This wiring harness allows you to connect the Windcrest Unit to a KONE lift with a KRM Communication system.

Similar documents
The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

AD1000EN-1R configured to operate as a DG1000

AVCOM System Installation Instructions

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

DESCRIPTION INSTALLATION

Model 4880 Status Output Display Module Manual

Memcom Emergency Telephone

ADE Gen4. Speech Dialler Engineering Information. Description. Features

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Unity DAU Voice Alarm System

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

380 SERIES REMOTE SIREN ETSA380R

TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY

GUIDE TO CONNECTIONS

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

CFDAU30 Voice Alarm System

Entero Voice Alarm system.

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

SECURIT 700L PLUS ENGINEERING MANUAL

Memcom + Emergency Telephone

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

REPEATER FS5200R OPERATION MANUAL

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

IL650 SECTION B Rev. 5-01/2002. Tek-SPEC Condensed Product Specification Catalog. Section B Residential & Commercial Intercoms

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Entero Voice Alarm system. User guide

Colour also can display the time Build a LED colour clock

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

RW8CA 8-Inch Low Profile Powered Subwoofer. RW10CA 10-Inch Low Profile Powered Subwoofer. User's Manual

Operation and Maintenance Manual

English. Doro CareIP Mobile. User Guide

Digital Door Entry System. Specification

Bosch Plena Public Address and Voice Alarm System The fast route to safety

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

EasyAlarm ELEVATOR LEITRONIC AG

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

OmniCare EVC System. Installation & Commissioning Manual

Matrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1

Fast Track Troubleshooting

D-TEK -MS Vehicle Loop Detector. Operating Instructions

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

INSTALLATION & OPERATION MANUAL 4000 SERIES SIRENS SIRENS WARNING

EL-OEM-3 OEM Packaged Voltage Data Logger

CURTIS GOLD CUP BREWER

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

Application Guide OE692-FD OE652-FD OE69C-FD OE65C-FD FORD & LINCOLN O.E.M. PLUG & PLAY

TECH SHEET - DO NOT DISCARD PAGE 1 DIAGNOSTIC GUIDE

ERS-3600B. PERS-3600B Personal Emergency Reporting System

Distributed Amplifier Unit (DAU) (EESDAU100) Emergency Microphone All Call (EMA) (EESEMA) User Operational & Maintenance Manual

Talking Calendar Alarm Clock with Cover

P2267 NETWORK INTERFACE

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Call stations and extensions

(Cabinet Automatic Fire Extinguishing System)

16 Zone Voice Evacuation VA & PA Sound System

! CAUTION. All safety information must be followed as provided in Service Manual ! WARNING

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

Digijock Home Security

ENGINEERED PARKING SYSTEMS MODEL 3416D

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

20 Light Remote Annunciator

Fratech Multipath-IP

KP: Charge Air Cooler (CAC) Pump

SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL

THE COMMISIONER TM 200 WATT ELECTRONIC SIREN & PA SYSTEM Model 4200

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

! CAUTION All safety information must be followed as provided in Service Manual ! WARNING

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless testing requires power.

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

N-8000 SERIES IP INTERCOM SYSTEM

Excel-EN Conventional Fire Control Panel

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

QA16 Addressable System

Informer-IP Desk Mount

An introduction to... Sigma

Sidekick II Receiver Model # SK2-SS 418MHz

Fast Track Troubleshooting

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

FUN WITH DIGITALS. Experimental Examination, IMSO 2007, Jakarta, 14 November 2007 Name: ; Country:

ANC BBX-FXMNS or BBX Audio Network Controller Board Installation Instructions TNC-5000 ANC Module Mounting Locations

PREMIER EVACS 1-16 INSTRUCTION MANUAL: 2-ZONE NETWORKED VOICE ALARM PANEL INSTALLATION MANUAL

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Smoke Check Service Manual

Transcription:

Introduction This wiring harness allows you to connect the Windcrest Unit to a KONE lift with a KRM Communication system. The following procedures need to be carried out to minimise the installation time on site:- 1. Switch OFF Mains and disconnect the Backup batteries, sounder and BT phone line and then anopen the Connection Box on top of the lift car. 2. Once the top of the car box is Opened, Identify that the lift communication system you are working on by looking for a for a pcb which looks like the drawing on page 2 of this document. 3. Assuming you have confirmed that the lift car has the correct version of the communication equipment, ie a KRM system you can proceed. 4. Open the Car Operating Panel, and install the Microphone, and the in the moulding. Use the rubber gasket over the speaker to improve the sound quality and volume. 5. Push the cable of the Microphone and through to the top of the lift car and connect to the Windcrest box interface. 6. Unplug the 14 way Connector X12 and attach the wires necessary as defined in the drawing on page 3 of this document. 7. Once connected, recheck the wiring and then plug in the back up battery, and switch ON the Mains. & Play Harness. 8. Programme the Windcrest unit in the usual way and carry out the testes to confirm all is working correctly. 9. Finally, during installation you may trigger the Kone communication equipment which can be reset by unplugging connector for 5 seconds and then re-plugging it back. KONE KRM Wiring Drawing: P&P Kone KRM 1/5

KONE KRM Existing Factory Arrangement in the Top of Car Connection Box (Kone Dg No.812301E24) Drawing: P&P Kone KRM 2/5

Voice Link 25 ohm Speech Synthesis Yellow Blue Pink GRAY KONE Top of Car Connection (Kone Dg No.812301E24) BLUE YELLOW Pins on XC9B must be shorted. + - A ALARM PUSH INTERFACE UNIT * Push NC C NO NC C NO NO BT G Y PF LINE Lamp PUSH Ser Eng Q A A M + T C + P - - + T s BATT AC Drawing: P&P KoneKRM 3/5

Voice Link 25 ohm BOE 1000SDV KONE Top of Car Connection for a BOE1000 System (Kone Dg No.812301E24) Pins on XC9B must be shorted. + - A ALARM PUSH INTERFACE UNIT * Push NC C NO NC C NO Drawing: P&P KoneKRM 4/5

Voice Link 25 ohm Part No. SPKDUEL40 This box Assembly has the facility to use the Internal and Microphone or the External and/or Microphone (The drawing shows both being used to show wiring position only and not for normal operation) KONE Top of Car Connection (Kone Dg No.812301E24) BLUE YELLOW If an IL01 is NOT USED you can Wire Directly as Shown Pins on XC9B must be shorted. NO BT G Y PF LINE Lamp PUSH Ser Eng Q A A M + T C + P - - + T s BATT AC Drawing: P&P KoneKRM 5/5

Voice Link 25 ohm Part No. SPKDUEL40 Cable for the Amplified This box Assembly has the facility to use the Internal and Microphone or the External and/or Microphone (The drawing shows both being used to show wiring position only and not for normal operation) KONE Top of Car Connection (Kone Dg No.812301E24) BLUE YELLOW If an IL01 is NOT USED you can Wire Directly as Shown Pins on XC9B must be shorted. NO BT G Y PF LINE Lamp PUSH Ser Eng Q A A M + T C + P - - + T s BATT AC Drawing: P&P KoneKRM 5/5 B L A C K