Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Similar documents
Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

G6RC Series TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

MERIT SERIES Downflow

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

RG7D 1-Stage Heat Series

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

36,000-62,000 BTUH Nominal Capacity

FG7T (C and L Series)

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Vertical Upflow Horizontal Left Air Handlers

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

ELITE SERIES Downflow - High Efficiency Blower Motor

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Modular Multi-position Air Handler

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

8+* Bulletin No November 1997

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

GMS9/GCS9 SERIES 93% AFUE

Multi-Position Gas Furnaces

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Ruud Achiever Plus Series Multi-position Gas Furnaces

TECHNICAL SPECIFICATIONS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

13 GEP A L P - 1 A

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Cooling/Heat Pump Convertible Air Handlers

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Cooling Capacity CFM in. w.c. (125 Pa)

Ruud Achiever Series Multi position Gas Furnaces

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

Cooling/Heat Pump Convertible Air Handlers

Wt. Lbs Model Number (BTUH) Hz

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Cooling Capacity CFM range

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

395CAV Sizes 045 thru 155 Series H and J

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Transcription:

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90 TUX2B060A9362A, TUX2B080A922A, TUX2C100A982A, TUX2D1A9602A, TDX2B060A9362A, TDX2B080A922A, TDX2C100A982A, TDX2D1A9602A Direct Vent with Variable Speed Inducer PUB. NO. 22-1705-08

General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./ Humidifier. AIR DELIVERY The four speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wraparound cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The XL90 High Efficiency Gas Furnaces employ an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. 11 Trane All Rights Reserved 2 Pub. No. 22-1705-08

Contents General Features Features and Benefits Standard Equipment Optional Equipment General Data TUX2B060A9362A TUX2B080A922A TUX2C100A982A TUX2D1A9602A TDX2B060A9362A TDX2B080A922A TDX2C100A982A TDX2D1A9602A Performance Data Venting Tables Electrical Data Field Wiring Twinning Field Wiring Dimensions 2 5 6-7 8-9 10-11 12-13 1-15 16-17 18-19 Pub. No. 22-1705-08 3

Features and Benefits XL 90 STANDARD EQUIPMENT Direct Drive - speed PSC Motor Silicon Nitride Igniter with adaptive heat up Variable speed induced draft blower Direct/Non-Direct vent option Fused 2 volt control circuit Manual reset burner safety switches Power supply Convertible to horizontal on left side 2-stage gas valve PVC venting-1 or 2 pipe option Accessory hook-up capability Integrated solid state control with self-diagnostics Attractive color accents Heavy gauge aluminized steel heat exchanger Multi-port In-shot burners Single wire twinning HInged blower door * Perfect fit door latches* Insulated blower door* Gasketed blower door* Internal filter rack* Standard filter sizes Two tone color Multi-port In-shot burners Complete front service access Left/right gas connection Adjustable fan off times Optional L.P conversion kit Selectable cooling fan off delay eliminates need for BAY2X05 time delay kit * (Upflow only) Pub. No. 22-1705-08

Features and Benefits XL 90 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling... TAYSTAT21 [ ] Thermostat, Electronic Programmable 2-Stage Heating...TAYSTAT302C [ ] Thermostat, Mechanical Heating Only With Fan Switch...TAYSTAT303C [ ] Thermostat, Heating/Cooling Single Stage (Mounts Horizontally)...AY28X092 [ ] Thermostat, Heating/Cooling Single Stage (Mounts Vertically)... BAYSTAT305 [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling...TAYSTAT300C [ ] Propane Conversion Kit... BAYLPKT210A [ ] Electronic Air Filter, Perfect Fit High Efficiency (1-1/2" Wide Gas Furnace)... TFM15A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (17-1/2" Wide Gas Furnace)... TFM175A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (21" Wide Gas Furnace)... TFM210A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (2-1/2" Wide Gas Furnace)... TFM25A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (1-1/2" Wide Gas Furnace)... TFP15A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (17-1/2" Wide Gas Furnace)... TFP175A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (21" Wide Gas Furnace)... TFP210A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (2-1/2" Wide Gas Furnace)... TFP25A9FR0 [ ] Coil Enclosure (1-1/2" Wide Cabinets)...BAYCLE1A122A [ ] Coil Enclosure (17-1/2" Wide Cabinets)...BAYCLE17A1722A [ ] Coil Enclosure (21" Wide Cabinets)...BAYCLE21A2130A [ ] Coil Enclosure (2-1/2" Wide Cabinets)...BAYCLE2A230A [ ] Downflow Subbase...BAYBASE5 [ ] Side Filter Rack... BAYFLTR0 [ ] Filter Kit/Horizontal Conversion TUX060,080-R... BAYFLTR3 [ ] Filter Kit/Horizontal Conversion TUX100-R... BAYFLTR [ ] Filter Kit/Horizontal Conversion TUX1-R... BAYFLTR5 [ ] Filter Accessory Kit... BAYFLTR317 [ ] Filter Accessory Kit... BAYFLTR321 [ ] Filter Accessory Kit... BAYFLTR32 [ ] High Altitude Pressure Switch Kit (TUX2B060, TDX2B060)... BAYHALT251 [ ] High Altitude Pressure Switch Kit (TUX2B080, TUX2C100, TDX2B080, TDX2C100)... BAYHALT261 [ ] High Altitude Pressure Switch Kit (TUX2D1, TDX2D1)... BAYHALT271 [ ] Concentric Vent Kit TUX Furnaces... BAYVENT100A [ ] Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces... BAYVENT0B [ ] Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces... BAYMFGH100A [ ] Filter Rack Kit... BAYRACK960A [ ] Cleanable Filter (1.5"/17.5" wide Upflow models)...bayfltr317 [ ] Cleanable Filter (21" wide Upflow models)... BAYFLTR321 [ ] Cleanable Filter (2.5" wide Upflow models)... BAYFLTR32 [ ] 1 Optional kit allows 0 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. Pub. No. 22-1705-08 5

General Data TUX2 PRODUCT SPECIFICATIONS1 MODEL TUX2B060A9362A TUX2B080A922A TUX2C100A982A TUX2D1A9602A RATINGS2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS)3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)3 AFUE (ICS) Temp. Rise (Min.-Max.) F. BLOWER DRIVE Dia.-Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts/Ph/Hz COMBUSTION FAN - TYPE Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz FL Amps FILTER Furnished? Type Recommended Filter (No.-Size-Thk.) VENT Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE DIRECT IGNITION DEVICE Type BURNERS Type Number POWER CONN. V/Ph/Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DUCT CONN. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.)/Net (Lbs.) 39000 36000 60000 56000 93.0 30-60 DIRECT 10 x 7 1 SEE FAN PERF. TABLE 1/3 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 1-17 X 25-1 IN 2 ROUND ALUMINIZED STEEL TYPE 1 3-5 3-56 REDUNDANT - TWO STAGE HOT SURFACE IN-SHOT 3 8.7 15 1/2 H X W X D 1-3/ X 19-1/2 X 30-1/2 158 / 16 500 8000 80000 73000 92.5 35-65 DIRECT 10 x 8 1 SEE FAN PERF. TABLE 1/3 1075 CENTRIFUGAL DIRECT - 1 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 1-17 X 25-1 IN 2 ROUND ALUMINIZED STEEL TYPE 1-5 - 56 REDUNDANT - TWO STAGE HOT SURFACE IN-SHOT 9.5 15 1/2 H X W X D 1-3/ X 19-1/2 X 30-1/2 168 / 156 65000 60000 100000 93000 93.0 35-65 DIRECT 10 x 10 1 SEE FAN PERF. TABLE 1/2 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 1 - X 25-1 IN 2 ROUND ALUMINIZED STEEL TYPE 1 5-5 5-56 REDUNDANT - TWO STAGE HOT SURFACE IN-SHOT 5 13.1 1/2 H X W X D 1-3/ X 23 X 30-1/2 197 / 185 700 66600 1000 1100 92.5 0-70 DIRECT 11 x 10 1 SEE FAN PERF. TABLE 3/ 1100 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 1-2 X 25-1 IN 3 ROUND ALUMINIZED STEEL TYPE 1 6-5 6-56 REDUNDANT - TWO STAGE HOT SURFACE IN-SHOT 6 13.5 1/2 H X W X D 1-3/ X 26-1/2 X 30-1/2 6 / 193 1 Central Furnace heating designs are certified to ANSI Z21.7 / CSA 2.3. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 22-1705-08

General Data TDX2 PRODUCT SPECIFICATIONS1 MODEL RATINGS2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS)3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS)3 AFUE (ICS) Temp. Rise (Min.-Max.) F. BLOWER DRIVE Dia.-Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts/Ph/Hz COMBUSTION FAN - TYPE Drive - No. Speeds Motor HP - RPM Volts/Ph/Hz FL Amps FILTER Furnished? Type Recommended Filter (No.-Size-Thk.) VENT Size (In.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE DIRECT IGNITION DEVICE Type BURNERS Type Number POWER CONN. V/Ph/Hz Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DUCT CONN. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.)/Net (Lbs.) TDX2B060A9362A 39000 36000 60000 55000 92.0 35-65 DIRECT 10 x 8 1 SEE FAN PERF. TABLE 1/3 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 2-1 X X 1 2 ROUND ALUMINIZED STEEL TYPE 1 3-5 3-56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN-SHOT 3 9.5 15 0.50 H X W X D 1-3/ X 19-1/2 X 30-1/2 160 / 15 TDX2B080A922A 500 8000 80000 7000 92.5 0-70 DIRECT 11 x 8 1 SEE FAN PERF. TABLE 1/2 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 2-1 X X 1 2 ROUND ALUMINIZED STEEL TYPE 1-5 - 56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN-SHOT 11.3 15 0.50 H X W X D 1-3/ X 19-1/2 X 30-1/2 168 / 158 TDX2C100A982A 65000 60000 100000 93000 93.0 5-75 DIRECT 11 x 10 1 SEE FAN PERF. TABLE 1/2 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 2-16 X X 1 2 ROUND ALUMINIZED STEEL TYPE 1 5-5 5-56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN-SHOT 5 13.1 0.50 H X W X D 1-3/ X 23 X 30-1/2 185 / 175 TDX2D1A9602A 78000 700 1000 111000 92.5 5-75 DIRECT 11 x 10 1 SEE FAN PERF. TABLE 3/ 1075 CENTRIFUGAL DIRECT - VARIABLE 1/15-5000 33-110/3/60-180 1.0 NO HIGH VELOCITY 2-16 X X 1 3 ROUND ALUMINIZED STEEL TYPE 1 6-5 6-56 REDUNDANT - TWO STAGE HOT SURFACE IGNITER IN-SHOT 6 13.5 0.50 H X W X D 1-3/ X 26-1/2 X 30-1/2 6 / 196 1 Central Furnace heating designs are certified to ANSI Z21.7 / CSA 2.3. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub. No. 22-1705-08 7

Upflow Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP 0.10 0. 0.30 0.0 0.50 0.60 0.70 0.80 0.90 *UX2B060A9362A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 139 1250 1102 957 1359 1232 1092 9 131 12 1069 922 1260 1160 103 891 1196 1106 986 853 1122 100 925 806 1038 962 852 750 95 873 766 686 853 771 668 61 *UX2B080A922A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 178 1375 1178 859 1683 1367 1167 863 1615 137 117 856 15 131 1119 839 170 1268 1082 811 1393 1210 1036 772 131 1139 982 723 1232 1056 919 663 117 960 87 592 *UX2C100A982A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 5 1932 1762 1558 1980 1875 17 156 1906 1818 1677 1533 1826 176 1615 177 176 1673 1552 121 169 1577 163 1350 1551 181 1373 1278 128 1371 1266 1175 1305 1260 1158 1071 *UX2D1A9602A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 25 2105 177 15 6 92 172 17 2358 78 1736 19 2310 5 17 10 2261 12 1703 130 218 1950 1677 100 2106 1887 1651 1369 17 1826 1593 1325 1928 1765 1535 1280 * - First letter may be "A" or "T" NOTE: See page 11 for factory heat & cool speed tap settings CFM VS. TEMPERATURE RISE MODEL Cubic Feet Per Minute (CFM) 900 1000 1100 10 1300 100 1500 1600 1700 1800 1900 00 2100 20 *UX2B060A9362A 56 50 5 2 39 36 *UX2B080A922A 61 56 51 8 2 *UX2C100A982A 6 60 56 52 9 6 2 *UX2D1A9602A 63 59 56 53 50 8 6 * - First letter may be "A" or "T" 8 Pub. No. 22-1705-08

Downflow Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.) MODEL SPEED TAP 0.10 0. 0.30 0.0 0.50 0.60 0.70 0.80 0.90 *DX2B060A9362A - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red 187 132 1181 877 125 1291 117 863 1362 1 1113 89 1286 1182 1061 8 19 112 1009 791 1125 107 93 739 100 989 877 686 935 869 779 612 830 769 681 537 *DX2B080A922A - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red 157 187 1388 1263 198 136 138 123 15 1382 1302 1196 1386 1325 129 1150 1323 1265 1191 1095 125 12 1126 1032 1180 1137 1056 960 1101 1069 979 879 1016 998 896 790 *DX2C100A982A - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red 1892 1779 1630 1 1827 1726 1587 116 1762 1672 15 1388 1688 1605 185 138 161 1538 126 1308 1531 160 1362 126 18 1381 1297 118 135 1291 18 1108 1260 10 1119 1032 *DX2D1A9602A - HIGH - Black 3 - MED.-HIGH - Blue 2 - MED.-LOW - Yellow 1 - LOW - Red 2213 57 1765 168 2138 00 1733 152 62 193 1700 135 01 1883 1652 109 1939 1822 1603 1382 1863 1752 1552 1336 1786 1681 1500 1290 1706 1595 12 1225 1625 1508 137 1159 *- First letter may be "A" or "T" CFM VS. TEMPERATURE RISE MODEL Cubic Feet Per Minute (CFM) 800 900 1000 1100 10 1300 100 1500 1600 1700 1800 1900 00 2100 20 2300 0 *DX2B060A9362A 63 56 51 6 2 39 36 3 *DX2B080A922A 68 61 56 52 8 5 2 0 *DX2C100A982A 65 60 56 53 50 7 2 0 38 37 35 *DX2D1A9602A 67 63 59 56 53 51 8 6 2 *- First letter may be "A" or "T" Pub. No. 22-1705-08 9

Maximum Vent Length Table VENT LENGTH TABLE ALTITUDE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NOTES) 0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH* PIPE *UX/ *DX2B060A9362A 0 0 0 *UX/ *DX2B080A922A 50 1 0 *UX/ *DX2C100A982A Not Allowed 60 0 *UX/ *DX2D1A9602A Not Allowed Not Allowed 0 7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE *UX/ *DX2B060A9362A 100 100 100 *UX/ *DX2B080A922A 25 60 100 *UX/ *DX2C100A982A Not Allowed 30 100 *UX/ *DX2D1A9602A Not Allowed Not Allowed 100 9,500-12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 INCH PIPE *UX/ *DX2B060A9362A 50 50 50 *UX/ *DX2B080A922A Not Allowed 30 50 *UX/ *DX2C100A982A Not Allowed Not Allowed 50 *UX/ *DX2D1A9602A Not Allowed Not Allowed 50 NOTES: * - First letter may be "A" or "T" 1. Minimum vent length for all models: 3' horizontal and vertical. 2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe. 3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).. One SHORT radius 90 elbow is equivalent to 10' of 3" pipe and one LONG radius elbow is equivalent to 6' of 3" pipe. One 90 elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 5 elbows equal one 90 elbow. 5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is used, the equivalent length of pipe is 5 feet. BAYVENT0B equivalent length is 0 feet. 6. Pipe adapters are field supplied (except 1). 10 Pub. No. 22-1705-08

Electrical Data *UX2 WIRING DIAGRAM From Dwg. D32781P01 Pub. No. 22-1705-08 11

Electrical Data *UX2 SCHEMATIC DIAGRAM From Dwg. D32782P01 12 Pub. No. 22-1705-08

*DX2 WIRING DIAGRAM Pub. No. 22-1705-08 13

*DX2 SCHEMATIC DIAGRAM 1 Pub. No. 22-1705-08

Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY Pub. No. 22-1705-08 15

Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) 16 Pub. No. 22-1705-08

Twinning Field Wiring Pub. No. 22-1705-08 17

Twinning Field Wiring 18 Pub. No. 22-1705-08

Dimensions From Dwg. 21C3188 Rev. 1 *UX2 UPFLOW / HORIZONTAL OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) Model (See Note 1 & 2) DIM "A" DIM "B" DIM "C" DIM "D" DIM "E" DIM "F" *UX2B060A9362A *UX2B080A922A 17-1/2" 2-1/" 16-1/" 16" 7-1/2" 2" *UX2C100A982A 21" 2-1/2" 19-3/" 19-1/2" 9" 3" *UX2D1A9602A 2-1/2" 2-15/16" 23-1/" 23" 10" 3" * Prefix May Be "A" or "T" Notes: 1. *UX2D1A9602A Requires 3" Diameter Vent Pipe. *UX2C100A982A Requires 2-1/2" or 3" Diameter Vent Pipe. 2. Diameter of Vent PIpe may be limited to 2-1/2" or 3" on some models at different altitudes. Refer to the Vent Length Table for proper application. Pub. No. 22-1705-08 19

*DX2 DOWNFLOW / HORIZONTAL OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) Model (See Note 1) DIM "A" DIM "B" DIM "C" DIM "D" *DX2B060A9362A *DX2B080A922A 17-1/2" 2-1/" 16-1/" 16" *DX2C100A982A 21" 2-1/2" 19-3/" 19-1/2" *DX2D1A9602A 2-1/2" 2-15/16" 23-1/" 23" From Dwg. 21C31885 Rev. 1 * Prefix May Be "A" or "T" Notes: 1. Diameter of Vent Pipe may be limited to 2-1/2" or 3" on some models at different altitudes. Refer to the Vent Length Table for proper application. Pub. No. 22-1705-08

Notes Pub. No. 22-1705-08 21

Trane 60 Troup Highway Tyler, TX 75707 www.trane.com Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.