PROCEEDINGS SOLAR 95

Similar documents
Falling Film Heat Exchangers for Solar Water Heaters

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

2. HEAT EXCHANGERS MESA

Performance of an Improved Household Refrigerator/Freezer

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

In the name of God. Jami Institute of Jami - Mehdi Rasti

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

New Convection Correlations for Cooled Ceiling Panels in Room with Mixed and Stratified Airflow

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

NUMERICAL AND EXPERIMENTAL ANALYSIS OF A DEMAND-SIDE HEAT EXCHANGER FOR DOMESTIC HOT WATER HEATING

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle

AR/IA 241 LN 231 Lecture 6: Passive Cooling

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

SOLAR COMBISYSTEMS IN DENMARK - THE MOST COMMON SYSTEM DESIGNS

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Pocket Dilution Cooler

Design and Development of Water Cooled Condenser for Domestic Refrigerator

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Compression of Fins pipe and simple Heat pipe Using CFD

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Residential Building Walls and Environment in Amman, Jordan

K.F. Fong *, C.K. Lee, T.T. Chow

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

To investigate the surface properties for increasing efficiency of solar water heater

Optimizing Electric Humidifier Operation with an Air Side Economizer

Development of a Compact High Efficiency Cooling Device for the PA8000 Processor*

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

A SIMPLIFIED MODEL FOR SIZING AND CHARACTERIZING A NATURAL CONVECTION HEAT EXCHANGER SYSTEM

Performance Study of Triple Concentric Pipe Heat Exchanger

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Basic CFD model of heat pipe

Efficiency of Non-Azeotropic Refrigerant Cycle

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS

Investigation and Optimization of Air Cooled Condenser of Chillers by Replacing Cu to Al Tubes

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Mechanical Engineering Department Sheet (1)

Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Copyright 2003 IBACOS, Inc. All rights reserved.

TRNAUS 14.1 TRNSYS EXTENSIONS FOR SOLAR WATER HEATING. Graham L Morrison. February 2014

ω = (1) Kirby S. Chapman Ph.D.

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Experimental Investigation of Tube Configuration for a Surface Condenser

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Heat transfer and heating rate of food stuffs in commercial shop ovens

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

ENSC 388: Engineering Thermodynamics and Heat Transfer

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Characterization of Acoustic Burst in Household Refrigerators

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

of the liquid prior to it entering the expansion device. By doing so, the capacity for

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Numerical study of heat pipe application in heat recovery systems

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

DYNAMIC THERMAL MODELING OF A RADIANT PANELS SYSTEM AND ITS ENVIRONMENT FOR COMMISSIONING: APPLICATION TO CASE STUDY

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Development Of A Low-Cost Heat Pump Water Heater For Residential Applications

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Analysis of the performance profile of the NCERD thermosyphon solar water heater

Transcription:

PROCEEDINGS OF SOLAR 95 THE 1995 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE Minneapolis, Minnesota July 15-20,1995 Editors: R. Campbell-Howe B. Wilkins-Crowder American Solar Energy Society 2400 Central Avenue, Suite G-l Boulder, CO 80301 Printed on recycled paper

ANALYSIS OF A LOAD-SIDE HEAT EXCHANGER FOR A SOLAR DOMESTIC HOT WATER HEATING SYSTEM Toni R. Smith Patrick J. Bums Douglas C. Hittle Colorado State University Mechanical Engineering Department Solar Energy Applications Lab, SH II Fort Collins, CO 80523 ABSTRACT The Colorado State University Solar Energy Applications Laboratory is currently testing several solar domestic hot water systems. The experimental systems are fully instrumented to yield all data appropriate for in-depth analyses of performance. One of these systems is an unpressurized drainback system with a load-side heat exchanger. An analysis of the performance of this heat exchanger is the focus of this paper. Analytical calculations for the effectiveness and convective heat transfer coefficients from correlations are compared against the experimental data. The convective correlations yield heat transfer coefficients that under-predict the measured by as little as 17% and as much as 72%. TRNSYS simulations were performed using the average effectiveness; the results compare favorably with experimental results, indicating that a constant effectiveness is an adequate model for the system. 1. INTRODUCTION Load-side heat exchangers are used in solar domestic hot water heating systems for several reasons. One such reason is to allow the use of an unpressurized storage tank; thus, a drainback system (to avoid freezing of the lines to and from the collector) could be used. Also, if the system is unpressurized, then the collectors can be designed for lower pressures. The use of a load-side heat exchanger eliminates the need for a pump on the load delivery side. The system tested is shown in Figure 1. To transfer the heat from the solar storage tank to the load water, mains supply, shown as point A, travels to point B via a dep-tube, and then is circulated through the coil that is submerged in the solar storage tank. The water enters the auxiliary tank at point C. This arrangement may also promote stratification, depending on the location of the coil, which can increase collector performance [Farrington and Bingham, 19871. This type of heat exchanger operates only when a draw is occurring and is a one-pass system. In support of the Solar Ratings and Certification Corporation s (SRCC) ongoing work, validation of the model of the load-side heat exchanger is important. 2. SYSTEM DESCRIPTION AND INSTRUMENTATION A comprehensive system instrumentation plan has been designed to effect system measurements of temperatures, electrical power input, flow rate, and differential pressure across the pumps. In addition, an outdoor ambient weather station has been designed and installed specifically for these tests. Measurements from the ambient weather station constitute inputs while system measurements constitute system states and outputs. A detailed test of the systems under actual operating conditions is the intent of these experiments. Outdoor and system measurements are made as indicated in Figure 1. Measurements are taken every 8 seconds. Three hot water draws are accomplished each day at 8 a.m., noon, and 4 p.m., as per ASHRAE standard 95-85. The test data were acquired for the time period of July 24-28, 1994. All temperature measurements are made with high-grade type T (CopperKonstantin) thermocouples. It is essential that extremely accurate temperature measurements be made, as the temperature differences are directly proportional to the energy using balances on 294

components. All thermocouples are shielded between the collector outlet and a point on the wall of the solar storage tank. -- ---- -- ---- ---- Shielded Room Ambient TcmpQat= The load-side heat exchanger coil is 36.58 m (120 ft) of 0.0191 m (3/4 in) copper tubing coiled through the entire height of the solar storage tank. The coil is situated near the outer edge of the inside of the tank. The draw flow rate is 1.96 x 104m3/s (3.1 gpm). During a draw potable water from main supply flows to the bottom of the solar storage tank through a dep-tube, then spirals upward through the heat exchanger coil. The water then flows into the bottom of a standard 0.14 m3 (36 gal) auxiliary storage tank. Energy is transferred between the tanks only when there is a hot water draw. 3. EXPERIMENTAL RESULTS Due to space limitations, only two days of the five days of test data will be presented. The two days are July 26 and July 27, 1994. These days were chosen as representative of the entire data set. July 26 was a fairly cloudy day and July 27 was a clear day with the highest solar insolation. As an indirect example of the heat exchanger performance, the solar storage tank temperatures are shown versus time in Figure 2. The top node of the tank is denoted by N=l, while the bottom node of the tank is denoted by N=8. The times when draws are done are denoted on the figures with a D. Leeend ~Tiitcd Pyrrnometa @ Shicl&d, Aspirattd aes - Ambtent Tanpenaut m Hcximml Pymclmeter y widspcal/dinxtim T Tanp=naut Musurcmcnt p Power Mu-t T Pressure Relief Valve hp DifferentialRewureM tasuun=t ~33 BallValve 3 Flow MusuluncnL z chcckvs.lvc Rcsirtivc Hutrz Ehm vial Flow Metu Fig 1. Weather station and system instrumentation electrical conduit, and electrically isolated from the shields to prevent ground loops. Thermocouple arrays have been designed to measure tank temperatures at eight heights, where the spacing between thermocouples in the tank is uniform at one-eighth of the height of the tank. The return flow from the drainback collector enters a custom 0.35 m3 (91gal) unpressurized solar storage tank. The pump circulates the solar storage tank water to the collectors and back to the solar storage tank at a flow rate of 3.9 x low5 m3/s (0.6 gpm). The pump motor is rated at 29.8 W (l/25 hp). Fluid pumping of the system is accomplished using a bang-bang controller, with operation controlled by the temperature difference 26-J& 94 27-Jul--94, I. r, r r 7 a.m. 7 p.m. 7 a.m. Time of Day 7 p.m. Fig. 2 Main solar storage tank temperatures An average stratification of lo- 15 -C is observed in the tank, with greater stratification in the afternoon, due to 7 a.n 295

the solar contribution. The very top node of the tank is cooler than several of the nodes below it. This is due mostly to an air gap which exists at the top of the tank when the collector is being pumped, and in part to the heat loss out the top of the tank. The stratification during a draw becomes more pronounced because the temperature in the bottom of the tank decreases by as much as 15cC while the temperature in the top of the tank decreases by only 3-5 3C. This suggests that the mains supply water gains most of its energy from the bottom of the tank. During the day, between draws, the tank water temperature increases due to the solar contribution. This is especially noticeable in the bottom of the tank. During the night, the bottom of the tank actually warms up due to the conductive heat transfer from the rest of the tank. Figure 3 shows the time histories of the temperature rise across the heat exchanger. The water mains supply temperature remains fairly constant at 16 C. As seen from Figure 3, initially the energy from the heat exchanger is very high, due to the four hours between draws, which has allowed the fluid in the heat exchanger to come into equilibrium with the tank water temperature. The residence time of water in the coil is 53 seconds at a draw flow rate of 1.96 x 10-4 m3/s (3.1 gpm). Thus, it is after about 1 minute that the heat exchange should begin to be well renresented 1 bv, traditional correlations. copper tubing, and the last is the outside convective heat transfer coefficient due to the natural convection flow around the coil. The inside convective coefficient is determined using the Dittus and Boelter equation [Welty, 19761 for the fluid being heated as the Reynold s number is 33,961 (the flow is turbulent), yielding a Nusselt number of 140. (1) h.d Nui = ~ = 0.023Rez8Pr0.4 The corresponding convective coefficient is 4,890 W/m C (86 1 Btu/hrft F). The conductance through the copper tubing is negligible. The outside convective coefficient is predicted using four methods. The representative temperature difference used for each method is 12 C. This is based on the 10-l 5 C difference between the tank temperature and the supply temperature during a draw. The results of these methods are summarized in Table 1. Method (a) uses a correlation for a vertical cylinder, b Given as equation (2) from Kakac [ 19871, which is valid for all Ran. The Ra number was calculated using the large coil diameter (0.66 m, 26 ) as a characteristic length. This correlation actually was developed for an isothermal solid wall in an infinite fluid, with no influence from the surrounding wall. Method (b) assumes that the coil area is a vertical flat plate. This could be inferred since D/L>35/GrD1 4 [Kakac, 19871, with less than 5% error. The correlation, given as equation (3), is based on the height of the tank, L (1.4 m, 55 ). 0.387R? [ 1 + (0.492/Pr) 9 16] 8 27 2 : : : : : : : 0 2 3 5 6 Tim: (minutes) Fig. 3 Heat exchanger inlet and outlet versus time 4. ANALYSIS 4.1 Overall Heat Transfer Coefficient 7 8 Method (c) is for flow over a horizontal cylinder. The Ra number is based on the diameter of the tubing (0.019 m, 0.75 ). The McAdams correlation [Welty, et. al., 19761, which holds for 104<Ra,<109, is: (4) Nuo = 0.53 (GrDPr) 1 4 The overall heat transfer resistance of the heat exchanger is comprised of three terms. The first is the inside convective coefficient due to forced flow through the coil (draw flow), the second is the conductance through the Method (d) uses the correlation equations (5) and (6), from Farrington and Bingham [ 19871. Note that they recommend using the LMTD as the driving potential. 296

Further, they recommend C=0.9 and m=l/4 (for laminar flow). (5) Nuo = CR; (6) LMTD = Finally, the test results were reduced as shown in equation (7). In all cases, the area, A, is equal to 1.86 m2 (20 ft ).. (7) hmeas = Qdrw A ( Ttnk - Tcoil) = (Ilicp) drw (THX, out - THX, in) The results of the calculations are provided in Table 1. Note that method (c) agrees with the measured value to within 20%. The coils within the tank are stacked on top of one another with almost no gap in between each successive coil, which seem to enhance the heat transfer over a single horizontal cylinder. This is attributed to the vortex shedding off of each coil. Therefore, the flow is turbulent over each coil, which increases the heat transfer. 4.2 Effectiveness The heat exchanger effectiveness was calculated using equation (8). (8) E = + = mdrwcp tthx out - THX in) mxx mdrwcp ( TTnk Max - TH);. in) Figure 4 presents the calculated effectiveness for over two days of draw data. The average calculated effectiveness is 0.78 for all data. The frost minute of data is the purging of the warmed coil water. The energy contained in the hump, over and above the 0.78 average effectiveness, is only 3% of the total draw energy. The spread in the curves is due to the dependence of the outside convective heat transfer coefficient on the temperature difference. Notice in Figure 2 that the tank temperature had not risen significantly between the 8 a.m. draw and the noon draw on July 26, 1994. This was a cloudy day and the pump had not operated much; hence the temperature difference is lower, as is the effectiveness. Also, it was found that the effectiveness is not affected by whether or not the pump is on or off during the actual draw. 1 TABLE 1. HEAT TRANSFER PROPERTIES Method Eqn Ra (a) t2) 6.5 x 10 UA (w/c) Q (w) 33 1 450 6./50 --N* July 27,4pm @ ) (3) 1.6 x 10 719 905 3;,575 (4 (4) 6.8 x lo9 834 1,321 19,815 00 (5) 4 x 16 791 1,266 12,660 0.7 meas. - 5x106 1,040 1,600 24,000 Also, note the poor agreement (47%) from method (d). This is perhaps due to the short duration of our draws (7 minutes) relative to the long duration of Farrington and Bingham s tests (3 to 4 hours). Only a small fraction of energy is extracted from the tank over 7 minutes, a shallow draw, while in contrast the tank is nearly completely purged of energy over 4 hours, a deep draw. This makes the LMTD a poor predictor of performance for situations where the tank temperature changes little. A load-side heat exchanger of this design appears to be relatively ineffective at extracting energy from the tank over shallow draw profiles. Therefore, it probably leads to substantially sub-optimal performance of the system. 0.6 0 2 Time (kinutes) Fig. 4 Heat exchanger effectiveness 6 8 In trying to correlate heat exchanger effectiveness with our experimental data, it is noted that equation (9) for a counterflow heat exchanger results in a calculated effectiveness of 0.74. The equation is from Kays and London [ 19641. (9) E = NTU -9 UA N,u = c l+ntu min 297

5. SIMULATION RESULTS It is also important to assess the performance of the solar system vis a vis the SRCC efforts, which seek to rate system performance using TRNSYS [Klein et al., 19941 simulations [Burch et al., 19931. One of the overall goals is to match the model to experimental data by adjusting the model parameters to represent more accurately the physical properties of the system. A TRNSYS module for modeling a load-side heat exchanger did not exist in version 13.1 at the time of this work, so the tank models were tricked into simulating one by including a heat exchanger effectiveness parameter. The measured average heat exchanger effectiveness of 0.78 was used to adjust the load flow out of the solar storage tank. The replacement fluid into the solar storage tank, since the flow into the main solar storage tank from the hot source (collectors) is not equal to the solar storage tank load flow, is at mains supply temperature. The flow from the hot source (the solar storage tank) into the auxiliary storage tank is zero. The temperature entering the auxiliary storage tank as replacement fluid is also adjusted by the effectiveness. The draw flow off of the auxiliary tank is the experimental value. The results are shown in Table 2, indicating agreement. TABLE 2. MEASURED excellent AND TRNSYS RESULTS Quantity Measuredl TRNSYS %ErrOr U&-U 186 184. %i,w (w) 114 115-0.9 achieved, indicating that for shallow energy draws, a constant effectiveness model yields excellent agreement with observations. 7. REFERENCES (1) ASHRAE, Standard 95-85: Method of Testing to Determine the Thermal Performance of Solar Domestic Hot Water Systems, ASHRAE, Atlanta, GA, 1985 (2) Farrington, R. B., and Bingham, C. E., Testing and Analysis of Load-Side Immersed Heat Exchangers for Solar Domestic Hot Water Systems, Prepared for the U.S. Department of Energy, Contract No. DE-AC02-83CH 10093, Solar Energy Research Institute, Golden, co, 1987 (3) Kakac, Sadik, et. al., Handbook of Single-Phase Convective Heat Transfer, Ch. 12 & 13, John Wiley and Sons, New York, NY, 1987 (4) Kays, W. M., and London, A. L., Compact Heat Exchangers, Second Edition, McGraw-Hill Book Co., New York, NY, 1964 (5) Klein et al., TRNSYS - A Transient System Simulation Tool, Ver. 14.1, Solar Energy Laboratory, University of Wisconsin, Madison, WI, 1994 (6) SRCC, January, Standard OG-300: Directory of Solar Water Heating Systems Meeting Minimum Operating and Performance Requirements, Publication of the Solar Rating and Certification Corporation, Washington, D.C., 1993 (7) Welty, J. R., et. al., Fundamentals of Momentum, Heat and Mass Transfer, Second Edition, John Wiley & Sons, Inc., New York, NY, 1976 6. CONCLUSIONS The external flow around the coil is laminar, natural convection, while the inside is turbulent, forced convection. The inside heat transfer coefficient contributes little to the overall thermal resistance, while the outside resistance is dominant. The best agreement for the outside heat transfer coefficientis obtained using the correlation for free convection from a horizontal cylinder, with a 20% enhancement most probably due to an increase in the heat transport attributed to turbulence generated from flow over each coil in the heat exchanger. An average effectiveness of 78% was calculated from experimental data. When used in a TRNSYS model, agreement to within 1% of energy delivered was 298