Catalogue Telecommunication Cables INTRODUCCIÓN

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

BS /1000V XLPE Insulation LSZH Sheath Cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Tratos Railway Cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

OIL & GAS INDUSTRY OTHER INDUSTRIES

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

FIRE RESISTANT CABLES

PRODUCT CATALOGUE Norröna

Caledonian Flame Retardant Coaxial Cables

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Havells Fire Survival Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Flexible Power Cable DLO

High Performance LSZH Fire Resistant Cable

Total Fire Solutions. Includes BS 8519 and the updated BS :

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Caledonian Fire resistant Coaxial Cables

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Multi-Core Fire Resistant Cable

A Look at General Cable s GenFree II Product Line

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

CONNECTION SYSTEMS TRANSIT APPLICATIONS

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Power Control Cable Iec

SOLAR CABLES. Electric cables for solar PV installations

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Evolution of Cable Fire Safety Standards in Australia

fire resistant cables

Low Smoke Zero Halogen

Compact Module. Category 6A FTP Cabling System 1.1

SAS Security and Alarm Safety Cables

FIRE RESISTANT CABLES FP300

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Cable technology for highest safety requirements

LV FIRE RESISTANT CABLES

THE TRUE FIRE SURVIVAL CABLE

INSTRUCTION DE IS 23 SÉCURITÉ Rev. 2 SAFETY INSTRUCTION

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

The Quality Connection. BETAflam Fire Resistant Safety Cables

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Wires, Cables, Cords and Adhesive Tapes

Nuclear Power Plant LSZH Cable Overview

STANDARDS INSTALLATION. Certificate No 077m

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Introduction.

ENHANCED FIRE PERFORMANCE CABLE

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

SECTION ELECTRICAL GENERAL PROVISIONS

INTERNATIONAL STANDARD

Caledonian fire Resistant signal & Data cables

Photovoltaic Cables EN H1Z2Z2-K

Fire Resistant Cables

Firecel Safety Cables

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

QUALITY THROUGH EXPERIENCE

FIRE RESISTANT CABLES FP400

DNVGL-CP-0399 Edition March 2016

Caledonian. FIREFLIX ire Resistant Coaxial Cables

INTERNATIONAL STANDARD

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

STUDY ON THE REACTION TO FIRE OF MEDIUM VOLTAGE CABLES SYSTEMS

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

FIRE PERFORMANCE CABLE

PRODUCT RANGE.

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

More than Just a Cable Supplier

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

DNVGL-CP-0401 Edition February 2016

Cablosam Tapes for Fire-Resistant Cables

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

SPECIAL ELECTRICAL AND OPTICAL CABLES

HELKAMA. Optical Fibre Cables

Sensor and transducer cables

ITU-T L.63. Safety practice for outdoor installations

CABLES FOR ALARM AND SAFETY SYSTEMS

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

(Notices) EUROPEAN COMMISSION

Transcription:

Power Cables

Power Cables Page Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7 ELECWIRES 2 www.elecwires.es

INTRODUCTION Power Cables Power cables for electrical installations, domestic & industrial, specifically designed for supplies with a 0.6/1 kv voltage service range in energy & control applications. The most commonly used configurations are: RV. Unarmoured Cables RVMV. Steel Wire ed Cables RVSV. Corrugated Steel Tape ed Cables RVFV. Steel Tape ed Cables According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN 50200 y UNE-EN 50362 Fire retardant. IEC 60332-3-24 Cat. C (UNE-EN 60332-3-24 Cat. C) Flame retardant. IEC 60332-1-2 (UNE-EN 60332-1-2) Low Smoke Emission. IEC 61034-2 (UNE-EN 61034-2) Halogen free. IEC 60754 y UNE-EN 50267 OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN 60811-2-1 & UIC 895 OR Configurations with different types of armours and materials ELECWIRES 3 www.elecwires.es

POWER CABLES RV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 y 5 Sections: from 0,5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) y otros. Assembly Cabled in concentric layers. Outer Sheath *OPTION, Hydrocarbon and mineral oil resistant plastic compounds and LSZH thermoplastic (Low Smoke Zero Halogen). APPLICATION & PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. Suitable for outdoor and indoor services, they can be installed in ducts, trays or conduits. STANDARDS: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant ELECWIRES 4 www.elecwires.es

POWER CABLES RVMV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0,5 to 400 mm 2. *OPTION, aluminium. *OPCION, composition acc. To AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Popylene), PVC (Policloruro de Vinilo) and others. Assembly Cabled in concentric layers. Inner Sheath Galvanized steel wires. *OPTION, aluminium wires. Outer Sheath resistant plastic compounds and LSZH thermoplastic (Low Smoke Zero Halogen). APPLICATION Y PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The steel armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN 60228 Flame retardant UNE-EN 60332-1-2 IEC 60332 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium wires ELECWIRES 5 www.elecwires.es

POWER CABLES RVSV 0,6/1 KV CONSTRUCTIÓN: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath Steel corrugated tape. Thickness: from 0.15 to 0.50 mm. *OPTION, Aluminium corrugated tape. Outer Sheath APPLICATION Y PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour provides very high mechanical and anti rodent protection. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium corrugated tape ELECWIRES 6 www.elecwires.es

POWER CABLES RVFV 0,6/1 KV CONSTRUCTION: Conductors Annealed or tinned electrolytic copper. Classes: 1, 2 & 5 Sections: from 0.5 to 400 mm 2. *OPTION, aluminium. *OPTION, composition acc. to AWG (American Wire Gauge). XLPE (Cross linked Polyethylene). *OPTION, EPR (Ethylene Propylene), PVC (Polyvinyl Chloride) and others. Assembly Cabled in concentric layers. Inner Sheath Steel tape helicoidally placed. Thickness: from 0.15 to 0.50 mm. *OPTION, aluminium tape helicoidally placed. Outer Sheath APLICATION & PROPERTIES: Power cables for power supply connections, electrical substations, distribution networks, lightning networks and civil & industrial installations in general. The armour of steel tape helicoidally placed provides very high mechanical and anti rodent protection with high flexibility. Suitable for outdoor and indoor services, they can be installed in ducts, trays, aerial or direct burial. STANDARDS: Construction UNE-EN 60228 Flame retardant UNE-EN 60332 IEC 60332-1-2 *OPTIONS (others available under request) Conductor Sheaths Tinned copper and aluminium Materials Fire resistant Mineral oil & HC resistant Aluminium tape helicoidally placed ELECWIRES 7 www.elecwires.es