Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Similar documents
Modular Multi-position Air Handler

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Cooling/Heat Pump Convertible Air Handlers

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Cooling/Heat Pump Convertible Air Handlers

Product Data. Convertible Air Handlers 1 1/2 5Ton

Variable Speed Convertible Air Handler 5 Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Cooling/Heat Pump Convertible Air Handlers

Variable Speed Convertible Air Handler 4 Ton

Vertical Upflow Horizontal Left Air Handlers

Variable Speed Convertible Air Handler 2 1/2 Ton

Hyperion TM Split Systems

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

36,000-62,000 BTUH Nominal Capacity

Multi-position Air Handler

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Hyperion Field Reference Data TAM8

4YCC3048A3096A /3/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Upflow/Horizontal Condensing, Gas-Fired Furnace

Note: A/TZONE 950/850 communicating thermostats MUST be used for Variable Speed Outdoor units.

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Advance Release September 2009

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Downflow/Horizontal Right Induced Draft Gas Furnace

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

HIGH EFFICIENCY AIR HANDLER

HIGH EFFICIENCY AIR HANDLER

PAJ3. Product Specifications

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

AIR HANDLERS AIR HANDLERS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Split System Cooling Product & Performance Data

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Bosch BVA Series Air Handler

SEER 1½

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Rheem Standard Efficiency Air Handler

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Ruud Standard Efficiency Air Handler

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

MERIT Series R-410A - Upflow / Horizontal

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Standard Efficiency Air Handler

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

MERIT Series R-410A - Upflow / Horizontal

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:


Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

TECHNICAL SPECIFICATIONS B6VMMX

Transcription:

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE GAF2A0A24S21SE GAF2A0A24S21EE GAF2A0A30S21SE GAF2A0A30S21EE GAF2A0A36S31SE GAF2A0A36S31EE PUB. NO. 12-1317-10

Features and Benefits Unique Cabinet Design - Double Wall Foamed and Formed Cabinet System - Water Proof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Cabinet Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage - Precision Applied Durable Door Seals Multi-Position Upflow/ Horizontal Left / Horizontal Right Front Return Option Braze in Refrigerant Connection Primary/Secondary Condensate Connections Vortica Blower with Integrated Slide Deck for Easy Removal Polarized Plug connections on Blower Aluminum Coil with Integrated Slide Deck for Easy Removal Slide in Electric s Polarized Plug connections for Electric Labeled Panels and connections Guide for 1-1/4" to 1" And 3/4" to 1/2" Conduit connection on Top R-410A Thermal Expansion Valve (TXV) Convertible to R-22 using optional accessory TXV conversion kit. Low Voltage Color Coded Wires Enhanced Coil Fin Patented Blow Through Design PSC 3 Speed Motor Maximum Width of 17.5" Compact 20.8" depth with doors removed Integrated Horizontal Drain pans Single Color Fused 24V Power 5 year warranty 10-year warranty registered Optional extended warranty available 2016 American Standard Heating & Air Conditioning 2 Pub. No. 12-1317-10

Contents Features and Benefits 2 Optional Equipment 4 Unique Cabinet Design Features and Benefits 5 General Data 6 GAF2A0A18S11EE, GAF2A0A18S11SE 6 GAF2A0A24S21EE, GAF2A0A24S21SE 6 GAF2A0A30S21EE, GAF2A0A30S21SE 6 GAF2A0A36S31EE, GAF2A0A36S31SE 6 Performance Data 7 Electrical Data 11 Wiring Diagrams 13 Field Wiring 14 Convertibility 16 Dimensions 17 Pub. No. 12-1317-10 3

Optional Equipment OPTIONAL EQUIPMENT FOR GAF2 AIR HANDLERS Accessory Number Description Fits Cabinet Size BAYECAA05LG1 Electric, 5kW, Lugs, 24V Control, 1 Ph A BAYECAA08LG1 Electric, 8kW, Lugs, 24V Control, 1 Ph A BAYECAA10LG1 Electric, 10kW, Lugs, 24V Control, 1 Ph A BAYSFSCABAA Supply Duct Flange A1 1 A1 1 BAYRETFLGAA Return Duct Flange A A TASB175SB Plenum Stand with Sound Baffle A A BAYFRKIT100 3 Front Return Kit A BAYBRFBX100 2 Bottom Return Filter Box A BAYWMKIT001 Wall Mount Kit A BAYLVKIT100A Low Voltage Conduit Entry Kit A BAYAHTXV1836 R-22 TXV Conversion Kit A BAYSRKIT100A Side Return Kit A MITISRKIT1620 2 Side Return Kit with 16 x 20 Filter A BAYFLR1620A High Velocity Filter Kit, 16 X 20 X 1 (10 filters) A TASSBK175 Sound Baffle Kit 17.5 Cabinet A 1 GAF2A0A18-36 Cabinet is one piece 17.5 wide 2 Uses 16" x 20" filter 3 Uses 16" x 16" filter 4 Pub. No. 12-1317-10

Unique Cabinet Design Features and Benefits 2 Precision Durable Door Seals 1 Unique Cabinet Design 5 Conduit Connection Location r Integrated Horizontal Drain Pans 9 All Aluminum Coil q Thermal Expansion Valve (TXV) 3 Refrigeration Connections 4 Condensate Connections 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck 0 Labeled Panels and Connections w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed 1 Unique Cabinet Design - Double wall foamed cabinet system - Waterproof Cabinet Design - R-4.2 Insulating Value (Avg. Insulating Value R-8) - Composite Foamed Cabinet Doors - Sweat Eliminating Cabinet Design - Loose Fiber Eliminating Design - Smooth Cleanable Cabinet Design - 2% or Less air leakage 2 Precision Durable Door Seals 3 Brazed Refrigeration Connections 4 Primary/Secondary Condensate Connections 5 Conduit Connection - Conduit Connection on Top 7 PSC 3 Speed Motor 8 Vortica TM Blower and Deck - Polarized Plug on Blower 9 All Aluminum Coil - Integrated Slide Deck for Easy Removal - Polarized Plug connections on Coil TXV - Patented Enhanced Coil Fin 0 Labeled Panels and Connections q R-410A Thermal Expansion Valve (TXV) w Maximum width is 17.5 e Compact 20.8 Depth with Doors Removed r Integrated Horizontal Drain Pans Pub. No. 12-1317-10 5

General Data MODEL RATED VOLTS/PH/HZ. RATINGS 1 INDOOR COIL Type Rows F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) 2 DUCT CONNECTIONS INDOOR FAN Type Diameter-Width (In.) No. Used Drive - No. Speeds CFM vs. in. w.g. No. Motors H.P. Motor Speed RPM Volts/Ph/Hz F.L. Amps - L.R. Amps FILTER Filter Furnished? Type Recommended No.-Size-Thickness REFRIGERANT Ref. Line Connections Coupling or Conn. Size in. Gas Coupling or Conn. Size in. Liq. DIMENSIONS Crated (In.) Uncrated WEIGHT Shipping (Lbs.) / Net (Lbs.) GAF2A0A18S11EE GAF2A0A18S11SE 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/3 825 208-230/1/60 2.0-4.1 No Throwaway 1-16 X 20-1 in. R-410A 3 Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 117/107 PRODUCT SPECIFICATIONS GAF2A0A24S21EE GAF2A0A24S21SE 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/4 1075 208-230/1/60 1.3-2.6 No Throwaway 1-16 X 20-1 in. R-410A 3 Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 120/110 GAF2A0A30S21EE GAF2A0A30S21SE 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 10 X 8 1 Direct - 3 See Fan Performance Table 1-1/3 1075 208-230/1/60 1.7-3.5 No Throwaway 1-16 X 20-1 in. R-410A 3 Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 121/111 GAF2A0A36S31EE GAF2A0A36S31SE 208-230/1/60 See O.D. Specifications Plate Fin 3-14 3.21 3/8 TXV 3/4 NPT See Outline Drawing Centrifugal 11 X 8 1 Direct - 3 See Fan Performance Table 1-1/2 1075 208-230/1/60 2.4-3.8 No Throwaway 1-16 X 20-1 in. R-410A 3 Brazed 3/4 3/8 H x W x D 40.5 x 20 x 24.5 39.5 x 17.5 x 21.8 122/112 1 These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76) 3 R-22 requires TXV change. Use R-22 TXV conversion kit BAYATXV1836A. 6 Pub. No. 12-1317-10

General Data EXTERNAL STATIC (in w.g) GAF2A0A18 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A18S11 Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 952 768 710 940 654 598 0.1 894 741 687 885 636 581 0.2 845 704 658 831 610 558 0.3 785 662 620 775 577 526 0.4 724 607 568 714 529 477 0.5 652 531 494 640 460 415 0.6 557 441 404 543 378 347 0.7 428 346 N/A 418 244 N/A 0.8 284 N/A N/A 225 N/A N/A 0.9 N/A N/A N/A N/A N/A N/A 1.0 N/A N/A N/A N/A N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A18S11 MINIMUM HEATER AIRFLOW CFM Without Heat Pump Minimum Air Speed Tap With Heat Pump BAYECAA05LG1 Tap 1 Tap 3 BAYECAA08LG1 Tap 2 Tap 3 BAYECAA10LG1 Tap 2 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. Pub. No. 12-1317-10 7

Performance Data EXTERNAL STATIC (in w.g) GAF2A0A24 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A24S21 Speed Taps - 230 VOLTS AIRFLOW (CFM) Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 998 848 771 899 737 658 0.1 949 816 745 868 710 630 0.2 911 784 711 834 683 602 0.3 869 750 679 794 650 567 0.4 825 708 638 756 611 524 0.5 772 659 586 704 547 476 0.6 707 591 518 641 499 415 0.7 614 513 444 555 420 346 0.8 533 416 356 465 339 268 0.9 413 309 218 351 203 138 1.0 241 130 N/A 167 N/A N/A NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A24S21 MINIMUM HEATER AIRFLOW CFM Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1 Tap 1 Tap 2 BAYECAA08LG1 Tap 2 Tap 3 BAYECAA10LG1 Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 8 Pub. No. 12-1317-10

Performance Data EXTERNAL STATIC (in w.g) GAF2A0A30 AIRFLOW PERFORMANCE TABLE AIRFLOW PERFORMANCE GAF2A0A30S21 Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1052 967 932 1024 877 826 0.1 1012 929 898 980 846 800 0.2 963 888 861 934 814 771 0.3 914 849 823 885 777 738 0.4 865 805 784 837 739 703 0.5 816 759 741 788 697 663 0.6 759 698 681 739 640 602 0.7 690 622 592 668 559 515 0.8 589 503 463 559 423 395 0.9 389 336 318 375 285 259 1.0 179 149 119 175 NA NA NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A30S21 MINIMUM HEATER AIRFLOW CFM Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1 Tap 1 Tap 1 BAYECAA08LG1 Tap 2 Tap 2 BAYECAA10LG1 Tap 1 Tap 3 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. Pub. No. 12-1317-10 9

Performance Data GAF2A0A36 AIRFLOW PERFORMANCE TABLE EXTERNAL STATIC (in w.g) AIRFLOW PERFORMANCE GAF2A0A36S31 Speed Taps - 230 VOLTS Speed Taps - 208 VOLTS 3 2 1 3 2 1 0 1191 1146 1094 1040 1015 964 0.1 1180 1132 1085 1033 1004 959 0.2 1158 1110 1065 1014 984 942 0.3 1119 1082 1035 979 958 916 0.4 1079 1045 1003 942 923 887 0.5 1040 1005 969 907 886 857 0.6 993 960 927 864 843 818 0.7 934 910 877 808 795 772 0.8 880 855 816 758 742 715 0.9 815 786 748 696 675 650 1.0 744 715 677 629 607 583 NOTES: 1. Values are with wet coil and without filters. 2. Contact your particular filter manufacturer for pressure drop data. 3. Electric heater pressure drop is negligible and is included within the airflow data. 4. Factory Setting GAF2A0A36S31 MINIMUM HEATER AIRFLOW CFM Minimum Air Speed Tap Without Heat Pump With Heat Pump BAYECAA05LG1 Tap 1 Tap 1 BAYECAA08LG1 Tap 1 Tap 1 BAYECAA10LG1 Tap 1 Tap 1 SEE AIR HANDLER NAMEPLATE OR PRODUCT DATA FOR EXCEPTIONS Note: Heating and cooling speeds are the same, factory set at Speed Tap #2. 10 Pub. No. 12-1317-10

Electrical Data Model No. No. of s Capacity Amps per WIRING DATA GAF2A0A18S11 240 VOLT 208 VOLT Minimum Ampacity Maximum Overload Protection Capacity kw BTUH kw BTUH Amps per Minimum Ampacity Maximum Overload Protection No - - - 2.0** 3 15 - - 2.0** 3 15 BAYECAA05++ 1 4.80 16400 20 28 30 3.60 12300 17.3 24 25 BAYECAA08++ 1 7.68 26200 32 43 45 5.76 19700 27.7 37 40 BAYECAA10++ 1 9.60 32800 40 53 60 7.20 24600 34.6 46 50 Note: ** Motor Amps Model No. No. of s Capacity Amps per WIRING DATA GAF2A0A24S21 240 VOLT 208 VOLT Minimum Ampacity Maximum Overload Protection Capacity kw BTUH kw BTUH Amps per Minimum Ampacity Maximum Overload Protection No - - - 1.3** 2 15 - - 1.3** 2 15 BAYECAA05++ 1 4.80 16400 20 27 30 3.60 12300 17.3 23 25 BAYECAA08++ 1 7.68 26200 32 42 45 5.76 19700 27.7 38 40 BAYECAA10++ 1 9.60 32800 40 52 60 7.20 24600 34.6 45 45 Note: ** Motor Amps Model No. No. of s Capacity Amps per WIRING DATA GAF2A0A30S21 240 VOLT 208 VOLT Minimum Ampacity Maximum Overload Protection Capacity kw BTUH kw BTUH Amps per Minimum Ampacity Maximum Overload Protection No - - - 1.7** 2 15 - - 1.7** 2 15 BAYECAA05++ 1 4.80 16400 20 27 30 3.60 12300 17.3 24 25 BAYECAA08++ 1 7.68 26200 32 42 45 5.76 19700 27.7 38 40 BAYECAA10++ 1 9.60 32800 40 52 60 7.20 24600 34.6 45 45 Note: ** Motor Amps Pub. No. 12-1317-10 11

Electrical Data Model No. No. of s Capacity Amps per WIRING DATA GAF2A0A36S31 240 VOLT 208 VOLT Minimum Ampacity Maximum Overload Protection Capacity kw BTUH kw BTUH Amps per Minimum Ampacity Maximum Overload Protection No - - - 2.4** 3 15 - - 2.4** 3 15 BAYECAA05++ 1 4.80 16400 20 28 30 3.60 12300 17.3 25 25 BAYECAA08++ 1 7.68 26200 32 43 45 5.76 19700 27.7 38 40 BAYECAA10++ 1 9.60 32800 40 53 60 7.20 24600 34.6 46 50 Note: ** Motor Amps DISTANCE FROM BELLY BAND TO SHAFT FACE OF MOTOR FOR MINIMUM VIBRATION BLOWER HOUSING BELLY BAND A MOTOR MODEL DIM "A" GAF2A0A18S11 1-1/8 GAF2A0A24S21 2-11/16 GAF2A0A30S21 1-9/16 GAF2A0A36S31 1-11/16 WHEEL A is determined per chart Wheel is centered in Blower Housing 12 Pub. No. 12-1317-10

WIRING DIAGRAM FOR GAF2A0A18S, GAF2A0A24S, GAF2A0A30S, AND GAF2A0A36S AIR HANDLERS Pub. No. 12-1317-10 13

Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED COOLING Air Handler Hook-up Diagram Cooling W1 White Green Red Blue Comfort Control Air Handler Air Conditioner White Green Yellow Orange Red Blue W G Y O R B White Green Yellow Red Blue B - Blue Y - Yellow Blue Yellow Field wiring 14 Pub. No. 12-1317-10

Field Wiring GAF2 AIR HANDLERS WITH SINGLE SPEED HEAT PUMP Air Handler Hook-up Diagram HP Heat Pump W1 White Green Red Blue Air Handler Black (X2) Yellow White Green Yellow Orange Red Blue Comfort Control W G Y O R B White Green Yellow Orange Red Blue R - Red B - Blue Y - Yellow Orange Red Blue Field wiring Pub. No. 12-1317-10 15

GAF2 Convertibility * Note: No internal modifications required for any position. 1 Badge rotation will keep brand in correct position Multi-position Air Handler Refrigerant Connections Low Voltage Connections inside unit Upflow Configuration 1 Upflow Condensate Drains Airflow Refrigerant Connections Low Voltage Connections inside unit Refrigerant Connections 1 Airflow Airflow 1 Horizontal Left Condensate Drains Low Voltage Connections inside unit Horizontal Right Condensate Drains Horizontal Left* Horizontal Right* 16 Pub. No. 12-1317-10

Dimensions GAF2 AIR HANDLER DIMENSIONAL DATA W H D Model Number H x D x W in. Unit Net Weight lbs. GAF2A0A18S11 39 x 22 x 17.5 107 GAF2A0A24S21 39 x 22 x 17.5 110 GAF2A0A30S21 39 x 22 x 17.5 111 GAF2A0A36S31 39 x 22 x 17.5 112 GAF2 AIR HANDLERS ARE ALL ONE PIECE CABINETS. Pub. No. 12-1317-10 17

GAF2 OUTLINE DRAWING 18 Pub. No. 12-1317-10

Pub. No. 12-1317-10 19

03/16 American Standard Heating & Air Conditioning 6200 Troup Highway Tyler, TX 75707 www.americanstandardair.com The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.