THE NEW DIMENSION OF AIR CONDITIONING

Similar documents
3 rd Generation of VRV. The professional solution for your professional project

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DAIKIN Air Handling Unit Modular

Integrated VarIable refrigerant flow ahu/pau (r410a)

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

MECHANICAL SERVICES 101. Ian White

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

SIMPLICITY OR FULL MODULARITY?

Flexible & Innovative. Cooling Solutions

ENERGY SAVING SEIBU GIKEN DST

Residential and Light Commercial Ductless Systems Catalog

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

FAN COIL UNITS LASER / LOW BODY / CONCEALED

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

SIMPLICITY FULL MODULARITY?

Safario Cooling Factory LLC

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?

3 years payback time. Millions of reasons to choose the best. Energy Demands? Comfort Problems? Maintenance Concerns?

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Product Line Introduction. Karl Zhang Technical support engineer

Ducted inverter reverse cycle air conditioning

INDUSTRIAL AIR CURTAIN. IndAC 2

Condition Report Date: 24/1/17

Modular Air Cooled Scroll Chillers

Energy-efficient heat source provides comfort in large rooms

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

VRV The total solution. Integrated Climate Control

PMFY-P20VBM-E. City Multi Indoor Product Information. Indoor Unit

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

Infrared Portable Space Heater

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PFS Single stage axial fan The axial fan for modern boiler plants

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

air handling units AT THE LEADING EDGE OF AIR FLOW

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Fan Coil Range HYDRONIC TERMINALS

CASSETTE UNIT. Comfort Circle

Air Conditioners Heating & Cooling

CONTROLLED CHILLED BEAM PUMP MODULE

Innovative air conditioning

Halton Rex for Vario R6O - Variable air volume chilled beam

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Munters DesiCool removes excess heat in server room

42AM. Air heaters PRODUCT SELECTION DATA

NEW RANGE OF WARM AIR CURTAINS

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Infrared Portable Space Heater

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

AIR HANDLING UNITS ver B

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

An efficient solution for more comfortable environments

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

Flexible and efficient: Close Climate Control for IT equipment

CLIMEXEL - M.P.I. MITSUBISHI POWER INVERTER

TopVent Design Handbook

CONTROLLED CHILLED BEAM PUMP MODULE

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

COMPACT VENTILATION UNITS DUPLEX R5

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

DC Inverter Smart VRF Products(R410A)

Condensate water pumps

PUT WASTE HEAT TO USE. with our gas-heated steam humidifier, Condair GS. Humidification and evaporative cooling

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Freezer and cooler islands TectoFreeze IS1. Reliable islands for chilled and frozen food

L CONNECTION NETWORK Commercial Controls

UCS UCS/M UCS/H UCS900

INDUSTRIAL AIR CURTAIN. IndAC 2

EHH SERIES DRAW THROUGH FAN COILS CFM

LOW STATIC HYDRONIC DUCTED UNIT

Water-cooled chillers with High Speed Centrifugal Compressors

Trane Family of Terminal Products

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO CONDITIONER FIXED AIR PORTABLE AIR CONDITIONER AIR COOLER DEHUMIDIFIERS HUMIDIFIERS FAN HEATERS GAS STOVES

COMFORT HYDRONIC TERMINALS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Liebert Mini-Mate2 1 To 8 Tons

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Strong partners in innovative climate technology. Comfort Air Curtains Model CA DK for Daikin VRV-system

Brochure EX

COMMERCIAL LINE. DUPLEX Flexi

MULTI-INVERTER AIR CONDITIONERS

UniTrane U-Line ductable water terminals Optimum efficiency with a sound reduction bonus

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Smoke Master SMIA Compact pressurisation and smoke exhaust system

Katarina Enholm, CEO of Brunberg Oy: WINTER IS THE SEASON OF CHOCOLATE. A new cooling system for the Brunberg sweet factory

Transcription:

THE NEW DIMENSION OF AIR CONDITIONING

Ceiling products controlled by Vari PRO TM NETWORK SERVER CHILLER CEILING PRODUCTS A PLEASANT INDOOR CLIMATE; ENERGY EFFICIENCY AND WITH LOW SOUND LEVEL Chiller Oy is one of the leading system manufacturers of energy solutions in Europe. Our units are always based on our clients specific requirements. Together we find the best solutions for each case. As both unit designer and manufacturer, we offer an extensive range of solutions. The company s head offices and factory are located in Finland, 25 km north of Helsinki. Our premises have a surface area of more than 5,000 m 2. In 2014, Chiller employed over 100 staff, in ten different locations. Our ceiling product group consists of the Vari TM, GRAND Vari TM, STUDIO Vari TM, SMART Vari TM and GIANT Vari TM air conditioning units. The best energy efficiency is ensured by the Vari PRO TM control unit. We have over 20 years of experience in the HEVAC industry. We have delivered more than 3,000 free cooling units with 200 kw capacities. Chiller is the most notable manufacturer of these solutions in the world. Cold water stations, water coolers, heat pumps and precision air conditioning units also constitute our core products. In the service group, we offer an Internet-based monitoring, quickresponse end-to-end service called Service Next TM. 2 Innovative cooling, heating and energy solutions

VARI TM PRO -ROOM CONTROLLER DESIGNED FOR THE USERS Vari PRO TM room controller provides an amazing user experience. It gives direct feedback on energy consumption and service requirements for the user. More detailed data is available to Building Management Systems for energy economy reporting. The new Vari PRO TM controller will change the way of setting desired indoor climate and receiving feedback from the room controller. The Vari PRO TM controller function modes are designed to meet three different user groups: Consumer mode for normal use, Energy saving mode for checking energy consumption and BMS reporting, and Maintenance mode for checking maintenance needs. All three modes have a user-friendly interface. BENEFITS FOR VARI PRO TM USERS: Quick and easy installation (Start-Up wizard/self configuration). Shows power consumption for each unit. Indicates maintenance requirements. Together with Chiller s fan coils it provides minimal energy consumption, low sound level and pleasant climate for users. Read more: varipro.chiller.fi

GRAND VARI TM -MINI AIR HANDLING UNITS A NEW CONCEPT FOR THE AIR-CONDITIONING IN HOTEL ROOMS, OFFICES AS WELL AS RESIDENTAL BUILDINGS Grand Vari Mini AHU can be integrated into the room without any visible technology. It provides comfort and is easy to use. The new EC motor and technical solutions constitute a unique combination on the market. Were you to switch on the GRAND Vari TM fan coil or an LED lamp, you would not notice any difference in energy consumption. It gives 30% energy savings in system level. EXCELLENT ENERGY EFFICIENCY In a normal hotel room, the GRAND Vari consumes as much energy as one LED lamp. The EC motor allows a stepless adjustment of the fan from 0 to 100%. The annual energy consumption is only a fraction of any previous solution. The EC grille has two parts for intake and return air supply The EC grille has two parts for intake and outtake air supply with fresh air. The non-mixed airflows from the room allow a larger logarithmic temperature difference between air and water compared to a conventional solution. The new EC grille allows draught-free air supply, as air is forced along the ceiling. 4

Fresh air BENEFITS OF GRAND VARI EC grille Draught-free cooling. Excellent logarithmic temperature difference between air and water. Fresh air is connected in the rear side of the unit. EC fan Adjustment of fan and valve 0 100%. Fan section with ball bearings. Fresh air CHILLER SOLUTION Operation and maintenance The filter is cleaned by vacuum cleaner through the raised grille. Remove of the condense water either with a pump or free drainage. Factory-tested for commissioning. Five-row coil is an big advantage in the district cooling. Manual balancing is history Vari PRO TM and AB-QM. Water flow setting with new Vari PRO TM controller. Automatic balansing. No overflows. INSTALLATION OPERATION MAINTENANCE Use Mini AHU instead of ducted fancoils! High efficiency and low sound level allows to use setpoint changes effectively in water chiller. HIGH-QUALITY MINI AHU GRAND Vari air handling units are produced from high-quality materials. Because of continuous development and careful testing, the units are very energy efficient and produce a low sound level. Carbon emissions and life cycle costs are only a fraction compared to any other product on the market. The units require only a little of service. They can be delivered with valves from the factory. VARI PRO TM REVOLUTION User-friendly and clear functions. Energy use display. Maintenance and fault notifications. Low operating noise and energy-efficient. Localised information output and via building automation systems. Quick to install. Read more: varipro.chiller.fi

VARI TM -CASSETTE FAN COILS COMFORT FOR LARGE AREAS The Vari cassette fan coil is the first new generation cassette fan coil for false ceiling structures. The product is protected by several international patents. New EC fan technology provides stepless fan speed control. Units are controlled by Vari PRO TM wall controllers. EXCELLENT ENERGY EFFICIENCY The Vari consumes less energy than a LED lamp; only 4 watts in a living or office room. The filter in the Vari cassette fan coil is four times larger than in the previous model. Regular cleaning is easy. DRAUGHT-FREE AND COMFORTABLE INDOOR AIR The new EC grille allows a draught free and comfortable indoor climate. The power of the EC motor can be adjusted from 0 100%. 6

BENEFITS OF Vari TM EC grille Significant energy savings. Tested in an independent laboratory. Comfortable indoor climate, no sense of draught. EC fan Controlled by voltage signals. Dedicated electronics for optimization of fan and valve operation. The unit s coil 3-row deep (66 mm) coil allows the use of district cooling water. Water side circuits according to the customer needs. Operation and maintenance Large filter surface enables low service costs. With a condensation pump or free drainage. Modbus available as an option. Manual balancing is history Vari PRO TM and AB-QM. Water flow setting with new Vari PRO TM controller. Automatic balansing. No overflows. INSTALLATION OPERATION MAINTENANCE INSTALLATION, OPERATION AND MAINTENANCE The Vari is delivered in an ecological cardboard package that serves as an installation shield. The unit is mounted on the ceiling surface from the corners of the bottom plate, after which the package is removed. Maintenance of the unit is very easy. Removal of condensation water is done with free drainage or a condensation pump. VARI PRO TM REVOLUTION User-friendly and clear functions. Energy use display. Maintenance and fault notifications. Low operating noise and energy-efficient. Localised information output and via building automation systems. Quick to install. Read more: varipro.chiller.fi

STUDIO VARI TM -FLAT BLOWER UNITS NEW EC TECHNOLOGY STUDIO Vari TM flat blower units are equipped with modern EC technology and 6-row coil. This solution is excellent for big temperature differences in district cooling. COMPLETE DELIVERY STUDIO Vari is a new fan coil equipped with high quality EC motor. Energy consumption is very low thanks to the modern fan and coil technologies. Manual balancing is history Vari Pro and AB-QM. Water flow setting with new Vari PRO TM controller. Automatic balansing. No overflows. BENEFITS OF STUDIO Vari TM EC fan controlled by voltage signals 6-row coils, optimized for district cooling. Coil circuiting according to customer needs. Dedicated electronics for optimization of fan and valve operation. With a condensate pump or free drainage. 8

GIANT VARI TM FLAT BLOWER UNIT WITH WATER CIRCULATION SCALABLE SOLUTIONS FOR DEMANDING AIR CONDITIONING GIANT Vari TM flat blower units with EC technology are suitable for example for shops, small computer rooms, control rooms and offices. These units are designed for higher cooling capacity ranges than the and Studio series. The GIANT Vari series allows a very flexible installation and guarantees that the desired room temperature is accurately maintained. Units delivered with factory-installed 2- or 3-way valve. The GIANT Vari series uses some of the same components as Vari and GRAND Vari. This makes installation easier when changing from one series to another VARIOUS INSTALLATION METHODS The construction of the unit is very flexible. Installation methods available: standing on the floor, blowing upwards or downwards, or ceiling models. BENEFITS OF GIANT Vari TM EC-fan controlled by voltage signals 6 deep coils have been optimized for district cooling. Several auxiliary devices for various installation methods. Flexible frame construction. With a condensate pump or free drainage.

Box VariTM Mono 20 80 Box VariTM Double 100 160 VARITM -CASSETTE FANCOILS Mono VariTM 10 Double 20EL 40EL 60EL 80EL 100EL 120EL 160EL * Cap total / sensible kw ** Cap total / sensible kw 2,1/1,4 1,7/1,2 2,4/1,5 2/1,4 2,6/1,6 2,1/1,5 3,3/2,1 2,6/0,9 3,7/2,3 3/2,1 3,9/2,5 3,3/2,2 Airflow l / s *** Sound level db(a) 70 25 70 25 70 25 105 24 105 24 105 24 Running power W 5 5 5 9 9 20L 20L * Cap total / sensible kw 1,3/0,9 ** Cap total / sensible kw 1/0,8 Airflow l / s *** Sound level db(a) 85 30 40L 40L 60L 60L 80L 80L 100L 100L 120L 120L 1,5/1,1 1,2/1 Airflow l / s 110 *** Sound level db(a) 35 Running power W 9 2,8/1,8 2,3/1,6 3/1,9 2,6/1,7 3,5/2,4 3/2,2 4,2/2,7 3,4/2,4 4,5/2,9 3,7/2,6 85 30 85 30 85 30 126 30 126 30 126 30 1,5/1,2 1,2/1 135 *** Sound level db(a) 42 Running power W 16 11 160M 160M 3,0/2 2,4/1,8 3,4/2,2 2,7/2 3,7/2,4 3,1/2,1 3,9/2,7 3,4/2,5 4,7/3,1 3,8/2,7 5,1/3,3 4,2/2,9 110 35 9 110 35 9 110 35 9 145 34 14 145 34 14 145 34 14 20H 40H 60H 80H 100H 120H 20H 40H 60H 80H 100H 120H * Cap total / sensible kw ** Cap total / sensible kw Airflow l / s 160L 2,4/1,6 1,9/1,4 Running power W 7,5 7,5 7,5 7,5 11 11 20M 20M 40M 40M 60M 60M 80M 80M 100M 100M 120M 120M * Cap total / sensible kw ** Cap total / sensible kw 9 160H 160H 3,1/2,2 2,5/2 135 4/2,6 3,2/2,3 135 4,5/2,9 3,6/2,6 135 4,6/3,2 3,7/2,8 178 5,6/3,7 4,5/3,3 178 6,2/4 5,1/3,5 178 42 16 42 16 42 16 39 19 39 19 39 19 20EH 40EH 60EH 80EH 100EH 120EH 160EH 20EH 40EH 60EH 80EH 100EH 120EH 160EH * Cap total / sensible kw 2,3/1,6 4,2/2,9 5/3,4 5,7/3,7 6,2/4,3 7,8/5,2 8,8/5,7 ** Cap total / sensible kw Airflow l / s 1,8/1,5 180 3,4/2,6 180 4,0/3 180 4,6/3,3 180 4,9/3,9 265 6,3/4,6 265 7,2/5,1 265 *** Sound level db(a) 51 51 51 51 50 50 50 Running power W 29 29 29 29 43 43 43 VariTM mono and VariTM double units are equipped with EC grille and EC fan technology. Technical data: Electricity V - ph - Hz: Dimensions of the unit, mm: 230-1 - 50 585 x 585 x 300 or 585 x 1178 x 300 Dimensions of the grille, mm: 625 x 625 x 40 or 1225 x 625 x 40 H VariTM is without condensate pump. Air flow determines the water flow. Air and water flow varies 0 100 %. * Air 27 / 50 C / %, water 7 / 12 C ** Air 25 / 50 C / %, water 7 / 12 C *** Sound level 10 m2 Sabine Detailed information on heating / cooling and heating solutions from Chiller Oy s sales. 10

GRAND VARI TM 70 & 100 -FAN COILS GRAND Vari TM 70-EL 100-EL * Cap total / sensible kw 2,1/1,4 ** Cap total / sensible kw 1,7/1,3 Airflow l / s 61 *** Sound level db(a) 22 Running power W 4,7 70-L 100-L * Cap total / sensible kw 1,8/1,2 2,4/1,6 ** Cap total / sensible kw 1,4/1,1 1,9/1,4 Airflow l / s 54 70 *** Sound level db(a) 30 24 Running power W 8,4 6 70-M 100-M * Cap total / sensible kw 2,3/1,5 2,8/1,9 ** Cap total / sensible kw 1,8/1,3 2,2/1,7 Airflow l / s 71 85 *** Sound level db(a) 37 29 Running power W 16 8,7 BO 70-H 100-H * Cap total / sensible kw 2,7/1,8 3,6/2,4 ** Cap total / sensible kw 2,1/1,6 2,9/2,1 Airflow l / s 88 114 *** Sound level db(a) 42 36 Running power W 26 16,6 70-EH 100-EH * Cap total / sensible kw 2,8/1,9 4,3/2,9 ** Cap total / sensible kw 2,2/1,6 3,4/2,5 Airflow l / s 93 142 *** Sound level db(a) 44 41 Running power W 31 29 GRAND Vari TM units are equipped with EC grille and EC fan technology. Technical data: Electricity, V - ph - Hz: 230-1 - 50 * Air 27 / 50 C / %, water 7 / 12 C Dimensions of the unit, mm: 700 x 1000 x 250 tai 1000 x 1000 x 250 ** Air 25 / 50 C / %, water 7 / 12 C Dimensions of the grille, mm: 736 x 210 x 36 tai 1036 x 210 x 36 *** Sound level 10 m 2 Sabine Air flow determines the water flow. Air and water flow varies 0 100 %. Detailed information on heating / cooling and heating solutions from Chiller Oy s sales.

STUDIO VARI TM -FLAT BLOWER UNIT STUDIO Vari TM 9-EL 10-EL 11-EL 13-EL 16-EL 17-EL * Cap total / sensible kw 1,6/1 2,4/1,5 2,7/1,8 4,2/2,7 ** Cap total / sensible kw 1,4/1 2/1,4 2,2/1,6 3,4/2,4 Airflow l / s 45 65 74 114 *** Sound level db(a) 26 25 25 29 Running power W 4 4 4,3 8 9-L 10-L 11-L 13-L 16-L 17-EL * Cap total / sensible kw 2,3/1,5 3,2/2 3,8/2,5 5,7/3,6 ** Cap total / sensible kw 1,9/1,3 2,6/1,8 3,1/2,2 4,6/3,3 Airflow l / s 65 88 105 159 *** Sound level db(a) 31 31 34 35 Running power W 5,5 6 7 13 9-M 10-M 11-M 13-M 16-M 17-M * Cap total / sensible kw 2,9/1,8 3,6/2,3 4,9/3,1 4/2,6 6,2/4 7,1/4,6 ** Cap total / sensible kw 2,3/1,6 3/2,1 4/2,8 3,3/2,3 5,1/3,6 5,8/4,1 Airflow l / s 83 103 144 111 177 206 *** Sound level db(a) 35 35 44 35 36 46 Running power W 8,6 8 18 7,8 16 26 9-H 20H 10-H 40H 11-H 60H 13-H 80H 16-H 100H 17-H 120H 160H * Cap total / sensible kw 3,8/2,4 5,2/3,3 6,3/4,1 6,3/4 9,5/6,1 9,4/6 ** Cap total / sensible kw 3,1/2,2 4,2/3 5,1/3,6 5,1/3,6 7,7/5,4 7,6/5,4 Airflow l / s 116 154 197 184 287 287 *** Sound level db(a) 44 45 52 47 48 54 Running power W 18 19 37 22 39 56 9-EH 20EH 10-EH 40EH 11-EH 60EH 13-EH 80EH 16-EH 100EH 17-EH 120EH 160EH * Cap total / sensible kw 4,6/2,9 6,2/4 7,8/5 7,4/4,7 11,4/7,3 12,6/8,1 ** Cap total / sensible kw 3,7/2,6 5/3,6 6,3/4,5 6/4,2 9,2/6,5 10,2/7,2 Airflow l / s 145 192 254 222 358 407 *** Sound level db(a) 49 51 60 51 53 61 Running power W 30 33 71 36 63 114 STUDIO Vari TM units are equipped with EC fan technology. Technical data: Electricity V - ph - Hz: 230-1 - 50 * Air 27 / 50 C / %, water 7 / 12 C ** Air 25 / 50 C / %, water 7 / 12 C *** Sound level 10 m 2 Sabine Dimensions of the unit, mm: 890 1920 x 450 x 250 Air flow determines the water flow. Air and water flow varies 0 100 %. Detailed information on heating / cooling and heating solutions from Chiller Oy s sales. 12

GIANT VARI TM -FLAT BLOWER UNIT GIANT Vari TM 700-EL 1300-EL * Cap total / sensible kw 5,7/3,8 10,6/7 ** Cap total / sensible kw 4,7/3,5 8,5/6,3 Ilmamäärä l / s 170 306 *** Äänitaso db(a) 46 50 Puhaltimen ottoteho W 28 56 700-L 1300-L * Jäähd. teho kokon. / tuntuva kw 8,1/5,4 15,1/10 ** Jäähd. teho kokon. / tuntuva kw 6,5/4,8 12/9 Ilmamäärä l / s 255 459 *** Äänitaso db(a) 54 58 Puhaltimen ottoteho W 45 89 700-M 1300-M * Jäähd. teho kokon. / tuntuva kw 10,4/6,9 19,3/12,9 ** Jäähd. teho kokon. / tuntuva kw 8,2/6,1 15,4/11,5 Ilmamäärä l / s 342 615 *** Äänitaso db(a) 60 64 Puhaltimen ottoteho W 86 172 20H GIANT Vari TM units are equipped with EC fan technology. Technical data: Electricity V - ph - Hz: 230-1 - 50 * Air 27 / 50 C / %, water 7 / 12 C ** Air 25 / 50 C / %, water 7 / 12 C *** Sound level 10 m 2 Sabine Dimensions of the unit, mm: 1050 x 730 x 450 mm Dimensions of the chambers, mm: 425 x 730 x 450 mm Air flow determines the water flow. Air and water flow varies 0 100 %. Detailed information on heating / cooling and heating solutions from Chiller Oy s sales.

POOR BALANCING COSTS MORE MONEY EASY COMFORT WITH AB-QM Conventional distribution designs using constant flow systems or variable flow systems must be manually balanced to ensure there is enough pressure to reach those locations farthest from the pumps. Manual balancing cannot adapt to varying demand, causing over-pumping and low delta T syndrome (where the chilled water is returned to the chiller still cold), keeping operating costs closer to 100% even when cooling demand is only half of that. The main challenge in using conventional distribution systems is that temperature regulation becomes unstable, varying similar to on/off control, reducing users thermal comfort, leading to additional cooling demand and higher costs. Pressure independence easy comfort with AB-QM The AB-QM from Danfoss combines three functions in one valve body. Pressure Controller ensures pressure independence. Automatic Balancing limits maximum flow rate. Control Valve precisely regulates flow to match demand. SERVICE NEXT TM -OVERALL CONCEPT OPTIMIZATION, MONITORING AND COST-EFFICIENCY The Service Next overall concept is a service for realtime supervision and control. It can be used to prevent unit malfunction and optimize the unit s functions to the best possible range of coefficient of performance. Service Next helps to forecast, among other things, the need for service. 14

- cassettes and fancoils for the indoor climate solutions - heat pumps for the needs of processes and buildings - for controlling groups of units - Three-in- one room controllers - water chillers and cold water statations for the needs of processes and buildings - for monitoring the coefficient of performance and leak of refrigerant - fancoils for the indoor climate solutions - precision air-conditioners for efficient cooling of computer and data rooms Chiller Oy offers the Service Next overall concept free of charge for two years. The end user only has to provide an Internet connection to the unit without any extra equipment or software. The operative technical support - Help Desk - is part of the service; there is no need for guesswork on the site. Service Next provides reports on, e.g. energy consumption, alarms, refrigerant leaks and utilization rates. All events, regulations and disorders will be stored in the systems database. Information about those factors allows for life cycle control and optimisation. Savings can only be achieved by measuring and analyzing.

HELPDESK SERVICE OUR SALES AND MAINTENANCE NETWORK AT YOUR SERVICE N00287288_B1 Chiller Oy reserves right to changes. Chiller Oy is one of Europe s leading manufacturers of energy-efficient and optimized air conditioning solutions. Design and service are always based on the customers specific requirements. For more information, please contact our head office or foreign business partners. Read more: www.chiller.fi/en Head office Estonia Norway Sweden Chiller Oy Louhostie 2 FI-04300 Tuusula Finland Tel. + 358 9 2747 670 info@chiller.fi www.chiller.fi Dubai Chiller Air Conditioning Solutions LLC P.O. Box 282071, Dubai United Arab Emirates Tel. 04 315 2397 Climaref OÜ Tartu kaarel@climaref.ee www.climaref.ee Hong Kong Eco Living Limited Unit G, 1/F., Kam Po Court No.2 Hoi Pong Square Sai Kung, N.T. HONG KONG Lithuania UAB Leslat Kaunas leslat@takas.lt www.leslat.lt Chiller Norge AS Oslo Tel. +47 95 86 89 18 rune.nordgard@chillernorge.no www.chillernorge.no Poland StepSystems Sp. z o.o. Radom biuro@ stepsystems.pl www.stepsystems.pl Chiller Sverige AB Stockholm Tel. +46 8 54 50 2080 info@chillersverige.se www.chillersverige.se Forsberg & Tibell Kyl AB Jönköping Tel. +46 36 132 650 info@kyla.nu www.kyla.nu