Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

Similar documents
Direct Gas-Fired Make-Up Air Models DG and DGX

Modular Supply Make-Up Air Unit

Indirect Gas-Fired Make-Up Air

Direct Gas-Fired Make-Up Air

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Energy Recovery with Cooling and Heating Model ERCH

Modular Heating & Ventilating Unit Model IGX-HV

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Make-Up Air Systems. Performance. Model DGK, DG, DGX

Make-Up Air March 2012

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Direct Fired Heater Model AD Specification

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Plenum Fans. Model HPA. Direct Drive

Energy Recovery with Cooling and Heating

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

FEATURES AND BENEFITS

Electric Duct Heaters. IDHB & IDHC Series

Gas-Fired Indoor and Outdoor Duct Furnaces

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

THE ULTIMATE ROOFTOP SOLUTION

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Energy Recovery Ventilators

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

GreenJet Transfer Fans

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

VariCool VAV Engineering Guide

The ultimate fresh air solution.

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

FCC Fan-Coil Units High-Performance, Vertical

RoofPak Applied Rooftop Systems

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

THE RIGHT SPEC. RIGHT NOW.

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

RT-OA TM Rooftop Outdoor-Air (DOAS)

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

62DA,DB,DC,DD,DE,DF07-38

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

GLOBAL FINISHING SOLUTIONS

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

MAC N-407 Air-Cooled Chiller

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SEQUENCE OF OPERATIONS

Reference Guide for Microprocessor Controller

Job Name Control Systems Description Date

Maverick II Commercial Rooftop Systems 15 to 75 tons

Chilled Water DOAS Fan Powered Terminal Units

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

SKYPAK II, 3 Ton Series, gives you a

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

VERTICAL FAN COIL UNITS

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

1.1 This section applies to air handling units for HVAC Systems.

MACH N-407 Heat Pump Air-Cooled Chiller

Addendum Downsville Pike Hagerstown MD April 29, 2016

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Air-Handling System Cooling Options

PRODUCT CATALOG BLOWER COILS.

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

ALL PRODUCTS BROCHURE

Submittal Data Performance Data Electrical Data

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Advance Release September 2009

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

48TM GAS HEATING/ELECTRIC COOLING UNITS

The H Series. Pure and Simple Solutions. HTLV Space Heating

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

RGE 13 A T - 1 A

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Flexible & Innovative. Cooling Solutions

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

XeteX, Inc. All Rights Reserved.

Transcription:

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX Kitchen and Industrial Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Packaged DX (3 to 16 tons), Split DX Cooling, Chilled Water or Evaporative Cooling September 2015

Direct Gas-Fired Overview Direct Gas-Fired Make-Up Air Units Greenheck s direct gas-fired make-up air units provide tempered outdoor air to a wide range of applications from kitchens to industrial facilities. Greenheck offers three model types with various levels of construction and control accessories for maximum flexibility and performance. Model DGK Model DG Model DGX Multiple fan and cabinet sizes provide airflow capacities up to 48,000 cfm and external static pressure capabilities up to 4.0 in. wg. All fans are tested in our accredited laboratory to ensure accurate fan performance. All units are factory-wired and tested prior to shipment. Each unit is checked for proper operation of the gas train, electrical components, and airflow. DG and DGK models shall be ETL Listed to ANSI Z83.4/CAN 3.7. DGX shall be ETL Listed to ANSI Z83.4/CSA 3.7-M99 (for non-recirculating) or ANSI Z83.18 (for recirculation). Direct Gas Technology Greenheck s direct gas technology uses direct gas-fired line burners with capacities up to 4,800,000 BTU/hr to provide efficient heating in any climate. A 92% thermal efficiency reduces gas consumption for maximum energy savings for both natural gas and propane fuel sources. Features High-quality cast aluminum burners with stainless steel mixing plates High turndown burner ratio (25:1) Benefits Provide superior resistance to corrosion for a long operating life Eliminates burner cycling at mild conditions Electronically modulating temperature control system Maintains precise discharge air temperature 2

Applications Kitchens Greenheck s Solution: A typical kitchen system has an exhaust fan that operates based on appliance usage. A Greenheck direct gas make-up air unit with integral heating and optional cooling is interlocked with an exhaust fan to deliver outside air to maintain a slight negative pressure in the kitchen relative to the adjacent dining space. The tempered supply air also conditions the outside air to increase employee comfort. Maximum Energy Savings: An optional variable air volume arrangement is available for reduced energy consumption during non-peak hours of operation. Easy Installation: The Greenheck combination package (model DG and DGX only) simplifies installation in kitchen ventilation applications. The pre-engineered combination extension ensures that the supply fan, exhaust fan, and curb all interface properly to reduce field labor costs. Equally important, Greenheck s combination packages are specifically designed to comply with the National Fire Protection Association (NFPA) code 96 which states: Exhaust duct must terminate at least 24 inches above the roof deck. Exhaust fan discharge must be at least 40 inches above the roof deck. Supply air intake must have a horizontal separation of 10 feet from the exhaust discharge. Note: Consult local codes and the authority having jurisdiction if there are questions concerning the use of this product. 10 ft. min. 24 in. min. 40 in. min. Industrial Model DGX Combination Package Greenheck s Solution: Greenheck s industrial make-up air units are designed to provide outdoor air for buildings with process or combustion exhaust. The introduction of tempered supply air prevents a building from pulling in unconditioned air. This decreases the energy required to condition the space. Flexible Designs: In addition to the constant volume 100% outdoor air arrangement, Greenheck s direct gas-fired make-up air products are also available with variable air volume or 80/20 recirculation to easily match supply air requirements as mechanical exhaust rates vary. Supply Fan: The DGX is available with either a forward-curved or direct drive backward-curved plenum supply fan arrangement. Forward-curved supply fans are very competitive for any price sensitive application and are typically suitable for applications requiring less than 2 in. wg of external static pressure. When incorporating a backward-curved plenum supply fan, the DGX model is capable of handling up to 4 in. wg of external static pressure. This includes a factory-mounted variable frequency drive providing an inherent soft-start for the supply fan. This flexibility in fan options also allows for five possible discharge arrangements, simplifying installations. These features make Greenheck s DGX model an outstanding option for a variety of new or retrofit applications. 3

Airflow Arrangement Variable Air Volume (VAV) - Models DG and DGX The VAV arrangement on models DG and DGX varies the fan speed based on building conditions to reduce costs associated with introducing ventilation air. The high turndown rate of the burner (25:1) and an airflow turndown capability of 50% provides consistent discharge temperature control as the supply airflow changes. All units selected with the VAV arrangement include: Factory-installed and programmed variable frequency drive (VFD) for adjusting the fan speed A patented burner bypass damper which maintains a consistent volume of air across the burner as supply airflow varies to ensure complete combustion. The bypass damper is self-adjusting for minimal maintenance and requires no controls. Airflow Control Strategies VFD with building static pressure control VFD with remote balancing potentiometer VFD controlled by a 2-10 VDC or 4-20 ma external signal VFD with two-speed operation controlled by a remote switch Kitchen energy management system controls. A remote or unit-mounted VFD provides seamless integration with Vari-Flow or Melink energy management systems. Outside Air Burner Bypass Damper Supply Air 80/20 Recirculation - Model DGX The 80/20 recirculation arrangement is recommended when the ventilation equipment provides the primary source of heating for the space. This is commonly found in large manufacturing or industrial facilities. All units selected with the recirculation option include: An integral filter section with outdoor air and mixing dampers. Up to 80% of the air from the space can be filtered and recirculated to combine with 20% outside air. The integral filter section includes built-in separation of outdoor and return airstreams to eliminate the possibility of contaminants from the recirculated air passing through the burner. Optional night setback sequences will allow the unit to satisfy the heating requirements of the space during unoccupied time periods. Airflow Control Strategies Modulating dampers with building static pressure control Modulating dampers with remote balancing potentiometer Modulating dampers controlled by a 2-10 VDC or 4-20 ma external signal Two position dampers controlled manually with a remote switch or time clock 20% 80-0% Outside Air (100-20%) Recirculated Air (0-80%) Supply Air 4

Controls Temperature Controls Discharge Temperature Control A factory-installed control allows the unit to discharge at a field-adjustable temperature by electronically modulating a gas valve. A room override thermostat is also available. Room Override Thermostat The room override thermostat works with the discharge temperature control option to temporarily increase the discharge temperature if the room drops below space set point. The room sensor may be wall/beam mounted or included on a remote control panel. Space Control This control allows the user to select a space temperature set point. The unit will then adjust the discharge temperature to achieve the desired space temperature set point. The room sensor may be wall/beam mounted or included on a remote control panel. External Control This control allows a field supplied 2-10 VDC signal, a 4-20 ma signal, or Building Management System command to control the modulation of the burner. Greenheck includes field-adjustable minimum and maximum settings to prevent over and underfiring the burner. Unit Controls Remote Panel - Greenheck offers two types of remote control panels featuring a variety of switches, thermostats, temperature selectors and indicator lights. Installation and field wiring is easy by using a numbered terminal strip for point-to-point wiring between the make-up air unit and the remote panel. Industrial/Severe Duty: The industrial panel features a variety of switches and indicator lights mounted on a Permatector coated steel box in a NEMA-1 enclosure. The severe duty panel offers a variety of indicator lights and switches mounted in/on a stainless steel panel satisfying the following NEMA enclosure requirements: 3, 3R, 4, 4X, 12. Optional Control Features: Night Set-Back with 7-day time-clock: Timers are available to set the unit to energy saving mode during unoccupied hours. Kitchen (KSCP): Features light toggle switches for kitchen hood lights, fans and tempering. A stainless steel faceplate for flush wall mounting and a junction box is included. Network Interface Controller - An optimum solution for connecting a make-up air unit to a Building Management System (BMS). The network interface controller offers an easy-to-use, remote-mounted display. It easily integrates to BACnet IP, BACnet MSTP, Lonworks or Modbus. Two operating options are available: Monitor only: Allows the BMS to monitor the status and functions of the unit through a factory-installed controller. Control commands will be provided by terminal style signals external to the unit. Monitor and Control: Allows the BMS to monitor the status and command the basic functions of the unit through a factory-installed controller. A remote panel is not available with this option. 5

Cooling Options Cooling Coils - Model DGX Both chilled water and direct expansion coils for split systems are available. The cooling section includes the cooling coil, double-pitched stainless steel drain pan sloped in opposite directions for positive draining, and insulated double-wall construction. Drain and coil connections are stubbed through the wall for convenience. Chilled Water Coils: Available from two to six rows and various circuiting configurations to meet various load conditions. Airflow ranges up to 11,700 cfm in both water and glycol applications. Coil performance shall be calculated in accordance with AHRI 410. Evaporative Cooling - Models DG and DGX The optional evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling frame around the media. CELdek and GLASdek evaporative cooling media are available with a depth of 12 inches for a 90% cooling effectiveness. 6 Direct Expansion (DX) Coils: DX coils for use in split systems are available from two to six rows. Circuiting options include single, face-split, and interlaced arrangements. Coil performance shall be calculated in accordance with AHRI 410. All cooling coils can be coated with an ElectroFin coil coating upon request! *The entire section mounts directly to the front of the unit eliminating transition or ductwork by others. Drain and overflow are conveniently tapped through the side of the cooling section. The supply line connection is field located where convenient. Freeze protection and automatic drain and fill evaporative optimizer are also available. Airflow capacity for evaporative cooling is up to 46,000 cfm. The evaporative cooling section for units above 9,000 cfm ship separately. *Recommended for exterior installation only. Control Options: Recirculating Pump: Includes a pump that recirculates water over the evaporative media and is activated by a call for cooling. A field-adjustable bleed-off valve keeps mineral concentrations low. Auto Drain and Flush: Includes a recirculating pump and a field-adjustable timer that will periodically flush the sump to minimize mineral build-up. Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in 1-3-5-10-15- or 25 day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download at no charge lightweight, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com

Cooling Options Packaged Direct Expansion - Model DGX Providing unconditioned make-up air through ceiling diffusers or perforated kitchen hood plenums can create an uncomfortable work environment during summer months in commercial kitchens. Although conditioned make-up air can increase comfort levels, the need to cool and dehumidify this air to a 55 F supply air temperature can be detrimental to the food preparation process, significantly increase equipment first cost, and annual energy cost. The packaged DX cooling option for the DGX model is specifically designed for kitchen applications. Airflow Arrangement - Optional Variable Air Volume or Constant Volume 100% Outdoor Air Performance Range - 1,000 to 7,500 cfm Cooling Capacity - 3 to 16 Nominal Cooling Tons The packaged DX cooling option for the DGX model is designed to cool the kitchen make-up air to a 70-75 F supply air condition to improve space comfort and enhance employee productivity at an economical first cost. Features Draw-thru cooling arrangement Standard high and low pressure cutouts and crank case heaters Low discharge temperature cutout Benefits Even airflow across coils for efficient cooling operation and less chance of water carryover Increased compressor life Prevents coils from freezing 1 Efficient, direct drive condenser fans statically and dynamically balanced. 1 2 3 4 2 Condenser and evaporator coils with copper tubes mechanically expanded in aluminum fins. Evaporator coils mounted on a stainless steel drain pan. 3 Thermal expansion valves provide refrigerant control. 4 Quiet-running, hermetic scroll-type compressors are mounted in an isolated compartment to be serviceable without affecting airflow. Mounted on neoprene isolators to minimize vibration transmission and noise. 7

DGX Standard and Optional Features 1 S Standard Feature O Optional Feature Construction Constructed of heavy-gauge G90 galvanized steel Single or double-wall construction with 1-inch fiberglass insulation Removable access panels with optional hinged doors Available finishes include: - Permatector (1,800 hr/salt spray rating under ASTM B117 testing conditions) - Hi-Pro Polyester (4,000 hr/salt spray rating under ASTM B117 testing conditions) - Baked Enamel coatings available in 16 standard colors or custom color match 1 5 Direct Gas-Fired System High-quality cast aluminum burners with stainless steel mixing plates 25:1 turn down ratio Electronic modulation burner control Flame safeguard with optional digital fault indicator - available on pilot ignition systems only FM Global gas train configurations available above 400,000 BTU/hr High/low gas pressure switches automatically shuts down the burner if the manifold pressure/inlet gas pressure is too high/low for the burner to operate properly 2 Weatherhood Weatherhood with birdscreen features a wire mesh intake, preventing large debris from damaging the filters. An additional filter section is required. Aluminum mesh filtered weatherhood eliminates the need for an additional filter section Louvered weatherhood includes a drainable blade louver at intake with 2-inch aluminum mesh filters The thru-wall sleeve provides an attachment interface between the weatherhood and burner section. The sleeve accommodates walls up to 15 inches (38 cm) in depth 2 3 4 5 6 3 4 Filter Section V-bank filter section or mixing box 2-inch washable aluminum mesh 2-inch MERV 8 pleated disposable 2-inch MERV 13 pleated disposable 4-inch MERV 14 pleated disposable 2-inch MERV 8 and 2-inch MERV 13 pleated disposable 2-inch MERV 8 and 4-inch MERV 14 pleated disposable Dampers Low-leakage non-insulated inlet damper with factory-mounted and wired actuators Low-leakage insulated or non-insulated outlet damper 6 Control Center 24 volt control voltage Magnetic motor starter with solid state overload protection Control transformer Disconnect switch Distribution terminal strip UL Listed, Recognized, or Classified electrical components Factory prewired for single point power connection 8

7 7 8 9 Cooling Options All cooling options include a stainless steel drain pan Evaporative cooler Chilled water coils Split DX coil (coils only) Packaged direct expansion (PDX) Includes condensing fans and coils. Only available on forward-curved fan supply models. Supply Fan Options Forward-curved fan with optional factory-provided VFD Direct drive backward-curved plenum fan with factory-provided VFD (shown) Balanced wheels to ensure a vibration- free operation 8 9 Vibration Isolators The entire fan and motor assembly is mounted on vibration isolators to minimize noise transmission into the building. Neoprene or spring isolators are available on forward-curved supply fan models. Backward-curved supply fan models only offer neoprene isolators. Optional Electrical Controls Auxiliary Contacts Normally open and normally closed contacts are available for supply fan status and supply fan interlocks. Coil Freeze Protection Adjustable temperature sensing capillary tube which will disable the fan motor at 35ºF. This freeze protection is NOT a substitute for draining of water-filled coils. Cooling Relay When interlocked with a rooftop unit (RTU), this relay can be used to lockout a call for heat from the make-up air unit when there is a simultaneous call for cooling from the RTU. CO 2 Sensor Shipped loose for field-mounting and wiring in the supply or return air duct. Dirty Filter Sensor Monitors the pressure drop across the filter section. If the pressure drop is higher than the field-adjustable setting, the switch will trip and indicate that the filters need to be cleaned or replaced. An indicator light may be wall/ beam mounted or provided with a remote panel. Exhaust Fan Starter(s) Factory-mounted and wired for an electrical interlock between the supply and exhaust fan(s). Fire Stat Type III Shipped loose for field mounting and wiring in the supply or return air duct. Contains two normally open and two normally closed contacts for alarm notification. Flame Safeguard Display Interfaces with the flame safeguard. It displays a detailed history of the faults that have occurred as well as the current status of the MUA unit. The display is detachable and can be used on multiple units. MUA must have pilot ignition for this option to be valid. Freeze Protection Automatically shuts down the supply fan when the discharge temperature is below the set point for an extended amount of time. This prevents the unit from discharging nontempered air into the building and freezing pipes and other temperature sensitive items. Heating Inlet Air Sensor Automatically turns the heat on and off based on a field-adjustable set point. Inlet Damper End Switch Will not allow starter to engage until end switch is proved, ensuring that the inlet damper is fully open before unit operation. Service Receptacle A 115 volt GFCI outlet can be shipped loose or mounted externally in a NEMA-3R box for the convenience of service personnel. A separate 115 volt power source is required. 9

Model Comparison Model Number Code The model number code is designed to completely identify the unit. The correct code letters must be specified to designate the configurations and size. *If no P is shown, then a forward-curved fan is provided. Model DGK - Economy Model Parent DGK, DG, DGX Model DGK is designed to be the most economical, compact, and simple approach to constant volume 100% outdoor air kitchen applications. The DGK is perfect for budget-sensitive kitchen applications that require heated make-up air. Airflow Arrangement - Constant Volume 100% Outdoor Air Performance Range - 1,000 to 8,500 cfm Heating Capacity - Up to 800,000 BTU/hr DGX - P1 2 0 - H32 Optional Fan *P - Backward-Curved Plenum Housing Size 10-42 Wheel Diameter (in.) 8-36 Fan Quantity 1 Model DG - Standard Model DG sets the standard for an efficient approach to tempered make-up air applications. Several intake and filtering configurations and optional evaporative cooling is available. The variable volume arrangement provides seamless integration with Vari-Flow and Melink kitchen energy management systems. Airflow Arrangement - Constant Volume 100% Outdoor Air and Variable Air Volume Performance Range - 800 to 15,000 cfm Heating Capacity - Up to 1,600,000 BTU/hr Cooling Capacity - Evaporative cooling up to 12,000 cfm Model DGX - Configurable Model DGX is a highly configurable direct gas-fired heating and cooling system that incorporates a modular design for maximum flexibility. Provides make-up air across a broad range of applications with expanded heating, cooling, and airflow capacities. Airflow Arrangement - Constant Volume 100% Outdoor Air, Variable Air Volume and Recirculation (80/20) Performance Range - 800 to 48,000 cfm Heating Capacity - Up to 4,800,000 BTU/hr Cooling Capacity - Evaporative cooling up to 48,000 cfm - Chilled water cooling up to 11,700 cfm - Split DX cooling up to 11,700 cfm - Packaged DX cooling up to 7,500 cfm 10

Option Comparison DGK DG DGX Intake Options Birdscreen Weatherhood Optional Optional Aluminum Mesh Filtered Weatherhood Standard Optional Optional Louvered Weatherhood Optional Optional Thru-Wall Weatherhood Optional Airflow Arrangement Constant Volume 100% Outdoor Air Standard Optional Optional 80/20 Recirculation Optional Variable Air Volume Optional Optional Supply Fan Options Forward-Curved Standard Standard Optional Backward-Curved Plenum Optional Temperature Controls Discharge Temperature Control Standard Optional Optional Discharge Temperature Control with Room Override Optional Optional Discharge Temperature Control by External DDC Signal Optional Unit Controls BMS Interface Optional Remote Panel Optional Optional Optional Cooling Options Evaporative Optional Optional Direct Expansion (DX) Optional Packaged Direct Expansion (PDX) Optional Chilled Water Optional Discharge Options Top Discharge Optional Bottom Discharge Optional Optional Optional Left or Right Discharge Optional End Discharge Optional Optional Optional Combination Package Optional Optional Options & Accessories V-Bank Filter Section Optional Optional Outdoor Air Dampers Optional Optional Optional Discharge Dampers Optional Optional Duct Liner Insulation Standard Optional Optional Double-Wall Construction Optional Optional Exhaust Fan Starter(s) Optional Optional Dirty Filter Sensor Optional Optional Freeze Protection Optional Optional Inlet Air Sensor Heat Standard Optional Optional Variable Frequency Drive (VFD) Optional Optional Service Receptacle Optional Auxiliary Contacts Optional Optional Gas Pressure Regulator Optional Optional Optional Special Coatings Optional Optional Optional Roof Curbs Optional Optional Optional Duct Adapter Optional Optional Optional 11

Intake and Discharge Options Weatherhoods Birdscreen DG & DGX only Aluminum Mesh Filtered Louvered DG & DGX only Thru-Wall DGX only Filters V-Bank DG & DGX only 80/20 Recirculation DGX only Supply Fan Options Forward-Curved Backward-Curved Discharge Options Top or Bottom Discharge Left or Right Discharge (only available on backwardcurved fan option) End Discharge 12

Dimensional Data & Weights Model DGX-H12 DGX-H22 DGX-H32 DGX-H35 DGX-H38 DGX-H42 Airflow Range (cfm) 800-3,000 2,600-6,500 6,500-15,000 15,000-23,000 24,000-34,000 32,000-48,000 Approximate Weight* (lbs) 700 1,100 1,500 2,300 3,000 4,000 Unit Height (in.) 39 44.9 48.7 54.6 63.9 67.9 Width (in.) 33.7 44.1 53.1 78.5 95.5 100.3 Overall Width with Evaporative Cooling (in.) 33.7 >4,800 cfm = 60.6 Lengths (in.) 9,000 cfm = 66.5 >9,000 cfm = 96.5 120.5 95.5 100.3 Birdscreen Weatherhood 29.9 45.6 47.3 47.1 60.9 70.0 Module 1 Module 2 Aluminum Mesh Filtered Weatherhood 31.5 47.1 48.7 47.8 65.3 68.9 Louvered Weatherhood 13.8 16.9 16.9 - - - Thru-Wall 69.9 82.3 104.7 120.6 - - Evaporative Cooling 30.2 30.2 9,000 cfm = 34.7 >9,000 cfm = 38.1 38.1 98.5 116.5 V-Bank Filter Section 21.5 24.1 25.8 27.7 30.8 31.1 80/20 Filter Section - 44.1 50.2 51.3 50 55 Module 3 Module 4 Module 5 Cooling Coil (standard) 30 30 - - - - Cooling Coil (high capacity) 50.4 69.4 98.1 - - - Burner 37.6 52.3 52.5 54.9 58.1 58.1 Forward-Curved Fan 42.5 52.2 65.9 62 71.5 75.5 Backward-Curved Fan 25.1 32.2 51.0 *Weight based on DGX with optional birdscreen weatherhood, V-bank filter section and forward-curved downblast fan discharge. Typical DGX Configuration Module1 Module 2 Module 3 Module 4 Module 5 Weatherhood with Birdscreen V-Bank Filters Cooling Coil Burner Fan 13

Dimensional Data & Weights Model DG Stand-Alone A B C D Model Aluminum Mesh A Louvered Birdscreen B C D Width Approximate Weight Airflow Range (CFM) DG-H10 31.8 27.5 26.2 27.8 78.3 33.8 28 600 800-3,000 DG-H20 34.8 30.3 32.2 30.3 86.3 33.8 37 700 2,600-6,500 DG-H30 65.3 33.3 28.1 33 101.8 42.5 48 1,100 6,500-15,000 All dimensions are shown in inches. All weights are shown in pounds and includes birdscreen weatherhood and 2-inch filter section. Model DG with Combination Package A max. 10 ft. min. 40 in. min. 24 in. min. Model A Width Approximate Weight DG-H10 185.7 35.5 900 DG-H20 204.8 50 1,200 DG-H30 227.0 58.8 1,700 All dimensions are shown in inches and based on largest available CUBE exhaust fan. All weights are shown in pounds and includes birdscreen weatherhood, 2-inch filter section, curb, fan pack extension and equipment support. 14

Dimensional Data & Weights Model DGK A B C Model A B C Width Approximate Weight Airflow Range (CFM) DGK-H15 30.9 76.5 29.8 31.4 500 1,000-4,500 DGK-H25 48 88 39 49.5 1,000 4,000-8,500 All dimensions are shown in inches. All weights are shown in pounds and includes filtered weatherhood. Model DGX with Packaged DX Cooling C D B A E Model Nominal Tons Dimensions Approximate A B C D E Weight DGX-H12 3, 5, 6, 7 156 33.8 25.5 70 39 1,500 DGX-H22 7, 9, 10 212 45 32 87 45 2,200 DGX-H32 10, 12, 16 237 52 35.5 99 49 2,800 All dimensions are shown in inches. All weights are shown in pounds and includes filtered weatherhood and packaged DX cooling. 15

Additional Make-Up Air Products Indirect Gas - Economy Model IGK Modular Supply Model MSX Indirect Gas - Standard Model IG Direct Gas - Industrial Model TSU Indirect Gas - Configurable Model IGX Direct Gas - Vertical Model VSU Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Greenheck P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com Prepared to Support Green Building Efforts Copyright 2015 Greenheck Fan Corp. 00.TAP.1016 R3 9-2015 IW