Operating Functions Temperature Parameters

Similar documents
BTU Units WORKING PROGRAM MANUAL

WORKING PROGRAM. Heating dehumidifying cooling T 27

Wired Controller XK60

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Table 1. Serie of Digital Room Thermostats.

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

REMOTE CONTROL MANUAL

USER'S OPERATING INSTRUCTIONS

Owner s Manual TABLE OF CONTENTS

Ductless Split Air Conditioner

Buttons on remote controller

VMI-1102-A SERVICE MANUAL AIRCONDITIONER DC INVERTER MULTI TYPE MSV1I-09HRDN1-M TAS-09MVHN TAS-12MVHN INDOOR VERTU DC INVERTER MULTI SERIES

OPERATING INSTRUCTIONS

Technicians Manual Single Compressor

Ductless Split Air Conditioner

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

C&H NORDIC Commercial 4 SERVICE MANUAL

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

SERVICE MANUAL REFRIGERATION

Remote Controller Manual

Portable Air Conditioner Instruction Manual

Service Manual. Cutee Serie. Please be aware that all product codes beginning with GPC are to be seen as the TOSOT units beginning with TPC.

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

Owner s Manual TABLE OF CONTENTS

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

1 Summary and features. Service Manual. Model QSVMI-09A QSVMI-12A QSVMI-18A

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

PDA20DX Air Purifying Dehumdifier Manual

4. ALIGNMENT AND ADJUSTMENTS

DVC/DVH 09/12/18/24 Series

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Slim Line Ceiling Concealed Ducted Split Systems

CONTROL PANEL INSTRUCTIONS RSQ-4

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

Owner's Manual. Owner's Manual. Air Conditioners

INSTALLATION AND USER MANUAL

OWNER S MANUAL VMH 09/12/18/24

High Wall Split Air Conditioners 53QHCT KHCT

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Wall Mounted Mini Split Heat Pump Air Conditioner

Air conditioner. User manual. Wireless Remote Control AR-EC03E/EH03E/EC03M/EH03M. English 1

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

TREO SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

Hi Wall Split Air Conditioners

Hi - Wall Split Systems 12K - 18K - 24K

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

REMOTE CONTROL MANUAL

SAT-3 Room Temperature Controller

OWNER S MANUAL DUCTED INVERTER. (English) (SDHV SERIES)

SERVICE MANUAL REFRIGERATION

SYSCONTROL RM 52. SYSPLIT Type Remote controller user manual CR090 RG52A A

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Ewpe Smart. Wi-Fi management software

PORTABLE AIR CONDITIONER

GREE+ APP AND UNIVERSAL WIFI INSTALLATION AND OPERATION MANUAL

OPERATING MANUAL. Before using your air conditioner, please read this operating manual carefully and keep it for future reference.

40KMC KMQ

Neo DUCTLESS SYSTEM Installation, Service & Troubleshooting

REMOTE CONTROLLER OWNER S MANUAL

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Service Manual & Installation Manual

SERVICE MANUAL REFRIGERATION

SPLIT-TYPE ROOM AIR CONDITIONER

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

PORTABLE AIR CONDITIONER

Floor-Standing Type(E Series)

13SEER DC INVERTER 24K

15,000 BTU Portable Air Conditioner

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

Remote Control Features & Functions

Portable Air Conditioner USER MANUAL

REMOTE CONTROLLER CR057-RG51Q&J MANUAL

Owner s Manual Super-Slim Four-Way Cassette

INSTALLATION AND USER MANUAL

Owner s Manual TABLE OF CONTENTS

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Owner s Manual TABLE OF CONTENTS

Transcription:

Operating Functions

Temperature Parameters Room set temperature (T set) Room ambient temperature (T amb)

Fundamental Functions After powered on, no matter when the compressor is started, the time interval between two startups cannot be less than 3 minutes.

Fundamental Functions COOL Mode The condition and process of cooling If the indoor ambient temperature is equal to or greater than the room set temperature, COOL mode will act, the compressor and outdoor fan will run, and the indoor fan will run at the set speed. If the indoor ambient temperature is equal to or lower than 2 F below the room set temperature, the compressor will stop, the outdoor fan will delay 30 seconds to stop, and the indoor fan will run at the set speed. If the indoor ambient temperature is lower than the room set temperature, yet higher than 2 F below the room set temperature, the unit will keep running in the previous mode. In this mode, the reversal valve will not be powered on and the temperature setting range is 61 F ~ 86 F. The unit will adjust the running frequency of the compressor automatically according to the change of ambient temperature.

Fundamental Functions COOL Mode Anti-freezing protection 1) Under cooling or dehumidify mode, if T indoor tube senor has detect a temperature that is below 32 F continuously for 3 minutes, the unit will go into freeze protection mode and shut down. Once the unit shut down because of freeze protection, the unit will not restart until T indoor tube sensor is above 42.8 F. The compressor has to wait at least 3 minutes to restart after shutting down due to freeze protection. 2) Under cooling or dehumidify mode, if T indoor tube senor has detected a temperature that is below 42.8 F but higher than 32 F, the compressor may decrease its speed to prevent the temperature to go below 32 F. 3) If the unit has been shut down six times because of the freeze protection, it will not restart again automatically. Instead, user or service technician needs to completely power off the unit before he/she can try to restart the unit manually. But, once the compressor runs continuously for more than 10 minutes normally (no freeze protection detected), the number of freeze protections will be cleared to zero.

Fundamental Functions COOL Mode Overcurrent protection If total current is high, the compressor will run in limited or dropped frequency. When total current goes on rising over the stated value, the compressor will stop, the outdoor fan will delay 30 seconds, then stop.

Fundamental Functions DRY Mode The condition and process of drying If the indoor ambient temperature is greater than the room set temperature, DRY mode will act, the indoor fan, outdoor fan and compressor will run, and indoor fan will run at low speed. If the indoor ambient temperature is lower than the room set temperature, yet higher than 2 F below the room set temperature, the unit will keep running in the original mode. If the room ambient temperature is lower than 2 F below the room set temperature, the compressor will stop running, the outdoor fan will delay 30 seconds to stop and the indoor fan will run at low speed. In this mode, the reversal valve will not be powered on and the temperature setting range is 61 F ~ 86 F. The unit will adjust the running frequency of the compressor automatically according to the change of ambient temperature.

Fundamental Functions DRY Mode Protection Protection is the same with that in COOL mode.

Fundamental Functions HEAT Mode The condition and process of heating If the indoor ambient temperature is equal to or less than 2 F above room set temperature, HEAT mode will act, the compressor, outdoor fan and 4-way valve will run simultaneously, and the indoor fan will delay up to 2 minutes before running. If the indoor ambient temperature is lower than 9 F above room set temperature, yet higher than 2 F above room set temperature, the unit will keep running in the original mode. If the indoor ambient temperature is greater than 9 F above room set temperature, the compressor will stop, the outdoor fan will delay 30 seconds then stop, and the indoor fan will blow for 60 seconds at the original speed and then stop. In this mode, the temperature setting range is 61 F ~ 86 F. The air conditioner will adjust the running frequency of the compressor automatically according to the change of ambient temperature. When the unit is turned off in HEAT mode, or switched to another mode, the 4-way valve will be powered off 2 minutes after the compressor stops.

Fundamental Functions HEAT Mode The condition and process of defrosting What parameters have been used in the defrost algorithm? There are two temperatures that basically determine if the system goes into defrost mode or not, and they are T outdoor ambient and T outdoor tube. One intermediate parameter, T compensation, has also been created and involved in the calculation. T compensation can be determined by T outdoor tube, 1) If T outdoor tube > 35.6 F, T compensation = 0 F 2) If T outdoor tube 35.6 F, T compensation = 5.4 F

Fundamental Functions HEAT Mode When will the system go into defrost mode? When the system continuously runs in heating mode for more than 45 minutes or the compressor accumulated run time is more than 90 minutes, the unit will switch to defrost mode under any of the following conditions, 1) T outdoor ambient 41 F, T outdoor tube 28.4 F 2) 28.4 F > T outdoor ambient < 41 F, T outdoor tube 21.2 F 3) 23 F T outdoor ambient < 28.4 F, T outdoor tube 17.6 F 4) 14 F T outdoor ambient < 23 F, T outdoor tube T outdoor ambient - 5.4 + T compensation 5) T outdoor ambient < 14 F, T outdoor tube T outdoor ambient - 5.4 + T compensation Other than these 5 conditions, the system could also switch to defrost mode under the following condition, 6) T outdoor ambient 41 F, compressor has more than 180 minutes accumulated run time, and T outdoor tube sensor continuously report the temperature is < 32 F for more than 1 minute. Note: Compressor accumulated run time can be cleared to 0 only under the following conditions. System finished a defrost cycle. System switched to cooling mode Compressor accumulated run time will NOT be cleared for any other conditions including System stops running when reaching the set indoor temperature System stops running for any protection System switches to fan mode

Fundamental Functions HEAT Mode When will the system stop defrost mode? The system will stop defrost cycle if ANY of the following conditions are satisfied 1) T outdoor tube 50 F 2) Defrost cycle reaches maximum defrost set time, typically this value is around 7-10 minutes and it varies model by model

Fundamental Functions HEAT Mode How does each component respond in sequence during a defrost cycle? Once the system determines to run a defrost cycle, first the indoor fan stop running and subsequently the compressor reduces the speed and stops within a minute. The outdoor fan will continue to run for another minute, and then stop. Fifteen seconds later, the switch over valve will switch the position from heating to defrost (or cooling). The compressor starts up again and increases into a relatively high speed to defrost. Once the system determine to exit a defrost cycle, the compressor decreases the speed and stops within a minute. A few seconds later, the switch over valve will switch the position from defrost (or cooling) to heating. After one minute, the compressor will operate again, and subsequently the outdoor fan and indoor fan will return to normal and run in heating mode.

Fundamental Functions HEAT Mode Protection Overcurrent protection If the total current is high, the compressor will run in limited or dropped frequency. When total current continues rising over the stated value, the compressor will stop, the outdoor fan will delay 30 seconds, then stop.

Fundamental Functions FAN Mode In this mode, the indoor fan will run the fan in High, Med, Low and Auto mode. The compressor, outdoor fan and four-way valve will stop.

Fundamental Functions AUTO Mode In this mode, the system selects COOL, HEAT and FAN mode automatically according to the change of ambient temperature. The protection function is the same with that of COOL/HEAT mode. The unit will adjust the running frequency of the compressor automatically according to the change of ambient temperature.

Other Control ON/OFF Each time the On/Off button of the remote controller is pressed, the On/Off state will switch once.

Other Control MODE SELECTION Press the MODE button on the remote controller to select and display the following modes: AUTO, COOL, DRY, FAN, and HEAT.

Other Control TEMP. Setting Button Each time TEMP+ or TEMP- button is pressed, the set temperature will be increased or decreased by 2 F. Adjusting range is 61 F ~ 86 F. In AUTO mode, this button does not function.

Other Control AUTO Key Press the AUTO key to start the unit. The unit will run in AUTO mode. When the unit is running, press the AUTO key to stop the unit. 16~22 SEER Heat Pump Models 16 SEER Cooling Only and Heat Pump Models

Other Control Timer Control The unit is turned on or off according to the timer set by the remote controller.

Other Control Sleep Control When the air conditioner is in COOL or DRY mode, after Sleep mode has been set properly, the preset room set temperature will be increased by 2 F after the sleep program has run for 1 hour. The room set temperature will be increased by another 2 F after 2 hours. The room set temperature has been increased by 4 F total in two hours. The unit will continue to run at this set temperature and at the set speed. When the air conditioner is in HEAT mode, after Sleep mode has been set properly, the preset room set temperature will be decreased by 2 F after the sleep program has run for 1 hour. The room set temperature will be decreased by another 2 F after 2 hours. The room set temperature has now been decreased by 4 F total in two hours. The unit will continue to run at this set temperature and at the set speed. In AUTO or FAN mode, the setting temperature will not change.

Other Control Indoor Fan Control Use the remote control to set the indoor fan to run at HIGH, MED, or LOW speed. It can also be set to AUTO. The indoor unit will select the fan speed (HIGH, MED, or LOW) automatically according to ambient temperature. There are at least 3 minutes and 30 seconds delay for fan speed shift.

Other Control Power Supply for Outdoor Unit The power supply for the outdoor unit is turned on in AUTO, COOL, HEAT, and DRY mode under the turn-on state. The power supply for the outdoor unit will delay 3 minutes to turn off under the turn-off state or in the FAN mode under the turn-on state.

Other Control Swing Control Use the SWING button of the wireless remote control to control SWING On and Off. Swing will only act when the indoor fan is running. After power off, the swing motor turns back to 0 position and closes the air outlet vent. If it does not enter a preset swing mode, after the unit is turned on, it will turn to the maximum air outlet D1 position, then turn back to L position under COOL mode. Under HEAT mode, the guide louver stays at D1. When in a swing mode, it will swing between L1 and D1 position. When the unit is turned off, it will turn back to the 0 position.

Other Control Buzzer Control When the unit is powered on or receives a remote control signal, or the auto key be pressed, the buzzer will give out a beep.

Other Control Power-off Memory Function Contents of memory: Mode; Swing; Set fan speed, Set temperature, Timing etc. Under turn-on state, when powered on, the power supply for the outdoor unit will be turned on after 3 minutes. Under turn-off state, when powered off, the power supply for the outdoor unit will be turned off immediately.

Other Control Delay Protection of Compressor Under COOL, DRY, and HEAT modes, there will be a 3 minute time delay before the compressor starts.

Common Protection Function in Each Mode Overload Protection T tube: In cooling mode, it detects the temperature of the outdoor heat exchanger, in heating mode, it detects the temperature of the indoor heat exchanger. When T tube detects high temperature, the compressor will run in limited frequency. When T tube temperature continues rising over the stated value, the compressor will stop. Under AUTO HEAT or HEAT mode, the indoor fan will blow 60 seconds at low fan speed and then stop. Under other modes, the indoor fan will run at set speed.

Common Protection Function in Each Mode Compressor Discharge Temperature Protection When the discharge temperature is too high over the stated value, the compressor will stop. When the discharge temperature drops to normal and the compressor has stopped for 3 minutes, the unit will resume its original operating status.

Common Protection Function in Each Mode Communication Malfunction When not receiving a correct signal for 3 minutes, the unit has a communication malfunction and the outdoor unit stops. It is the same as a normal stop when meeting the set temperature.

Common Protection Function in Each Mode Module Protection When the module is in protection, the compressor will stop. After the compressor has stopped for 3 minutes, it will resume operation. During the module protection period, the indoor unit displays error code H5 and the entire system stops.