GE Sensing & Inspection Technologies. VeriDri TM. Moisture Transmitter. User s Manual

Similar documents
The CE Marking Access to the European Market

DL/DLM. Operating instructions Manuel d instructions Instrucciones de uso

CTC EcoMiniEl. Installation- and Maintenance Manual. External electric boiler. Providing sustainable energy solutions worldwide

805QS Pressure Switch-Transmitter

WIO200 Water in oil sensor

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

WIO200 Water In Oil measuring instrument

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

Model OEM-2 INSTRUCTIONS FOR USE

CO2 Sensor User and Installation Guide

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

MANUAL. for heat press. Secabo TC2

Physikalisch-Technische Bundesanstalt

MANUAL. for heat presses. Secabo TC5 and TC7

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Custom Products for Research. Kugelrohr Short Path Distillation

Operating Instructions

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

SSC-1D installation guide

Models TX-KE and TX-KP Toxic Gas Transmitters

POWERED ANODE SYSTEM

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Installation Instructions

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Strand Lighting Emergency Transfer Cabinet

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

MODEL DPS1 Heated Dew Point Measuring System OPERATORS MANUAL

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Model 5190-E Temperature/Humidity Probe

TL-105 COLUMN HEATER

RK / RK Methane Detector Operator s Manual

GARAGE DOOR OPENER KIT

Model 5190-F Temperature/Humidity Probe

99 Washington Street Melrose, MA Phone Toll Free Visit us at

UNI 321. User s Guide

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

OPERATING INSTRUCTIONS. for the heat press. Secabo TCC

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Figure 1 DirectLine DL423 Sensor. Description, continued

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Optima ZigBee Thermostat

Manual. Monitoring Device BS

Environmental Monitoring SmartSlot Card

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Operation and Maintenance Manual

Combustible Gas Sample-Draw Detector Operator s Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

OPERATING MANUAL RAY-NC 1000 SERIES

Mark 25 Ultrapure Water Conductivity Analyzer

Model PT-05 Model PT-06

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

CTC EcoZenith C 530 l 510

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

EG KONFORMITÄTSERKLÄRUNG EC DECLARATION AND MANUFACTURER S DECLARATION OF CONFORMITY CE DÉCLARATION DE CONFORMITÉ CE DICHIARAZIONE DI CONFORMITÀ

Manual Isolating Barrier D461R1 (Revision 01)

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

SECTION Fluorescent Dissolved Oxygen Measuring System

RK-05 Combustible Gas Transmitter Operator s Manual

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Installation and Wiring 1.

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD12

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

Digital Heat Block User Manual

HIn3550 Magnetic Field Monitor User's Manual

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

RK / RK CO 2 Detector Operator s Manual

Duct Humidity/Temp Sensor

INSTALLATION INSTRUCTIONS

REC LRD0 / LGD0 DE EN FR IT ES NL RU PL LT LV SR CZ RO BG HU

40/40 Duct Mount P/N Installation Guide. Document Ref: TM777670, Rev. (3) June 2017

Owner s Manual. Terpene Trap CF 1000

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

GAS-Mate. Combustible Gas Leak Detector

DMFPM-2R MULTIFUNCTIONAL

Transcription:

GE Sensing & Inspection Technologies VeriDri TM Moisture Transmitter User s Manual

GE Sensing & Inspection Technologies VeriDri TM Moisture Transmitter User s Manual 916-095B January 2009

Table of Contents Introduction............................................... 1 Sample System Guidelines................................. 2 Inserting the Transmitter in the Sample System/Process..... 4 Making Wiring Connections................................ 6 Operating the Transmitter.................................. 8 Powering Up........................................... 8 Error Handling......................................... 8 Cleaning the Transmitter Probe............................. 9 Removing the Transmitter............................ 10 Soaking the Sensor and Shield........................ 11 Evaluating the Probe................................. 12 Specifications........................................... 13 Moisture Ranges..................................... 13 Operating Temperature.............................. 13 Storage Temperature................................ 13 Warm-up Time....................................... 14 Calibrated Accuracy @ 77 F (25 C).................... 14 Repeatability........................................ 14 Response Time....................................... 14 Electronics........................................... 14 Mechanical.......................................... 15 Moisture Sensor...................................... 16 iii

Introduction The GE Sensing & Inspection Technologies VeriDri TM is a lowcost, loop-powered transmitter that provides accurate dew/frost point measurements covering an overall range of 110 o to 40 C (-166 o to 104 o F). It can also be provided to cover a number of moisture ranges from 0 to 10,000 PPMv. The VeriDri is supplied with one 4 to 20 ma analog output that is factory-configured for a specified range. The VeriDri is easy to install, operate and maintain. This manual contains the following sections: Sample System Guidelines Inserting the Transmitter in the Sample System/Process Making Wiring Connections Operating the Transmitter Cleaning the Transmitter Probe Specifications VeriDri Moisture Transmitter 1

Sample System Guidelines You can install the VeriDri transmitter into a sample system or directly into the process. GE recommends that the unit be installed in a sample system to protect the probe from coming into contact with damaging elements in the process. Before constructing a sample system, you should consult a GE Applications Engineer and adhere to the guidelines below. See Figure 1 on the next page for an example of a sample system. Consult Specifications on page 13 for dimensions and other requirements. Sample systems should be kept very simple. The transmitter should be installed so it is perpendicular to the sample inlet. The sample system should contain as few components as possible and all or most of those components should be located downstream of the measurement location. If possible, you should use stainless steel material for all wetted parts. Sample system components should not be made of any material that will affect measurement. Most common filters and pressure regulators are not suitable for sample systems because they have wetted parts that may absorb or release components (such as moisture) into the sample system. They may also allow ambient contamination to enter the sample system. 2 VeriDri Moisture Transmitter

Sample System Guidelines (cont.) Sample Cell Sample Inlet Sample Outlet Vent Figure 1: Example of a Sample System VeriDri Moisture Transmitter 3

Inserting the Transmitter in the Sample System/Process!CAUTION! If you are mounting the VeriDri directly into the process line, you must consult the factory for proper installation instructions and precautions before beginning the following procedure. Use the steps below to install the VeriDri: 1. Make sure the sintered or sheet stainless-steel shield is in place. The shield protects the aluminum oxide sensor from damaging elements in the process. Shield 2. The probe is mounted into the process via the 3/4-16 straight male thread located on the probe. Thread the probe end of the transmitter into the process/sample system fitting. Make sure not to cross thread it. 3/4-16 UNF-2A 4 VeriDri Moisture Transmitter

Inserting the Transmitter in the Sample System/Process (cont.) January 2009 3. Using a 1-1/8 in. wrench, tighten the probe securely into the process using the probe hex nut.!caution! Do not apply force to the transmitter module to tighten the unit into its fitting. Probe Hex Nut VeriDri Moisture Transmitter 5

Making Wiring Connections You must wire the transmitter using the factory-supplied cable which is available in a variety of lengths. Note: If you need to lengthen cables, refer to Table 1 below to splice an extension onto the existing cable. Connect positive to positive and negative to negative. Use the following steps to wire the transmitter to your system. 1. Push the female connector end on the transmitter cable into the mating male connector on the transmitter module. Make sure the pins are properly aligned. Once inserted, secure the connectors together by sliding the metal sleeve on the cable over the connectors and turning it clockwise until it is tight. 2. Using the flying leads at the other end of the transmitter cable, connect the transmitter to your power supply and data acquisition system (DAS) as shown in Figure 2 on the next page. Refer to Table 1 below for a description of the leads in the factory-supplied cable. Table 1: Cable Lead Descriptions Lead Color* Connection Description Blue (+) 7 to 28 VDC Brown ( ) 7 to 28 VDC Connect the shield to ground if desired. *The blue and brown leads also produce a current output equivalent to 4 to 20 ma. 3. Trim any unused leads back to the outer cable jacket in order to remove the bare tinned wire and prevent accidental short circuits. The VeriDri is now ready for operation. 6 VeriDri Moisture Transmitter

Making Wiring Connections (cont.) Power and Measurement Circuits + 7-28 VDC 7-28 VDC Blue Brown Note: The blue and brown leads also generate a current output equivalent to 4 to 20 ma. Figure 2: Wiring Connections VeriDri Moisture Transmitter 7

Operating the Transmitter After proper installation, the VeriDri Transmitter is very easy to use; simply power the unit up and you are ready to begin taking measurements. Since the VeriDri stores moisture calibration data in non-volatile FLASH memory, you do not have to enter data manually or worry about losing data during a power loss. Probes may need to be cleaned occasionally depending on the application. Consult a GE Applications Engineer for required cleaning intervals. If a problem should arise with the probe, see Error Handling below for how the transmitter reacts to error conditions.!caution! Any attempt to open the module or remove the sensor probe will void the warranty. Powering Up After the VeriDri is wired as described in the previous section, you may apply power to the unit. The transmitter takes approximately 20 seconds to initialize and begin normal operation. The unit will meet specified accuracy in 3 minutes. Error Handling In the event of an error condition, the analog output reading is forced to the following values: 22 ma to indicate a shorted probe 3.5 ma to indicate an open probe 8 VeriDri Moisture Transmitter

Cleaning the Transmitter Probe!CAUTION! Be sure to perform the probe cleaning procedure in a well ventilated area. Observe all necessary safety precautions when handling cleaning solvents To clean the moisture probe, you will need the following: Three glass (NOT metal) containers containing the following solvents: 2 containers of approximately 300 ml of reagent-grade hexane or toluene each. 1 container of approximately 300 ml of distilled (NOT deionized) water. IMPORTANT: Make sure the containers are deep enough to submerge the probe. Do not place the transmitter module into the solvents. You should only insert the sensor portion of the transmitter into the solvents. Rubber or latex gloves. Oven set at 50 C ± 2 C (122 F ± 3.6 F) for drying probe. 1-1/8 in. wrench Use the sections that follow to properly clean the probe. VeriDri Moisture Transmitter 9

Removing the Transmitter Use the following steps to remove the transmitter from the installation site: Note: Once the probe is cleaned, it must dry in the oven for 24 hours. 1. Using a 1-1/8 in. wrench, unthread the transmitter from the fitting on the sample system/process using the probe hex nut as shown below. Probe Hex Nut 2. Record the dew point of the ambient air. 3. Disconnect the cable from the module. 4. Unscrew the stainless-steel shield from the probe mount and carefully remove it without touching the sensor.!caution! Any attempt to open the module or remove the probe from the module will void the warranty. Shield 10 VeriDri Moisture Transmitter

Soaking the Sensor and Shield January 2009!CAUTION! Do not place the transmitter module into the solvents. You should only insert the sensor portion of the transmitter into the solvents. Also, do not allow the sensor to come into contact with the surfaces of the cleaning containers or any other hard surface. 1. Wearing gloves, place the sensor in the first container of hexane or toluene and allow it to soak for 10 minutes. 2. Remove the sensor from the hexane or toluene and soak it in the container of distilled water for 10 minutes. 3. Remove the sensor from the distilled water and soak it in the second (clean) container of hexane or toluene for 10 minutes. 4. Remove the sensor from the hexane or toluene and set it aside until the shield has completed the cleaning cycle. 5. Repeat steps 1 to 3, above, to clean the shield. To ensure the removal of any contaminants that may have become embedded in the porous walls of the shield, swirl the shield in the solvents during the soaking procedure. 6. Remove the shield from the hexane or toluene. 7. Carefully replace the shield over the exposed sensor without touching it. 8. Place the sensor with the shield in an oven set at 50 C ± 2 C (122 F ± 3.6 F) for 24 hours. VeriDri Moisture Transmitter 11

Evaluating the Probe 1. Re-connect the cable to the transmitter module and measure the dew point. Make sure you measure the same ambient air as measured in step 2 on page 10. 2. Compare the two ambient air readings. If the new ambient air reading is within ±2 C (±3.6 F) of the first reading, the cleaned probe is properly calibrated and may be reinstalled. If it is not, proceed to step 3 below. 3. If the probe is still not reading the ambient air accurately, repeat the cleaning procedure using soaking times that are 5 times the previous cleaning sequence, until two consecutive ambient air readings are identical. If the above cleaning procedure does not result in accurate readings, contact the factory for assistance. 12 VeriDri Moisture Transmitter

Specifications Moisture Ranges 110 o to 20 C 110 o to 50 C 90 C to 10 C 80 C to 30 C 80 to 20 C 30 o to 20 C 130 o to 70 F 130 o to 40 F 40 o to 70 F 50 o to 50 F -100 to 0 F 0 to 10 PPMv 0 to 100 PPMv 0 to 1000 PPMv 0 to 10,000 PPMv Note: PPMv ranges based on constant pressure, provided at time of order placement. Operating Temperature 40 to 60 C ( 40 to 140 F) Storage Temperature 70 C (158 o F) maximum. The probe should be stored with the plastic cover and desiccant packet threaded onto the probe. Store in a cool, dry environment. VeriDri Moisture Transmitter 13

Warm-up Time Meets specified accuracy in 3 minutes Calibrated Accuracy @ 77 F (25 C) ±3.6 F (±2 C) from -85 F to 50 F (-65 C to 10 C) dew/frost point ±5.4 F (±3 C) from -112 F to -86 F (-80 C to -66 C) dew/ frost point Repeatability ±0.9 F (±0.5 C) from -85 F to 50 F (-65 C to 10 C) dew/frost point ±1.8 F (±1.0 C) from -112 F to -86 F (-80 C to -66 C) dew/ frost point Response Time Less than 5 seconds for 63% of a step change in moisture content in either wet-up or dry-down cycle Electronics Power Supply voltage: 7 to 28 VDC (loop-powered, customer supplied) Output: 4 to 20 ma Output Resolution: 0.01 ma Max. Loop R = 50 Ω (PSV 7), where PSV = Power Supply Voltage Example: Given a 24 VDC Power Supply, Max. Loop R = 50 Ω (24 7) = 850 Ω Cable: 2 m (6 ft.) standard (consult factory for custom lengths) 14 VeriDri Moisture Transmitter

Mechanical Sample Connection 3/4 in. (16 mm) 16 straight male thread with O-ring G 1/2 in with optional adapter Operating Pressure 5 µhg to 5,000 psig (345 bar) Enclosure Type 4X/IP67 European Compliance Complies with the following: EMC Directive 2004/108/EC and PED 97/23/EC for DN<25 EN 61326:1998 Class A, Annex A, Continuous Unmonitored Operation (For EN 61000-4-3 transmitter meets performance criteria A and in a number of frequencies, criteria B per EN 61326) Dimensions Overall: 6.76 1.13 in. (17.17 2.87 cm) Electronics with cable: 4.08 1.13 in. diameter (10.36 2.87 cm) Weight: 5 oz (140 grams) VeriDri Moisture Transmitter 15

Moisture Sensor Sensor Type Thin-film aluminum oxide moisture sensor probe Calibration Each sensor is individually computer-calibrated against known moisture concentrations, traceable to NIST Calibration Interval Sensor recalibration at GE Sensing is recommended every six to 12 months depending on application Calibration Data Factory-calibrated, stored in FLASH Flow Rate Gases: Static to 10,000-cm/s linear velocity at a pressure of 1 atm. Liquids: Static to 10-cm/s linear velocity at density of 1 g/cc 16 VeriDri Moisture Transmitter

Warranty Each instrument manufactured by GE Sensing, Inc. is warranted to be free from defects in material and workmanship. Liability under this warranty is limited to restoring the instrument to normal operation or replacing the instrument, at the sole discretion of GE Sensing, Inc. Fuses and batteries are specifically excluded from any liability. This warranty is effective from the date of delivery to the original purchaser. If GE Sensing, Inc. determines that the equipment was defective, the warranty period is: one year from delivery for electronic or mechanical failures one year from delivery for sensor shelf life If GE Sensing, Inc. determines that the equipment was damaged by misuse, improper installation, the use of unauthorized replacement parts, or operating conditions outside the guidelines specified by GE Sensing, Inc., the repairs are not covered under this warranty. The warranties set forth herein are exclusive and are in lieu of all other warranties whether statutory, express or implied (including warranties or merchantability and fitness for a particular purpose, and warranties arising from course of dealing or usage or trade).

Return Policy If a GE Sensing, Inc. instrument malfunctions within the warranty period, the following procedure must be completed: 1. Notify GE Sensing, Inc., giving full details of the problem, and provide the model number and serial number of the instrument. If the nature of the problem indicates the need for factory service, GE Sensing, Inc. will issue a RETURN AUTHORIZATION NUMBER (RAN), and shipping instructions for the return of the instrument to a service center will be provided. 2. If GE Sensing, Inc. instructs you to send your instrument to a service center, it must be shipped prepaid to the authorized repair station indicated in the shipping instructions. 3. Upon receipt, GE Sensing, Inc. will evaluate the instrument to determine the cause of the malfunction. Then, one of the following courses of action will then be taken: If the damage is covered under the terms of the warranty, the instrument will be repaired at no cost to the owner and returned. If GE Sensing, Inc. determines that the damage is not covered under the terms of the warranty, or if the warranty has expired, an estimate for the cost of the repairs at standard rates will be provided. Upon receipt of the owner s approval to proceed, the instrument will be repaired and returned.

GE Sensing DECLARATION OF CONFORMITY We, GE Sensing 1100 Technology Park Drive Billerica, MA 01821 USA declare under our sole responsibility that the VeriDri Moisture Transmitter to which this declaration relates, is in conformity with the following standards: EN 61326:1998, Class A, Annex A, Continuous Unmonitored Operation (For EN 61000-4-3, the above units meet performance Criteria A, and in a limited number of frequencies, performance Criteria B per EN 61326.) EN 60529:1991+A1:2000 IP67 following the provisions of the 2004/108/EC EMC Directive. The units listed above and any ancillary sample handling systems supplied with them do not bear CE marking for the Pressure Equipment Directive, as they are supplied in accordance with Article 3, Section 3 (sound engineering practices and codes of good workmanship) of the Pressure Equipment Directive 97/23/EC for DN<25. January 8, 2009 Date of Issue Mr. Gary Kozinski Certification & Standards, Lead Engineer CERT-DOC-H1 (August 2004)

GE Sensing DECLARATION DE CONFORMITE Nous, GE Sensing 1100 Technology Park Drive Billerica, MA 01821 USA déclarons comme étant de notre seule responsabilité que le Transmetteur d humidité VeriDri sur lequel porte ce document, est conforme aux spécifications suivantes : EN 61326:1998, Classe A, Annexe A, Fonctionnement continu sans surveillance (Pour EN 61000-4-3, les appareils ci-dessus sont conformes au critère A de performance et, dans un nombre limité de fréquences, au critère B de performance, selon EN 61326.) EN 60529:1991+A1:2000 IP67 conformément aux dispositions de la directive 2004/108/EC (compatibilité électromagnétique). Les appareils indiqués plus haut et tous les accessoires d échantillonnage fournis avec ne portent pas la marque CE pour la directive concernant les équipements de pression, dans la mesure où ils sont fournis conformément à l article 3, section 3 (pratiques d ingénierie sûres et codes de bienfacture) de la directive concernant les équipements de pression 97/23/EC pour DN<25. 8 janvier 2009 Date d émission Mr. Gary Kozinski Certification et normes, ingénieur de fil CERT-DOC-H1 (August 2004)

GE Sensing KONFORMITÄTS- ERKLÄRUNG Wir, GE Sensing 1100 Technology Park Drive Billerica, MA 01821 USA erklären unter alleiniger Eigenverantwortlichkeit, dass die Produkte VeriDri Feuchtigkeitsmesswandler auf das sich diese Deklaration bezieht, die folgenden Normen erfüllen: EN 61326:1998, Class A, Annex A, kontinuierlicher, überwachungsfreier Betrieb (Für EN 61000-4-3 erfüllen die obigen Geräte die Leistungskriterien A und in bei einer begrenzten Anzahl von Frequenzen die Leistungskriterien B gemäß EN 61326.) EN 60529:1991+A1:2000 IP67 und dass sie die Anforderungen der EMC-Direktive 2004/108/EC einhalten. Die oben aufgeführten Geräte und zugehörige, mitgelieferte Schallwandler (Messrohre werden in einer separaten Konformitätserklärung behandelt) tragen keine CE-Kennzeichnung gemäß der Druckgeräte-Richtlinie, da sie in Übereinstimmung mit Artikel 3, Absatz 3 (gute Ingenieurpraxis) der Druckgeräte-Richtlinie 97/23/EG für DN<25 geliefert werden. 8. Januar 2009 Außtellungsdatum Hr. Gary Kozinski Bescheinigung und Normen, Leitungsingenieur CERT-DOC-H1 (August 2004)

USA 1100 Technology Park Drive Billerica, MA 01821-4111 Web: www.gesensinginspection.com Ireland Shannon Industrial Estate Shannon, County Clare Ireland