SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Similar documents
SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

System Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

EVO192 v3.0 Fire and Burglary What s New

636 and 646 Keypads. User s Manual

INSTALLATION MANUAL PC56O. Version 1.OA

ESPRIT 616/626 KEYPADS. User Manual P R D O X S E C U R I T Y S Y S T E M S. Model 626 READY UM ESPRIT PRINTED IN CANADA 2ND TRBL

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

ESPRIT. 616/626 KEYPADS. User Manual P R D O X. Model 626 READY S E C U R I T Y S Y S T E M S UM ESPRIT

All-In-One Wireless Security System V1.0. Model #: MG-6060

GEM-P800 Programming Instructions

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Digiplex Control Panel (DGP-848) - V4.0

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

INSTALLATION MANUAL PC15OO

Light " " = TRBL MODEL 633 KEYPAD TROUBLE DISPLAY. [7] Communicator fail to report. Fire trouble. Tamper or zone wiring fail. Telephone line monitor

INSTALLATION MANUAL PC25OO

4-PGM Expansion Module

Property of Monitronics Inc

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

8-zone Expansion Module

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

Installation Manual Premier 412/816/832. Issue 10

Paradox Security System Graphic Dept - PRINTED IN CANADA. keypad entries in memory. arming permits movement in pre-selected,

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

System Introduction. 1.1 Specifications

INSTALLATION MANUAL & PROGRAM RECORD SHEET

10-Zone Spectra LED Keypads

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

642 LCD Keypad. User Manual

Digiplex LED Keypads User s Manual

System Introduction. 1.1 Specifications S E C T I O N 1

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

Property of Monitronics Inc

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

AXI LED USER MANUAL (REV. 1.0)

Version 1.03 January-2002 USER S MANUAL

Programming Worksheets

INSTALLATION MANUAL DV8OOO. Software Version 1.0

INSTALLATION MANUAL. PC3OOO Version 7.6W

Control/Communicator Installation Manual

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

GEM-P800. Control Panel/Communicator. Installation Instructions

LCD and 16-Zone LED Keypads. User s Manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

INTRODUCTION. The use of any power source other than a PC4204 to repower the Combus will result in a system malfunction.

CC488. Quick Reference Guide Solution Ultima 880

EasyLoader AV-2004, AV Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Version 2.

System Manual W A R N I N G. PC6O1O Software Version 2.1

Radionics D4112 Program Sheet

Digiplex LED Keypads. User s Manual

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

Quick Programmer s Manual

NetworX Series NX-4V2 Control Panel Installation and Startup

CA60Plus. Installation manual

CC408. Quick Reference Guide Solution 880

2000 Series. Program Entry Guide. Control Panels

Training Manual Multi-Language with Wireless

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

PROGRAMMING WORKSHEETS

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

MR-2602 Two Zone Fire Alarm Control Panel

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

First Alert 1200C Installer Notes M. Leuck

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

Installation Instructions

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

NESS D8 CONTROL PANEL AND DIALLER

3 User s settings. 3.3 Internal clock setting

Transcription:

-961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3 seconds. (2) Connect a jumper between "reset jumper" pins. (5) Remove jumper. (3) Connect AC and/or battery. Factory default installer and master codes will be reinstated. Values entered at addresses 059-243, as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change. PANEL ANSWER OPTIS: ADDRESS 000: (factory default [2ND], [8]) Answering machine override 2nd call time: [2ND] or [1] answering machine override disabled. [2] = 16 sec. [3] = 24 sec. [4] = 32 sec. answer. [5] = 40 sec. [6] = 48 sec. [7] = 56 sec. [8] to [F] = 60 sec. Entering [2ND] [2ND] - Panel will not answer. PANEL IDENTIFIER: 001: 002: PC PASSWORD: 003: 004: Number of rings before answer: Value entered determines number of rings before INSTALLER CODE: (reset code 737373) Full access to programming, except access codes. (addresses 008-058) No access to arming/disarming. Can be used to modify installer code. Use only numeric keys from [1] to [10]. (key [10] = 0) 005: 006: 007: INTELLIZE DELAY: ADDRESS 059: First digit: (factory default [3]) [1] = 16 sec. [5] = 80 sec. [9] = 144 sec. [BYP] = 208 sec. [2] = 32 sec. [6] = 96 sec. [10] = 160 sec. [MEM] = 224 sec. [3] = 48 sec. [7] = 112 sec. [11] = 176 sec. [TRBL] = 240 sec. [4] = 64 sec. [8] = 128 sec. [12] = 192 sec. [2ND] = 256 sec. STREAMLINED SECTI PROGRAMMING Can be used to program s 00 to 34. (addresses 060 to 199) Press [ENTER] installer code [2] [7]. ([2ND] [ENTER] flashes alternately.) Enter a 2-digit number, followed by 8 digits to program that (confirmation beep). will be saved automatically and the software advances to the next programming. To exit programming mode press [CLEAR]. TELEPHE AND ACCOUNT NUMBERS: (reset empty) Press [TRBL] at the end of a phone number if less than 16 digits are programmed. If only one central station phone number is used, program the same number for telephone number 1 and 2. [10] = the number "0" [BYP] = switch from pulse to tone while dialing [11] = [MEM] = pause 4 seconds [12] = # [TRBL] = end of number - 1 - HEXA DISPLAY If key is lit = 8 = 4 = 2 = 1 If key is lit = 8 = 4 = 2 = 1 Value of 2 ND digit = 10 ( 8 2 = 10) Value of 1 ST digit = 3 ( 2 1 = 3) VALUE = "3A" No display = SKIP (empty) No light = 0 10 = [0] = [A]

COMPUTER TELEPHE NUMBER: (View at addresses 060 to 067.) 00 / / / / / / / 01 / / / / / / / 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. CENTRAL STATI TELEPHE NUMBER 1: (View at addresses 068 to 075.) 02 / / / / / / / 03 / / / / / / / 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. CENTRAL STATI TELEPHE NUMBER 2: (View at addresses 076 to 083.) 04 / / / / / / / 05 / / / / / / / 9 10 11 12 13 14 15 16 Press [TRBL] to end phone number if less than 16 digits are programmed. ACCOUNT "A" AND "B": (View at addresses 084 to 087.) 06 / / / / / / A B If only one account number is required, the same number must be entered for both account "A" and "B". REPORTING CODES: (reset code = empty" [2ND] [2ND]) All digits from [1] to [F] are valid. Enter [2ND] (skip) = digit will not be reported. For 3 digit account numbers, enter "skip" ([2ND]) as first digit. If CTACT I.D. format (all codes) is selected, s 07 to 32 are preprogrammed and do not have to be programmed. (Select Contact I.D for both central station numbers at 33 - address 194 - key [10].) - 2 -

REPORTING CODES: (reset code "empty") ALARM CODES ZE 1 TO 8: 15 Zone 1 Zone 2 Zone 3 (fire) Zone 4 120 121 122 (See add. 220) 123 16 Zone 5 Zone 6 Zone 7 Zone 8 124 125 126 127 Sections 17 to 20 are not available. software advances automatically from 16 to 21. RESTORE CODES ZE 1 TO 8: 21 Zone 1 Zone 2 Zone 3 Zone 4 144 145 146 147 22 Zone 5 Zone 6 Zone 7 Zone 8 148 149 150 151 Sections 23 to 26 are not available. software advances automatically from 22 to 27. TROUBLE CODES: 27 Max. auxiliary current Bell disconnect/ max. bell current Battery disconnected/ low voltage Power failure 168 169 170 171 28 Program change Timer loss Fire loop trouble Test report 172 173 174 175 TROUBLE RESTORE CODES: 29 Max. auxiliary current Bell disconnect Battery disconnected/ low voltage Power failure 176 177 178 179 For single digit reporting enter "skip" ([2 ND] ) as first digit. 30 Tamper/wiring fault Timer programmed Fire loop trouble TLM trouble restore 180 181 182 183-3 -

REPORTING CODES: (continued) (reset code "empty") SPECIAL CODES - FORMATS - PGM: 31 32 [ 2ND] Panic 1 Panic 2 Panic 3 Partial arming 184 185 186 187 33 Auto / Espload arm 188 Arm with master code 189 No Movement / 190 late to close Tamper on input 1-6 191 2nd digit: value must be entered i.e. [2 ND] 34 Disarm with Espload Disarm with master code 1st digit: telephone 1 format 2nd digit: telephone 2 format 1st digit: PGM 1 TYPE 2nd digit: PGM 2 TYPE PGM 1 (1st, 2nd digit) PGM 2 (1st, 2nd digit) PGM 1 (3rd, 4th digit) PGM 2 (3rd, 4th digit) 192 193 194 195 196 197 198 199 No movement for specified time/panel not armed at specified hour - see addresses 245, 246, 253. 1st digit of zone tamper is reported with 2nd digit of input 1-6 alarm codes - see addresses 120-125. COMMUNICATOR FORMATS [2 ND ] = ADEMCO slow (1400Hz, 1900Hz, 10bps) [6] [1] [2] [3] [4] [5] = (1400Hz, 1800Hz, 10bps) = SILENT KNIGHT fast (1400Hz, 1900Hz, 20bps) = SESCOA (2300Hz, 1800Hz, 20bps) = RADIICS (40bps with 1400Hz handshake) = RADIICS (40bps with 2300Hz handshake) [7] [8] [9] [10] [ TRBL] = RADIICS with PARITY (1400Hz, 40bps) = RADIICS with PARITY (2300Hz, 40bps) = ADEMCO express = ADEMCO contact ID (selected codes) = ADEMCO contact ID (all codes) = DTMF - no handshake (personal dialing) FEATURE SELECT PROGRAMMING es 200 to 2 2. ""/"OFF" status of the key lights determines feature selection. In programming mode, enter 3 digit memory address ( 200 to 242). To save entries, press [ ENTER]. To exit programming mode press [ CLEAR]. Reset = "OFF" for addresses 200 to 2 2 200: CODE PRIORITY SELECT: [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [ BYP ] [ MEM ] [ TRBL ] [2 ND] 9 10 11 12 13 14 15 16 SYSTEM "A" / STAY 202: SYSTEM "B" / AWAY 9 10 11 12 13 14 15 16 204: Codes with bypass access 9 10 11 12 13 14 15 16-4 -

FEATURE SELECT PROGRAMMING (continued) (On/off status of key lights determines which feature is selected.) 206: Telephone line monitor PS1/Keyswitch = regular arm / (A B) PS1/keyswitch arming Call back Auto arm on time Auto arm on no movement Pulse dialing Partitioning Silent zone/panic generates a silent alarm (1:2) PULSE EUROPE REPORTING OPTIS Bell squawk on arm/disarm Auto zone shut down 208: Automatic event buffer transmission (keys [1] & [3], PS1) (keys [4] & [6]) Panic 1 Panic 2 Panic 3 (keys [7] & [9]) Panic 1 silent (PS1) Panic 2 silent Panic 3 silent Key [10] regular arm / (A B) Key [11] stay or system A arm 6 digit access codes Tamper Recognition Beep on exit delay Report zone restore on bell cut-off Zones with (1K Ω ) Always report disarm [2 ND] 206, Key [2 ND] [1] [1] [2] stay arm / System A [2 ND ] [1] [3] OFF OFF OFF [4] OFF [5] [6] [7] Tone dialing (DTMF) [8] [9] generates only a report [10] (1:1.5) PULSE USA [11] 206, Key [11] [12] [12] TYPE [ BYP] [11] [12] [ MEM] [ TRBL] OFF OFF Reporting disabled Regular reporting [2 ND] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [ BYP] [ MEM] [ TRBL] 210: Exclude power failure from trouble display [2 ND] Auto arm = regular arm / (A B) No tamper bypass Audible trouble warning 20 sec. delay before alarm transmission Keypad 1 zone supervision (zone 7) Keypad 2 zone supervision (zone 8) audible audible fire 4 digit on zone closure no only after alarm TELEPHE LINE MITOR OFF OFF TLM disabled TLM generates trouble only generates an alarm if armed silent alarm becomes audible (address 206, key [9] has to be OFF) REPORTING OPTIS Split reporting: Alarms System report Double reporting DIALING SEQUENCE (tel. No.) 1,2,1,2,1,2,1,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm. 2,2,2,2,2,2,2,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm., 2,2,2,2,2,2,2,2, fail to comm. On alarm, all reports are made to Tel. #1 until system is disarmed. (Once disarmed system reports are made to Tel. #2) TAMPER / WIRE FAULT DEFINITIS 208, Key [10] [11] SYSTEM ARMED [10] [11] Alarm as per individual zone definitions Always generate trouble and alarm, audible or silent as per individual zone definitions OFF OFF SYSTEM DISARMED Tamper supervision disabled No alarm, trouble code reported Silent alarm. Trouble and alarm codes reported Audible alarm. Trouble and alarm codes reported Exception: for 24 hour zones the tamper definition will follow the audible/silent alarm definition of the 24 hour zone. Silent zones will generate a silent alarm. [1] [2] stay arm / System A [3] [4] [5] [6] tamper follows zone bypass definition [7] [8] [9] [10] PS1 software version 1.1 [11] Keypad software versions prior to 4.0} Keypad supervision must be OFF [12] PS1 software versions 2.0 onward Keypad software versions 4.0 onward} Keypad supervision must be (See Wiring Diagram) OFF OFF - 5 -

ZE DEFINITI: (reset = " ") SELECT: [1] [2] [3] [4] [5] [6] [7] [8] 212 Intellizone = 220 24 Hr. / Fire = When zone 3 is defined "24 Hour" it becomes a fire zone 228 Follow = 236 Bypass = 240 Stay / system A Zones that are not selected at addresses 220 to 232 become "Delay 1" zones. 216 Silent = 224 Instant = 232 Delay 2 = 242 System B [1] [2] [3] [4] [5] [6] [7] [8] DECIMAL PROGRAMMING Values entered at addresses "244-255" contain 3 digits between "000" and "255". ([10] = 0) 244: 245: 246: 247: 248: 249: 250: 251: 252: 253: 254: 255: / (days) Auto test report every? days (between "001" and "255") (000=disabled) / (hours) Auto test report / Auto arm time (between "000" and "023") / (minutes) Auto test report / Auto arm time (between "000" and "059") / (seconds) Exit delay (factory default / (seconds) Entry delay 1 (factory default / (seconds) Entry delay 2 (factory default / (minutes) Bell cut-off time / ( x 15 msec.) Zone speed (factory default / (minutes) Power failure report delay (factory default / ( x 15 minutes) Time for "No Movement" Report ( 000=disabled) (factory default / (factory default seconds) seconds) seconds) minutes) msec.) minutes) (000=disabled) / Installer lock ( 147 = locked, 000 = unlocked) (factory default unlocked) 60 45 45 5 PGM timer setting: 001 to 127 for seconds and 129 to 255 for minutes (factory default Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 128 = 133) 600 30 8 hours) 5 seconds). DECIMAL VALUE DISPLAY If key is lit = 8 = 4 = 2 = 1 Total value ( 57) ( 8 1 32 16 = 57) If key is lit = 128 = 64 = 32 = 16 No light = 0-6 -

ACCESS PROGRAMMING Programs features quickly, without entering addresses or numbers. To activate key access programming, press [ENTER], followed by installer, master or user code 1. (Code required depends on the feature you wish to access - see below.) Then press the key corresponding to the desired feature. Press [ENTER] or [CLEAR] to exit. key [9] "Auto arming" time program (accessible to master and user 1 only) Key [9] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [MEM] "Panel time" and clear "trouble 8" (all 3 codes) Key [MEM] flashes. Enter two digits (00 to 23) for hours 2 digits (00 to 59) for minutes. [BYP] Test report (all 3 codes) Reporting is at address 206 keys [11], [12]. A value must be entered at address 175, and both telephone and account numbers must be programmed. [TRBL] Call Espload via telephone (all 3 codes) Panel identifier and PC password (addresses 001-004) and computer telephone number (addresses 060-067) must be programmed. [AWAY] Answer Espload (all 3 codes) This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem setup", and panel phone number programmed (works also without ADP-1). [STAY] Cancel communication attempts (master code and user 1 can only stop calls from/to Espload) Until next reportable event (installer code - all communications) [2],[6] Installer test mode (installer code only) In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long) indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones. [2],[9] Auto arming time program (accessible to installer code only) (Same as key [9] above) When communicating with Espload, it is impossible to enter programming mode. CNECTI DIAGRAMS The system hardware will recognize the following zone conditions: ZE connection without resistor (N.C. contacts) address 208, key [MEM] = "on" key [10] = "off" (reset) key [11] = "off" (reset) N.C. contacts see Figure 1 Keypad zones always use (1K OHM) PG738EX ZE connection with resistor (N.C. and N.O. contacts) address 208, key [MEM] = "off" (reset) key [10] = "off" (reset) key [11] = "off" (reset) N.C. and/or N.O. contacts, see Figure 2 ZE connection with resistor and tamper recognition (N.C. contacts) address 208, key [MEM] = "off" key [10] = See "Tamper/wire Fault Definitions key [11] = and Options" Tamper fault transmits separate code, see Figure 3-7 -

ESPRIT 738 EXPRESS WIRING DIAGRAM Service Keypad AUX - GRN YEL Caution: Disconnect battery before replacing fuse. Four pin connector canbeusedfor quick installation of an Esprit keypad. BATT 5AMP Charging and battery test LED (every 60 seconds) RESET JUMPER PARADOX SECURITY SYSTEMS ESPRIT 738 EXPRESS "TLM" LED: Short flash = OK Long flash = Fault SERIAL OUTPUT DIALER OFF = Disabled Constant = On Line - BLACK RECHARGEABLE BATTERY BATT BELL RELAY OPTI UL/ULC 12VDC / 7AH To cabinet and grounding rod SERVICE PAD COM N.C. N.0. AC PG1 PG2 BELL- AUX - GRN YEL 1/7 COM 2/8 3/9 COM 4/10 5/11 COM 6/12 R-1 T-1 RING TIP N.O. contacts GRY BRN GRN Warning: Disconnect telephone line before servicing. RJ31X CA 38A UL: K12 model T16 V4O ULC: Frost model FTC 1637 Warning: Improper connection may result in damage to the system. TRANSFO 16.5VAC 40VA A.C. POWER BELL OUTPUT will shut down if current exceeds 3A. BELL SIREN UL/ULC Wheelock 46T-12 - - Smoke and heat detectors YEL GRN For zone connections see diagrams below AUX POWER 400mA max. 250mA max. for 24 hr. standby. To connect additional wiring to auxiliary power, use the red () and black (-) keypad connectors. Aux power will shut down if current exceeds 1A. BLK 220 Zone 3 = Fire zone if zone definition is "24 hour". ZE 7or8 N.O. N.C. PS1 software version 1.1 Keypad software versions prior to 4.0 Keypad supervision must be OFF PS1 software versions 2.0 onward Keypad software versions 4.0 onward } } Keypad supervision must be (See 210, key [11] [12]) N.O. ZE 7or8 N.C. Not on UL systems P R RMED RE DYDOX MAX 5 per system PS1 PAD 639/640 MAX 5 per system N.C. N.C. ZE 7 ZE 8 PAD 616/626/633 MAX 5 per system For resistor values, refer to 639/640 installation manuals. FIRE RESET To program PGM1 to conduct 4 second smoke detector reset when [ CLEAR] and [ ENTER] are pressed simultaneously: 195 = [ BYP] (first digit) 198 = [2 ND] [6] 196 = [5] [10] 254 = [10] [10] [4] Keyswitch can be used in parallel with keypad (or PS1). SWITCH CNECTI 220Ω KYPD GRN SWITCH KYPD BLK FIRE ALARM ZE CNECTIS PGM maximum 50mA GROUND START CIRCUIT PGM OUTPUT RELAY PGM AUX Smoke detector - Z3 COM Smoke detector - WHT BLK PGM AUX WHT BLK PGM AUX MR3-UL MR3-UL Smoke detector power supervision relay, 12VDC Smoke detector must be 4 wire latching - UL Falcon model 5454, ULC BRK 2412. Power supervision relay model MR3-UL. RNG Not permitted on UL listed systems YEL COM BRN N.C. N.O. YEL SECURITY SYSTEMS 780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313 http://www.paradox.ca Paradox Security Systems Graphic Dept PRINTED IN CANADA