Flexible Gas Piping - Evolving Technology & Industry

Similar documents
FLEXIBLE GAS PIPING CSST: INSIDE AND OUT

Flexible Gas Piping by OmegaFlex

Yellow Corrugated Stainless Steel Tubing (CSST) Questions and Considerations

Electrical Protection of CSST Gas Piping Systems. Bob Torbin, PE Omega Flex, Inc.

Bonding Requirements For Gas Piping Systems

CSST Installation Requirements in the Fuel Gas Codes

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

2015 National Fuel Gas Code Summary List of Revisions Updated: 04/24/14

2018 National Fuel Gas Code Summary List of Revisions Updated: 7/27/17

FACT SHEET 2018 National Fuel Gas Code Summary List of Revisions rev

DESIGN AND INSTALLATION GUIDE. Commercial I Industrial I Residential. SEPTEMBER 2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Design and Installation Guide

Electrical Grounding For Oil and Gas Applications

FIRE AND MATERIALS 2005

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

NFPA 54 UPDATE. Paul Cabot American Gas Association

CSST Flexible Gas Pipe. System Design and Installation Manual

ASC Z223 SECOND PUBLIC REVIEW DRAFT

Analysis of Changes for the 5 th Edition (2014) of the Florida Codes

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

CSST Flexible Gas Pipe. System Design and Installation Manual

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

DESIGN AND INSTALLATION GUIDE

Educational Course Application

PART GENERAL 1.01 SECTION INCLUDES

Re: Energy Conservation Standards for Residential Boilers; Proposed Rule Docket Number EERE-2012-BT-STD-0047

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

THE HARD WATER WATER HEATER

Handling Petroleum Products & Static Ignition Hazards Introduction

2015 IRC Significant Changes For Mechanical and Fuel Gas with LSUCCC Amendments

Comparison of IEEE 323 and IEC Shows Notable Consistency (cont)

ASABE and International Standardization: A Decade of Harmonization and Collaboration

Design and Installation Guide

Curriculum Vitae - Gregory W. Miller, P.E. June Miller Engineering Services 2205 Barnett Dr. Cedar Park, TX 78613

Commercial Industrial Residential DESIGN & INSTALLATION GUIDE. November 2008

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Mechanical Appliance and Equipment Inspection Checklist

The following preprint is based on the First Revision Draft of the 2018 edition of NFPA 54/Z223.1.

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

DESIGN AND INSTALLATION GUIDE

REPORT* OF THE MOTIONS COMMITTEE 2017 NFPA TECHNICAL MEETING JUNE 7, 2017 BOSTON, MA

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

nimbus new ESE LIGHTNING ROD NF C :2011 standard Designed and tested in full accordance with the new

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

DESIGN INSTALLATION GUIDE COMMERCIAL INDUSTRIAL RESIDENTIAL. NOVEMBER

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

EVALUATION RISK ACCORDING UNE :2 / UNE 21186:2011 / NFC :2011 SELECTION OF PROTECTIVE MEASURES AGAINST LIGHTNING

2012 ICC Code Development Hearings 2012 Code Development Cycle:

At its meeting of August 7-9, 2012, the Standards Council considered the above referenced matter.

Pellet Vent INSTALLATION INSTRUCTIONS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Status Report of the SPE Oil and Gas Reserves Committee Where Is Our Focus?

NATURAL GAS PIPING

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

2012 Virginia Residential Fuel Gas Code & 2012 International Fuel Gas Code Update Training

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

940ES Tankless Water Heater

GPS 140 NEC Requirements for Generators. Professional Development Seminar Series NEC Requirements for Generators

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

XRRS Specification Fire Ready Hood

for combining TwO gas furnaces for PARAllel OPeRATIONs using The Rccl-cOIl (heating ANd AIR conditioning)

BDM Direct Vent systems are for use with direct vent gas fired appliances.

U.S. Codes & Standards for Energy Storage Systems. Joe Cain, P.E. Chair, SEIA Codes & Standards Working Group

940ES Tankless Water Heater

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

INFORMATION FOR TANKLESS WATER HEATERS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

"ESDDR" Series Electric Humidifier

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

A Pipe as Versatile and Flexible as Your Business

Leading Trends in Chemical Processing

SECTION AUTOMATIC TRANSFER SWITCHES

Electrical Product Pathfinder Group Electric kettles

Innovation for prevention, safety and protection against lightning

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

Navigating The Product Certification Maze: Building Codes and Product Standards. AGENDA be Covered

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Electrical Protection and Transportation Installations for Non-domestic Buildings

Neil Hewitt Electrical & Air Conditioning P/L

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

... with Knowledge Solutions Lightning Protection Standards

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

TANKLESS WATER HEATING

Transcription:

Flexible Gas Piping - Evolving Technology & Industry NARUC Annual Meeting Austin, Texas November 8, 2015

Flexible Gas Piping Corrugated Stainless Steel Tubing (CSST) Flexible Continuous lengths Jacketed Yellow CSST - insulative Black CSSTs arc protective designs Fittings Field attachable Transition to NPT

ANSI Performance Standard - Fuel Gas Piping Systems Using CSST 1983 GRI Residential Gas Piping Program Innovative piping systems Gas competiveness Japanese technology AGA 1-87 Requirements for CSST ANSI LC 1-1991 Harmonized w/ CSA in 1997 ANSI LC 1 /CSA 6.26 2014

CSST Benefits ~ 75% fewer joints than rigid Productivity Seismic/settling Gas competiveness w/ electric Increased gas utilization

Industry Lightning Experience 2003 Frisco, TX 2006 Class action enhanced warnings 2009 NFPA 54 direct bond 2013 GTI report, Bonding Effectiveness 2015 NFPA 54-2018 Public Inputs

Industry Safeguards Yellow CSST Installation Safeguards Direct-bond Separation Chase Exclusion Protective Jacketed CSST ICC-ES PMG listing criteria LC1024 (2010) LC1027 (2011)

Lightning Test for Protective Jacketed CSST Accredited lightning testing laboratory Lightning generator delivers defined charge to sample Test Charge & Waveform Lightning Generator Electrode CSST Test Sample Ground

Lightning Tests and Listings Utilized by the CSST Industry ICC-ES PMG Listing Criteria Parameter LC1024 LC1027 Test Charge (Coulombs) 4.5 C 36 C Min. Peak Current (Amps) 1,000 A 30,000 A Test Charge Basis Assumption of 2 coulomb maximum transient arcing energy w/in building 50 th percentile of negative lightning flashes measured @ ground * * Informed from SAE ARP5412B Aerospace Recommended Practice, Aircraft Lightning Environment and Related Test Waveforms

Lightning

Occurrence Lightning Strikes Magnitude and Frequency Negative Flash to Ground Parameter: Cumulative Charge Transfer 50 th Percentile 50% 50% 0 36 100+ Cumulative Charge Transfer (Coulombs) Informed from SEA ARP5412B Aerospace Recommended Practice, Aircraft Lightning Environment and Related Test Waveforms Distribution model

Industry Tests for Protective Jacketed CSST Sec. 4.4.2. Indirect Effects 2, Represent 50 th percentile of negative lightning flashes measured at ground LC1027-Lubbock FGS - Lubbock, TX, Fuel Gas Subcommittee and city staff, minimum CSST arc resistance requirement, 8/26/15. 1

LC1024-listed CSST Single Layer Conductive Jacketed CSST Semi-conductive polymer layer Spread and dissipate energy 4.5 Coulomb test Black jacket

LC1027-listed CSST Metallically Shielded CSST Multi-layer Metallic shield between polymer layers Shield-to-fitting electrical continuity Spread and dissipate energy 36 Coulomb test Black Jacket

Industry Reports and Articles Whitepaper (Titeflex) Comparison of Listing Criteria for Protective-Jacketed CSST APGA Source Emerging CSST Products Feature article, July 2015

Recent National Press Lawyers, Lightning and Building Codes Public safety Role of litigation in product development Buddy Holly s Hometown Unlikely Pioneer with Lightning and CSST Lubbock, TX, minimum requirement for LC1027-rated CSST

ANSI LC 1 CSST Performance Standard Fuel Gas Piping System Using CSST Yellow CSST performance requirements Since 1991 Sec. 5.16 Arc resistant jacket (optional) Since 2014 4.5 Coulomb (C) electrical arcing test Extreme temperature Resistance to corrosion Resistance to installation damage

ANSI LC 1 CSST Performance Standard Recent proposals to ANSI LC 1 performance standard Increase 4.5 C electrical arcing test to 36 C Test in direct contact Add low voltage withstand Proposals have moved to working groups CSA process and maintenance Working groups open to outside experts

Public Inputs to NFPA 54-2018 22 Public CSST Comments 16 Restrictive LC1027 minimum, protective jacket Direct-bonding limits 50-ft max. bond wire length Clamp location 6 separation req t Metal studs exclusion Provide ground fault current path Single layer conductive jacketed Yellow jacket

NFPA 54-2018 Can the NFPA 54 Technical Committee rely on higher CSST performance levels into the ANSI LC 1? Gas Associations support for improvements? ANSI LC 1 Test Area Electrical Arcing Withstand Electrode to Test Sample Low Voltage Withstand 2014 LC 1 Proposals @ Working Group 4.5 C 36 C 1/8 air gap Contact with sample No Test Add test for residential current fault

A CSST Future More robust performance standard Lightning resistance Low voltage withstand Metallically Shielded or equivalent performing CSST Installation productivity Joint reduction Seismic performance Greater reliability

Thank you