Reduce Energy Costs with Vapor Degreasing. Mike Jones MicroCare Corp., New Britain, CT

Similar documents
Airless Vacuum Cleaning Systems

All Cleaning Options for Parts Cleaning

Selecting Cleaning Processes for Electronics Defluxing: Total Cost of Ownership

SOLVENT CLEANING OPERATION EQUIPMENT SUMMARY FORM-44 Page 1 of 7

Optimizing Strategy for Boiler Drum Level Control

Aqueous Cleaning Design Considerations --us-

Serec Corporation. American owned company located in Rhode Island, with a 30,000 square foot facility.

THERMAL ICE STORAGE: Application & Design Guide

vapic was the first company in the industry to use screw vacuum pumps. We have gained extensive

PARTS CLEANING AND DEGREASING

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Brewmaster Edition Chronical Fermenter 1 Barrel Supplemental Report

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Hot-dip galvanising lines use cold rolled steel strip

ADVANCE VAPOR DEGREASING OF HIGH RELIABILITY PRINTED CIRCUIT BOARD ASSEMBLIES BY Richard D. Jackson

State of New Jersey. General Permit. for Degreasing Operations using Non-HAP Volatile Organic Compounds (VOCs)

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Operational Costs of Evaporation vs. Rinse Water Recycling. Data compiled by Tim Noble

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Trim Pump Impellers. Fredrick/Weinman Engineered Products 2-1/2 KH, 2-1/2 x 3 x 12

BHC. Replacing Air Sparging Agitation Increases Cleaning Efficiency in Immersion/Soak Tank Degreasing BHC WHITE PAPER

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Fundamental Principles of Air Conditioners for Information Technology

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Water Efficiency. Industry Specific Processes. Metal Finishing. for Commercial, Industrial and Institutional Facilities

Cleaning Today s Assemblies in Batch Systems

PERFECT HEATING, COOLING, AND VENTILATION

Opteon Vertrel. Specialty Fluids by The Chemours Company. Innovative Fluids That Deliver Superior Performance

Theory of Operation: How Parts Cleaning Works

CO 2 EVAPORATOR DESIGN

Understanding of Surface Heat Tracing of Bulk Storage Tanks for Viscous and High Pour Point Fluids - By, H. R. Mullan

SOLO MIDI AVD DUO HIGH PERFORMANCE AQUEOUS COMPONENT CLEANING EXPERTS IN COMPONENT CLEANING PROCESS, CHEMISTRY & TECHNOLOGY

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

Appendix A. Glossary of Common Terms

Cost, time and water savings gained through optimized tank cleaning

Refrigeration Systems and Accessories

Hybrid Drying Technology for In-line Aqueous Cleaning of Lead-Free Assemblies

PACKAGED REFRIGERATION EQUIPMENT

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

obtained frm- implementation of alternative, cost-effective cleaning technologies.

Harris & Bruno Accessories. for

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

INDUSTRIAL DEHUMIDIFICATION DRYING OF SOFTWOODS

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

Sustainable Techniques in Refrigerated Space

Solar Hot Water. PV + Heat Pump or Thermal. Which is better?

Steam: Yesterday, Today and Tomorrow The Use of Steam as an Efficient Heat Source

WATERLIFE VACUUM VACUUM CLEANING SYSTEM FOR MODIFIED ALCOHOL

Novel Press Fabric Cleaning Method Increases Productivity in a Sustainable Manner

LUCKILY THERE S A BETTER WAY

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Energy Recovery Ventilation

Technology Bulletin. Granulators and Shredders Have More. By Vincent Carpentieri, Size Reduction Sales Manager, The Conair Group

Vacuum Booster for Distillation Process

Calculating the True Cost of Cleaning

KOCH Curtain Coaters

MVR Evaporators Reduce Plant Operation Costs

gforce Ultra CRAC Equipment: Using the Latest Variable Capacity Technology to Lower Energy Usage & Increase Reliability

Time and water efficiency in tank cleaning

The Digital Scroll Dryer

Ammonia. Background on ammonia as a refrigerant

TESTS OF ADSIL COATING

KE2 EvaporatorEfficiency Theory of Operation

Challenges and Methods of Estimating a Conceptual HVAC Design

Chapter 9. Refrigeration and Liquefaction

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

High precision cleaning system. High precision cleaning system. PRECI Co., Ltd. Headquarters and Tokyo office. Contact for inquiries

All rights for changes reserved that lead to technical improvement. kolb GmbH 2017

$42,000. Danfoss Turbocor Compressors Give INTERTECH PLASTICS A RESHORING ADVANTAGE. saved annually

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

c o n d e n s e r Glossary of Terms

System Design, Commissioning, Operation

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Keeping Chillers Efficient - Archives - Energy and Power Management

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Transcritical CO2 Bottle Cooler Development

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

ABSTRACT. 2 CanmetENERGY

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Gas-Fired Double-Effect Chiller-Heater

Rotary Impingement Tank Cleaning Equals Significant Water and Cost Savings

INK CURING TIPS TIPS & TECHNIQUES

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

Understanding Process Vacuum for Process Improvement

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

LESSON CLUSTER 9 Explaining Condensation and the Water Cycle

A Treatise on Liquid Subcooling

POST-CLEANING PROCESSES. Precision Drying Completes Precision Cleaning BY DANIEL J. VANDERPYL AND KIRK MCGLOTHLAN

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

NEW HARRIS TEETER STORE SHOWCASES FIRST HILL PHOENIX SECOND NATURE COMPACT CHILLER UNITS IN NORTH AMERICA

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

TWO- AND THREE-STAGE CASCADE REFRIGERATION SYSTEM By: Paul B. Reed

THERMAL SYSTEMS AND PROCESS EQUIPMENT FOR THE FOOD AND BEVERAGE CAN INDUSTRY

The analysis proceeded by adopting the ASHRAE guideline for conventional HVAC chiller applications. This guideline is summarized in Table II.

R-407A R-448A R-449A

Advancement In Coating Curing On Railcars

Transcription:

Reduce Energy Costs with Vapor Degreasing Mike Jones MicroCare Corp., New Britain, CT In the product finishing world, there are four common precision cleaning processes: hydrocarbon, aqueous, semi-aqueous, and vapor degreasing. Each choice has its strengths and its disadvantages, but one of the biggest problems with aqueous and semi-aqueous cleaning is the quantity of the electricity it takes to operate those systems. Let s face it: all energy costs are rising and electricity is no exception. On a historical basis, electricity already is expensive and getting more so. Capacity is another issue: the recent cold winter in Texas generated an energy crisis there and rolling black outs were inflicted on companies due to lack of sufficient generating capacity at the time. Additionally, the production of electricity by burning hydrocarbon fuels is a key contributor to global warming. Vapor degreasing can dramatically reduce a company s energy budget devoted to cleaning processes. SOLVENT CHEMISTRIES It has only been in the past decade or so that leading companies have commercialized new, environmentally-acceptable cleaning solvents suitable for vapor degreasing. This means that the speed, convenience and energy savings of this proven technology now is available to engineers everywhere. Unlike aqueous or hydrocarbon cleaning, vapor degreasing requires special fluids with a unique combination of characteristics. Ideally, these cleaners should be nonflammable, immiscible with water, have a low boiling point, an appropriate Kari-Butanol (Kb) value, a high density, low surface tension, low viscosity, a low specific heat and a low latent heat of vaporization. Developing fluids with all of these characteristics has not been easy for DuPont, 3M, and the other suppliers. Four of these characteristics affect cleaning performance. The high density, the low surface tension and low viscosity all ensure the solvent will wet every surface, getting into (and out of) tiny nooks and apertures. As the old adage goes, if you can t wet you can t clean. The Kb value measures the strength of the fluid, and ensures the solvent will have the muscle to deliver dissolve any contamination. So far, so good.

But it is the low specific heat and a low latent heat of vaporization that are the primary reasons a vapor degreaser is significantly more energy-efficient than other technologies. The energy inefficiency of water cleaning stems right from the chemical properties of water itself. The inherent characteristics of water make it very difficult to use and to remove water efficiently from complex surfaces. By comparison, solvent cleaning is highly energy-efficient. The term specific heat defines the amount of heat required to raise the temperature of a unit mass by one degree Celsius. The specific heat of water is very high, which is why oceans have such a very important role stabilizing global temperatures: it takes a lot of energy to heat or cool water. As an example, the specific heat for water is 4.186 joule/gram C, which is four times higher than modern solvents such as npb or the popular DuPont HFC cleaning chemistries. After cleaning, most cleaning systems evaporate the cleaning fluid from the surface of the parts. Once a liquid begins to change phase that is, change from a liquid into vapor specific heat is no longer used. The proper statistic to measure the energy required to evaporate a fluid is the latent heat of vaporization. And therein lies the rub: it takes a great deal of energy to evaporate water. Specifically, water requires 970.4 BTU of energy to vaporize one pound of liquid. In contrast, npb requires only 58.8 BTU for an equal weight, and the popular DuPont HFC solvents require only 67.1 BTU/pound. This means it will take roughly 14 times more electricity to evaporate a pound of water than to vaporize a pound of solvent. AQUEOUS CLEANING ENERGY CONSUMPTION Most aqueous cleaners are horizontal designs which use hoists or conveyors to move the parts through a series of dip tanks. A typical aqueous batch system has one wash tank and between two to five reverse-flow, cascading rinse tanks that require 2-5 gallons/minute of deionized water. These systems typically will be 50-150% larger than vapor degreasers of the same capacity, simply because of the need for more tanks, larger pumps, blowers, filters and so on. Typically these machines use about 8-10 kw of electricity per hour of operation. Most aqueous cleaning systems have three or more tanks with ultrasonics, adding another 1-2 kw of energy consumption. Aqueous system cleaning cycles tend to run longer than vapor degreasers. Cleaning cycles of 20-40 minutes are not uncommon. Most vapor degreasers clean in 5-12 minute cycles, reducing energy costs and work in process inventory.

Removing excess water from parts is challenging because of the chemical nature of water discussed above. Evaporating the excess water with heat is relatively slow and expensive, so the most common drying option is an air knife. A typical aqueous system easily can use 5 kwh at the drying stations, and that number could double on a bigger machine simply because of the increasing size of the motors, fans and compressors. Ultimately, for final drying, heated air knives often are necessary which simply compounds the energy consumption problem. Water pre-treatment and post-treatment systems also use large quantities of electricity. Once the water is deionized, the water is usually heated to 140-160 F for the cleaning process which requires at least 2-3kW of power or more for the pumps and support equipment. On the back-end, assuming the system needs to process five gallons of waste water a minute, even the most frugal waste water system is going to need 3-5 kw of power. One last consideration is the stand-by power draw. At many companies the aqueous cleaners never are shut down because of the cost and the delay in reheating. These systems will use 2-5 kw of electricity at a minimum, hour after hour, even when no cleaning operations are being conducted. Here s a detailed example: A Branson 1620 aqueous system with modest cleaning capacity costs around $85,000. It has four sumps and is almost 15 feet long, twice as large as an equivalent vapor degreaser. It uses 17kW during startup and 12kW during use, plus whatever ultrasonics, operating at 140 F. The total system will use approximately 25 kilowatts per hour. Aqueous cleaning machines also add heat to the surrounding environment which increases the load on the air conditioning system. The Branson 1620 will add nearly 300,000 BTU/hour of heat to the room in which it is operating plus approximately 15 pounds of water (roughly two gallons) into the air of the plant every hour, which will need to be removed by the HVAC system. Vapor degreasers, with the new low-temperature solvents, make only a minimal contribution in this manner. DOING THE NUMBERS It s clear that the fundamental chemical characteristics of water make it inevitable that aqueous cleaning will consume far more kilowatts to clean as the systems need to purify the water, clean the parts, dry the parts and then re-treat the water after cleaning. In contrast, some small vapor degreasers operate on 120v power supplies. A general rule-of-thumb is that any aqueous cleaning system will use ten times the energy of a vapor degreaser of comparable capacity. Another estimate calculated using the specs from two cleaning machines suggests that a small

facility will save a minimum of $300/month in direct energy costs by switching to vapor degreasing. As substantial as those numbers are, many companies find the cost savings to be even greater. One company in the Midwest was a long-term aqueous user. It was able to document such massive savings by switching to vapor cleaning the local electrical utility provided a grant that funded 100% of the purchase of the new cleaning hardware. But that s just the beginning. Other savings, from faster throughput to higher yields and fewer defects all contribute to ever greater profitability. With energy costs rising and the availability of adequate water supplies becoming a global concern, it makes sense to give energy-efficient solvent cleaning another look. Mike Jones is the Vice President of MicroCare Corp., a US-based specialty firm dealing with precision cleaning, coating and lubrication. He thanks John Hoffman for his assistance preparing this article. SIDEBAR: VAPOR DEGREASING CONCEPTS Many younger engineers today have never seen a vapor degreaser, so it is worthwhile to review this closed-loop technology. Figure 1 illustrates the manner in which a vapor degreaser operates. The solvent is loaded in the boil sump (lower left chamber in Fig. 1) where the solvent is heated to its boiling point, usually 100-170º F, depending upon the solvent. As will any boiling liquid, the boiling solvent produces steam in the form of a clear, dense vapor that rises into the machine. Eventually the vapors rise up and reach the primary condensing coils. These coils chill the solvent vapors and condense them back into the liquid state. This liquid falls into a trough around the interior circumference of the machine. There it is routed through a water separator and directed back into the rinse sump. Since the rinse sump already is filled with clean solvent, the addition of clean, newly distilled solvent causes the sump to overflow into the boil sump, completing the distillation cycle.

Images

Degreaser.Balloon.Vapor Layer.21.jpg: In a vapor degreaser, the invisible vapors of the cleaning fluid are heavier than air and are trapped inside the machine. In this photo, a balloon has been placed inside the system and is resting on top of the entrapped vapors. As the warm vapors touch the cooler balloon, the vapors condense back into liquid form and are dripping off the bottom of the balloon. The faint line around the equator of the balloon is the air-vapor boundary. Degreaser.Condensing Coils.02.JPG: The primary condensing coils are the heart of the vapor degreaser. These chillers serve two functions: they define the maximum height of the vapor layer, which in turn defines the maximum size of the parts that can be cleaned in the machine, and they condense the vapors back into liquid for recycling into the rinse sump. Since recycling the solvent is an integral part of the vapor degreasing technology, the solvent can be used hundreds of times and never wears out. This makes vapor degreasing very inexpensive.

Lab10.Dupont Vapor Degreaser in Lab.jpg: In a normal cleaning cycle, the boards or parts are placed in a basket and lowered into the cleaning fluids. The boiling fluid churns and this provides sufficient agitation for normal cleaning processes. In this demo system, solvent sprays and ultrasonics are used to deliver even higher levels of cleaning performance

Degreaser.Hoist.39: Vapor degreasing is very inexpensive as long as solvent losses are controlled. Many companies decide to upgrade to more complex cleaning systems because they include features and capabilities which reduce solvent losses and therefore

keep life-cycle costs at a minimum. One important feature perhaps THE most important feature is an automated hoist which inserts and removes the parts from the cleaning system. Automated hoists have been proven to dramatically reduce solvent losses.