Installation Manual for isodrive 1600 Motor

Similar documents
Installation Manual for isodrive 650 Motor

Installation Manual for BR500

INSTALLATION GUIDE. Isodrive / V1.0

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

INSTALLATION GUIDE. Isodrive Revision V1.1. HOME APPLIANCES

INSTALLATION GUIDE. Isodrive Revision V1. HOME APPLIANCES

INSTALLATION GUIDE. Isodrive / V2.0

FACT BOOK. SILENT RANGEHOODS New Zealand s Quietest, Strongest & Most Efficient Rangehoods

SILENT RANGEHOODS New Zealand s Quietest, Strongest & Most Efficient Rangehoods

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS

RANGEHOOD & INSTALLATION GUIDE GG-6C. Revision V1.

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

RANGEHOOD & INSTALLATION GUIDE NAUM-9. Revision V1.1.

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS

Wall Mounted BBQ GRHM & GRHL

Rangehood & installation guide

Wall Mounted BBQ Rangehood

Installation instructions. and User guide. Slideout rangehood NZ AU. HS60CSRX2, HS60CSRW2, HS90CSX2, HS60CSW2, HS60CSX2, HS60CIW2, HS60CIX2 models

SILENT RANGEHOODS Australia s Quietest, Strongest & Most Efficient Rangehoods

INSTALLATION INSTRUCTIONS USER GUIDE

CLASSIC SILENT RANGEHOODS. wall canopies / undermount rangehoods ceiling cassettes / island rangehoods bathroom extraction silent motor systems

INSTALLATION INSTRUCTIONS USER GUIDE

World s Most Innovative Rangehoods. Classic Series

GUH90 90 cm Canopy Hood

Installation instructions. and User guide. Freestanding canopy NZ AU. HF60CSW2 & HF60CSX2 models

Installation instructions. and User guide. Designer wall glass canopy NZ AU. HC90CGX1 & HC60CGX1 models

Falcon Undercupboard Rangehoods Installation Instructions & User Guide

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING REMOTE FAN MOTOR UNITS

fñxv tä VÉÅÅxÇwtà ÉÇ The DraftStoppa TopHat AT200D DraftStoppa TopHat AT200D(240V) Product of the Year

KADO LUX LED EXHAUST FAN 200

Installation instructions. and User guide. Wall canopy NZ AU. HC60PCIX2 & HC90PCIX2 models

Kind Regards, The Residentia Team

MILLI CUBE HEATED TOWEL RAIL 825 X 600

Black Fascia & Auto Slide-Out Canopy Range Hood

World s Most Innovative Rangehoods. Classic Series

ERR627SA ERR927SA. Rangehood Installation manual

Lo-Carbon Quadra Centrifugal Fan

Installation instructions. Designer series wall canopy. and User guide NZ AU GB IE. HC90DXB1, HC90DMB1 models

TILE ROOF DUCTING KIT. instruction manual VDKRT 12 MONTH WARRANTY

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Important: Retain these instructions for future use.

ORC93XA ORC94XBA. Wall Canopy Rangehoods

User Manual\ Canopy Rangehood\ RH92G\RH92GB\RH62GB

Model pictured: RPA3CI6SS/WH

Instructions for the Use and Care and Installation of BRSH60X BRS90X BRS602W BRS902X BRS902W BRSH90X. Slide Out Rangehood.

Mini oil filled radiator OR320-6

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

USER MANUAL COOKING. Model: WRG920FGS. Rangehood

Centrif Duo & Centrif Duo Plus

RSA2CL6SS model pictured

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: RHC60IX, RHC90IX. All dimensions in mm Model may vary slightly from images pictured

Lucci Designer Hi Flow Exhaust Fan

FLUEBOOST. flueboost 350 gas fire model

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

"Let's provide you with a superior User Experience delivering Ease-of-Mind."

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Installation and Maintenance

Instructions for the Use and Care and Installation of ORU52X ORU70X. Undermount Rangehoods CONTENTS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

USE, CARE AND INSTALLATION INSTRUCTIONS FOR YOUR NEW CANNON HORIZON HEATER

Brivis Inverter Icebox

Index. Undermount The 6 Cornerstones of Schweigen 4. Glass 24. Ceiling Cassette Catalonia 26. Paradigma 6. Information

DESIGNER WALL CANOPY

Installation and Maintenance

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

GUH52SD 52 cm GUH75 75 cm Canopy Hood

Lo-Carbon Quadra SELV

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Instructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood

Exhaust Duct Design Page 1 of (C)

Installation and Operating Instructions. Models: T4-12LOW-9IS-1

Black Glass Fascia Rangehood. Curve Glass Canopy Rangehood. Canopy Rangehood. Installation and User manual. Content

REHR6* WRH605I* WRH608I* WRR614*A WRH908I* Retractable Rangehood User manual

Instructions Manual SHC520X - SHC700X

Lo-Carbon Quadra Centrifugal Fan

Airflow. Add a little Sunshine to your bathroom

Operating Manual HD01

SLTC919 UNDERMOUNT RANGEHOOD INSTALLATION INSTRUCTIONS

Model pictured: RCB2AH6WH/SS

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Turbo Circulating Fan (DC)

Installation instructions. and User guide. Slideout rangehood NZ AU. HS60CIWX3, HS90CIWX3, HS60CSX3, HS90CSX3, HS60CSRX3 models

USER MANUAL CANOPY RANGE HOODS - SLIM LINE ACS60AX-L, ACS90AX-L, ACT60AX-L & ACT90AX-L

Self-Cleaning Range Hoods

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Lo-Carbon T-series Window & Roof Models

OWNER S MANUAL Compact Portable Refrigerated Air Conditioner CP35CW1

Electrician Installation Manual Majestic Madagascar Ceiling Fan

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

PROLUXE SALON STRAIGHTENING BRUSH

Installation and Maintenance

READ AND SAVE THESE INSTRUCTIONS

Bathroom Exhaust Fan

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

Transcription:

Installation Manual for isodrive 1600 Motor Important Notice Do not install this appliance if you find it damaged! Please inspect this product upon receipt. Any damage or defects MUST be reported within 24 hours otherwise no claim will be recognized. If this product is installed damaged, neither the supplier, nor retailer, will be responsible for the costs associated with the repair, replacement or removal and re-installation of the appliance. All enquiries regarding these products should be forwarded to our International Agents as listed. The manufacturer cannot be held liable for damage resulting from incorrect or improper user or operation. Schweigen reserves the right to change the specification without notice. Roof flashing (Dektite) and duct tape are not included. Please supervise the elderly the infirm and children when using this appliance this refers persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. Children should not play with the appliance, it is not a toy. HOME APPLIANCES Schweigen Pty. Ltd. P.O. Box 471 Maylands WA 6051 Ph: 1300 881 693 Fax: 1300 881 639

This manual is for the installation of the motor used in the ISODRIVE systems after the canopy/ rangehood or bathroom extraction grill has been mounted on the wall or ceiling. (Refer to canopy/rangehood or bathroom extraction unit installation manual) Motor Features Roof and wall mounting with IPX4 degree of weather protection. Super quiet, long vane, backward curved centrifugal fan. Airflow is dependant on installation and the ducting used. Using a single 200mm flex duct run you should attain up to 1600m 3 /hr depending on the ducting installation. The use of a smaller 150mm pipe would result in a loss of airflow. Simple installation: mounts onto a 150mm PVC stormwater pipe for ultimate strength and allows for easy Dektite roof sealing. Industrial quality motor and fan made in Germany and rated at 40,000 hours. Motor is a high efficiency PSC type and rated at 135W costing around the same as two 70W light globes to run. Warranty 10 years return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear. General Notes on Installation and Use This fan unit is designed to be installed using 150mm PVC pipe as the initial connection duct to the fan module, and is supplied with a 150mm PVC pipe to 200mm flexible duct bell-mouth adaptor. This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm 2 and length up to 20 metres (check with supplier if longer duct length required). Where possible flexible ducting must be extended sufficiently to present a smooth air passage with bends of at least the radii of twice the diameter of the duct. Warning: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential fire risk. Note: Fan module and dual foil flexi-duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and void warranty. See installation instruction notes Why flexi-duct. Recommended Installation Distance 1600 motor: Recommended 5 metres or more of flexi ducting. Note: Although less than 5 metres will increase extraction power this will result in higher noise level. Maximum duct length 20 metres. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends. Minimum Mounting Height This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a floor or the ground. Page 2

Avoidance of Back Flow Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire appliances. Safety of Children This fan is not intended for use by young children or infirm persons without supervision. Replacement of supply cord If the supply cord is damaged, it must be replaced by a service agent or suitably qualified person in order to avoid a hazard. Why Flexi-duct Some internet sites strongly recommend the use of rigid ducting over fully flexible ducting. This may well be the case with conventional rangehoods with in hood fans. Schweigen s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting producing almost silent high volume flow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping effect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplified out the other. The Isodrive system puts the noise outside the house and it needs to be kept there. Warning: Installation without the use of at least the minimum recommended length of acoustically matched flexi-ducting in the system will void performance expectations. Any installation problem must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation. Faulty installation may void warranty. A preferred installer list can be obtained from Schweigen website www.schweigen.com.au or call 1300 881 693. Roof Installation (Recommended duct length: 1600 motor - 5m) Mount 150mm rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device. Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge, refer figure 1. Pass power cord and plug through mounting flange and pipe, then out the slotted PVC pipe for connection to the female plug coming from the canopy/rangehood Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and fix in position using side locking screw. Page 3

Figure 1 Roof Mount Option important Please take Note: For Flexible ducting instructions refer to Page 8 and 9 Wall Installation The installation is similar to roof mounting ensuring that the pipe extends at least 50mm past the wall surface refer figure 2. If the pipe length is shortened reproduce the power cord exit slot on the inside of the wall. Note: The weather shield must be fitted to the top cover side flange using the 3 screws provided. Page 4

Figure 2 Wall Mounting Option Page 5

Wall Installation Wall mounting instructions showing optional wall mounting flange fitment. Figure 3 important Please take Note: For Flexible ducting instructions refer to Page 8 and 9 Page 6

Flat Roof Installation Flat roof mounting using optional mounting flange. Figure 4 important Please take Note: For Flexible ducting instructions refer to Page 8 and 9 Page 7

Twin Motor Installation Where two motors are to be used, follow the method below each motor should have a separate flue pipe. Refer figure 5. The two motors can be wired by an electrician. ROOF MOUNT OPTION ROOF MOUNT OPTION USE SMOOTH FLOWING CURVES FOR MAXIMUM AIR FLOW. REMOVE EXCESS DUCTING BY TRIMMING TO LENGTH. MUST HAVE SEPARATE FLUE PIPE FOR TWIN FAN INSTALLATION CONNECT TO 150mm DUCT ADAPTOR COVER RANGE HOOD Figure 5 important Please take Note: For Flexible ducting instructions refer to Page 8 and 9 Page 8

Important Please take Note: Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. Installation should be done by a qualified technician. A preferred installer list can be obtained from schweigen website www.schweigen.com.au. Do not crush the flexi pipe 5 metres in length Please keep the flexi pipe taught In shallow roof spaces, extend the flexi pipe horizontally WARRANTY Isodrive motor has a 10-Year replacement product warranty. This is a change over warranty. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in this change over process. www.schweigen.com.au or call 1300 881 693 Page 9 2010 Larry Richards. Issue 3, July 2011 R3