August 15-17, By K. Holtrop for the DIII-D Team

Similar documents
Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

STER 1981 ANNUAL INDUSTRIAL SUMMARY OF FIRE AND PROPERTY DAMAGE EXPERIENCE. Monsanto. MOUND FACILITY Miemisburg. Ohio MLM.ML

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

/,6 REMOTE MONITORING DESIGN CONCEPTS FOR SPENT FUEL STORAGE FACILITIES

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Electronic Refrigerant Leak Detector DE-FG36-98G Micronic, Inc. Elie Talamas, Jr. Period: 10/1/99 to 12/31/99

Facility Hazard Surveillance of JLab Facilities

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

Why Thermostats Matter

North Dakota State University Laser Safety

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

HALL D WORKER SAFETY AWARENESS TRAINING (SAF113)

EU Diagnostics: Recent progress & near-term opportunities. Frederic Le Guern on behalf of Glenn F. Counsell Programme Manager. 18 th September 2018

Laser Use Registration & Application (L.U.R.)

Cryogenics for Neutral Beam Injector System

Laser Use Authorization

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

Food Service Technology Center

Experiences and Challenges in Pumping the 200m3 vacuum chamber at JET

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

Radiation Control and Monitoring System on the HTTR

Radiation Safety issues for the PF-AR in KEK

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

THE TORE SUPRA CRYOGENIC SYSTEM. Design and operation

Document Preparation Profile (DPP)

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Cryogenics. Overview of the Jefferson Lab 12GeV Upgrade. J. Creel, K. Dixon, P. Knudsen, J. Wilson Jr.

Condensate Induced Water Hammer in a Steam Distribution System Results in Fatality

Laser Safety Part III Administration

G4 Pulsed Fiber Laser

Particle Accelerators - Their Hazards and the Perception of Safety

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

Applications and Accessories, Cryo Pumps

SEC Signature Process Gas Analyzer

SI SAFETY, ENVIRONMENTAL AND HEALTH TRAINING REQUIREMENTS 9/14/2009

PART V: WORKING WITH LASERS

Auto Technology Company Cyclic Corrosion Test Chamber

Safety Manual Section 15 Radiation Safety

Fiber Tower Desktop SAFETY & OPERATION MANUAL

HI-3510 RF Radiation Badge Broadband Electromagnetic Radiation Detector User s Manual

Detection of Inherent and Laser-Induced Scatter in Optical Materials

COMPATIBILITY OF REFRIGERANTS AND LUBRICANTS WITH MOTOR MATERIALS UNDER RETROFIT CONDITIONS. Final Report

Safety Standards for Electronic Products

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

CHAPTER 3 RADIATION PRODUCING DEVICES I. AUTHORIZATION TO USE RADIATION PRODUCING DEVICES

NECA S System Approach to Electrical Safety for NFPA 70E

The RSO will submit a copy of the revised manual to the RSC for approval when the revised manual has substantial changes.

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

(h) Pesticide Application.

NFPA Electronic Safety Equipment Standards What s happening now!

Vacuum Insulated Pipe

Metal hydride storage system for MICE experiment at Rutherford Appleton Laboratory. Technical specification.

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

REED COLLEGE DEPARTMENT OF COMMUNITY SAFETY DEPARTMENTAL DIRECTIVE CSO FIRE & FIRE ALARM SYSTEM RESPONSE GUIDELINES

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

Laser Safety. This Laser Safety Program applies to the acquisition, use, transfer, and disposal of all Class 3B and 4 lasers at UNC Asheville.

NECA S System Approach to Electrical Safety for NFPA 70E

PURPOSE OF THE PROCEDURE

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

HALL D WORKER SAFETY AWARENESS TRAINING (SAF113)

Rutgers Environmental Health and Safety (REHS)

Electrical Safety Requirements

Review of Recent Laser Incidents at DOE facilities. Joanna Casson Los Alamos National Laboratory

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Air Compressor Electrical Fire

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

An Overview of Extinguishing Systems for Computer Equipment

PlateScrape Plate Pre-Scrapper Test Report

High-Altitude, Aerial Natural Gas Leak Detection System

Southern California Gas Company Customer Programs Department

Ceiling Mount Air Purification System

COMBUSTIBLE DUST SAFETY PROGRAM

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

Laser Safety Part III Administration

X-Ray Protection Program

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

Variable Temperature Options for Optical Experiments

SIDEWINDER DRILLING RIG 107 HOUSTON, TEXAS

All personnel working in experimental areas at Jefferson Lab must have completed the EH&S Orientation at Jefferson Lab.

Radiation and Laser Safety

2018 DOE Laser Worker Survey Results. Matthew Quinn 12 th DOE LSO Workshop 9 May 2018

FAIRA TRANSPARENCY REPORTS. February 28 th, 2018

COLD WEATHER START KIT Ceiling Mount 4000

4.13 Security and System Safety

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Directive on Laser Safety. NRC Occupational Safety and Health Manual

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

MERIT Experiment Status of Activities at CERN

Radiation Emitting Devices Research X-ray Safety Program

Using ALARA Technologies to Solve Everyday HP Challenges

Transcription:

DIII-D Safety Program Incidents and Lessons Learned By K. Holtrop for the DIII-D Team Presented at the DOE Accelerator Safety Workshop Thomas Jefferson National Accelerator Facility Newport News, VI August 15-17, 2017 Work supported in part by U.S. DOE under DE-FC02-04ER54698. 1708-0109 / 1

Outline Overview of the DIII-D Facility DIII-D Safety Program Review of Recent Incident: LN 2 cryogenic leak Ongoing improvements to DIII-D Safety Program 1708-0109 / 2

DIII-D Tokamak System Capabilities DIII-D Tokamak Vacuum Vessel 35 m 3 Inconel 625 vessel Coils Toroidal field 2.2 T on axis 18 Poloidal field shaping coils 6 external coils, 12 internal coils Plasma Control 18 CPUs, 40 GB real-time CPU network Heating and Current Drive (injected power/pulse) Neutral Beams: 8 sources; 20 MW (80 kev Deuterium) Electron Cyclotron (Microwaves): 6 gyrotrons@110 GHz; 3.5 MW (5 s) Divertor/First Wall/Conditioning 3 LHe cryopumps; 15 20,000 l/s ATJ graphite 350 o C bake, boronization, Helium glow discharge between pulses 1708-0109 / 3

Multiple Hazards Exist at DIII-D Ionizing radiation (neutrons, gamma rays, X-rays), tritium Electrical (120V - 138 kv AC, >100 kvdc); high current (>100 ka) Microwave (110 GHz >1MW), RF (100 MHz >2 MW) Magnetic fields (<5T) Lasers (Visible and IR, Class I IV, pulsed and SS) Cryogenic (LHe/LN2 asphyxiation, cold, embrittlement, pressure) Explosive & toxic gases (D 2, diborane, Ar, Ne, Xe, N 2, CD 4, CF 4, and CCl 2 F 2 ) High pressure (water < 300 psi, hydrauilc < 5000 psi, compressed gases <2200 psi) High noise levels High temperature surfaces (350 o C) Confined spaces 1708-0109 / 4

Strong Involvement of Collaborators is Essential to the Excellence of the DIII-D Diagnostic Set Coherence imaging (LLNL/ANU) FIDA (UCI) NPAs (UCI) IR cameras (LLNL) SXR (UCSD) Fast ion collectors (UCI) BES (U Wisc) FIR & µw scattering (UCLA) Vertical scanning probe (UCSD) MDS spectrometer (ORNL) Gamma detectors (UCSD) Filterscopes (ORNL) Visible cameras (LLNL) ECEI & MIR (UCD) Neutrons (UCI) Phase contrast imaging (MIT) Radial 1708-0109 scanning / 5 probe (UCSD) UF-CHERS (UW) DISRAD (UCSD) VUV cameras (LLNL) ASDEX gauges (ORNL) MSE (LLNL) Fast framing camera (UCSD) ECE 4/2013 (UT,U Md) CP swing probes (U Tor./GA) DBS & CECE (UCLA) Langmuir probes (SNL) Reflectometers (UCLA)

Aerial View of DIII-D Facility, Located in San Diego, CA Low & High Pressure Deionized Water Pumping Systems 138kVAC/480VAC Substation 5MW West Substation (Fed from Dunhill) Helium Gas Storage Two RF Transmitter PSs 30kVDC, 125A Five Gyrotron PSs 105kVDC, 90A Diagnostics Lab Eight Neutral Beam PSs 120kVDC, 100A Control Room 12.47kVAC Switchgear (from 138kVAC Line) Dunhill Substation 138KVAC & 69kVAC Substations DIII-D Machine Three Cooling Towers 1708-0109 / 6 525MVA Motor Generator DIII-D INTRODUCTION

Recent Upgrades to DIII-D Operations Tungsten inserts installed in high heat flux areas Investigate materials that minimize tritium uptake Novel Design of Divertor Structure to spread heat flux over a large area Use of 3D printer for mock-up of tiles and creation of mounting templates. Completed development of high power 1.5 MW gyrotron (117.5 GHZ) for plasma current drive Developed high power Helicon antenna (476 MHz) Coating walls with lithium and Silicon Carbide Health and Hazard issues that need to be addressed Safety Program that evolves with our new upgrades 1708-0109 / 7

Outline Overview of the DIII-D Facility DIII-D Safety Program Review of Recent Incident: LN 2 cryogenic leak Proactive Safety initiatives 1708-0109 / 8

DIII-D Safety Program Supported by General Atomics Corporate Safety Organizations DIII-D Operates Under a DOE Cooperative Agreement Externally regulated by Cal-OSHA and other state and local regulations Radiological exposure governed by State of California Radiation Control Regulations (Title 17). DIII-D procedures and ALARA program set targets below legal limits. DIII-D program supported by General Atomics Corporate Environmental Safety & Health Group and Health Physics Group DIII-D Safety Committee and Energy Group Safety Officer (employee of GA ES&H Group) DIII-D Emergency Response Team 1708-0109 / 9

Overview of DIII-D Safety Program The Safety Program at DIII-D is based on Integrated Safety Management (ISM). It has been a successful system for assuring safe and efficient operations Hazards identified for each task and engineered controls are put in place to protect personnel & equipment Safety training for all personnel is regularly evaluated, provided on an on-going basis, and tracked Processes and procedures are in place to control work Lessons learned from incidents/near-misses are used to strengthen the Safety program DIII-D has created an environment with relative freedom from danger, risk, or threat of harm, injury, or loss to personnel and property 1708-0109 / 10

DIII-D Safety Program OSHA Recordable injuries have decreased from 2012 Injuries have decreased in past 5 years Categorizing incidents Improved investigations Targeted safety initiatives Improved safety awareness Encourage Near Miss reporting The chart displays the OSHA rate per 100 Energy employees. One injury is occurring per 400 Energy employees 1708-0109 / 11

DIII-D Safety Program Most Injuries Due to Normal Low Tech Work Activity Engineering controls are in place for high hazard areas such as high voltage and laser rooms to ensure that injuries do not occur Most injuries have occurred due to muscle strain and cuts from normal work activity Electrical shocks occurred from low power supplies Injury Types from 2011-2016 1708-0109 / 12

Outline Overview of the DIII-D Facility DIII-D Safety Program Review of Recent Incident: LN 2 cryogenic leak Ongoing Improvements to DIII-D Safety Program 1708-0109 / 13

LN 2 cryogenic leak: Summary On Tuesday 2/21/17 at 2:00 am a line carrying liquid nitrogen from a 11,000 gallon LN 2 tank on the West side of the main building failed and released LN 2 into the ceiling above several office areas A total of ~4000 gallons of LN 2 was released before the LN 2 flow was stopped The failure resulted from a joint clamp securing a bayonet connector. A bolt had rusted through after 30 years of use The large amount of LN 2 released froze a water pipe and a sprinkler system riser pipe. The frozen pipes cracked and released a large amount of water through the ceiling and into the office space below There were no injuries 1708-0109 / 14

Incident Location Red = Covered by ceiling Orange = Exposed LN2 tank LN2 line through concrete wall to ceiling of office area LN2 lines 1708-0109 / 15

Incident Time Line ~ 2:00 am LN 2 leak began, the level of LN 2 in the tank began a sharp drop 3:18 3:26 Room smoke detector starts giving Trouble faults (not an Alarm). 4:00 GA Security Guard arrives on site. Acknowledges fault. Walks around outside of building looking for smoke. ~ 4:30 GA Security contacts DIII-D management, reports that the smoke detector is in Trouble (not Alarm), and there was no smoke on this walk around the facility. DIII-D management told them smoke detector would be checked in the morning. ~ 4:55 Technician arriving on site and sees fog as they pass by the affected office area. The technician sees frost on the cement floor above the leak. Technician opens exterior doors for ventilation. ~ 5:00 The technician suspects a cryogen leak and contacts the Cryo Operator who goes to the Cryo control room to start LN 2 shut down. ~ 5:10 The Cryo Operator starts shutting down systems that use LN 2. ~ 5:30 Technician rope off affected office area. ~ 5:56 Cryo Operator shuts off LN 2 by hitting emergency stop button (LN 2 tank level stops dropping) ~ 6:45 am After arrival of additional staff, technicians get O 2 meter before entering affected office areas. When levels read low, blowers are setup to ventilate rooms. 1708-0109 / 16

Loose Bayonet Connector 1708-0109 / 17

Stainless Steel Clamp with Carbon Steel Bolt 1708-0109 / 18

Preliminary Analysis Proximate Cause: Failed carbon steel bolt on clamp for bayonet connector. The bolt that failed was 30 years old, exposed to the outside climate, and not inspected since it was installed in the ceiling. Lines are double jacketed with a vacuum inter-space except at the bayonet connector Severity of Problems: Exposure to LN 2 could cause extreme cold burns. GN 2 gas a possible asphyxiation hazard Alarms: There was not an alarm that unambiguously alerted to operators of the failure Response: Knowledgeable technicians quickly identified the problem. Appropriate actions were taken to eliminate the problem. Safety Training and understanding of the key systems were key in resolving the problem safely 1708-0109 / 19

LN 2 Leak: Corrective Action Replace failed bolt with stainless steel bolt. Inspect the other bayonet connectors and replace any suspect bolts Building entrance sealed to keep moisture off bolt Yearly inspection of all bayonet connectors on LN 2 line has been added to the preventative maintenance schedule. Access panels in the roof have been added to inspect the bayonet connectors Rate of change alarm of LN2 tank level added to Cryo Programmable Logic Controller (PLC). Output wired to Alarm System that is monitored by Security Guards Thermocouples installed at bayonet fittings to detect leaks. Wired to Cryo PLC which will generate an output to the Alarm System 1708-0109 / 20

LN 2 Leak: Corrective Action (cont.) Add additional oxygen monitors in rooms through which a GN 2 or LN 2 line runs. Wire to Alarm system. Also investigating adding voice alarms to oxygen alarms to alert personnel to leave the area as already has been done in other locations at DIII-D Provide training to a more general audience on the hazards of oxygen deficient atmospheres due to nitrogen displacement, i.e. train a wider audience than just LN 2 users and gaseous N 2 users. Include in training locations of LN 2 tanks, lines, and indications that LN 2 may be present 1708-0109 / 21

Outline Overview of the DIII-D Facility DIII-D Safety Program Review of Recent Incident: LN 2 cryogenic leak Ongoing Improvements to DIII-D Safety Program 1708-0109 / 22

Safety Upgrades in an Older Facility Access Control for hazardous areas is accomplished through locks and Kirk Key Control As a secondary measure door interlocks are installed. Areas are divided into sections with interlocks wired in series with a single interlock for each area running to the Main Control Room. This interlock is ORed and then sent to an Emergency Crash System (ABORT) which turns off power supplies and opens breakers Wiring is old (>30 years) and not well documented. Adding on new areas can be difficult. Serial wiring makes troubleshooting difficult Investigating Distributed Safety System to incrementally add-on and begin piecemeal replacement Versafe from GE as add-on to existing Profinet linked PLC drops SIL-3 rated hardware Programmable functionality. Increased Diagnostics 1708-0109 / 23

Group Wide Safety Meetings Held to Build Safety Culture Division wide input requested for safety issues. A list of action items was developed and is being pursued Improve the training of non-diii-d personnel (janitors, Security personnel, etc) Revise existing Lock-Out/Tag-Out DIII-D procedures. New procedure should require: Improved written, system specific procedures written and approved Easy availability of system-specific procedures (local & on-line) A Task Group was formed to update the After Hours work/lone worker procedures A Task Group was formed to update the Pit Run procedures. DIII-D runs pulsed shots. Access to the Machine Hall Pit is allowed between shots to adjust and diagnose experimental hardware 1708-0109 / 24

Summary DIII-D has a successful system for assuring safe and efficient operations Hazards identified for each task and mitigation is put in place to protect personnel & equipment Safety training for all personnel is regularly evaluated, provided on an on-going basis, and tracked Processes and procedures in place to control work Lessons learned from investigations of both injuries and near miss incidents have significantly improved the safety program Wide use of engineered controls are key to strong safety record at DIII-D Most injuries result from common industrial-type hazards training and safety awareness is key Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. 1708-0109 / 25