Precision Temperature Humidity Meter DTH184DL User s Manual

Similar documents
Precision Temperature Humidity Meter DTH184DL User s Manual

Temperature/Humidity Monitor. User s Manual

Specifications Minimum Typical Maximum Unit

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

EL-USB-1-LCD Temperature Data Logger with LCD

ELMTEC. Kattreppeln Königslutter / /

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

EL-USB-1-LCD Temperature Data Logger with LCD

Introduction. OM-THA2

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

EasyLog Data Logger Series

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

EasyLog Data Logger Series

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

USB DATA LOGGER FOR TEMPERATURE AND RH HM9000

EL-USB-TC Thermocouple Data Logger with USB Interface

USER MANUAL USB Multi-Function Datalogger Model RHT35

Thermohygrometer with Single Type K Input and Superheat Function

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

OPERATION MANUAL TEMPERATURE. HUMIDITY MONITOR / ON-LINE LOGGER. Monitor. On-line Logger AMT208 AMT207

EL-OEM-3 OEM Packaged Voltage Data Logger

Users Manual. Air Velocity Meter


User's Guide. CO 2 Monitor. Model CO200

Sirius Technologies, Inc.

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

THX-DL Data Logger USER & INSTALLATION MANUAL V

E1000 Portable gas detector

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

TV2 Clean Room Monitor

TV2 Room Pressure Monitor Quick Start Guide

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

CDL 210. Operating manual. CO2 Logger. Best.-Nr

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Operation Manual Professional Remote Weather Station

USER GUIDE Heat Index Psychrometer

IRT2 Dual Laser IR Thermometer - User Guide

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Manual Vane Anemometer PCE-VA 20

IMR EX610. Portable Gas Detector. Operation Manual

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

data logger DL200H DL200D DL200L

Analog Room Pressure Monitor RPC Series

Indoor/Outdoor Temperature Alert

Sintrol Snifter A2 EX. Manual. Version 1.2.3

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

4-in-1 Humidity, Temperature Airflow and Light Meter

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

GasAlertMicroClip X3 Specifications

Refrigerant Leak Detector

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

WIRELESS COLOR FORECAST STATION

Model 5190-F Temperature/Humidity Probe

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Users Manual. Visit us at

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Model 5190-E Temperature/Humidity Probe

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

DP 300 mobile dew point instrument

WS3650IT. Pro Family weather station with T/H sensor, pluviometer, anemometer & PC connection.

Manual Hygrometer PCE-555

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Digijock Home Security

TM-802 Formaldehyde Meter User s Manual

Temperature Data Logging

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

Multifunction IAQ Monitor

A660 Air Conditioning Laboratory Unit

CEM CEM DT-175CV1. AC Current & Voltage Datalogger (P136)

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

User Manual. Humidity-Temperature Chart Recorder. Model RH520

QIAcube HT Unpacking and Installation Instructions

EL-OEM-3 OEM Packaged Voltage Data Logger

User Manual. Non-contact Infrared Thermometer.

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Wet Bulb Thermo-Hygrometer Datalogger

IMR IX176 Portable Gas Detector User Manual

ECOLOG Data logger series we prove it.

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Compact Ultra Low Temperature Chamber

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Wireless Color Weather Station

Transcription:

Precision Temperature Humidity Meter DTH184DL User s Manual HB2TM1840000

Table of Contents 1. PREFACE...2 2. CHARACTERISTICS...2 3. GENERAL SPECIFICATIONS...3 4. ELECTRICAL SPECIFICATION...3 5. INSTRUMENT DESCRIPTION...4 6. LCD DESCRIPTION...5 7. MEASUREMENT PROCEDURES...6 8. MAXIMUM/MINIMUM...6 9. AUTO POWER OFF...6 10. RELATIVE DEDUCTION VALUE(REL)...6 11. SETUP MODE...7 12. ENABLE ALARM SETUP...7 13. LOW ALARM TEMPERATURE SETUP...8 14. HIGH ALARM TEMPERATURE SETUP...8 15. LOW ALARM HUMIDITY SETUP...9 16. HIGH ALARM HUMIDITY SETUP...9 17. CLOCK SETUP...10 18. AUTO RECORDING TIME SETUP...10 19. AUTO POWER OFF TIME SETUP...11 20. SINGLE DATA RECORD...11 21. VIEWING DATA RECORDS...11 22. BATTERY REPLACEMENT...12 23. EXTERNAL DC POWER...12 24. SAFETY PRECAUTION...12 25. COMPUTER GRADE...12 26. SOFTWARE INSTALLATION...13 27. MAINTENANCE...16 28. END OF LIFE...16

1. PREFACE Thank you for your patronage, please read the operating instructions before you use this meter, so you will operate the meter correctly. WARNING Without following the operating instructions might damage the instrument or its component 2. CHARACTERISTICS LCD display. It shows both the value of temperature and humidity. The measurement of C or F. Real time data. Data Hold function. Alarm function. Back Light Auto Power Off DEW-POINT and WET-BULB temperature USB PC interface Low battery indication. Over load display OL 2

3. General Specifications Display: Double row LCD, humidity display capability up to 999, and temperature display capability up to 1999. Temperature sensor: Diode. Humidity Sensor: Capacitor Sensor. Sampling: 1 time/second. Power: 9V battery NEDA 1604 IEC 6F22 or JIS 006P(Only data logger use), or AC to DC Adapter. (9V/300mA). Resolution:0.1%RH,0.1 C,0.1 F. Size: 5.1" x 2.2" x 1.5" (130x56 x38 mm)(lxwxh). Weight: 8.8oz(250g). Operating Temperature and Humidity: -20 C +60 C <95% RH.(Non-condensing). Storage Temperature and Humidity: -10 to 60 C, <70% RH. (Non-condensing). Consumption Current: 10mA, WARNING Do not Touch Humidity Sensor Surfaces 4. Electrical Specification Measurement Range: Humidity: 5%~95%. Temprature: -20.0 ~~. Temperature Accuracy: ± /± 0.0 C 40.0 C ; other ± /. Humidity Accuracy: ±1.0%RH(at 25 C,15%RH~80%RH). ±2.5%RH(at 25 C,<15%RH,>80%RH). WARNING s this meter in high humidity environment, please put the meter warm and low humidity place for 24 hours after finishing measurement. WARNING In order to ensure the accuracy of this meter, We strongly recommend send the meter back to original factory for maintenance every year 3

5. Instrument description 1. Sensor Probe input(-) 2. LCD 3. Power Button 4. Backlight/Down Button 5. Hold/Up Button 6. REL/SET/Time Button 7. MAX/Min/MEM Button 8. TMP/RH/WB/DP Button 9. REC/ / Button 10. External power DC 9V 11. USB interface 12. Sensor Probe input(+) 13. Sensor Probe 14. Temperature & Humidity module 15. Temperature & Humidity sensor 4

6. LCD description 1. Primary Display 2. Secondary Display 3. Temperature unit ( ) 4. Temperature unit ( ) 5. WET-BULB temperature 6. DEW-POINT temperature 7. Humidity unit 8. Time unit (month: day) 9. Time unit (hour: minute) 10. Time unit (second) 11. Low battery symbol 12. Auto power off symbol 13. Memory reading symbol 14. SET symbol 15. REL symbol 16. Hold symbol 17. MAX symbol 18. MIN symbol 19. REC symbol 20. High symbol 21. LO symbol 22. Alarm symbol 5

7. Measurement Procedures Press button to turn on the meter, press button again to turn off the meter. Hold button and press button to change temperature unit.(deform temperature unit ) Press button to change the display data. Humidity(%RH) DEW-POINT(WET) WET-BULB(DEW). Press button to lock display data on the LCD,press button again to unlock. 8. Maximum/Minimum Press button to enter MAX/MIN record mode and the LCD will display Maximum temperature data, and start to record maximum and minimum data, LCD secondary display shows that enter MAX/MIN record mode the time elapsed, when entering MAX/MIN record mode, The maximum storage is up to 99 minutes and 99seconds Press button to change Maximum or Minimum Press button to change the display data. (Temperature Humidity(%RH) DEW-POINT(WET) WET-BULB) (DEW). Press button for more than 1 second to exit maximum/minimum mode. 9. Auto Power Off If you want disable auto power off, please hold button and press button, the auto power off symbol will not display on the LCD If you want enable auto power off please hold button and press button again the auto power off symbol will display on the LCD. Auto power off time is 30 minutes long 10. Relative Deduction Value(REL) Press button to save the current measured result, and then the current measured result will be subtracted by the next measured result, and the difference from the subtraction will appear on the LCD. Press mode. button again to exit REL 6

11. Setup Mode Hold button and press button into the setup mode Press button to change the setup function. (Setup function see Note1) Push button to save setup data Note1: you can set up 7 different functions in setup mode 1. Enable or disable alarm 2. Low alarm temperature setup 3. High alarm temperature setup 4. Low alarm humidity setup 5. High alarm humidity setup 6. Clock setup 7. Auto recording time setup 8. Auto power off time setup 12. Enable Alarm Setup Hold button and press button to enable alarm setup If you want to enable alarm please press or button, LCD will display Alarm On. Press button to save the setting. When alarm sound action you can push button to stop alarm sound and this time to stop alarm mode,this time meter auto set alarm data to High Temperature(Humidity) 60.0 ;99.9%RH,Low Alarm Temperature(Humidity) 20.0 ;0.1%RH. 7

13. Low Alarm Temperature Setup Hold button and press button first And then press button to enable Low Alarm Temperature setup If you want to set the range for the low alarm temperature function, please Pres or button Low alarm temperature range from 20.0 to 60.0 (-4.0 ~140.0 ) Press button to save the setting. 14. High Alarm Temperature Setup Hold button and press button first And then press button twice to enable High Alarm Temperature setup If you want to change the range for the high alarm temperature function, please press or button High alarm temperature range is from 20.0 to 60.0 (-4.0 ~140.0 ) Push button to save the setting 8

15. Low Alarm Humidity Setup Hold button and press button first And then press button three times to enable Low Alarm Humidity setup If you want to change the range for the low alarm humidity function, please push or button Low alarm humidity range 0.1%RH~99.9%RH Press button to save the setting. 16. High Alarm Humidity Setup Hold button and press button first And then press button four times to enable High Alarm Humidity setup If you want to change the range for the high alarm humidity function, please press or button High alarm humidity range is from 0.1%RH to 99.9%RH Press button to save the setting 9

17. Clock Setup Hold button and press button first And then press button five times to enable Clock Setup This meter clock is 24 hour time setting. Use or to select the digit you want to adjust Use or button to change digit Press button to save the setting Time deform set 2008/01/01 12:12:12 18. Auto Recording Time Setup Hold button and press button first And then press button 6 times to enable Auto Recording Time Setup Use or to select option to adjust Use or button to change digit Press button to save the setting Maximum auto recording time: 23 hours 59 minutes 59 seconds Minimum auto recoding time: 1 second 10

19. Auto Power off time setup Hold button and press button first And then press button seven times to enable Auto Power off time Setup Use or button to change digit Press button to save the setting If you do not want auto power to be on, you can set auto power off time to be 0 Maximum auto power off time: 99 minutes 20. Single Data Record Press button, the meter will save the current measured result, and REC will also appear on the LCD. 21. Viewing Data Records Hold button and press button to view the saved data records Use or button to see the next or previous records Press to change temperature unit Press button to change display data (Temperature Humidity DEW-POINT WET-BULB) Press button to change time data (H:M M:D year) Hold button and press button again to exit viewing data records mode 11

22. Battery Replacement If the LCD display WARNING symbol, please replace the battery immediately Turn off the instrument. Open the battery cover and remove the battery. Replace with four-9v NEDA 1604, IEC 6F22 or JIS 006P size battery. Install the battery cover. WARNING If you will not use this meter for a long time, please remove the battery in order to protect the meter. 23. External DC Power External AC to DC adapter: Voltage 9V DC (8~14V DC Max) Socket:pin Positive, Ground Casing External Diameter 5.5mm internal Diameter 2.1 mm 24. Safety Precaution For cleaning the instrument, use a soft dry cloth. Never use a wet cloth, solvents or water, etc. Data logging capacity with Memory Size:30000 data sets Operation Altitude: Up to 2000M. Operating Environment: Indoors use only. This instrument has been designed for being used in an environment of pollution degree 2. 25. Computer Grade CPU:Pentium Ⅲ 1000MHZ RAM:SDRAM 256MB Hard Disk:200MB OS:Windows 2000, Windows XP Display: 800 600 256 cooler 12

26. Software installation Please insert the CD into the PC to install the software first. Please select the USB driver to be installed, which is E:\TM-184\PL-2303 Driver Installer.exe (windows 2000 SP4/windows XP SP2), click twice on the left key of the mouse to install the USB driver. 13

Select the SETUP.EXE i.e., E:\TM-184\SETUP.EXE and installs the desktop icon Tack out the CD from PC after completed the installation. 14

Use the USB cable to connect the meter and the computer according to the drawing. Select the desktop icon (TM-185) and click twice on left key of the mouse to run the procedure. 15

27. Maintenance Do not use the meter in an environment with severe change; do not store the unit in an environment with high temperature, high humidity, and high vibration Take battery out if the meter has not been used for a long period of time The Diode temperature probe is used to measure temperature and the capacitive humidity sensor is used to measure humidity The thermocouple and humidity sensor will start aging under the influence of oxidation, reduction, corrosion, pollution, vaporization, diffusion or other metallurgy. The aging process will affect its precision seriously. Cleaning and inspection of temperature probe: The smoke, coal, dust, grease attached on the protective tube of temperature probe will slow down the heat conduction of the thermocouple and cause measuring error. Therefore, it should be cleaned periodically. The metal coating of thin thermocouple should be replaced properly upon the occurrence of corrosion. Cleaning and inspection of humidity sensor: The smoke and dust attached on the humidity sensor will slow down the function of humidity sensor and cause measuring error. Therefore, it should be cleaned periodically. Blow off the dust with mild compressed air instead of water or alcohol. The aluminum plate inside the humidity sensor should be replaced upon the occurrence of corrosion. 28. End of life Caution: this symbol indicates that equipment and its accessories should be subject to a separate collection and correct disposal 16