Product Specifications Warning Light Control Cabinet

Similar documents
Product Specifications Warning Light Control Cabinet

Product Specifications Linear Accelerator Relay Junction Box

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Fail Safe Emergency Power Off Control Panel 480V 3 Phase

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications Auto Restart Main Power Distribution Panel

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MaxLite LED High Bay Fixtures

MaxLite Polygon Linear LED Light

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Instruction Manual and Warranty

Quest Power Electric Heat EHS 31 Pro

Owner s Manual Phoenix FireBird

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

D E S I G N G U I D E REVISED 10 / 2017

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

D E S I G N G U I D E REVISED 9 / 2018

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Installation Instructions

Electric Duct Heaters

Universal Fan and Light Remote Control

Installation & Maintenance Instructions

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Panel Mounted Heat Exchangers by Dantherm, Inc.

Owner s Manual Hydro-X Vacuum Pac

Quest Power Electric Heat EHS 62 Pro

Installation, Operation & Service Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

IMPORTANT SAFETY INFORMATION

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Guide Specification Model CTG Automatic Transfer Switch

INSTRUCTIONS FOR OPERATION AND CARE OF

* These Remote Mics must be SPRM-GP

INSTALLATION INSTRUCTIONS

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Booster Power Supply Manual

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

MaxLite LED Vapor Tight Linear Fixture

BACKUP BATTERY INSTALLATION INSTRUCTIONS

ASCO Series 185 Power Transfer Switches

NXM2G Installation and Operating Manual

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

INSTALLATION and OPERATION INSTRUCTIONS

Inline Heater for Solvent or Gas. Installation and Operation Manual

ELP21LU3-LF-HLOL THREE CHANNEL

MaxLite LED Round Pendant Highbay Series

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Service Parts, Kits and Accessories

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

PANTHER. Condensate removal pump Installation and operating guide

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Brasch Hazardous Location Unit Heaters

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

OPERATION AND INSTALLATION MANUAL

GETZ MANUFACTURING PART # CYLINDER DRYER

Remote Relay Module (RRM)

SECTION (15767) - UNIT HEATERS

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

INSTRUCTIONS! DO NOT DISCARD!

PLL. Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

For use with models: BP , BP , BP

DEMA 830 Laundry Master TM Installation Instructions

GAS MONITOR Model Model

OPERATION, SERVICE & PARTS MANUAL

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Transcription:

NOVA Energy & Automation Product Specifications Warning Light Control Cabinet Model NEAS-RB024D-EWA 03 January 2012

Product Description 1. Standard Applications The Nova NEAS-RB024D-EWA is an integrated lighting controller designed to meet the hospitalgrade lighting power requirements of medical imaging suites. The low voltage control panel provides a safe, low voltage interface between the imaging equipment, warning lights, operator s control, and room line voltage. Figure 1: Nova Warning Light Controller Application Diagram 2. System Compatibility The Nova NEAS-RB024D-EWA is compatible with the following medical imaging equipment: Siemens Medical X-ray: Axiom Multix MT and several other similar installations. Quantum Medical X-ray: Q-Rad System and several other similar installations. 3. Identification Siemens Medical- The proper panel can be identified on Siemens Medical Construction Drawings: sheet E-101 Note 2: Auxiliary Wiring X-ray warning lights and door switch schematic. Equal to relay box with related components Quantum Medical- The proper panel can be identified on Quantum Medical Construction Drawings: sheet E-101 Auxiliary Wiring Relay JB. Equal to relay box with related components Co Author: JF 2

4. Features/ Benefits Features Benefits Integrated design provides all of the lighting controls into an easy to configure panel. Utilizes heavy duty contacts to handle light currents. Controls up to 2 separate warning lights via integral double pole, single throw contactor. UL and cul listed to conform to NEC. Isolates lighting system voltages from imaging system. Labeled to conform with NFPA99, NFPA-70, and the OEMs specifications. Provides a fixed junction point for the warning sign controls. Compact size for easy installation Fused Short circuit protection. No minimum load required Factory wired and tested. Simple field configuration can accommodate several different equipment installations. Integrated Hospital Supplied Class 2, 24VAC power source. Designed, tested, and installed on several projects worldwide. Meets the requirements as specified by Siemens. Reduced weight- all components are within a small 10 lb enclosure. Eliminates multiple lighting control systems. Reduces installation time and cost by eliminating delays in obtaining individually enclosed components and by eliminating on site assembly. Provides a standardized platform for other future modifications or upgrades. Figure 2: Nova Warning Light Controller Co Author: JF 3

5. Specifications Model Application Input Voltage Input Frequency Input Current SCC Rating Control Voltage Maximum Sign Load Warning Light Controls Approvals NEAS-RB024D-EWA Warning Light controls for medical imaging equipment 110VAC (please specify if other voltage requirements are needed) 60Hz (please specify if other frequencies are required) AC input (maximum): 5 A Short Circuit Interrupting Rating 5 KA Externally derived 24VDC from control or imaging equipment source. 15 Amps Compatible with up to 2 warning lights, LED or incandescent UL/cUL 6. Weight and Dimensions Mounting Dimensions Weight Mounting Enclosure Warning Light Controller is provided in a steel enclosure suitable for surface, wall or above the ceiling mounting. Height: 7.9 (200mm) Width: 7.9 (200mm) Depth: 4.7 (120mm) 10 lbs. (4.54 kg) Rear wall mounting holes (4). Spaced 0.79 (20mm) from enclosure edge. Optional mounting brackets are available Model KL 1502510; 18 Gauge Carbon Steel, all rounded corners. Finish Dip coat primed, powder coated in textured RAL 7035 Cover Protection Category Captive screw-type cover IP 66, UL Type 1, 4, 12, Co Author: JF 4

Figure 3: Enclosure Dimensions inches (mm): Outside, Depth 7. Warranty This limited warranty set forth below is given by Nova Automation ( Seller ) with respect to the electrical equipment ( Product ) packaged with this limited warranty. The Product, when delivered to you in new condition in its original packaging, is warranted against defects in materials or workmanship as follows: For a period of one (1) year from the date of original purchase, defective parts or a defective Product returned to a Seller, or its authorized service providers, as applicable, and proven to be defective upon inspection, will be repaired, or exchanged for a new Product, as determined by the Seller, or the authorized service provider. This limited warranty covers all defects encountered in normal use of the Product, and does not apply in the following cases: Loss of or damage to the Product due to abuse, mishandling, alteration, accident, electrical current fluctuations, failure to follow operating, maintenance or environmental instructions prescribed by Seller, failure to follow Sellers installation instructions, or service performed by someone other than Seller or its authorized service provider. Nova assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any consequential or incidental damages arising from the use of the product. Nova Automations entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement of the product. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE FOR WHICH IT WAS MANUFACTURED. Co Author: JF 5

8. Product Service and Technical Assistance Nova Automation, LLC 2722 N. Avondale Blvd Milwaukee WI 53210 PH# 262-309-2950 Website: www.novaautomation.net Co Author: JF 6