VM-3000 Mercury Vapor Monitor

Similar documents
Mercury Vapor Monitor VM-3000

VM-3000 Mercury Vapor Monitor

stationary dose rate measuring systems

Constant climate chambers

PG 990 Atomic Absorption

Constant climate chamber with humidity

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Constant climate chambers

Constant climate chambers

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Constant climate chamber with ICH-compliant illumination

Series 9000 Total Hydrocarbon Analyzer

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

A New Standard of Excellence

CLEAN-LASERSYSTEME GMBH

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

PUV, PIR and PFO Series BROCHURE

SP-3800AA Atomic Absorption Spectrophotometer

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Gas detection for your safety

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Specification for On-Line UPS Battery Monitoring and Data Management System

portable gas analyser

Customised HPLC Systems for Highest Performance

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

SEC Signature Process Gas Analyzer

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

HSD Dry Cabinet

Specifications Wavelength Range: 190 nm to 800 nm continuous

Operate the Mutli-Gas Monitor PID

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

AS950 REFRIGERATED SAMPLERS

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Parameterisable compact fault annunciator with permanent display

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Variable Temperature Options for Optical Experiments

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Chemistry Instrumental Analysis Lecture 4. Chem 4631

WASTEWATER Online UV%Transmission Analyzer

Pressure measuring instruments

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Infrared Moisture Balance (FD-660)

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Standard Specifications

Dräger Polytron Pulsar 2 Open Path Gas Detector

Infrared Moisture Determination Balance FD-610. Operating Manual

DIESEL Engine Fire Pump Controllers Features

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Model KBWF 240 Growth chambers with light and humidity

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Dräger PIR 7200 Toxic Gas Detection Transmitter

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace AAS analysis for routine laboratories

HSD Dry Cabinet. Outstanding performance

Microtherm Heat Stress WBGT

Model KBWF 720 Growth chambers with light and humidity

ice 3000 Series Atomic Absorption Spectrometers Flame and furnace analysis for routine laboratories

SAM-MAX Refrigerant Monitors

Model gffoz Process Ozone Sensor (In-Line)

AS950 PORTABLE SAMPLERS

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Dräger Polytron 7000 Fixed gas detector

Dräger Pac 6000 Single-Gas Detector

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Specifications Minimum Typical Maximum Unit

Advanced FireAlarm Panel 1-4Loop

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

incubator, the best in its class

ECOSENSORS 2015 PRICE LISTr-2 PORTABLE AND FIXED AMBIENT OZONE SENSORS

COMPLETELY AUTOMATED HYDROLYSIS

ELD500 PRECISION LEAK DETECTOR

Constant climate chambers

NanoReady. Micro UV-Vis Spectrophotometer

EC 160 CO 2. Incubator

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

HSD Dry Cabinet. Outstanding performance

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

LaserMethane mini (LMm)

Speed and Frequency Seite 1 von 7

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

AAnalyst 700 Atomic Absorption Spectrometer

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Transcription:

MERCURY INSTRUMENTS Analytical Technologies VM-3000 Mercury Vapor Monitor Continuous mercury measurement in air and other gases Direct reading mercury vapor meter Proven reliable detection method: UV absorption (CVAAS) Measuring ranges 0-100 / 0-1000 / 0-2000 µg/m³ Easy operation Automatic zero adjustment Sensitivity: 0.1 µg/m³ Integrated battery for mobile operation (option) integrated Data logger (option)

Fields of application The VM-3000 Mercury Vapor Monitor serves for continous measurement of the mercury concentration in air and other gases in laboratory as well as industry and mobile applications. It has a wide variety of applications: work place monitoring (threshold limit value) exhaust air monitoring in mercury recovery plants emission monitoring in the chemical industry ground air screening of contaminated soil quality control of hydrogen and natural gas detector for laboratory applications Measuring principle The mercury concentration is measured in an optical cell made of fused silica. A maintenance-free membrane pump continuously feeds the sample gas to the optical cell where UV absorption measurement takes place at a wavelength of 253.7 nm. This so-called cold vapor atomic absorption spectroscopy (CVAAS) measuring method is extremely sensitive for mercury determination and has been used successfully for many years. In contrast to the occasionally propagated atomic fluorescence spectroscopy (AFS) method it is low in interference and requires neither an amalgamation step nor expensive noble gases as carriers. VM-3000 Flowchart Analytical Performance EDL inside the VM-3000 The VM-3000 uses a high-frequency driven electrodeless Hg low pressure lamp (EDL) as UV source. It generates emission lines of an extremely narrow bandwidth which are congruent with the the absorption lines of the Hg atoms. Cross-sensitivities are thus minimized. The extremely high stability of the UV source in the VM-3000 is a result of the reference beam feedback control method. Total background noise is less than 0.1 µg/m³. To prevent temperature drift both the lamp unit and the detectors are temperature stabilized. The optical cell heating makes it insensitve to water vapor.

Special Features Metal housing with sturdy handle Option: Rack version with mounting brackets for 19 racks Membrane pump with long service life Input filter with teflon membrane Factory-calibrated Stable optical bench Precise and proven technique: Mercury Vapor Monitor VM-3000 The soul of the machine: The optical bench inside the VM-3000 Easy to operate The user controls the VM-3000 by menu-guided inputs via a waterproof membrane keypad. After switch-on the light source is stabilized (approx. 1-15 minutes). When the measurement mode is started, a zero adjustment is first carried out automatically. Then the analyzer switches to measurement and continuously indicates the measured mercury concentration of the gas as a numerical value and a graphic bar. The following settings are possible in the parameters menu: duration and repeat interval of the zero adjustment selection of the concentration unit (μg/m³) or ppb) measuring range (0.1-100, 0-1000, 0-2000 μg/m³) input of three different alarm levels calculation of a mean value over three freely selectable time intervals printer activation sample dilution factor (if required) Display and Output of Measurements The result of the measurement is displayed on an LCD in real time, both numerically and graphically and is output as an electrical signal of 4-20 ma. The device has outputs for alarm, status and measurement values for full integration in plant control systems. The device also features a serial interface (RS 232 / USB) for data transfer to a PC or Laptop. (Software "Hg-Transfer" included)

Extensions The VM-3000 Mercury Vapor Monitor is the basic model of our modular system for mercury analytics. An optional reaction unit and activation of the appropriate software turn it into a laboratory unit for liquid samples (Mercury LabAnalyzer-254). Multiplexer Operation The VM-3000 can be combined with a multiplexer unit for automatic monitoring of several measurement points. See information about the Mercury Monitoring System (MMS) in a special broschure. Self Diagnosis System If an important component of the VM-3000 malfunctions the user is warned via the display (blinking messages and via output signals e. g.: clean cell lamp low battery alarm Battery Operation For operation independent from mains power the VM-3000 is also available with a built-in rechargable battery and a charger unit. This option allows mobile battery-powered applications of up to approx. 4 hours. Data Logger Function A data logger function can be integrated into the VM-3000 as an option. Up to 30 000 readings can be stored in the data memory. The logging interval can be set from 1-999 seconds resulting in a total recording capacity of 8 hours to 346 days. The stored data can be read out with a PC using the serial interface of the analyzer (RS232 or USB). Data transfer software is incuded (Hg-Transfrer).

Dustproof enclosure The VM-3000 with dustproof enclosure is now available in our regular product line. It is meant for stationary wall or stand mounting. All necessary cables and tubings are fed through the dustproof cable glands on the bottom of the enclosure. The VM-3000 unit has all of its electrical in- and outputs as well as the sample gas in- and outlet on the rear. They are easily accessible by simply swinging open the enclosure.

Technical Specifications Measuring principle: UV-Absorption Wavelenght: 253.7 nm UV source: Electrodeless low-pressure mercury lamp Stabilization: Reference beam and thermal Optical cell: fused silica (Suprasil), 23 cm long, heated to avoid condensation Measuring range: 0... 100 µg / m³; 0... 1000 µg / m³; 0-2000 µg / m³ Sensitivity: 0.1 µg / m³ Response time: <1 sec Computation of mean values: autom. via three freel selectable time intervals Alarm: when concentration is exceeded, 3 levels programmable Status alarm: Measuring cell soiled, battery state, UV source Control pad: waterproof membrane keyypad Measurement display: Graphic dipslay with background lighting Signal outputs: 4... 20 ma; serial: RS 232 / USB, bidirectional; parallel (Centronics) Pump: membrane pump, approx. 2 L/min. Filter: PFTE, 1µ, 47-50 mm diameter Power supply: 110... 240 V (50 / 60 Hz) Battery operation: optional, 12 V rechargeable batteries integrated, 4h cpacity Data logger function: Up to 30 000 readings Power consumption: 40 W Dimensions: 45 x 15 x 35 cm (W x H x D) Weight: approx. 7 kg 2017 Mercury Instruments GmbH, Mercury Vapor Monitor VM-3000 Specifications subjet to change without notice Distributed by: Mercury Instruments GmbH Analytical Technologies Liebigstrasse 5 85757 Karlsfeld / Germany mail@mercury-instruments.de Tel.: +49(0)8131-50 57 20 Fax.: +49(0)8131-50 57 22 www.mercury-instruments.de