Bristol Babcock Oil Content Monitor "oil in water"

Similar documents
Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Model D12-IR. Digital Gas Transmitter...

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

CO warning instruments and gas spillage detectors

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Zareba Sensepoint Pro

Turbimax CUE21 / CUE22

Technical Information OUSTF10

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 5720 IR Toxic Gas Detection

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

GasAlertMicroClip X3 Specifications

IRceL CH4 Methane (CH 4

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

SIMRAD GD10 IR GAS DETECTOR

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Inductive Conductivity

PUV, PIR and PFO Series BROCHURE

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

PRODUCT CONFORMITY CERTIFICATE

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

GAS ANALYSIS / DETECTION Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

10yr O2NE & Safe-Ox. User Manual

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

UV Flame Supervision System

Mobrey ultrasonic Liquid level detection systems

Technical Information OUSAF21

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

SIMRAD GD10PE IR GAS DETECTOR

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Turbimax CUE21 / CUE22

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Datalogging as standard

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Free Chlorine Measuring System

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

PEPPERL+FUCHS GmbH

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Dräger Polytron 8720 IR Detection of carbon dioxide

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

CLARITY II TURBIDIMETER

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

Dräger Polytron 7000 Fixed gas detector

Sieger Apex. Flexibility that meets your requirements

Open-area Smoke Imaging Detector. Engineering Specification

Class 1 laser beam sensor safe for your eyes

Phoenix Flameproof. Pan & Tilt heads and Camera Housings for potentially explosive environments.

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Hazardous Area Zirconia Oxygen Systems

FCHM Hydromatic Pump Control Module

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

intrinsically safe detector for hydrocarbon gases

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Dust Concentration Meter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

High Pressure Conductivity Monitor

Laser Collimated Beam Sensor

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

II 1G EEx ia IIC T4 T a = -20ºC to +60ºC

OLC(T) 100 FIXED GAS DETECTOR

Technical Information OUSAF22

Technical Information OUSTF10

Transcription:

NORTHEAST CONTROLS INC. ONLINE www.nciweb.net 123 Pleasant Avenue - Upper Saddle River - New Jersey 07458 USA Tel: 201-327-7660 / Fax: 201-327-3242 Bristol Babcock Oil Content Monitor "oil in water" General Description The OPM 2 oil content alarm has been specifically designed for the monitoring of effluent in hazardous areas. At present there is no formal international specification for 'industrial' effluent monitors. For offshore application the OPM 2 is fully compliant with IMO specification A393X and MEPC60(33). The design of the OPM2 is the result of more than 25 years experience in the development of oil content monitors, making use of advanced techniques and very high specification components. The very low level of concentration in parts per million of oil in water is displayed on a back lit LCD digital indicator. Facilities are provided for remote indication, recording, and alarm status. Principle Of Measurement Measurement is based on the principle that oil particles scatter light. The amount of light scattered is proportional to the number of particles present, over a limited range of concentration permitted by IMO/environmental limits. The instrument measures both scattered light and transmitted light, then employs a ration technique enabling the measuring system to self-compensate for variations in the brightness of the light source. Features Compact Continuous Operation Simple Installation Low Maintenance Cost No Warm Up Period Factory Calibration http://www.nciweb.net/opm2.htm (1 of 5) [7/9/1999 2:59:47 PM]

Construction The OPM2 (Option 1) is housed in a die-cast aluminum case providing protection to IP65 requirements, and is certified for use in Zone 1 and Zone 2 areas. The measuring cell is housed in a die-cast aluminum case providing Explosion Proof Protection. A further option is the OPM2 (Option 2) which allows the control unit to be mounted in a safe area. The OPM2 (Option 2) which allows the control unit to be mounted in a safe area. The OPM2 (Option 2) control unit is housed in a deep drawn steel case providing protection to IP55. The monitor and cell can be mounted independently of each other. Interconnection is by intrinsically certified cable. Operating Technique The side stream sample flows through the cylindrical glass cell, through which a low intensity beam of infrared radiation is projected. Two silicon photodetectors are provided to detect the direct path of radiation, and radiation scattered by oil particles. The angles and fields of view of the detectors have been carefully selected to provide high sensitivity to oil and very low sensitivity to solids which may be present in the sample stream. This, coupled with the wavelength of light chosen, ensures minimal sensitivity to water color, and other soluble components, and is inherently self compensating for window fouling, mains voltage variation, and changes in ambient or sample temperatures. Calibration The unit construction allows factory calibration, and interchange of detector assemblies and electronic units can then be carried out on site without further calibration being required. The design utilises all solid state components. Installation Installation of the unit must in accordance with codes of practice for the country of installation. In the United Kingdom the flameproof code of practice is BS5345 parts 1 and 3. Bristol Babcock Ltd recommended that in absence of a local code the United Kingdom code of practice be used. The OPM2 should be installed as close as practical to the sampling point. Access is only required to the front and top of the instrument, and the connection requirements should closely follow the installation http://www.nciweb.net/opm2.htm (2 of 5) [7/9/1999 2:59:47 PM]

diagram. Maintenance Little maintenance is required and is confined to a periodic check of zero against clean water, and occasional cleaning of the glass sample cell. Access to the cell is provided via a screw cap, permitting insertion of a tube cleaning brush. Quality Assurance Bristol Babcock Ltd is approved to BS En9001 (BS5750 Pt 1) In addition, the factory in which this unit is manufactured holds BASEEFA licence MO102. Area Classification Cell Assembly EEx ia IIC T.4 Control Unit OPM2(1) EExd ia IIB T.6 Control Unit (Option) OPM2(2) Safe Area Specification Range Accuracy Alarm Relay 1 Alarm Relay 2 Alarm Contacts Alarm Indication Fault Alarm Fault Indication Concentration Readout Output Signal Electrical Supply: Standard Optional 0-20 ppm ±2 ppm Instant Alarm: Factory Set To 15ppm Delayed Alarm at instant alarm level: Delay time variable 5 to 55 s (factory set at 20 s) Single Pole c/o Rating 2.5A @ 240V 5.0A @ 110V Instant: Red LED Delayed: Red LED Monitor fault sets alarm condition Red LED Back Lit LCD display 4-20 ma 240V ac ± 10% single 50-60 Hz ± 10% 110V ac ± 10% single phase 50-60Hz ± 10% http://www.nciweb.net/opm2.htm (3 of 5) [7/9/1999 2:59:47 PM]

Power Consumption 11 VA Sample Pressure 2 bar to 8 bar Sample Flow 1.0 litres/min Sample Temp +2C to +50C Sample Connections Compression fitting for 10mm outside diameter pipe Ambient Temp -15C to +50C Clean Water Requirement Pressure 2 bar to 8 bar for cleaning and zero check Size Cell: 260mm H x 120mm W x 80mm D Control Unit: OPM2(1) 445mm H x 345mm W x 210mm D Control Unit; OPM2(2) 400mm H x 380mm W x 150mm D Weight Cell: 1Kg Control Unit: OPM2(1) 30Kg Control Unit: OPM2(2) 11Kg Questions? DOWNLOAD THIS PAGE IN PDF FORMAT Let Me Help You Find What You Need! Contact: Northeast Controls, Inc. http://www.nciweb.net/opm2.htm (4 of 5) [7/9/1999 2:59:47 PM]

123 Pleasant Avenue Upper Saddle River, New Jersey 07458 United States Of America Tel: 201-327-7660 Fax: 201-327-3242 www.nciweb.net http://www.nciweb.net/opm2.htm (5 of 5) [7/9/1999 2:59:47 PM]