DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

Similar documents
DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

RPI Industries, Inc.

RPI Industries, Inc.

RPI Industries, Inc.

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

High Profile Evaporator

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

BLOCK ICE MAKERS BY DELTA ICE, AIR AND HEAT INC.

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

T-Series Air Conditioner T20 Model

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL nvent Rev. G P/N

Condensing Unit Installation and Operating Instructions

SPECTRACOOL Air Conditioner

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Installation, Operation, and Maintenance Information

INSTRUCTIONS! DO NOT DISCARD!

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

POLAR TEMP XPORTABLE ICE MERCHANDISER SETUP MANUAL

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Condensing Unit Installation and Operating Instructions

Installation & Maintenance Instructions

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

Liebert InteleCool Warranty Inspection Check Sheet

T-Series Air Conditioner T15 Model

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL. Rev. B 2016 Pentair Equipment Protection P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

PROAIR Air Conditioner

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

PROAIR Air Conditioner

MACH N-407 Heat Pump Air-Cooled Chiller

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

A/C-HEATER SYSTEM - MANUAL

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

KTL Two-Way Low Profile Evaporators

Indirect gas-fired air heater

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RPI Industries, Inc.

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Installation instructions for Plenum-mounted add-on electric heaters

RSIF Power Venter. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

REFRIGERATION AND AIR CONDITIONING RÉFRIGÉRATION ET CLIMATISATION POST-SECONDARY NIVEAU POSTSECONDAIRE

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

M Series Fan Filter Units

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Product Information and Technical Guide

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

MAC N-407 Air-Cooled Chiller

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

T-Series Air Conditioner T53 Model

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Equipment Protection P/N

T-Series Air Conditioner

Horizontal Bottle Cooler Installation and Operation Manual

Rittling Fanvector. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option

XC Portable Air Conditioning

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

CPL Series Pedestal Convection Heater

PDF Created with deskpdf PDF Writer - Trial ::

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Transcription:

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee 37091 Phone (931) 359-6211 1-800-251-8990 www.doleref.com ECONO-MAN 1 ECONO-CEL OPERATION & MAINTENANCE MANUAL June 2002

Econo-Cel Table of Contents Introduction 3 Method of Operation 3 Installation Instructions 5 Operating and Maintenance 10 Parts List 12 Warranty 13 List of Illustrations Figure 1 - Refrigeration Diagram 6 Figure 2-115V Econo-Cel Control Unit Wiring Diagram 8 Figure 3-230V Econo-Cel Control Unit Wiring Diagram 9 2

Introduction The purpose of this manual is to describe the Dole Econo-Cel Eutectic Blower Unit and to present information relative to its maintenance. An attempt has been made to offer as much practical assistance as might be required to troubleshoot and resolve problems that may arise. Dole Econo-Cel Eutectic Blower Units Method Of Operation The Dole Econo-Cel Holdover Plates is designed to maintain temperatures in refrigerated truck bodies. It consists essentially of a series of Dole vacuum holdover plates mounted in a rigid frame and protected by a galvanized housing with an aluminum front cover. Fans mounted at the top of the unit draw air in at the bottom of the unit, up and over the holdover plate surfaces, and out the top front fan outlets. Econo-Cels are available for either ammonia or freon refrigerants. Refrigerant R- 717 models have 1/2 F.P.T. inlet and outlet refrigerant connections. Direct expansion refrigerant models have 3/8 inlet and 7/8 outlet copper tube extensions. Direct expansion refrigerant models come equipped with thermostatic expansion valve(s). Component Parts (built in) Motor-Designed for DC operation with nominal ratings of 6.0 amps at 12 volt; DC; totally enclosed with replaceable brushes. Fans-On all models, a 10 diameter fan rotates at 2100 RPM and delivers 1000 CFM; the fan consists of four aluminum blades riveted to a cadmium plated spider & hub. Control Unit-Consists of a compact aluminum plate housing mounted in the upper section of the Econo-Cel and contains the following parts: Alternating Current Relay-Isolates fan from truck battery voltage when the unit is connected to a 115 or 230 VAC power source. Transformer-Transforms the primary voltage from 230 volt single phase AC to a secondary voltage of 16 volts AC. Rectifier-Converts 16 volts AC to DC voltage required by fan motor. 3

Direct Current Relay-Energizes or de-energizes fan motor in response to manual toggle switch, door switches, dash switch or thermostat. Circuit Breaker- (25 Amp) protects motor circuit from overload. Terminal Block-provides positive and convenient method for making required electrical connections as indicated on Control Unit Wiring Diagram. Component Parts-supplied separately Dash Switch-When mounted on dash panel, allows driver to disconnect the fan motor in the event the truck will be out of service for an extended period of time, unless the switch is turned off it could discharge the truck battery as a result of the fan continuing to operate. Pilot Light-when mounted on dash panel, indicates whether dash switch is on (lit) or off (unlit). 4

Installation Instructions Uncrate Econo-Cel and examine for damage in transit. If such has occurred, notify carrier immediately. Consignee must make claims. Remove package containing 1 dash switch and 1 pilot light, checking to make sure there has been no loss or damage in shipment. Check Voltage shown on nameplate of Econo-Cel against both that of the truck and available alternating current for nighttime use. Provision For Drain-Drill hole in floor of body for drain tube. Inspections Panels located on the front of the Econo-Cel unit, near the top, are readily removed by loosening the screws holding them in place. Upon removal, the expansion valve(s), fan motor and control unit are accessible. Truck Body Temperature Control- It is recommended, if truck body temperature is critical, that a thermostat control the fan. In attempting to control the body temperature by condensing unit pressurestat only, there is a possibility of two low a temperature under some circumstances. Conversely, if the pressurestat setting is high enough to prevent this from happening, it may result in the unit cutting off before the eutectic solution in the plates is completely frozen. Control of the fan with a thermostat will keep the temperature above the danger point, while allowing the condensing unit to continue to store up holdover in the plates of the CHO Truk-Cel. The low-pressure control should be used as a safety switch, with a setting 25 degrees colder than the plate temperature. A cut in pressure of 10 psi or higher should be sufficient. For example, an 18 degree (F) plate using R22, the low pressure control should be set at 19 psig and the cut in should be 30 psig. Should short cycling occur after initial cut out, the low pressure cut in should be raised to provide an acceptable cycle time. 5

Refrigeration Instructions Condensing Unit Self Contained Liquid and suction lines of copper tubing, usually 3/8 and 7/8 respectively, are run between the outlet on the receiver of the condensing unit to the inlet of the Econo-Cel, and from the outlet of the Econo-Cel to the suction shut-off valve on the compressor. Tubing lines should be securely fastened to the body by clamps to prevent vibration and protected against the possibility of damage by running them through rigid conduit at points where such damage could occur. Flared or soft soldered joints are not recommended. Accepted procedures are to be followed with respect to evacuating, purging, leak testing and charging the system. Figure 1 Refrigeration Diagram 6

Electrical Instructions Electrical Hook Up-Careful study of the Control Unit Wiring Diagram (Figure 2A or 2B) is suggested. Most of the connections shown are already made in the control unit, with those left to be made in the field indicated in the diagram by the notation Connections to be Made By The Customer. In those cases where no one is responsible for the plugging in of the system, the optional wiring diagram may be used. This method will prevent the battery from becoming drained should the truck be parked (and not plugged into the A.C. power) for any prolonged period of time causing the system to revert to D.C. operation. Control Circuit consisting of the wiring of the body, with the door switch, thermostat, if used, and dash switch hooked in series. The purpose of this control circuit is to actuate the D.C. relay. The amperage draw is small (about 0.1 amps on 12V). The pilot light is connected between the appropriate pole of the dash switch and ground, and lights when the dash switch is closed. Power Line Circuit bringing single phase 115 or 230 volt alternating current to the Econo-Cel. The power supply serving the condensing unit may be used, but the line to the Econo-Cel must be taken off ahead of the compressor starter, as current to the Econo-Cel would be cut off when the compressor stops. Battery Circuit bringing 12v direct current to the Econo-Cel. As specified in the diagram, one lead must come directly from the hot side of the battery. It must NOT be connected through the cold side of the ignition switch or voltage regulator since the D.C. relay must be energized for the fan motor to operate. Holes are located in the top left side panel of the Econo-Cel housing through which the electrical lines are passed to the conversion unit. 7

Figure 2A 8

Figure 2B 9

Operating and Maintenance Instructions The Dole Econo-Cel will give many years of satisfactory service with a minimum amount of maintenance. The following suggestions will add to the performance and life of your Econo-Cel. A. The product load should be arranged so that the air supply is not restricted at either the top or bottom of the Econo-Cel. Stacking product against the front of the unit should be also be avoided to allow free air flow. B. Periodically, at the end of a run, remove one of the inspection panels and check for frost build up on the plates. If frost buildup is greater than 1/4 it should be removed. This is accomplished by (a) continuing to operate the fan but leaving the compressor inoperative or (b) washing down plates with warm water (150 degree maximum) for rapid defrost. C. Lubricate motor bearings with 3 drops of SAE-20 oil in front and rear oil tubes every 3 months. Do not over lubricate. D. Check length of motor brushes every 6 months-if under 3/16 replace with new brushes (available from Dole); otherwise re-insert old brushes in same relationship to commutator as before. E. For longer motor life, dress commutator after two sets of brushes have been used. F. Clean fan blade periodically. G. Keep control switches clean and free from excessive moisture. H. Assure that wiring is protected adequately at wear points and does not run moisture traps. I. If the Econo-Cel fan motor should fail to operate, the following steps should be taken in an effort to locate the difficulty. 1. Make sure the control, AC power line, and DC battery circuits are connected to terminal block as shown in Figure 2A or 2B. With respect to DC circuit, make sure that terminal 5 is connected to the hot side of the battery (not through the voltage regulator or ignition switch) and terminal 6 is connected to ground. 2. Make sure that AC and DC voltages being supplied to Econo-Cel correspond to voltages shown on the Econo-Cel nameplate. 10

3. Make sure that all switches in the control circuit are in the on position. 4. Check for free rotation of motor shaft by manually turning fan blade. 5. Check that circuit breaker has not been tripped. 6. Check AC relay by connecting and disconnecting Econo-Cel AC line to outside source of AC power. Field repair of AC and DC relays is not recommended. 7. With Econo-Cel AC line not connected to outside source of AC power: a. Check that 12v DC is being supplied to control unit by connecting voltmeter across terminals 5 and 6. If optional wiring circuit is used, be sure ignition switch is in the on position. b. Check continuity of control circuit by connecting the voltmeter across terminals 1 and 6. c. Check DC operation of motors by connecting terminal 8 to terminal 5 with a jumper wire; non-operation indicates a defective motor or motors. d. In the previous step, if the motor runs only when the jumper wire is used, defective internal wiring or a defective relay is indicated. To check R1 relay, connect terminal 5 to terminal 2 with a jumper wire. If motor does not run, a faulty R1 relay is indicated. 8. With Econo-Cel AC line connected to outside source of AC power: a. Check that AC current (115v and 230v) is being supplied to conversion unit by connecting voltmeter across terminals 3 and 4. b. Check transformer output (approx. 16v AC) to rectifier by connecting voltmeter across rectifier terminals AC. c. Check output of rectifier by connecting voltmeter across rectifier terminals + & - (wires 32 and 32). If the above procedures do not reveal the source of difficulty, the control unit should be returned to Dole for complete checkout and repair. 11

Replacement Parts For Econo-Cel Part No. Description 09-303----------------------------------------------------------------12v DC Fan Motor 16-007----------------------------------------------------------------10 Diameter Fan Blade 7462-CS10-2-------------------------------------------------------Complete Control Kit (230v/12v DC) 7462-CS10-1-------------------------------------------------------Complete Control Kit (115v) 10-531----------------------------------------------------------------115v AC Relay 10-521----------------------------------------------------------------220v AC Relay 10-423----------------------------------------------------------------Transformer MA7727-B200------------------------------------------------------Diode Assembly 10-522----------------------------------------------------------------12v DC Relay 11-709----------------------------------------------------------------Circuit Breaker 09-304----------------------------------------------------------------Brush & Spring Assembly 10-206----------------------------------------------------------------Toggle Switch 10-207----------------------------------------------------------------Toggle Switch Plate 11-107----------------------------------------------------------------Terminal Block 11-412----------------------------------------------------------------Pilot Light 12v (Green) 16-108----------------------------------------------------------------10 Fan Guard 28-427----------------------------------------------------------------Expansion Valve (R22) 28-423----------------------------------------------------------------Expansion Valve (R404A) 12

Warranty Econo-Cel Eutectic Blower Unit The Company warrants this Dole Econo-Cel Unit to be well made, of good material and free from defects. It is guaranteed against any defect in material or workmanship for the following period of time, providing, if claimed defective, the Econo-Cel or any part thereof is returned to the Company, transportation charges prepaid. ECO Models FAN MOTORS & VOLTAGE CONVERSION UNIT 90 DAYS BALANCE OF UNIT 1 YEAR PLATES- 5 YEARS. If Dole Plates should prove defective after TWO years and prior to the lapse of THREE years, the Company will replace said Dole Truck Plate for 45% of prices in effect at time of exchange, and if said Dole Plate shall become defective at the end of THREE years and prior to the lapse of FOUR years, the Company will replace said Dole Plate for 60% of prices in effect at time of exchange, and if said Dole Plate shall become defective at the end of FOUR years and prior to the lapse of FIVE years, the Company will replace said Dole Plate for 75% of prices in effect at time of exchange. The Company shall not be liable for any damage of any nature caused by defects in workmanship or material or for any other reason, but is liability shall be limited to the value of the Dole Econo-Cel Unit guaranteed, and correction of any defects in workmanship or material shall constitute a fulfillment of its guarantee. The Company s liability in all events shall be limited to replacing or repairing the defective part, whichever it seems advisable. 13