TECHNICAL BULLETIN. Model Smart Digital Humidistat. Installation and Owner's Manual. General Description

Similar documents
Model Smart Digital Humidistat

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Installation Instructions

Wiring Instructions. High-Capacity Steam Humidifiers

INSTALLATION & USER MANUAL

Safety & Installation Instructions

Safety, Installation, and Operation Manual

T-32-TS Touchscreen Thermostat. Installation Manual

Automatic Digital Humidifier Control

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

PerFormance Pro t4900 school series InstallatIon GUIDe

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

W43A Humidistat. Features and Benefits

Installation Instructions Owner s Manual

Installation Guide IM 1248

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

ELECTRONIC COMMUNICATING THERMOSTAT

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

INSTALLATION INSTRUCTIONS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

CAREL heatersteam Electric Element Steam Humidifiers

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

HE120, HE160 Humidifier Installation Kit

Insty-Pac Steam Humidifiers

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

RC-2000 Thermostat Installation Instructions

PS4000 and PS5000 Touchscreen Programmable Thermostat Installation and Owners Manual Robertshaw 01/

HE360 Humidifier Installation Kit

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

User s Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INSTALLATION MANUAL. Need Help? This manual covers TopTech models: TT-N-721 and T721. Power Type. Thermostat Applications Guide.

Installation Instructions

EXPERT TRI-STAR. Temperature controller. User s Manual

PerFormance Pro t12000 series InstallatIon GUIDe

Operator: Save these instructions for future use!

H1008A,D Automatic Humidity Controls

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Installation, Start-Up, and Operating Instructions

Instruction Guide: Thermostat Operation

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Programmable Thermostat

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Must be installed by a trained, experienced technician

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

INSTALLATION MANUAL. This manual covers TopTech models: TT-N-851. Need Help? Power Type. Thermostat Applications Guide. Page.

T7200D,E Series 2000 Commercial Microelectronic Thermostats

SC Installation, Operation & Application Guide

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

T8401C Electronic Thermostats

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

T874 Multistage Thermostat and Q674 Subbase

Safety and Installation Instructions Model 1700

Predator Controller Hardware Family

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

Duct and Rough Service Carbon Monoxide Sensor

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

SC Installation, Operation & Application Guide

T8611M Deluxe Programmable Heat Pump Thermostats

RECOMMENDED LOCATION STEP BY STEP INSTALLATION. MODEL S 200P, 800BP and 97 POWER HUMIDIFIERS

Dual Column Dehydrating Breather Manual

Product Manual SZ1009

WHITE-RODGERS COMFORT-SET 90 SERIES

Net/X US32 Universal Setback Communicating Thermostat

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

FX-PDD Duct Smoke Detector Installation Sheet

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

120 VAC SYSTEM CONTROL KIT

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

TCB-IFTH1GUL. 24V Thermostat Interface. Installation Manual. Model name: English FOR INSTALLER

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

T7079A,B Solid State Remote Temperature Controllers

Operator: Save these instructions for future use!

Installation Instructions

INSTALLATION INSTRUCTIONS

Transcription:

TECNICAL BULLETIN Model 072000 Smart Digital umidistat Installation and Owner's Manual TB 213 P/N 090375A0213 REV. G Copyright 2004-2008, EWC Controls Inc., All Rights Reserved R %R TEMP Package includes: 1 #072000 Smart umidistat 1 Foam Gasket 1 Mounting Template 1 Technical Bulletin #TB213 2 Mounting screws 2 Wall anchors 1 #OAS Outside Air Sensor AUTO ME MAN General Description The 072000 is a digital humidifier control that can automatically adjust the indoor humidity set point as the outside air temperature changes. This intelligent control will maintain accurate humidity levels and a more comfortable indoor environment. The actual indoor relative humidity is always displayed on the LCD screen. When the UP or DOWN keys are pressed, the humidity set point is displayed and can be adjusted using the UP and DOWN arrow keys. An outdoor temperature sensor is included, and must be connected in order to fully utilize the features of the 072000. The outdoor temperature sensor allows the humidistat to automatically adjust the humidity set point, to avoid condensation on windows. It is also a convenient way to read the outdoor air temperature at any time. 1 The outdoor sensor is not required to use the umidistat in the basic or manual mode. The 072000 operates on 24vac, and has a set of isolated dry contacts for activating the humidifier. Terminals are also provided for the Outdoor air Temperature Sensor. (Part# OAS) The 072000 can be installed on the return air duct or, it can be installed on an interior wall within the conditioned space. EWC Controls recommends an interior wall installation. NOTE: If the return air duct is chosen as the location, the VAC fan should be set to run continuously, in order to obtain an accurate sampling of the actual living space relative humidity condition.3 385 wy. 33 Englishtown, NJ 07726 Ph: 800-446-3110 - Fx: 732-446-5362

Displaying the Relative umidity The 072000 normal display shows the humidity level in the home. The example at right shows the humidity reading at 36%. The R symbol blinks when the humidistat is requesting (calling for) humidification. The R symbol remains steady when the humidity set point is satisfied. NOTE: Allow 24 hours for the 072000 to fully stabilize and display the accurate humidity level in your home. Changing the R Setpoint When the up or down %R keys are pressed once, the 072000 displays the relative humidity set point. olding the UP key will raise the R set point and, holding the DOWN key will lower the R set point. Upon initial power up, the 072000 defaults to an R set point of 30% R. You can adjust the set point as desired no matter which mode of operation you prefer. See "Selecting Manual Operation" and Selecting Automatic Operation" for more information on the proper setting of the R set point. R R %R Displaying the Outdoor Temperature Pressing the TEMP key will display the outdoor temperature. The 072000 will display outdoor air temperatures from -9 to 98 F. TEMP Selecting Manual or Auto Operation Moving the AUTO/MAN switch to the MAN position selects manual operation. The 072000 will maintain the R set point selected with the up and down %R keys. As the outdoor temperature changes, the home-owner will have to re-adjust the R set point to achieve a comfortable environment and avoid condensation on windows and walls. Table 1 shows the suggested R set points for different outdoor air temperatures. AUTO MAN 2

OUTDOOR TEMPERATURE +30 F +20 F +10 F +0 F -9 F ADJUST %R TO 40% 35% 30% 25% 20% Table 1. Suggested R manual set points for different outdoor temperatures. Selecting Automatic Operation Moving the AUTO/MAN switch to the AUTO position selects automatic operation. The 072000 will automatically adjust the R set point up or down as the outdoor temperature changes. You do not have to adjust the R set point unless you want to. Simply push the UP or DOWN arrow to increase or decrease the humidity level in the home. The 072000 will calculate and display the new set point on the LCD screen. Table 2 shows the adjusted R set points for different outdoor temperatures, using a base set point of 40% relative humidity. The 072000 computer will automatically lower the R set point as the outdoor temperature falls below 35 F. Above 35 F., the 072000 will operate based on the base set point. AUTO OUTDOOR TEMPERATURE +35 F +30 F +25 F +20 F +15 F +10 F +5 F 0 F -5 F -9 F MAN ADJUSTED %R 40% 38% 35% 33% 30% 28% 25% 23% 20% 18% Table 2. Computer adjusted R set points for different outdoor air temperatures based on a 40% R setting. NOTE: Adjusting the base set point will change the calculated set point, when the outside air temperature drops below 35 F. The 072000 will display thenew set point after the processor has calculated a new set point based on theoutdoor air temperature. 3

Wiring Diagrams for 072000 umidistat The diagram below shows the wiring arrangement with an external 24vac transformer To power up the 072000 and the humidifier. Outdoor Temperature Sensor To Thermostat Standard Furnace/Air andler C Y W G R C R 072000 UMIDISTAT UMIDIFIER The diagram below shows the wiring for the ULTRA-ZONE Model S-2000 and S-2020 Steam umidifiers Outdoor Temperature Sensor C 072000 UMIDISTAT C R S-2000/S-2020 STEAM UMIDIFIER G1 R G2 A A Line Voltage 120VAC, 60z 24VAC Transformer REFER TO TE S2000/2020 OWNERS MANUAL To/From VAC System Terminal Block REFER TO TE S2000/2020 OWNERS MANUAL NOTE: igh voltage may cause serious injury from electrical shock. Disconnect electrical power to the VAC system before starting the installation. NOTE: Sharp edges may cause serious injury from cuts. Use care when cutting template openings and handling any duct work. 4

Installation, Duct Mounting The umidistat can be installed on the return air duct to sense the humidity level whenever the fan is operating. Use the "Duct Mounting Template" provided to cut an opening in the duct for airflow to the humidity sensor and two holes for the mounting screws. Use the foam gasket to create a seal against the sheet metal. Also punch a 1/4 hole in your duct and route the wires into the duct and out the new opening. This allows you to make your connections easily without having to route the wires through the vented ribs. DO NOT REMOVE the vent covers when installing this device on the return duct, or only remove what is necessary to run your wires through a vent/rib opening. WIRING The wiring can pass through the duct or enter the subbase through an open vent rib at the bottom or top of the subbase. TEMPLATE- DUCT MOUNTING Warning: Leave the vent hole covers in place, when mounting the umidistat on the return air duct! Only remove as much vent cover material as necessary to route your wires. C R All work should be done to local and national codes and ordinances. Use color-coded, multi conductor 18 awg, solid copper wire. Wire number to number or letter to letter on each control. Route wires through vent ribs when inserts are removed, or route wires thru duct and come in behind the sub-base. Installation, Wall Mounting The umidistat can be installed on a wall within the conditioned space. Use the "Wall Mounting Template" provided to cut a small opening in the wall for the wiring and drill two pilot holes for the mounting screws. Use the foam gasket to create a seal against the wall if desired. Warning: Seal up the wire hole made in the wall to prevent air leakage from effecting the R sensor on the 072000 printed circuit board. Use plumbers putty, wall compound, or even duct tape to seal the hole. C R WALL MOUNTING Route wires through this hole. Use the supplied wall anchors if necessary. Remove the plastic covers at all vent ribs at the top and bottom of the subbase, when mounting on interior walls. 5

Attaching the 072000 umidistat After installing and wiring the subbase, attach the 072000 by placing the front over the two top subbase brackets, and swinging the front cover down and snapping it in place. Power up the 072000 after attaching it to the subbase. Front Sub-Base Wall or Duct BE SURE TO PEEL OFF TE PLASTIC PROTECTIVE FILM FROM TE FRONT DISPLAY WEN TE INSTALLATION IS COMPLETE. R %R TEMP AUTO ME MAN 6

Forced Air Zone Controls SUBMITTAL SEET Model OAS (OUTSIDE Air Sensor) The OAS Outside Air Sensor allows precise real time monitoring of the Outside Air temperature on your Zoned VAC system. The Optional OAS wires directly into the BMPlus series or UZC series control panels allowing the Control System to monitor the outside air temperature in heating mode. Using the adjustable potentiometer on the Control Panel, the installer can set the desired outdoor temperature changeover setting, to engage supplemental or backup heating systems. The OAS comes standard with the K2000 Economizer System and the 072000 Smart Digital umidity Control. Refer to the K2000 and the 072000 Technical Bulletins for the specific Outside Air Features & Functions provided, with these products. The OAS is a versatile device because it can be mounted on an outside wall or an outside air duct. See Page 2 & 3. Make sure the OAS is mounted completely outside of the house, on the North, East, or West side of the building. Avoid direct sunlight. Do not mount the OAS low to the ground where snow can cover it. Do not mount the OAS close to exhaust vents of any type. Use a dedicated 2 conductor 18AWG solid copper jacketed thermostat cable to connect the OAS to the Zone Control System, Economizer or the Smart umidistat. Avoid running cable in close proximity to line voltage circuits, or inside a conduit with other circuits. Avoid wire runs in excess of 100 ft. The Sensor wiring is not polarity sensitive. OAS equipped panels have a designated terminal block for the OAS. Be sure to remove the factory supplied resistor on the Outside Air Sensor terminal block of the Ultra Zone panel, and connect the field wiring to those terminals instead. On some panels, make sure you enable the OAS Dip switch. Now dial in the Outside Air Changeover setting you desire. Dual fuel eat Pumps and Multi-Stage eating systems can be controlled without the need for bulky mechanical outside air thermostats or expensive dual fuel kits. To test an OAS disconnect the wire leads from the control panel and remove it from the duct. At room temperature (75 F.) the ohm reading on an OAS will be approximately 10.5K ohms (10,500 ohms). Or leave the OAS where it is and place a separate temperature probe of known accuracy in the same location as the OAS and measure the OAS resistance against the table provided on page 4. You should measure a value within 5% of the table value and the separate temperature probe reading. MAJOR PARTS INCLUDED IN TE OAS OUTSIDE AIR SENSOR ASSEMBLY Cover Top View Cover Side View Cover Bottom View ousing Internal View EWC CONTROLS INC. ousing Side Open View Sensor Assembly with Protective Sleeve & 12 wire leads 5/16 DIAMETER END CAP 1/4 Tube Assembly with Integrated Back Plate 5 3/4 INSERTION EWC 7 CONTROLS INC. 385 wy. 33 Englishtown, NJ 07726 Ph: 800-446-3110 - Fx: 732-446-5362

Forced Air Zone Controls TM Model OAS (OUTSIDE Air Sensor) The OAS is constructed of UV stabilized Poly Carbonate Plastic with seamless aluminum tubing frame and a highly accurate thermistor with 24awg 12 leads. The unique construction provides a thermal barrier between the temperature probe and the duct work allowing precise air temperature measurements. To test an OAS, disconnect the wire leads from the control panel and remove it from the duct or wall. At room temperature (75 F.) The ohm reading on an OAS will be approximately 10.5K ohms (10,500 ohms). Or leave the OAS where it is and place a separate temperature probe of known accuracy in the same location as the OAS and measure the OAS resistance against the table provided below. You should measure an approximate value within 5% of the table value and the separate probe reading. Temporarily disconnect the OAS from the field wires to test continuity TEMPERATURE (F) RESISTANCE/OMS TEMPERATURE (F) RESISTANCE/OMS -5 100184 50 19903 0 85340 55 17438 5 72906 60 15313 10 62460 65 13475 34K 30*F FIELD WIRES CONNECTED TO 072000 OR ZONE PANEL 15 20 25 30 53658 46220 39917 34562 70 75 80 85 11884 10501 9298 8249 35 30000 90 7333 40 26104 95 6530 OUTSIDE WALL INSIDE WALL 45 22767 100 5826 8 EWC CONTROLS INC. 385 wy. 33 Englishtown, NJ 07726 Ph: 800-446-3110 - Fx: 732-446-5362