S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

East Central College

SC Installation, Operation & Application Guide

SECTION LOW VOLTAGE LIGHTING CONTROLS

600 Watt Dimmer Install Guide

INSTALLATION AND OPERATION MANUAL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

LMA LINE MONITOR ALERT USER S MANUAL

SC Installation, Operation & Application Guide

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Thermostats. Digital Programmable. GEAppliances.com

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

! "! # Please read these installation and operating instructions completely and carefully before starting.

Mini Product Guide.

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

T-32-TS Touchscreen Thermostat. Installation Manual

Installation Instructions

Digital Programmable

QD-ENG-68 Controller for Thermoelectric Thermal Management

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Mark 25 Ultrapure Water Conductivity Analyzer

Programmable Thermostat

IN2 Lighting Control Devices

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

OPERATING & MAINTENANCE MANUAL HORIZONTAL WATER SOURCE HEAT PUMP. World class comfort.

Owner s Manual. Digital Thermostat

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Integrated Classroom Control System. Installation and Operation Manual

BIRKET Specialty Lighting LED BRIK User s Guide

Model #: RC3 Model #: RC3D Model #: RC3DE SAFETY INSTRUCTIONS

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

SC Installation, Operation & Application Guide

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Emery County Senior Center Green River 06/07

SECTION LIGHTING CONTROLS

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

SC Installation, Operation & Application Guide

A. This Section includes the following lighting control devices:

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

CAUTION. Installation Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Installation Instructions

INSTALLATION INSTRUCTIONS

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

INSTALLATION AND INSTRUCTION MANUAL

Product Specifications Dialog Room Controller* (*patent pending)

Analog Room Pressure Monitor RPC Series

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

ACONT600AF11MA/ACONT602AF22MA Programmable Comfort Control

Static Pressure Control

IntelliLED TM. Daylight Harvesting Sensor (DLH): User Guide

Installation, Operation & Service Manual

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Remote Relay Module (RRM)

Model 3300 Technical Support and Installation Manual

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Honeywell ENERGY SAVINGS KIT

9450 Duolink Exit Alarm Receiver Installation Guide

CO2 & Oxygen Monitor Operating Instructions Model: RAD

FLCH4R Garage and Utility Electric Heater

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

LED IMPORTANT SAFETY INSTRUCTIONS

Ceiling-Mounted Motion Detector. 752/CD, 752/CP, 752/CU and 752/Cx180. Installation Instructions

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

T8600D Chronotherm IV Deluxe Programmable Thermostats

LED IMPORTANT SAFETY INSTRUCTIONS

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

SAT-3 Room Temperature Controller

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

SECTION ELECTRICAL SYSTEMS COMMISSIONING

380 SERIES REMOTE SIREN ETSA380R

Connectivity Control Confidence

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

IMPORTANT SAFETY INFORMATION:

MaxLite LED Vapor Tight Linear Fixture

ELECTRONIC COMMUNICATING THERMOSTAT

Owners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W

SC Installation, Operation & Application Guide

Alarm Tone Generator Model AG17

Transcription:

Overview The SIMPLY5 Sensor Connector is used to provide an input for low voltage occupancy sensors and photocells. Use the S5SC with SIMPLY5-compatible lighting fixtures and control devices for fully integrated occupancy and daylight-based lighting control. SIMPLY5 components are plug-and-play devices. They feature automatic detection and configuration for proper operation with other connected SIMPLY5 control devices and lighting fixtures. S5SC Sensor Connectors may be connected at any point in the zone they control. When an occupancy sensor is connected, it will automatically control all zones in the room (all lighting fixtures connected to the SIMPLY 5 Signal Network). When a photocell is connected, it will only control the zone to which it is connected (the local S5JB to which it is connected). Operation The S5SC contains one occupancy sensor input and one photocell input. Occupancy Sensor Input: The S5SC s occupancy sensor input automatically configures to control all lighting fixtures connected in the room, regardless of the number, or location, of all intelligent junction boxes (S5JB) in the space. The S5SC is compatible with the full line of Lithonia Litronic low voltage occupancy sensors. The S5SC s default occupancy sensor function is for manual on / automatic off, but may be configured via the optional S5LEM interface for automatic on / automatic off or automatic on / automatic minimum operation. The S5SC will issue a warning blink 5 minutes prior to turning off the lights. A S5W wall station may be used for manual control and quiet time functionality allowing 1 hour of override to prevent the occupancy sensor from turning off the lights during periods of little movement. To enter Quiet Time mode, press and hold the on/off paddle switch on the S5SW for 3 seconds. The green bargraph LED to the left of the paddle will blink when Quiet Time mode has begun. Photocell Input: The S5SC s photocell input automatically calibrates for daylight-responsive control of the lighting fixtures in the zone to which it is connected. The photocell input only controls the lighting fixtures local to the intelligent junction box (S5JB) zone to which it is connected. 15 WHIP STANDARD FOR S5SC 120 AND S5SC 277 Figure 1 - S5SC 3/08 Page 1

Before You Start 1. Always disconnect all power. 2. Install in accordance with the National Electrical Code and any other codes which may apply. 3. Use only as intended and at the listed voltage. 4. All installation and service must be performed by qualified personnel or service technicians. 5. All installation and wiring information contained herein is based on industry-accepted standards and practices. This information is not meant to conflict with or overrule any applicable codes or ordinances. 6. USE EXTREME CAUTION WHEN PERFORMING MAINTENANCE ON THIS EQUIPMENT. Failure to follow any or all warnings and proper safety procedures can cause severe injury or death, and/or damage to the equipment. Mechanical and Electrical Specifications 1. Ambient Conditions: Maximum Ambient Temperature: 104 F/40 C Minimum Ambient Temperature: 32 F/0 C Relative Humidity: 10-90% Non condensing. 2. Power Input: 10-22V, 1.7W max, powered by Simply 5 signal buss. 3. Low voltage power supply: 24VDC, 70 ma maximum, fully regulated, short circuit protected, Class 2 output. 4. Occupancy Sensor Input: Class 2, 0-24VDC; Compatible with all Synergy Litronic brand low voltage occupancy sensors. 5. Photocell Input: Class 2, 0-10VDC; Compatible with DEQ APS series photocell. 6. NEMA 1 enclosure: Mount S5SC using the mounting holes in the rear of the enclosure. 7. A maximum of 3 S5SC(s) can be operated by one intelligent Junction Box (S5JB). Maximum Number of SIMPLY5 Devices: Each S5JB Signal Network can support a maximum of 100 SIMPLY5 devices - S5 Fixtures, S5W wall stations, S5SC sensor connectors or other S5JB(s). When adding occupancy sensors, the total number of possible devices drops based on the number of sensors being added. Refer to the tables below for more information: # of S5 Ballasts, # of LMT, LMTO, LUSO S5W Wall Stations, Occupancy Sensors S5SC Sensor Connectors (32ma each) 100 0 84 1 68 2 52 3 36 4 # of S5 Ballasts, # of LIRO, LIRC S5W Wall Stations, Occupancy Sensors S5SC Sensor Connectors (20ma each) 100 0 90 1 80 2 70 3 60 4 50 5 40 6 Page 2 3/08

Installation HARDWARE Mount Device Mount the S5SC above the ceiling near the photocell or occupancy sensor location, using the mounting holes in the back of the S5SC enclosure. ELECTRICAL Connect Devices The S5SC Sensor Connector is furnished with a Reloc Control Tee for plug and play connection at any point on a SIMPLY5 control zone. The S5SC may also be ordered without the Reloc connector by ordering the HW hardwire option. S5SC Connect the S5SC Reloc Control Tee at the point on the SIMPLY5 zone where control is desired. Connect the occupancy sensor and/or photocell to the S5SC by terminating the conductors from the sensor in the poke-home connector inside the S5SC enclosure. (See Figure 2 For Details) S5SC HW: Select the point on the SIMPLY5 zone where control is desired. Connect the SIMPLY5 signal network conductors to the 2 violet wires inside the S5SC enclosure (they are not polarity sensitive). Connect the occupancy sensor or photocell to the S5SC by terminating the conductors from the sensor in the poke-home connector inside the S5SC enclosure. (See Figure 2 For Details) S5SC CIRCUIT BOARD POKE HOME CONNECTOR RED (+24 VDC) YELLOW (PHOTOCELL) BLUE (OCCUPANCY ) BLACK (DC COMMON) RED YELLOW BLACK PHOTOCELL RED BLACK BLUE OCCUPANCY Figure 2 - S5SC Wiring Terminations 3/08 Page 3

The S5SC s photocell input automatically calibrates for daylight-responsive control of the lighting fixtures. Manual calibration is typically NOT required for proper photocell operation. However, for situations where greater control over daylight harvesting operation is desired, an optional Scaling Factor Setup procedure is available. As this Scale Factor setting is lowered, the natural light in the space will have less effect on the artificial light level. As the Scale Factor setting is raised, the natural light in the space will have more effect on the artificial light level. Follow the steps below to set up the Scaling Factor: Calibration 1. Grasp the bottom of the large paddle on the S5SW, and pull out and up gently until you hear a click and the bargraph and amber locator LEDs go off. 2. Press in and hold the paddle switch until the amber locator LED begins flashing once per second, then release it. 3. Press & release the paddle switch once, the amber indicator LED will begin to flash twice per second. 4. Press & release the paddle switch once more, the amber indicator LED will turn steady on. 5. Within the next 10 seconds, you must press and hold the paddle switch until the bargraph LED begins to flash. This should be about 3 seconds. 6. Release the paddle switch after the bargraph LED begins to flash. The lights will flash 3 times indicating Scale Factor Setup Mode is active. The bargraph will indicate the current Scale Value. 7. Use the Raise/Lower button to set the Scale Factor from 1 to 7. 8. Press & release the paddle switch once more to exit Scale Factor Setup Mode. The lights will flash 3 times indicating the system has exited Scale Factor Setup Mode. Note: During this calibration period, you should not try to operate the lights. Additionally, the user has the option to force the photocell into calibration mode. Follow the steps below to force calibration: 1. Grasp the bottom of the large paddle on the S5SW, and pull out and up gently until you hear a click and the bargraph and amber locator LEDs go off. 2. Press in and hold the paddle switch until the amber locator LED begins flashing once per second, then release it. 3. Press & release the paddle switch once, the amber indicator LED will begin to flash twice per second. 4. Press & release the paddle switch once more, the amber indicator LED will turn steady on. 5. Within the next 10 seconds, you must press and hold the paddle switch until the bargraph LED begins to flash. This should be about 3 seconds. 6. Release the paddle switch after the bargraph LED begins to flash. The lights will flash 3 times indicating Scale Factor Setup Mode is active. The bargraph will indicate the current Scale Value. 7. Press and hold the paddle switch until the bargraph LED begins to flash, which should last about 3 seconds. The lights will flash once to indicate calibration mode is active, then the lights will go to full for approximately 30 seconds. While at full, the bargraph LED will blink from bottom to top. After this time interval ends, the lights will go off for 5 seconds. While off, the bottom bargraph LED will blink from top to bottom. The lights will blink once more to indicate the end of calibration mode, and then transition back into Scale Factor Setup Mode. 8. Press & release the paddle switch once more to exit Scale Factor Setup Mode. The lights will flash 3 times indicating the system has exited Scale Factor Setup Mode. Note: During this calibration period, you should not try to operate the lights. Page 4 3/08

CONNECT OCCUPANCY S AND PHOTOCELLS AT ANY POINT ON THE ZONE THEY CONTROL BY USING AN S5SC CONNECTOR SYNERGY LITRONIC OCCUPANCY S5SC CONNECTOR TO ADDITIONAL FIXTURES ON THIS ZONE CLASS 2 HARDWIRES INTO S5SC DEQ APS S5 COMPATIBLE FIXTURES S5JB S5SSC S5SC CONNECTOR S5SSC ADD S5W WALLSTATIONS AT ANY POINT ON THE ZONE S5W Figure 3 - SIMPLY5 System Connections Adding S5SC Sensor Connector (Typical) 3/08 Page 5

1. The sensors connected to S5SC appear to have no control: The S5SC circuit board contains a status LED which will blink approximately once a second while power is applied. If the sensors connected to S5SC appear to have no effect on the controlled lighting fixtures, remove the cover on the S5SC and verify that the status LED is blinking. If the LED is not blinking, the S5SC is damaged, is not connected to the SIMPLY5 data signal network, or the SIMPLY5 data signal network is not operating correctly. Troubleshooting Contact SIMPLY5 Technical Service at 888-888-0002. SIMPLY5 Technical Service is available Mon - Fri, from 8:00 a.m. to 5:00 p.m. EST for phone consultation. Visit SIMPLY5 on the internet at http://www.simply5.net for additional information on products, technical data and installation instructions. Warranty SIMPLY5 warrants all equipment to be free from defect in manufacturing, under normal and proper storage, installation, and use. For SIMPLY5 products containing standard Reloc connectors, the warranty is 3 years. For SIMPLY5 products using the hardwire option, the warranty is 1 year. Our guarantee liability extends only to the repair or replacement of the defective part and no labor charges for correction of the defect by repair or replacement will be honored by SIMPLY5 unless prior written authority has been granted by our Customer Service Department. Page 6 3/08