The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

Similar documents
The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

Wireless Thermocouple Sensor

Wireless Duct Temperature Sensor

Wireless DC Voltage Detector

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

Wireless 0-5 Volt Meter Sensor

Wireless Light Detection Sensor

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Smart Monitoring Systems. for Property Management SMART SOLUTIONS. Property Management DOORS & WINDOWS TEMPERATURES LIGHTS CARBON MONOXIDE

Frequently Asked Questions

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Photoelectric Beam Detector

HOBO U30 Remote Monitoring Systems

REMOTE MONITORING AND ALARM SYSTEM

Smart Wireless Sensor

Architectural and Engineering Specification for a. Flash / Flare

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

Ion Gateway Cellular Gateway and Wireless Sensors

Selecting an Electrical Enclosure

Smart Wireless Sensor

Operation and Maintenance Manual

Quick Touch Pendant User Guide

Model OEM-2 INSTRUCTIONS FOR USE

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Essential Insight.mesh Wireless System,

WAVE SEQUENCER DELIVERS:

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Architectural and Engineering Specification for a Real-Time Locating System Flare

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

Monnit Wireless Local Alert. User s Guide

ALTAIR 5X Multigas Detector

Quick Touch Pendant. Quick Touch Pendant. Battery

SAFESITE Multi-Threat Detection System

Ross SysCon Control Panels

wireless. web-based. worthy of the name RACO.

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

ALTAIR 5X Multigas Detector Product Specification

portable gas analyser

Q3200 Smart Home Alarm. Kit Content and Installation Guide

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

TotalPac X Single interlock SUREFIRE system

Industrial Grade Gas Detection

Section PERIMETER SECURITY SYSTEMS

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Smart Security, Always Connected

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Industrial Grade Gas Detection

K100A Insertion Probe Thermometer

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

TotalPac X Firecycle III Preaction Double interlock system

environmental chambers for Battery testing

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Toxic Gas Detection. Model F12. Toxic Gas Detection

ENCLOSURE COOLING. Glossary

Custom Duct Heaters. Special Applications

Manage Alert Rules & Teams

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

EWR2 WIRELESS SIGNAL REPEATER

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

Fiber Optic Cable Fence Disturbance Sensor

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

SOMETHING IS WRONG? Countless industries depend on Sensaphone for the most comprehensive remote monitoring systems available.

Model 784 Remote Power Supply

Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide

FLOOD SERIES DATA SHEET

HOW TO SPECIFY A DELPHIAN SYSTEM

RAPID Alert System User Guide. RAPID Alert System. User Guide

GLD-30 Gas Leak Detector

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Panel XTO210/610/710 GPRS

Mobeye CM2410 GSM fire alarm communicator

The PBE Group. Industries We Serve. PBE Catalogue

BSC-50 ADU-500. Autonomous RTUs

Soon. CELL682 Wireless Alarms WSG30. NEW for. Coming

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

STRIKE GUARD DELIVERS:

Fitting instructions

Custom Duct Heaters. Special Applications

Hugs Product Guide Specification

CONTROL YOUR HOME FROM EVERYWHERE

portable gas analyser

Alarm System. Enjoy the Security. Enjoy Simple Life KERUI Doorbell. Security and Protection. Leading Brand of Intelligent. Present by Secrui Group

ia5 instruction manual

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

Transcription:

by The Leading Enterprise Internet of Things Solution THERMOCOUPLE Wireless Thermocouple Sensors General Description The ALTA Wireless Thermocouple Sensor is available with a hardwired thermocouple or K-type connector to support various thermocouple types and ranges. The hardwired thermocouple option measures temperatures up to 400 C (752 F). Hardwired version measures temperatures up to 400 C (752 F) Pigtail version supports standard K-type thermocouples Principle of Operation The ALTA Wireless Thermocouple is available with either a hardwired thermocouple or a K-Type connector (for supporting various thermocouple types and ranges) to measure high temperature applications. It is programmed to sleep for a user-given time interval (heartbeat) and then wakeup, send power to the thermocouple and wait for it to stabilize, and convert the analog data, mathematically compute the temperature and transmit the data to the gateway. To stay within the abilities of the processor, the temperature is computed off a data table provided by the manufacturer. Example Applications Features of Monnit ALTA Sensors Wireless range of 1,000+ feet through 12-14 walls.* Frequency Hopping Spread Spectrum (FHSS). Improved interference immunity. Improved power management for longer battery life.** (10+ years on AA batteries) Encrypt-RF (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages). Onboard data memory / storage (up to 512 readings per sensor). - 10 min heartbeats = 3.5 days - 2 hour heartbeats = 42 days Over-the-air updates (future proof). Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. Other power options are also available. Comparison Monnit ALTA Chimney / Flue Temperature Monitoring Kiln Temperature Monitoring High Temperature Food Monitoring And many more... Monnit Other Wireless Platforms Wifi Bluetooth PAGE 1

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) ALTA Commercial Coin Cell Wireless Thermocouple Sensors - Technical Specifications Supply Voltage 2.0-3.8 VDC * Operating Temperature Range (Board Circuitry and Coin Cell) -7 C to +60 C ( 20 F to +140 F ) ** Optimal Battery Temperature Range (Coin Cell) +10 C to +50 C ( +50 F to +122 F ) 1.7 Ounces * Hardware can not withstand negative voltage. Please take care when connecting a power device. PinchPower Enclosures _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 2.470 4.375 3.295 1.111 1.111 ALTA Commercial AA Wireless Thermocouple Sensors - Technical Specifications Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC Using Power Supply) * Operating Temperature Range (Board Circuitry and Batteries) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium ** Optimal Battery Temperature Range (AA) +10 C to +50 C ( +50 F to +122 F ) 4.7 Ounces * Hardware cannot withstand negative voltage. Please take care when connecting a power device. Power Options The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0-3.6 V power supply. The line powered version also uses two standard 1.5 V AA batteries as backup for un-interupted operation in the event of line power outage. Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) ALTA Industrial Wireless Thermocouple Sensors - Technical Specifications Supply Voltage 2.0-3.8 VDC (3.0-3.8 VDC Using Power Supply) * Operating Temperature Range (Board Circuitry and Battery) -40 C to +85 C ( -40 F to +185 F ) ** Included Battery Max Temperature Range: -40 to +85 C ( -40 to +185 F ) Capacity: 1800 mah Optional Solar Feature Solar Panel: 5VDC / 30mA (53mm x 30mm) Charging Temperature Range: Max Temperature Range: Included Rechargeable Battery: 0 to 45 C (32 to 113 F) -20 to 60 C (-4 to 140 F) 600 mah / >2000 Charge Cycles (80% of initial capacity) Enclosure Rating 5.7 Ounces NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) * Hardware cannot withstand negative voltage. Please take care when connecting a power device. PAGE 4

Commercial Grade Sensors: Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc.). Volatile or flammable gas. Dusty conditions. Under low or high pressure. Wet or excessively humid locations. Places with salt water, oils chemical liquids or organic solvents. Where there are excessively strong vibrations. Other places where similar hazardous conditions exist. Use these product within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure: Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt. Protects against wind blown dust. Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit, ALTA, PinchPower, Encrypt-RF and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. ADS-A060-1C (1/18)