Radon Detection Specialists, Inc. Love the Lungs You re With

Similar documents
Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Certificate of Completion

Radon Detection Specialists, Inc.

Certificate of Completion

Certificate of Completion

Radon Measurement Survey Report. Rollins Elementary School 950 Kane Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Oak Park Elementary School 1200 Front Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Krug Elementary School 240 Melrose Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. McKnight School Service Center 417 Fifth Street Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Fred Rodgers Magnet Academy 501 College Avenue Aurora, Illinois Prepared For:

Radon Measurement Survey Report. Waldo Middle School 56 Jackson Street Aurora, Illinois Prepared For:

Illinois School District & Daycares

Illinois School District & Daycares

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

Ohio Department of Health, Bureau of Environmental Health and Radiation Protection, Radon Licensing Program. School Radon Testing Checklist

Comprehensive Short-Term Radon Survey Report

RADON PLAN. Eugene School District 4J Facilities Management 715 West Fourth Avenue Eugene, OR

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

David F. Metzger 121 N. Leavitt Rd. #313, Amherst, OH Certified Radon Tester Ohio License #: RS340 & RC213; NRPP ID#: RT

Measurement Devices. Topic 5 - Audio 56

Bethel School District Radon Testing Plan

RADON LAZERWEB SERVICES


LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

In Schools. Revised Edition. oepa. Aa Bb Cc Dd Ee Radon Measurement. Air And Radiation (6604J)

CLACKAMAS EDUCATION SERVICE DISTRICT HEALTHY AND SAFE SCHOOLS PLAN

Pennsylvania Citizen s Guide to Radon. Test your home for radon it is easy and inexpensive.

A Citizen s Guide To Radon

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Radon. In Your Home SAMPLE

Buying a New Home? How to Protect Your Famil... Page 1 of 6

Woodlin Elementary School Date of Report March 14, 2018

STUDY #3 IN A SERIES OF REPORTS ON RADON IN BC HOMES. Castlegar: COMMUNITY-WIDE RADON TESTING RESULTS AS PART OF ITS. PROGRAm

C-NRPP Quality Assurance Guidance for Radon Test Devices

Conducting and Assessing Radon Surveys in Schools & Commercial Buildings

Dealing With RADON in Real Estate Transactions

Illinois Emergency Management Agency

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

RADON SCREENING SURVEY FOLLOW-UP WHITTIER WOODS CENTER Whittier Boulevard, Bethesda, Maryland 20817

radon Keeping your home safe from radon

RADON SCREENING SURVEY FOLLOW-UP GREAT SENECA CREEK ELEMENTARY SCHOOL Dairymaid Drive, Germantown, Maryland 20874

RULES AND REGULATIONS FOR RADON CONTROL

ALL RADON TESTS WERE SIGNIFICANLY BELOW

2.3 Definitions, General Provisions, and Radon Standards

RADON SCREENING SURVEY FOLLOW-UP CONCORD CENTER Hidden Creek Rd, Bethesda, Maryland 20817

Multnomah Education Service District

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM

Consumer s Guide To Radon Reduction

Testing for Elevated Radon in Oregon Schools

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

NSAW Radon Assessment 2017 QUESTIONS AND ANSWERS

Dealing With RADON in Real Estate Transactions

MCPS RADON TESTING. Executive Summary: Festival Center. Date of Test Report: 4/15/2016 Round of Testing: Initial Follow-up Post Remediation

EagleRidge High School. Radon Testing Plan

Testing for Elevated Radon in Oregon Schools

Radon Testing Results. City Hall

CHAPTER 240. RADON CERTIFICATION

Guide for Radon Measurements in Residential Dwellings (Homes)

Radon Measurement Report

A Citizen s Guide To Radon The Guide To Protecting Yourself And Your Family From Radon

Radon Environmental Health Program Health Canada, Alberta Region. Bradley Hameister October 4, 2011

Testing for Elevated Radon in Oregon Schools Protocol and Plan

Special Attention of: Notice H All Multifamily Hub Directors All Program Center Directors All Project Managers All Field Office Directors

Radon YOU: What you need to know to protect you and your family

WORKING. TOGETHER to PREVENT LUNG CANCER. A Guide to help you with testing your Child Care Centre for Radon

MAKE MOLD UNWELCOME IN YOUR HOME

Table of Contents EPA (Radon).1 CPSC (Safety) 43 Business.48

What you need to know

REAL ESTATE TRANSACTIONS

REAL ESTATE TRANSACTIONS

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

Home Buyer s and Seller s Guide to Radon

INDOOR RADON POLICY AND PROCEDURES LAWLER WOOD HOUSING, LLC

YOU: What you need to know to protect you and your family

Property of Aztec Home Services LLC

Locations must be selected where the detector is not to be disturbed during the measurement period.

EPA estimates that radon causes thousands of lung cancer deaths in the U.S. each year.

A Citizen s Guide To Radon

Quality Assurance Plan for Conducting Radon Measurements

Consumer s Guide To Radon Reduction How to fix your home

Radon Survey Final Report

Public Review: MAMF - Proposed Revision 09/2016. Protocol for Conducting Measurements of Radon and Radon Decay Products in Multifamily Buildings

Home Buyer s and Seller s Guide to Radon

Radon Survey Summary Report

Home Buyer s and Seller s Guide to Radon

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

CARST Guideline for Conducting Radon Measurements as Part of a Real Estate Transaction of Residential Dwellings in Canada (draft)

Connecticut Radon Measurement Training Program

RADON What You Need to Know

RADON TESTING: HEALTH GUIDELINES

RADON: IS IT IN YOUR HOME?

MEDICAL GEOLOGY/GEOCHEMISTRY

Safety Siren Pro Series3 Radon Gas Detector

RADON. In Search of Answers

RADON: IS IT IN YOUR HOME?

Transcription:

630-325-4443 800-244-4242 kws@radonresults.com Commercial Radon Survey Report Client: Pleasantdale School District 107 8100 School Street La Grange, Illinois 60525 Survey Date: August 27, 2014 to August 30, 2014 Follow-Up Measurement RDS-R-002 Prepared by: Kirsten Schmidt IL Professional Radon License RNI2006204 Licensed for Residential and Commercial Radon Testing

8100 School Street, La Grange, Illinois 60525 Survey Date: 8/27/14 to 8/30/14 Table of Contents Basics of Radon and Radon Health Impacts... 3 Scope of Work Performed:... 4 Quality Assurance Plan for this Site... 5 Explanation of Device Results and Site Notes... 6 Survey Summary... 7 Appendix A: Site Plan Showing Device Locations... 9 Appendix B: Individual Device Results Table... 10 Appendix C: IEMA Radon Measurement Professional License... 12

Survey Date: 8/27/14 to 8/30/14 page 3 of 12 Basics of Radon and Radon Health Impacts Radon is recognized by the United States Environmental Protection Agency (US EPA) as well as the scientific and medical communities as a Class A carcinogen, accounting for 15,000 22,000 lung cancer deaths annually. Exposure to radon gas is the leading cause of lung cancer among non-smokers. Radon is a naturally occurring, radioactive gas which comes from the soil. It can t be seen, smelled or tasted. The only way to know if the level of radon gas in your building exceeds the recommended action level of 4.0 pci/l is to test. The Department of Nuclear Safety in Illinois requires those testing for radon in commercial buildings, schools and multi-family housing communities, as well as individual residences, to be licensed. The amount of radon in the soil depends on soil chemistry, which naturally varies. Radon levels in the soil can range from a few hundred to several thousands of pci/l (pico Curies per liter of air). The amount of radon that escapes from the soil and enters the building depends on the weather, soil porosity, soil moisture, and the suction within the building. Radon is the leading cause of lung cancer among non-smokers. There is no safe level of radon exposure. Any exposure causes some risk of developing cancer. In two 1999 reports, the National Academy of Sciences (NAS) concluded after an exhaustive review that radon is the second leading cause of lung cancer. Only cigarette smoking poses a greater risk. The NAS estimates that 15,000 to 22,000 Americans die every year from radonrelated lung cancer. That s 10% of all lung cancer deaths annually. The alpha radiation from radon and its decay products cause damage to the sensitive lung tissue. Most of the radiation dose is not actually from radon itself, but rather from radon s chain of short-lived decay products that are inhaled and lodge in the airways of the lungs. These radionuclides decay quickly, producing other radionuclides that continue damaging the lung tissue. Those particles that are retained long enough release radiation and damage the surrounding lung tissue. It is this damage that can lead to lung cancer. What other health risks are related to radon exposure? No other respiratory ailments are linked to radon exposure There are preliminary studies that are looking at the link between radon exposure and the development of Parkinson s and Alzheimer s disease. These are early studies. For more information on this issue, please visit our website and read the press release.

Survey Date: 8/27/14 to 8/30/14 page 4 of 12 Scope of Work Performed: At the request of Catherine Chang, performed short-term follow-up radon testing at Pleasantdale Elementary, located at 8100 School Street, in LaGrange. This scope of work included a 3 day (short-term) radon test in all areas of the subject building demonstrating potentially elevated levels during the measurement taken from 8/18/14 to 8/20/14, as well as additional classrooms chosen at the discretion of the client. A total of 5 continuous radon monitors and 15 passive devices were deployed for this round of followup testing. Of the 15 passive devices deployed, 11 were single measurements, two were duplicates and two were blanks. Testing was conducted from Wednesday, August 27,, 2014 to Saturday, August 30, 2014. The devices used were electret ionization chambers (Eperms ) manufactured by RAD ELEC, Inc. and continuous radon monitors manufactured by Sun Nuclear, model 1027. The report includes a table that details all device measurement results. Because radon levels fluctuate hourly, daily, weekly, seasonally and yearly, these results should not be used to estimate radon levels of rooms that were not tested, or to estimate future radon levels of rooms that were tested. Changes to the building components (both structural and mechanical) can effect radon concentrations. Duplicate devices have been averaged together and demonstrate the precision of the measurements. The testing was conducted in accordance with the Illinois Emergency Management Agency Division of Nuclear Safety (IEMA) and the United States Environmental Protection Agency (USEPA) testing protocols for commercial radon measurements, the device manufacturer s recommendations, and the RDS Quality Assurance Plan.

Survey Date: 8/27/14 to 8/30/14 page 5 of 12 Quality Assurance Plan for this Site Pre-Deployment Testing Strategy Tests will be conducted in the five areas of the subject building which demonstrated potentially elevated levels during the initial measurement, as well as additional classrooms chosen at the discretion of the client. As with the initial measurement, a minimum of 1 detector will be placed every 2000 square feet in open areas. Tests will not be conducted in rooms that are not frequently occupied such as closets, storage rooms, restrooms, hallways, and stairwells unless the space is considered alterable for future regular use, or the measurement is taken for diagnostic purposes. Materials and Methods RDS will use continuous radon monitors and electret ionization chambers to measure radon levels in the air in the above referenced property. The test will comply with all protocols set forth by IEMA, as well as the RDS Quality Assurance Plan. Duplicate tests will be conducted for not less than 10% of the total single devices placed to measure precision. Field blanks will be deployed for not less than 5% of the total number of tests deployed to measure background gamma radiation. Spike tests will be conducted at a minimum of 3% for the total amount of devices deployed (annually) to measure accuracy. The initial voltage reading will take place not more than 24 hours prior to deployment and the final voltage of the devices will be determined within 24 hours of retrieval. RDS will locate devices in such a way to limit unintentional interference from building occupants. A walk-through inspection of the building prior to device deployment will allow RDS to document observations regarding radon entry mechanisms and general building pressure gradients. Test results will be reported in picocuries per liter (pci/l) of air. The effects of the HVAC system on radon progeny will not be evaluated and working level exposure (WL) will not be calculated during this test.

Survey Date: 8/27/14 to 8/30/14 page 6 of 12 Explanation of Device Results and Site Notes Appendix A provides a detailed drawing showing device locations, if an appropriate and accurate drawing is provided by the client and dimensional device plotting is possible. If Appendix A is blank, please refer to the Device Placement columns provided in Appendix B (Room Use and Room Number) as an explanation of device locations. Appendix B identifies all of the devices deployed and their reported radon levels. The results were determined using calculations supplied by the device manufacturer. The radon level continues to be above the recommended Action Level in one location tested, Classroom 144. Air exchange rates for the facility were not available at the time of testing. Air exchange rates can affect the radon concentration based on dilution of radon gas. Notes Regarding Appendix B: All radon levels are expressed in picocuries per liter (pci/l) of air. The building was tested according to IEMA, and USEPA protocol in regard to device placement and analytical methods of calculating results. Tampering was not detected at the time the devices were retrieved, unless noted in the Comment Column. Devices were placed strategically to reduce accidental interference by building occupants. Duplicates are averaged together. It is the average of the two devices upon which decisions with regard to mitigation should be based. Site Notes: 1. The subject building was occupied and fully-functional during this follow-up radon measurement. 2. Unlike the prior measurement period from August 18, 2014 to August 20, 2014, students and staff were present and the HVAC system in the Gym was running continuously during this follow-up measurement. 3. The testing period was noted to have been unremarkable in terms of changes/repairs to the building functionality and the weather, with the exception of one repair made to one plexi-glass covering on the exterior portion of a classroom Univent. This repair was made after the prior measurement, but before this measurement. 4. Upon device retrieval, the continuous monitor deployed in the Gym Office was noted to have been prematurely unplugged and only gathered 42 hours of data. Because this testing device did not meet the minimum 48 hour testing period requirement, results for this device are invalid.

Survey Date: 8/27/14 to 8/30/14 page 7 of 12 Survey Summary The radon levels found during this short-term survey were BELOW the USEPA and IEMA Action Level of 4.0 pci/l with the exception of Classroom 144. Recommendations For locations with invalid measurements or no measurements: Gym Office It is the recommendation of this testing professional to perform another short-term measurement in areas with invalid measurements or no measurements. When elevated levels are not confirmed with short-term follow-up testing: Classrooms 133, 141, and 136 Because the results of this follow-up measurement did not confirm elevated radon levels, long-term testing is recommended in these areas. When elevated levels are confirmed with short-term follow-up testing: Classroom 144 When two short-term measurements confirm elevated radon levels, consultation with an Illinois licensed commercial mitigation firm is recommended. A list of firms licensed for commercial mitigation can be found on the state s website at http://www.state.il.us/iema/radon/commercial. In General: Because different ventilation systems and varying seasonal pressures can influence radon levels, it is the recommendation of this testing professional to perform another short-term survey in two years, in an alternating season, to establish a seasonal baseline. If the levels measured are below the Action Level of 4.0 pci/l, further recommendations will be made to test the building every five years, again, in alternating seasons. A Note About Long-Term Testing The USEPA and IEMA Action Level of 4.0 pci/l is based upon an annual average exposure. As a matter of best practice in radon measurement, a long-term test is the best way to determine occupants' annual exposure, because radon levels vary hourly, daily, weekly, seasonally and over the years. Longterm testing (lasting 90 days to one year) provides a better understanding of building radon concentrations and the risks of exposure to radon.

Survey Date: 8/27/14 to 8/30/14 page 8 of 12 Although the results of this short-term test performed by an Illinois licensed testing professional were below the USEPA and IEMA Action Level of 4.0pCi/L with the exception of Classroom 144, to have a thorough understanding of the occupants risks of exposure, a long-term measurement is always recommended. This type of testing will provide the best indication of radon concentrations and are the basis upon which decisions with regard to mitigation should be made. Should you choose to engage in long-term testing as recommended, please contact us for further details. Radon Detection Specialists is licensed for both residential and commercial radon testing in Illinois. For more information regarding radon testing and mitigation practices in the state of Illinois, please visit the Illinois Emergency Management Agency Department of Nuclear Safety s website, www.radon.illinois.gov, or call the state of Illinois Radon Program at 217-782-1325.

Survey Date: 8/27/14 to 8/30/14 page 9 of 12 Appendix A: Site Plan Showing Device Locations 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 8/27/14 to 8/30/14 page 10 of 12 Appendix B: Individual Device Results Table Electret Device Placement Start Stop Exposure Period Radon Level Control Measurement Duplicate Device Avg. Radon Level Comments Foundation Room Use Room No. Date Time Volts Date Time Volts Days (pci/l) Duplicate/ Blank (pci/l) SGX235 Gym Storage 8/27/14 5:10 PM 307 8/30/14 9:15 AM 294 2.67 1.9 SGS056 Gym Storage 8/27/14 5:10 PM 300 8/30/14 9:15 AM 285 2.67 2.4 Duplicate 2.2 SHB093 Gym Storage 8/27/14 5:10 PM 253 8/30/14 9:15 AM 253 2.67-0.7 Blank SHX317 Classroom 142 8/27/14 5:25 PM 708 8/30/14 AM 684 2.66 3.6 SHF247 Classroom 142 8/27/14 5:25 PM 533 8/30/14 AM 507 2.66 4.2 Duplicate 3.9 SHA798 Classroom 139 8/27/14 5:25 PM 434 8/30/14 AM 421 2.66 1.9 SGS447 Classroom 140 8/27/14 5:30 PM 243 8/30/14 9:30 AM 234 2.67 1.2 SGR727 Classroom 138 8/27/14 5:30 PM 250 8/30/14 9:30 AM 234 2.67 2.6 SHA716 Classroom 137 8/27/14 5:30 PM 321 8/30/14 AM 310 2.66 1.5 Classroom 135 8/27/14 5:35 PM 278 8/30/14 SGX069 All radon levels are expressed in picocuries per liter (pci/l). Results of duplicate devices are averaged to determine the radon level in that location. AM 267 2.66 1.6 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 8/27/14 to 8/30/14 page 11 of 12 Appendix B: Individual Device Results Table Electret Device Placement Start Stop Exposure Period Radon Level Control Measurement Duplicate Device Avg. Radon Level Comments Foundation Room Use Room No. Date Time Volts Date Time Volts Days (pci/l) Duplicate/ Blank (pci/l) SHF321 Classroom 134 8/27/14 5:35 PM 409 8/30/14 9:30 AM 398 2.66 1.5 SGR724 Classroom 134 8/27/14 5:35 PM 192 8/30/14 9:30 AM 192 2.66-0.7 Blank SGX144 Boiler - Office 8/27/14 5:40 PM 210 8/30/14 9:35 AM 199 2.66 1.6 SHA645 Classroom 131 8/27/14 5:40 PM 282 8/30/14 AM 267 2.65 2.4 SGU531 CRM 18560 Classroom 130 8/27/14 Gym Office 8/27/14 5:40 PM 190 8/30/14 5:10 pm 8/30/14 9:35 AM 171 2.66 3.3 9:15 am 1.1 Invalid. Please see Site Notes and hourly results attached. CRM 19460 Classroom 133 8/27/14 5:15 pm 8/30/14 am 3.5 See hourly results attached. CRM 11860 Classroom 141 8/27/14 5:20 pm 8/30/14 9:25 am 1.8 See hourly results attached. CRM 14660 Classroom 136 8/27/14 5:35 pm 8/30/14 9:30 am 2.3 See hourly results attached. CRM 13660 Classroom 144 8/27/14 5:25 pm 8/30/14 All radon levels are expressed in picocuries per liter (pci/l). Results of duplicate devices are averaged to determine the radon level in that location. 9:30 am 7.7 See hourly results attached. 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com

Survey Date: 8/27/14 to 8/30/14 page 12 of 12 Appendix C: IEMA Radon Measurement Professional License 8008 S. Madison Street, Burr Ridge, Illinois 60527 Phone: 630-325-4443 Fax: 630-655-0842 office@radonresults.com