Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

Similar documents
PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Gas cylinder scale Model GCS-1

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

M2500 Engine Controller Installation Manual

Engineering Guideline. pac- Carriers Type Universal

SPACEMOTION SERIES SMM 01

Snifter ATEX22 VERSION. User Manual. Distributor

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

PolyGard 2-channel Gas Controller MGC-03

Room Temperature Controller

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Pump-Up Controller MODEL 4062

PROFIBUS-PA Display RID 261 PROFIBUS-PA

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

ACS-30-EU-EMDR- 10-MOD

Pump-Down Controller MODEL 4052

1.7. Insulation fault evaluators EDS460/490 EDS461/491

High-Intensity cd Aviation Light

S304 and S305 Dust Emission Monitors. User Manual. Distributor

XLH210: controller for gas leak detectors

for relative humidity and temperature

Alarm Panel Operating Instructions

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

OPTISENS TUR 2000 Technical Datasheet

RE-PR3-E-27 3-Phase Panel Mount 27kW

for relative humidity and temperature

5, SE GÅNGHESTER,

ADC150 Automatic Draft Control

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Remote alarm indicator and test combination MK2430

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Retroreflective sensor with polarization filter

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

DICTATOR Hold-Open Systems for Hazardous Areas

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

Temperature Controllers

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

Oxygen (O2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Operating Manual MS220DA

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

LC2200 Level Controller Installation and Maintenance Instructions

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

02/11/2015

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Installation, Operating and Maintenance Manual

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

INSTRUCTION MANUAL (ATEX / IECEx)

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Carbon Monoxide CO Transmitter ADT-X3-1110

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

EBC 12 Modulating Fan Control

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Operating Instructions SUPERSTAR E-6000 / F2 for 1 1/2, 2 and VAC

43.155/1. RXE 110: Monitoring unit for fume cupboards. Sauter Components

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Room Temperature Controller

02/11/2015

Dräger Polytron 5100 EC Detection of toxic gases and vapors

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

OPERATING INSTRUCTIONS MAXIMAT LW CX COMPACT LEAKAGE SENSOR

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Installation and Operation Instructions

WARNING FIRE DOOR CLOSING

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Sierra Series 900 Single & Dual Channel System. Instruction Manual

MD12-1 Vehicle Loop Detector

SMP 19160, SMP 29160

Model 4001 Series Single Channel Controller

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Two-Channel Gas Controller

Operating Instructions

Flopurge TS. Operation Manual

SCHMIDT LED Measured Value Display MD Instructions for Use

BLAUAIR AUTOMATIC CONTROL SYSTEM

PHOTOELECTRIC AMPLIFIER SERIES

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

TEMPERATURE CONTROLLER

Table of Content LT 5165-UL

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Duct Temperature Sensors

Wind Alarm Instrument

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

MBCE-110/230UV Flame Sensor Module

Installation Instructions

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

ER65 - Mini Rack Controller Electronic Refrigeration Line

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

Transcription:

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P with integrated pressure sensor - Art-No.: 30588 / mit eingebautem Drucksensor - Art-Nr.: 30588 GB DE Operating instructions DVC-P 2-13 Bedienungsanleitung Druckregler DVC-P 14-25 Systemair GmbH Seehöfer Str. 45 D-97944 Boxberg-Windischbuch Phone: +49 (0) 7930/9272-0 Fax: +49 (0) 7930/9272-92 info @ systemair.de www.systemair.de

Contents Terminals and Pin Technical data 3 Terminals and pin configuration 4 Setpoint adjustment 6 Factory-made wiring 1~ / size 225 P - 400 P 7 Factory-made wiring 1~ / size 450 PK 8 Factory-made wiring 3~ / size 450 P - 630 P 9 Connection of pressure sensor pipes 10 Connection of external potentiometer setpoint adjustment 11 Connection of external clock timer 11 Air flow calculation 12 Dimensions 13 2

Terminals and Pin Technical data Rated voltage Line frequency Max. input power P1 Control range Maximum pressure Medium Interference emission Interference immunity Leakage current Protection class 100-277 V AC 50/60 Hz 3 W 50-500 Pa 200 mbar air, neutral gases EN50081-1 EN61000-6-4 < 3,5 ma IP55 Mounting and electrical connection may only be done by authorized and trained personnel and in accordance with valid regulations. All general rules regarding safety of work have to be respected. 3

Pin Function Terminals and Pin Terminal 1 PE L N PE connector Mains 50/60 Hz, Phase Mains 50/60 Hz, neutral connecto Terminal 2 PE PE connector L Mains 50/60 Hz, Phase N Mains 50/60 Hz, neutral connector * Terminal 3 Terminal 4 Terminal 5 Terminal 1 and 2 are internal linked to loop the line supply to the fan. NC COM NC COM Alarm relay NC Alarm relay COM Alarm relay NC Alarm relay COM * Internal linked to loop signal from fan to system control. Selector input to activate the pre-set NIGHT setpoints DAY and NIGHT. The inputs are low-active. DAY External potentiometer 0-10V External potentiometer +10V External potentiometer Supply 10V (-10%), 10 ma OUT 0-10V output for open-loop control of fan Tacho Tacho output from fan not connected Terminal 6 4 20V IN DC Voltage (optional) with reverse polarity protection

Terminals and Pin DIP- P1 DAY P2 NIGHT switch DIP-switch This setting is recommended for pressure control with constant- as well as with variable air flow. Adjustment only factory-made. No local adjustment necessary! P1 DAY Setpoint adjustment Connected over terminal 4 DAY P2 NIGHT Setpoint adjustment Connected over terminal 4 NIGHT LED Advice state of readiness 5

Setpoint adjustment Factory-made there is a bridge on terminal 4 between DAY and. Therefore potentiometer P1 DAY is activated and there is the setpoint adjustable. To guarantee protection class IP55 it is necessary to close the housing correctly! 6

Factory-made Wiring 1~ / Size 225 P - 400 P 200-230 VAC 50/60 Hz 7

Factory-made Wiring 1~ / Size 450 PK SUPPLY 200-277 VAC 50/60 Hz Terminal motor control side Pin Function RS A RS485 interface for ebmbus RS B RS485 interface for ebmbus 0-10V Control-/actual value point 4-20mA Control-/actual value point +20V Supply for ext. sensor DC (+/- 20%)@50 ma +10V Supply ext. potentiometer DC (+10%)@10 ma Terminal motor supply side Pin NC COM NO L1 N PE Function Alarm relay, break for failure Alarm relay, Common (2A, 250VAC, AC1) Alarm relay, make for failure Mains 50/60 Hz, Phase Mains 50/60 Hz, neutral connector PE connector 0-10V Control-/actual value point 8 OUT Master output 0-10V max. 3 ma

Factory-made Wiring 3~ / Size 450 P - 630 P SUPPLY 380-480 VAC 50/60 Hz Terminal motor control side Pin Function RS A RS485 interface for ebmbus RS B RS485 interface for ebmbus 0-10V Control / actual value input 4-20mA Control / actual value input +20V Supply for ext. sensor DC (+/- 20%)@50 ma +10V Supply ext. potentiometer DC (+10%)@10 ma 0-10V Control / actual value input Terminal motor supply side Pin NC COM NO L1 L2 L3 PE Function Alarm relay, break for failure Alarm relay, Common (2A, 250VAC, AC1) Alarm relay, make for failure Mains L1 Mains L2 Mains L3 PE connector OUT Master output 0-10V max. 3 ma 9

Connection of the Pressure Sensor Pipes <<Grey: + (higher pressure level) atmosphere <<Blue: - (lower pressure level) duct The factory-made plug must be removed! 10

Connection Accessory optional Connection of external potentiometer for setpoint adjustment L N Connection of external clock timer via DAY- und NIGHT-contact 11

Air flow calculation Positioning of sensor Size Open diameter 190/225 0,034812 m² 310 0,042768 m² 355 0,139150 m² 400 0,099478 m² 450/500 0,139105 m² 560/630 0,285299 m² Example: 3 m/s x 0,285299 m² = 0,856 m³/s 12

Dimensions In order to make sure the pressure control unit operates proberly, only two mounting positions are recommended: 1.) Horizontal installation with mounting angle facing down 2.) Vertical installation with pressure terminals facing down 13

Artikel-Nr. / Stand 03/2008 26