SLC Receiver READY TEST INPUT 5 OSSD MPCE 6 2 7 8 OSSD2 MPCE 2 SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector
Typical SLC Wiring to MPCEs using Relay Monitor Option (/29) SLC Receiver w/ Relay Monitor Option (/29) READY MPCE MPCE2 RELAY MONITOR 5 6 2 7 8 OSSD OSSD2 MPCE* MPCE2* SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector * To meet Control Reliability and Category requirements, MPCE and MPCE2 should be positively-driven (forceguided) contact devices. (MPCE = Machine Primary Control Element.) MPCE monitoring can be accomplished by wiring normally-closed contacts from each device in series into the Relay Monitor input of the light curtain.
Typical SLC Wiring to SR SLC Monito Safety Relay (SLC Relay Monitor Option not requi) SLC Receiver READY TEST INPUT 2 7 5 6 OSSD OSSD2 SR SLC S2 S22 2 2 8 A2 A SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector * The SR SLC is a self-monito safety relay module, thus SLC Receiver relay monitoring (Option /29 ) is not necessary to meet Category. The SR SLC has internally undant and monito circuitry -- should a fault occur within its logic or safety outputs (including a welded contact), it will fail to safety (outputs OPEN) and prevent subsequent operation until the failure is corrected.
Typical SLC Wiring to SR SLC Monito Safety Relay (using SLC with Relay Monitor Option /29) SLC Receiver 2 8 7 5 6 SLC Transmitter READY OSSD OSSD2 RELAY MONITOR SR SLC S2 S22 2 5 A2 A 2 2 Module must be configu for auto restart via jumper between terminals & 5 Note: Numbers shown refer to pin # s on M2 connector The SR SLC is a self-monito safety relay module, thus SLC Receiver relay monitoring (Option /29 ) is not necessary to meet Category. The SR SLC has internally undant and monito circuitry -- should a fault occur within its logic or safety outputs (including a welded contact), it will fail to safety (outputs OPEN) and prevent subsequent operation until the failure is corrected. If SLC light curtains WITH Option /29 are being used, the RELAY MONITOR input (Pin ) on the SLC Receiver must be connected to the NC status outputs from the SR SLC module as shown above. Module must also be configu for auto restart via jumper between terminals and 5.
SLCS/SLCT is configu for Auto Restart Relay Monitor Disabled Beam Code A # is a floating (n.c.) terminal inside the ASi node it is used here as a convenient spot to tie these three leads together Wiring into the VA-2E-G-SE Safety Node: SLCS/SLCT is configu for Auto Restart Relay Monitor Disabled Beam Code A 2 5 6 7 Wiring into the Terminal Strip on the ASi Demo Case: 8 9 0 2 To SLCS/SLCT Receiver To SLCS/SLCT Transmitter
SLCS and SLCT Optional Feature Selection Wiring Examples: Transmitter Mode A: TEST Transmitter Mode B: TEST
SLCS and SLCT Optional Feature Selection Wiring Examples: Receiver, Auto Restart, RM Enabled, Mode A: K K2 Status Lamp (Optional) K K2 Receiver, RI Enabled, RM Enabled, Mode B: K K2 Status Lamp (Optional) K K2
SLCS and SLCT Optional Feature Selection Wiring Examples: Receiver, Auto Restart, RM Disabled, Mode A: Status Lamp (Optional) K K2 Receiver, RI Enabled, RM Disabled, Mode B: Status Lamp (Optional) K K2