Owner s Manual PCS PRO

Similar documents
Geotech High Vacuum Sampler

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

CLEANING PREPARATION OF STAINLESS STEEL RESERVOIR BEFORE THE SANITIZATION PROCESS

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Panel Mounted Heat Exchangers by Dantherm, Inc.

SERIES PSE-690 INSTALLATION & OPERATION MANUAL IMPORTANT: PSE-690 REMOTE STROBE POWER SUPPLY

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

Ozomax Ltd Ozone generators

Drain Cooler Water tempering device

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

IMPORTANT SAFETY INFORMATION:

Surna 25-Ton Chiller Operating & Maintenance Manual

10810 W. LITTLE YORK RD #130 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE


WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

IMPORTANT SAFETY INFORMATION:

Model NT20e Installation Guide

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

NUOZONE 5 GRAM OEM OZONE GENERATOR MODULE WITH DETATCHABLE ELECTRODE AND POWER & HT SUPPLY

RPI Industries, Inc.

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

InstructIon Manual KrEs EQuIPMEnt stands

BLT-999W-2 Item # 60757

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Quest Power Electric Heat EHS 31 Pro

SEC Signature Process Gas Analyzer

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AIR PURIFIER OZONE GENERATOR

Inline Heater for Solvent or Gas. Installation and Operation Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

USER S OPERATING AND INSTRUCTION MANUAL

10810 W. LITTLE YORK RD. #130 HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

USER MANUAL IMPORTANT

Classic & Deluxe Pants Press SPP-0669 SPP-0670

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

INSTALLATION AND INSTRUCTION MANUAL

HR150 SERIES DEHYDRATOR USER MANUAL

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

IMPORTANT SAFETY INFORMATION:

Easy-Lam School Budget Roll Laminator

OWNERS MANUAL MODEL 451 (-101 & -201)

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

Carbon Dioxide Sample-Draw Detector Operator s Manual

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

GAS MONITOR Model Model

RPI Industries, Inc.

Oil and Water Retort Instruction Manual

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

235H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 235H TM REMOTE STROBE POWER SUPPLY

Blade Series Heat Exchanger Operation and Installation

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

HIDE-A-BLAST HB615X / HB915X INSTALLATION & OPERATION MANUAL IMPORTANT: 6 LED and 9 LED WARNING LIGHT

Item no PERSONAL V2.0. User s Manual

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

LoveGo. Portable oxygen concentrator Your Second Doctor. Table of contents. Lovego, let s go along with love. DO what you want to do

2.4 Cu. Ft. Compact Refrigerator

SAVE THESE INSTRUCTIONS

Instruction Manual Item No.: V~, 60Hz

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Installation & Maintenance Instructions

Operation and Maintenance Manual for the SODRTEK ST 400 Radiant Pre-Heating System P/N

Alarm Tone Generator Model AG17

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

BF33ST/DX BF39ST/DX BF45ST/DX

Xaact Spot. Xaact Hot Spot

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

IMPORTANT SAFETY INFORMATION:

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions

A2Z Ozone, Inc. PRODUCT MANUAL

Environmental Monitoring SmartSlot Card

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Series: MBC1-TC Mini Benchtop Temperature Controller

RK Combustible Gas Transmitter Operator s Manual

Transcription:

Owner s Manual PCS PRO Designed and Manufactured Exclusively by Ozotech, Inc. M43-31017 REV A

Table of Contents 1.0 Limited Warranty 3 2.0 Service Returns 4 3.0 Caution 5 4.0 Theory of Operation 5 4.1 Hi/Low Feature 5 4.2 PCS Corona Discharge Ozone Generation 6 5.0 Operating Conditions 6 5.1 Operating Environment 6 5.2 Input Power Requirements 7 5.3 Figure 1: PCS PRO Ozone Output (mg./hr.) 7 5.4 Figure 2: PCS PRO Ozone Output (%/wt.) 8 6.0 Maintenance 9 6.1 Ozone Generator Maintenance 9 6.2 Corona Discharge Cell Servicing 10 7.0 Spare/Replacement Parts 10 8.0 Fusing 10 9.0 Troubleshooting Guide 11 10.0 Ozone Cell Replacement 12 10.1 Figure 3: PCS PRO component view 12 10.2 Figure 4: PCS PRO typical use diagram 12 2 M43-31017 REV A

1.0 Limited Warranty Ozotech, Inc., warrants the PCS series ozone generators to be free from defects in parts and workmanship for (12) months from date of invoice, under conditions of normal use. The corona discharge cell is warrantied against catastrophic electrical failure for 3 years from date of invoice. All other parts, repaired or replaced, will be warranted only for the remainder of the original warranty period. Ozotech, Incorporated will refund the purchase price, perform repairs or replace equipment, at the option of Ozotech, Incorporated. The warranty shall be null, void, and non-binding upon Ozotech, Incorporated if Ozotech, Incorporated (or authorized service center) determines the cause of malfunction or defect to be a result of: 1) Failure to perform proper maintenance as defined and recommended in this manual. 2) Failure to adhere to and provide proper operating conditions, as defined in this manual, including operation outside of temperature range, operating in wet or dirty environment, operation outside of manufacturer's specifications. 3) Adjustments made by user other than product output flow rate within ranges specified by manufacturer. Ozotech, Incorporated assumes no liability for damages incurred by deliberate or incidental misuse of this product, or damages incurred in transit. M43-31017 REV A

2.0 Service Returns If the need arises to return your equipment for service, the following procedure must be followed to ensure accurate and timely processing of repairs. Obtain the serial number of unit to be returned. Obtain model number/name of unit to be returned. Contact Ozotech, Incorporated and request a Return Material Authorization (RMA) form. Make sure to give the factory representative an accurate and current shipping address. Enclose a description detailing the problem with the unit. Be as specific as possible. After receipt of RMA form, package unit for shipment. Enclose the RMA form with the unit. Use the original packaging materials if possible. Clearly write the RMA number on the outside of the shipping package. Verify that the address is correct and current. Shipments that are not factory authorized will be refused. It is recommended that you ship with a reputable and reliable shipping company, and that the contents of the package are insured. Ozotech, Inc., accepts no responsibility for damage or loss of equipment in transit. ALL FREIGHT CHARGES INTO THE FACTORY MUST BE PREPAID. If the repair is covered under warranty, the factory will pay return shipping charges (surface rates only) to the address listed on the RMA, within the Continental United States. If the repair is not covered under warranty, the returning party is responsible for payment of return shipping and handling charges, as well as labor and equipment costs associated with the repair. 4 M43-31017 REV A

3.0 Caution Read the following safety guidelines thoroughly before attempting to operate or install your equipment. As with all electrical devices, this equipment should never be allowed to come in contact with water. Only qualified personnel should be allowed to set up, maintain and operate this equipment. The equipment must be operated using a properly grounded electrical circuit that is protected by either a fuse or circuit breaker. Ozotech, Inc., assumes no liability for damages or injuries incurred by misuse of this product. Do not use an extension cord to supply power to this equipment. Use a Power Conditioner if line voltage fluctuates outside of specified range. Unit must be disconnected from power prior to performing service or repair. 4.0 Theory of Operation Your PCS PRO ozone generator is a state-of-the-art device designed to produce ozone. The technology utilized to perform this function is PCS Corona Discharge Ozone Generation. Pulse Modulated Corona Discharge generators create ozone through the action of high voltage, low current electrical arcs across an air space. When oxygen (O2) is passed through the air space, some molecules are split, resulting in free oxygen atoms which quickly attach themselves to intact O2 molecules. The result is a very unstable form of oxygen, O3 (ozone). It is the extra atom of oxygen that gives ozone its superior oxidation capabilities. 4.1 Hi/Low Feature Your PCS PRO ozone generator is equipped with a Low and High setting. The Low setting will produce 220mg/hr. ozone, while the High setting will produce 440mg/hr. ozone. Select the setting that best satisfies your needs. Your ozone generator can be seamlessly transitioned between the two settings without additional adjustments. 5

4.2 PCS Corona Discharge Ozone Generation The PCS technology represents the heart of the ozone generator. As opposed to the plate type air dielectric corona generators, the PCS CD cell is biased with a series of pulsed DC, medium frequency signals within a cylindrical environment. The ceramic dielectrics surround a thin barrier of brass and are then surrounded by a stainless coil held to tight tolerances for length and diameter with high voltage applied, the combination of the brass sleeve, ceramic cylinder and coil provide a condensing action to produce ozone. Improvements in the design have led to a method of producing ozone wherein the cell is: 1) Capable of withstanding high voltage inputs without plating; 2) No relative expansion and contraction of the parts; 3) Able to operate at lower temperatures than conventional corona discharge generators thus improving reliability and efficiency without the need for separate cooling water circuitry; 4) Maximum ozone output with minimum high voltage input. Each cell(s) is separately housed within its own stainless holding chamber (manifold) with consideration for maximum efficiency. In other words, all the air that is drawn through the chambers is passed directly through the ozone producing region (corona gap) with little or no waste from improper channeling. See section 6.2 for CD cell service procedure. 5.0 Operating Conditions Your generator requires special operating conditions in order to maintain performance and reliability. Your ozone generator is designed to be operated under a negative or positive pressure situation. Your Ozotech ozone generator has been factory tested to operate at a maximum positive pressure of 5 psi. Warranty coverage of your equipment is contingent upon strict compliance with the operating conditions specified in this manual. 5.1 Operating Environment External It is most important to choose a cool, clean external operating environment. Consideration of these factors should be a priority. Mount your ozone generator in the best possible operating environment that is available at chosen site. If possible, mount in an area that is free of airborne moisture particles. Internal Keep the inside of the generator chassis clean and dry. Dust particles and condensation pose a challenge to the consistent operation of all ozone generators. Make a note to inspect the internal cleanliness of the equipment when you perform your scheduled maintenance. For further information refer to section 6.0. 6

5.2 Input Power Requirements Ozotech, Inc., offers the PCS PRO ozone generator in a variety of configurations to accommodate a wide range of applications. Configurations include a standard AC to DC wall transformer, a cigarette lighter adapter or twisted wire for connection to a hard 12 VDC source such as a car, boat or RV battery circuit. Most supply voltages fluctuate, so it is necessary to monitor your voltage and assure it is within acceptable variance values listed below. Voltage = (Specified) 11.7 VDC to 13.9 VDC Frequency = Not applicable Power Consumption = 700mA to 1.3A @12vdc (8.4 to 15.6 watts) nominal 5.3 PCS PRO Ozone Output (mg./hr.) PCS PRO Ozone Output (Ambient Air) Ozone Output (mg./hr.) 500 400 300 200 100 0 Low Sejng High Sejng 4 SCFH 8 SCFH 10 SCFH 4 SCFH 8 SCFH 10 SCFH Figure 1: PCS PRO ozone output measured in mg./hr. 7

5.4 PCS PRO Ozone Output (%/wt.) PCS Pro Ozone Output (Oxygen) 1400 Ozone Output (mg./hr.) 1200 1000 800 600 400 200 0 Low Sejng High Sejng 2 SCFH 8.5 SCFH 2 SCFH 8.5 SCFH Figure 2: PCS PRO ozone output measured in %/wt. 8

6.0 Maintenance The PCS generators are delivered factory tested, calibrated, and adjusted for maximum efficiency and long life. Simple maintenance and appropriate operating conditions are the only requirements to keep the unit functioning within manufacturer's specifications. Performing any other modifications or adjustments to internal components will cause the unit to function outside of manufacturer's specifications, and will cause damage to the unit not covered under terms of warranty. 6.1 Ozone Generator Maintenance Frequency of Maintenance Every 4800 hours (6 months) To maintain the Ozone Generator: 1. Disconnect unit from power source. 2. Remove front cover. 3. Inspect the inside of the generator for dust and moisture. 4. Thoroughly clean and dry the inside of the generator. 5. Replace front cover. 6. Replace any ozone resistant check valves on the air in or ozone gas outlet lines.

6.2 Corona Discharge Cell Servicing The Corona Discharge (CD) cell is an item that will require periodic maintenance. Electrical failure is usually the result of a mechanical failure. For example, should the cell become plugged with nitric byproducts or should water back into the cell, it could be the cause of an electrical failure. Proper air preparation can usually avoid the build-up of nitrous but may be cost prohibitive in some applications as the cost of a replacement cell is minimal. Refer to the diagrams at the end of this manual for the typical unit layout. Ozotech Inc. offers a CD cell cleaning kit for easy maintenance of your CD cells installed within your PCS PRO ozone generator. It is recommended to use this kit to thoroughly clean your CD cells every 6 months or sooner depending on operating conditions to ensure maximum ozone output. Having a spare CD cell already cleaned and dried on hand can save service time when performing this procedure. 7.0 Spare/Replacement Parts (*) Denotes recommended spare maintenance parts with initial purchase. Followed by quantity, per unit, recommended for one year's scheduled maintenance. Part # Description 33217-B Corona Discharge Cell 31500-2 Combo Board 47018-303/304 Kynar Check Valve (3/16 x1/4 ) *1 40080-01 Wall Transformer, 115 VAC to 12 VDC Regulated, 2A (Domestic Customers Only) 47044-1 CD Cell Maintenance Kit *1 8.0 Fusing There is one fuse per combo board connected to the 12 VDC source. They are located on the component side of each combo board. Fuse size and value is listed below: Part Number Fuse Size Fuse Value 43223 Type IEC 127.800 amp, fast blo 10

9.0 Troubleshooting Guide Symptom Unit does not turn on. Possible Cause Unit is not connected to power source, or is connected to improper power source. Remedy Refer to label on side of chassis for voltage/frequency requirements. Connect unit to proper power source. ON/OFF switch not turned to the HIGH/LOW position. Turn switch to HIGH/LOW position Blown fuse Replace fuse with equally rated substitute Unit keeps blowing fuses. Electrical short circuit. Visually inspect unit, and check for loose connections. Inspect printed circuit board for burn marks. Inspect HV wire from printed circuit board t o ozone cell f o r disconnection or burn marks. Repair all problems prior to placing unit in service, or contact factory for service information. Unit is yielding approximately ½ of rated output. Incorrect f use value and type are being used. Unit is connected to improper power source. Improper power source. Replace with appropriate size/type fuse. Refer to Spare/Replacement Parts for replacement part information. Refer to label on side of chassis for correct voltage requirements. Refer to label on the side of the unit to ensure that unit is plugged into proper voltage outlet. Unit turns on, but no ozone output Combo board is defective Replace combo board. Frequency driver high voltage lead (s) not connected to ozone cell(s). Water has been allowed to back up into the cell and cause a direct short. Cell is plugged with a build-up of nitrous byproducts and particulate matter. This is usually caused by the lack of proper air preparation. Connect lead(s) to Corona Discharge Cell(s). Refer to CD cell cleaning kit instructions. Refer to CD cell cleaning kit instructions. 11

10.0 Ozone Cell Replacement (Refer to Figure 3) 1. Disconnect unit from power source. 2. Remove Chassis Cover. 3. Disconnect the HV wire that is connected to the male spade lug on the printed circuit. 4. Disconnect all tubing from the cell(s). Pull the cell(s) out of the fuse clips and set aside. Reverse steps 1 thru 4 to install a new cell(s) 10.1 Illustrations Figure 3: PCS PRO component view Figure 4: PCS PRO typical use diagram 12