655 lb/hr of entering gas Fluid Temperature: 435 F Working Fluid: Mobiltherm 603 8' 1/4" 9' 8" 8' 7' 5' 3' Turbine Inlet Air Cooling Coil Tube: 5/8" x 0.05" wall copper Header: 4" schedule 40 304 stainless steel Certifications: CRN Design: For -58 F entering air temperatures E-coated Primary Air Cooler Tube: 1.0" x 0.083" carbon steel ASTM SA179 seamless Fin: 0.0" aluminum embedded spiral wrapped Flange: Class 600 carbon steel flanged raised face slip-on flanges Certification: ASME U-Stamp Section VIII, Div. 1 and CRN Weight: 1,500 lbs 4

8" 5' 3' 5' 3' Multi-Row Heat Recovery Unit Pipe: 5 rows of.0" x 0.134" chrome molybdenum Pipe: 11 rows of.0" x 0.134" carbon steel Fins: Carbon steel welded spiral wrap, 0.06" thick and 0.65" high Header: 6" schedule 10 headers with 6" 600# RFWN flanges Weight: 7,633 lbs Process Water Tube: 1.0" x 0.049" wall 316L stainless steel Header: Schedule 40 316L stainless steel Hot dip galvanized coating " Overhead Stripper Condenser Tube: 1 x.083 carbon steel Fin: 0.015" thick aluminum L-foot spiral wrapped Header: SA-516 GR70 normalized plug box Process Cooler Tube: 0.65" x 0.083" 304 stainless steel SA-13 Fin: 0.0075" copper at 9 fpi Header: 3" nominal schedule 40 304 stainless steel Weight: 1,000 lbs Operating Pressure: 4,00 psig 5

Core Materials Tube & Pipe Sizes Materials Plate Fin OD: Up to 1" Spiral Wrapped Finned Tube OD: Up to " Specialty Fin Tube O.D.: Up to 1.75" Hastelloy Wall Thicknesses: Up to.134" AL6XN Fin Types Spiral Wrap: From -1 fins per inch Cupro-Nickel (CuNi) Monel Chrome Molybdenum Titanium Turbulators Ball Matrix Spring Twisted Tape Coatings Blygold E-Coat Heresite / Baked Phenolic Hot Dip Galvanize Nickel Plating Copper Copper Elliptical / L-Foot Fin Embedded Fin Extruded Fin Heavier duty than edge wound. Can withstand Recommended for high temperature or cyclic Manufactured by extruding an aluminum heat cycling and vibration services sleeve with a parent tube. Recommended for moderate to heavy duty applications Any Tube / Copper Fin Chrome-moly Welded Base fin is continuously welded to the tube. Recommended for heavy duty applications Solder Coated Recommended for replacement applications Plate Fin: Up to 0.03" thick Aluminized Steel Flat Fin Recommended for environments with contamination in the airstream or heavy duty cleaning requirements Aluminized Steel Corrugated Fin Provides good heat transfer capabilities with moderate air friction Aluminized Steel Sine Fin Provides superior heat transfer capabilities 6

Header Types & Inspection Header Types Pipe Headers Suitable for most pressures and applications, pipe headers are the most common type of manifold. Water Box with Removable Cover This header type has a removable cover to enable inspection, cleaning and plugging of inner tube walls. This design can typically handle pressures up to 00 psi and is suitable for users concerned about corrosion or fouling in their operation. Half Pipe D Style Headers A less expensive configuration compared to the plug box and removable cover water box, which allows for multiple serpentine circuiting for selected applications. Users may consider this type of header if operating with clean fluids which do not require regular service intervals. Design pressures up to 300 psi are easily accommodated. Plug Box Header This is a general purpose header that allows for individual tube cleaning. Users should consider this type of header if they are concerned with fouling of the tubes and want minimal downtime. Available Testing & Verification Services NDE: Non-Destructive Examination Available Liquid (Dye) Penetrant Magnetic Particle Ultrasonic Testing Radiography Visual Examination PMI: Positive Material Identification 7

COILS / INDUSTRIAL HEAT EXCHANGERS / NUCLEAR PRODUCTS 104 Peavey Road Chaska, MN 55318 (800) 394-645 610 South 1 st Street Phoenix, AZ 85034 (800) 899-645 451 Southlake Blvd. Richmond, VA 336 (800) 9-645 www.superradiatorcoils.com