WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

Similar documents
LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

WZH Ground source heat pumps

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

LZT High efficiency air to water heat pumps with E.V.I. compressors

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

GROUND SOURCE HEAT PUMPS WDH SERIES TECHNICAL MANUAL

nemo a hp rcgroupairconditioning R410A

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

LVN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

GHE Dehumidifiers for radiant cooling systems with heat recovery

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Water chillers water/water type SIGMA Technical information manual

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

G E N E R A L C ATA L O G Dehumidif ers

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

STANDARD DEHUMIDIFIERS EH SERIES TECHNICAL MANUAL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

CRIMSON & CRIMSON MAX

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

FH - GH Dehumidifiers for radiant cooling systems

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

PRODUCT GUIDE

Kälte Klima. Water cooled water chillers from 200 kw to 1550 kw. Screw Compressor LCWX DE 56 01/16 12/13

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Motor-driven condensing units MTE MTE R-410A

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Air Cooled Chillers & Heat Pumps WinPACK HE-A

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

kw COOLING kw HEATING

pyxis u pyxis ua NEW rcgroupairconditioning

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Blue Box Epsilon Echos +

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Modular Air-cooled Chillers

Water cooled chillers and heat pumps

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Aquaflair. Residential and Industrial Cooling Systems

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

PYXIS U PYXIS U. rcgroupairconditioning

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Galletti Water chillers and heat pumps catalogue

ZETA kw. Installation, operating, and maintenance manual. Manual B02 Issue Replaces 04.02

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

unico pf unico pf rcgroupairconditioning

Superchiller Product Documentation. English. cod rev Issued by TDS

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

Transcription:

Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures at 7 C, commonly used in combinations with fan coils or/ and air handling units. The water chillers provide high efficiencies and quiet operation in any application. The different versions allow the user to select the most suitable solution thanks to a wide range of accessories. VERSIONS, cooling only version, available in 11 different sizes. /HP, reversible heat pump version, available in 11 different sizes. /EV, motoevaporating unit, available in 11 different sizes. ACCESSORIES Hydraulic kit A1ZZ with: pump, expansion valve, safety valve, flow switch, insulated tank. Antifreeze kit (only for A versions). Hydraulic kit A1NT with: pump, expansion valve, safety valve, flow switch. LS low noise version. Partial heat recovery. Rubber or spring vibration dampers. Electronic soft starter. Manometers. Pressostatic valve. Remote control panel. Serial interface card RS485. 66

Versions /HP 04 05 07 09 13 15 20 25 30 35 40 Cooling capacity (1) kw 4,1 4,8 8,1 9,4 14,6 17,7 19,5 24,5 30,1 35,7 39,7 Compressors input power (1) kw 1,1 1,2 1,9 2,4 4,2 4,1 4,8 5,9 7,2 8,5 9,7 Evaporator water flow (1) m 3 /h 0,7 0,8 1,4 1,6 2,6 3,1 3,3 4,2 5,2 6,0 6,7 Condenser water flow (1) m 3 /h 0,3 0,4 0,6 0,7 1,2 1,3 1,5 1,9 2,3 2,7 3,0 Heating capacity (2) kw 4,9 5,7 9,6 11,0 17,6 20,7 22,7 28,5 35,0 41,4 46,5 Compressors input power (2) kw 1,1 1,2 1,9 2,4 4,2 4,1 4,7 5,9 7,2 8,4 9,7 Evaporator water flow (2) m 3 /h 0,9 1,0 1,7 2,0 3,1 3,7 4,0 5,0 6,2 7,3 7,9 Condenser water flow (2) m 3 /h 0,6 0,7 1,2 1,3 2,0 2,5 2,7 3,5 4,3 5,2 5,8 Power supply 230V - 1-50 Hz 400/3+N/50 Nominal input current A 6,8 9,4 12,3 15,5 9,7 11,3 15,4 18,0 19,7 23,7 28,7 Peak current A 34,0 42,0 68,0 75,0 68,0 77,0 102,0 126,0 129,0 169,0 201,0 Max input current A 7,4 10,0 13,3 16,5 12,0 14,1 18,2 20,8 21,4 25,4 31,3 Compressors / Circuits n Rotary 1/1 Scroll 1/1 Evaporator / number Plates / 1 Condenser / number Plates / 1 Sound power level (3) db(a) 50 51 52 52 54 54 60 60 62 64 64 Sound pressure level (4) db(a) 42 43 44 44 46 46 52 52 54 56 56 Water pump kw 0,13 0,13 0,2 0,2 0,3 0,45 0,45 0,45 0,55 0,55 0,9 Pump available static pressure kpa 59 55 42 38 72 53 117 55 122 116 90 Water tank l 40 40 40 40 40 40 40 40 40 40 40 (1) Cooling: data are refered to units complete with pressostatic valve, evaporator water temperature in/out 12/7 C, condenser water temperature in/out 15/30 C. (2) Heating: condenser water temperature in/out 40/45 C; evaporator water temperature in/out 10/5 C. Without pressostatic valve. (3) Sound power level according to ISO 3746. (4) Sound pressure level at 1 mt from the unit in free field conditions direction factor Q = 2 according to ISO 3746. Versions /EV 04 05 07 09 13 15 20 25 30 35 40 Cooling capacity (5) kw 4,1 5,2 7,5 8,7 13,7 15,9 18,2 25,0 29,3 35,2 43,9 Compressors input power (5) kw 1,2 1,5 2,3 2,5 4,0 4,7 6,0 7,2 8,2 10,2 12,3 Water flow (5) m 3 /h 0,7 0,9 1,3 1,5 2,4 2,8 3,2 4,3 4,9 6,1 7,4 Nominal input current A 6,8 9,4 12,3 15,5 9,7 11,3 15,4 18,0 19,7 23,7 28,7 Peak current A 34,0 42,0 68,0 75,0 68,0 77,0 102,0 126,0 129,0 169,0 201,0 Max input current A 7,4 10,0 13,3 16,5 12,0 14,1 18,2 20,8 21,4 25,4 31,3 Power supply 230V - 1-50 Hz 400/3+N/50 Compressors / Circuits n Rotary 1/1 Scroll 1/1 Evaporator / number Piastre / 1 Condenser / number Not present Sound power level (3) db(a) 50 51 52 52 54 54 60 60 62 64 64 Sound pressure level (4) db(a) 42 43 44 44 46 46 52 52 54 56 56 Water pump kw 0,13 0,13 0,2 0,2 0,3 0,45 0,45 0,45 0,55 0,55 0,9 Pump available static pressure kpa 59 55 42 38 72 53 117 55 122 116 90 Water tank l 40 40 40 40 40 40 40 40 40 40 40 (5) EV version: condensing temperature 50 C, evaporator water temperature in/out 12/7 C. (3) Sound power level according to ISO 3746 (LS versions). (4) Sound pressure level at 1mt from the unit in free field conditions direction factor Q = 2 according to ISO 3746 (LS versions). 67 www.hidros.it

FRAME All units are made from hot-galvanised thick sheet metal, painted with polyurethane powder enamel at 180 C to ensure the best resistance against the atmospheric agents. The frame is self-supporting with removable panels. All screws and rivets for outdoor installations are in stainless steel. The colour of the units is RAL 9018. REFRIGERANT CIRCUIT The refrigerant gas used in these units is R407C. The refrigerant circuit is made by using international primary brands components and according to concerning welding procedures. The refrigerant circuit includes: sight glass, filter drier, thermal expansion valve with external equalizer, reverse cycle valve (for heat pump version only), one way valve (for heat pump version only), liquid receiver (for heat pump version only), Schrader valves form maintenance and control, pressure safety device (according to PED regulation). COMPRESSORS The compressors are scroll type (rotative type for sizes 04,05,07 only), with crankcase heater and thermal overload protection by a klixon embedded in the motor winding. The crankcase heater, when present, is always powered when the compressor is in stand-by. The inspection is possible through the frontal panel of the unit that allows the maintenance of the compressors even if the unit is working. CONDENSERS AND EVAPORATORS The evaporators and the condensers are made of AISI 316 stainless steel brazewelded plates type. The use of this kind of evaporators allows a massive reduction of the refrigerant charge of the unit compared to the traditional shell-in-tube evaporators and also. The evaporators are factory insulated with flexible close cell material and can be equipped with antifreeze heater (optional). In the heat pumps versions the condensers are factory insulated with flexible close cell material and can be equipped with antifreeze heater.each evaporator is provided with a temperature sensor as antifreeze protection. MICROPROCESSOR All units are supplied standard with microprocessor controls. The microprocessor controls the following functions: regulation of the water temperature, antifreeze protection, compressor timing, compressor automatic starting sequence, alarm reset, potential free contact for remote general alarm, alarms and operation leds. Upon request any microprocessor can be connected to a BMS system for the remote control and management. The technical department is available to study, together with the customer, different solutions using MO- DBUS; LONWORKS; BACNET or TREND protocols. ELECTRIC BOX The electric box is made according to electromagnetic compatibility norms CEE 73/23 and 89/336. The accessibility to the board is possible after removing the front panel of the unit. In all units are installed, standard, the compressors sequence relay which disables the operation of the compressor in case the power supply phase sequence is not the correct one (scroll compressors in fact, can be damaged if they rotate reverse wise). The following components are also standard installed: main switch, magnetic-thermal switches (as a protection of pumps), compressors fuses, control circuit automatic breakers, compressor contactors, pump contactors. The terminal board is supplied with voltage free contacts for remote ON-OFF, Summer / winter change over (heat pumps only) and general alarm. CONTROL AND PROTECTION DEVICES All units are supplied with the following control and protection devices: Return water temperature sensor, installed on the return water line from the plant (12 C), antifreeze protection sensor installed on the outlet water temperature (7 C), high pressure switch with manual reset, low pressure switch with automatic reset, high pressure safety valve, compressor thermal overload protection, fans thermal overload protection, plate mechanical flow switch. MOTOEVAPORATING VERSIONS EV This version includes a microprocessor control to manage the compressor and alarms timings. The refrigerant gas is R407C. This unit has only a nitrogen charge. HEAT PUMP VERSIONS HP The heat pump versions are provided with a 4 way reverse cycle valve and are suitable to produce hot water up to a temperature of 50 C. They are always supplied with liquid receiver and a second thermostatic valve to optimize the efficiency of the refrigerant cycle in heating and in cooling. The microprocessor is set for automatic defrost (in case of operation in severe ambient conditions) and for summer/winter change over. 68

MOTOEVAPORATING UNITS REFRIGERANT CONNECTIONS Motoevaporating unit /EV must be connected to the indoor unit by refrigerant lines. The condensing units are supplied without refrigerant charge and filled with nytrogen. Piping layout and max distance betneen the sections. On split-system applications, piping layout is determined by sections location and building structure. Piping should be as shorter as possible in order to reduce pressure drops in refrigerant circuit and the refrigerant charge in the system. Maximum admitted pipe length is 30 meters. Our technicians are available to study other kinds of applications which don t respect the limits reported above. /EV remote condenser installed at a higher level than the compressors Install a collection pit on discharge and return line so that liquid refrigerant, when the system is not running, can be collected by this pit, avoiding its return to compressor heads, and possible failure; On horizontal pipelines a minimum 1% slope should be allowed in order to drain oil in the proper flow direction. /EV remote condenser installed at a lower level than the compressors On the rising vertical pipes, oil traps should be fitted every 6 metres to allow oil circulation in the system; On horizontal pipelines a minimum 1% slope should be allowed in or- der to drain oil in the proper flow direction. The refrigerant line diameters can be obtained by the refrigerant circuit, depending on the selected size and the distance between the indoor and the outdoor unit. 1 ~ 6m ~ 6m 1 /EV higher than the remote condenser /EV lower than the remote condenser 69 www.hidros.it

Refrigerant line diameters for EV versions Distance (m) 10 20 30 Mod. Gas (mm) Liquid (mm) Gas (mm) Liquid (mm) Gas (mm) Liquid (mm) 04 10 8 10 10 --- --- 05 10 8 12 10 --- --- 07 12 10 16 10 --- --- 09 12 10 16 12 16 12 13 16 12 16 12 16 16 15 16 12 16 16 18 16 20 16 12 18 16 18 16 25 18 16 18 16 22 16 30 18 16 22 16 22 18 35 22 16 22 16 22 18 40 22 16 22 18 22 18 Refrigerant charge for liquid line Liquid line diameter Refrigerant charge g/m Liquid line diameter Refrigerant charge g/m 8 (mm) 30 12 (mm) 85 10 (mm) 55 16 (mm) 165 18 (mm) 215 --- --- Cooling capacity correction factors Mod. Refr. Line 0 mt. Refr. Line = 10 mt. Refr. Line 20 mt. Refr. Line 30 mt. /EV 1 0,98 0,96 0,95 70

Model /EV /HP Code 04 05 07 09 13 15 20 25 30 35 40 Main switch - - - - - Flow switch - Microprocessor control - LS low noise basic version LS01 LS low noise A1 version LS01 Partial heat recovery RP00 - - - - Spring vibration dampers KAVM Rubber vibration dampers KAVG Manometers MAML Kit valvola pressostatica per versione solo freddo VPSF Kit valvola pressostatica per versione a pompa di calore VPRV Electronic soft starter DSSE Remote control panel PCRL Serial interface card RS485 INSE Hydraulic kit A1ZZ with tank and one pump A1ZZ Hydraulic kit A1NT with one pump without tank A1NT Standard, Optional, Not available. - /EV A (mm) B (mm) C (mm) Kg 04/05 770 550 570 75/80 07/09 770 550 570 87/95 13/15 940 700 570 110/118 20/25 940 700 570 130/138 30/35 940 700 570 144/152 40 940 700 570 164 /A1 - /A1/EV /A1 A (mm) B (mm) C (mm) Kg 04/05 1280 1003 633 93/98 07/09 1280 1003 633 105/113 13/15 1280 1003 633 128/136 20/25 1280 1003 633 145/159 30/35 1280 1003 633 170/185 40 1280 1003 633 195 71 www.hidros.it