GAS FURNACES. Visit taxcredit for complete details.

Similar documents
GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

GAS FURNACES. RGFD- SERIES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to kw] (All Models 92% A.F.U.E.

GAS FURNACES 90 PLUS COMMUNICATING MODULATING UPFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND CONTOUR COMFORT CONTROL

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

GAS FURNACES 90 PLUS COMMUNICATING MODULATING DOWNFLOW GAS FURNACES EQUIPPED WITH THE COMFORT CONTROL 2 SYSTEM AND

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Classic Plus Series Multi position Gas Furnaces

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

GAS FURNACES II 78% A.F.U.E. UPFLOW GAS FURNACES CRITERION

Rheem Prestige Series Modulating Horizontal Gas Furnace equipped with the Comfort Control 2. System

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

80% A.F.U.E. DOWNFLOW GAS FURNACES

Multi-Position Gas Furnaces

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

Multi-Position Gas Furnaces

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Rheem Classic Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

Ruud Achiever Plus Series Multi-position Gas Furnaces

MULTI POSITION GAS FURNACE

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

Ruud Achiever Series Multi position Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Multi-Position. Gas Furnaces

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

COMMUNICATING TWO-STAGE VARIABLE SPEED MULTI-POSITION GAS FURNACES

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

OIL FURNACES PREMIUM CLASS UPFLOW OIL FURNACES. ROBF- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to kw]

Ruud Ultra Series EcoNet Enabled Two-Stage Variable Speed Multi- Position Gas Furances

INTEGRATED HVAC & WATER HEATING

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Hydronic Air Handler Powered by Tankless Technology

TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS

Hydronic Air Handler Powered by Tankless Technology

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Rheem Classic. Series Highboy & Lowboy Oil Furnaces with PSC/Direct Drive Motor

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Wt. Lbs Model Number (BTUH) Hz

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Hydronic Air Handler Powered by Tankless Technology

Comfort, Quality and Efficiency.

Energy Saving. Space Saving.

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Cooling Capacity CFM in. w.c. (125 Pa)

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

TSTAT0201CW Recommended (sold separately)

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended (order separately)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

G34M Bulletin #69/ August 2003

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Cooling Capacity CFM range

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

AIR HANDLERS AIR HANDLERS

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Transcription:

FORM NO. G11-501 Supersedes Form No. G11-501 GAS FURNACES Visit www.rheemac.com/ taxcredit for complete details. RGRM- SERIES ECM Equipped Models with Input Rates of 45,000, 60,000, 75,000, 90,000, 105,000 & 0,000 BTU/HR [13.19, 17.58, 22, 26.38, 30.77 & 35.17 kw] (45K through 105K Models Rated at 95% A.F.U.E., 0K Model Rated at 93.3% A.F.U.E.) 95% A.F.U.E. WITH DUAL COMFORT CONTROL TWO-STAGE UPF GAS FURNACES The Rheem Classic Series 95% A.F.U.E. with Dual Comfort Control line of upflow gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the low-profile 34 inch [864 mm] height, the upflow model can also be used to satisfy most applications. The design is certified by CSA. Features Two stages of operation to save energy and maintain optimal comfort level. Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. Compatible with single or two-stage thermostat. (For optimal performance a two-stage thermostat is recommended.) Heat exchanger is constructed of all stainless steel for maximum corrosion resistance and thermal fatigue reliability. Low profile 34 inch design is lighter and easier to handle and leaves room for optional accessories. Left or right side gas, electric, and condensate drainage connections. Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. Variable speed blower motor technology provides ultimate humidity control, quieter sound levels and year-round energy savings. Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or side of the cabinet on all upflow models. A special molded fitting is provided to ease installation. Solid bottom is standard. Control board diagnostics. A variety of cooling coils and plenums designed to use with the Rheem Classic Series 95% A.F.U.E. gas furnaces are available as optional accessories for air conditioning models. A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.

CLASSIC SERIES 90 PLUS EFFICIENCY UPF GAS FURNACE REMOTE SENSOR PRIMARY AND SECONDARY HEAT EXCHANGER DIRECT SPARK IGNITION & REMOTE SENSOR IN-SHOT BURNERS GAS VALVE AND MANIFOLD PRESSURE SWITCHES DRAFT INDUCER INTEGRATED FURNACE CONTROL ECM MOTOR STANDARD EQUIPMENT Completely assembled and wired; heat exchanger; primary: 409 stainless steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) 2 Rheem Heating, Cooling and Water Heating OPTIONAL EQUIPMENT Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. PHYSICAL DATA AND SPECIFICATIONS UPF MODELS U.S. and Canadian Models MODEL NUMBERS RGRM-04*MAES RGRM-06*MAES RGRM-07*MAES RGRM-07*YBGS RGRM-09*ZAJS FIRE INPUT BTU/HR [kw] ➀ 45,000 [13.19] 60,000 [17.58] 75,000 [21.98] 75,000 [21.98] 90,000 [26.38] FIRE INPUT BTU/HR [kw] ➁ 31,500 [9.23] 42,000 [.31] 52,500 [15.39] 52,500 [15.39] 63,000 [18.46] HEATING CAPACITY BTU/HR [kw] 42,000 [.31] 56,000 [16.41] 70,000 [20.51] 70,000 [20.51] 84,000 [24.62] ALTITUDE INPUT 8000' ➁ 30,600 [8.97] 40,800 [11.96] 51,000 [14.95] 51,000 [14.95] 61,200 [17.94] ALTITUDE OUTPUT AT 8000' ( FIRE) [kw] ➁ BER (D x W) [mm] MOTOR H.P. [W] S TYPE 28,458 [8.34] 37,944 [11.] 47,430 [13.90] 47,430 [13.90] 56,916 [16.69] 1/2 [373] VAR. 1/2 [373] VAR. x 11 1 [746] VAR. MOTOR FULL LOAD AMPS 8.7 8.7 8.7 MINIMUM EXT. STATIC PRESSURE (IN. W.C.) [kpa].10 [0.25]. [.029]. [.029]. [.029].15 [.037].20 [.049].20 [.049] MAXIMUM EXT. STATIC PRESSURE (IN. W.C.) [kpa].80 [0.2].80 [0.2].80 [0.2].80 [0.2].80 [0.2].80 [0.2].80 [0.2] HEATING CFM @.2" [.049 kpa] W.C. E.S.P. [L/s] 850 725 765 1180 75 1400 50 HEATING CFM @.2" [.049 kpa] W.C. E.S.P. [L/s] 780 900 1080 1180 1450 1604 1450 A = 00 A = 00 A = 00 A = 1600 A = 2000 A = 2000 A = 2000 COOLING CFM @.8" [.4 kpa] W.C. E.S.P. [L/s] B = 1000 C = 800 B = 1000 C = 800 B = 1000 C = 800 B = 1400 C = 00 B = 1600 C = 1400 B = 1600 C = 1400 B = 1600 C = 1400 D = 600 D = 600 D = 600 D = 1000 D = 00 D = 00 D = 00 A = 900 A = 900 A = 900 A = 00 A = 1500 A = 1500 A = 1500 COOLING CFM @.8" B = 750 B = 750 B = 750 B = 1050 B = 00 B = 00 B = 00 [.4 kpa] W.C. E.S.P. [L/s] C = 600 C = 600 C = 600 C = 900 C = 1050 C = 1050 C = 1050 D = 450 D = 450 D = 450 D = 750 D = 900 D = 900 D = 900 TEMPERATURE RISE- FIRE RANGE IN DEGREES F [ C] TEMPERATURE RISE- FIRE RANGE IN DEGREES F [ C] RETURN AIR CABINETS (OPT.) RXGR- FILTER SIZE [mm] STANDARD, VELOCITY PERMANENT FILTER (IN.) APPROX. SHIPPING WEIGHT (LBS.) [kg] 30-60 [16.7-33.3] 15-45 [8.3-25] C17B (2) " x 16" [305 x 406] 117 [53.2] 40-70 [22.2-38.9] 35-65 [19.4-36.1] C17B (2) " x 16" [305 x 406] 3 [56.0] 1/2 [373] VAR. 40-70 [22.2-38.9] 35-65 [19.4-36.1] C17B (2) " x 16" [305 x 406] 35-65 [19.4-36.1] 25-55 [13.9-30.6] C21B (2) " x 20" [305 x 508] x 1 x 1 x 1 x 1 19 1 /4 x 25 x 1 8 [58.2] x 7 [305 x 178] 1 [746] VAR. 35-65 [19.4-36.1] 20-50 [11.1-27.8] C21B (2) " x 20" [305 x 508] 139 [63.2] 148 [67.3] AFUE ➂ 95.0% 95.0% 95.0% 95.0% 95.0% RGRM-10*ZAJS 105,000 [30.77] 73,500 [21.54] 97,000 [28.43] 71,400 [20.93] 66,402 [19.46] x 11 1 [746] VAR. 40-70 [22.2-38.9] 30-60 [16.7-33.3] C21B (2) " x 20" [305 x 508] 19 1 /4 x 25 x 1 150 [68.2] 95.0% RGRM-*RAJS 0,000 [35.17] 84,000 [24.62] 113,000 [33.] 81,600 [23.91] 75,888 [22.24] 11 x 10 [279 x 254] 1 [746] VAR. 50-80 [27.8-4.4] 40-70 [22.2 38.9] MAX. OUTLET AIR TEMPERATURE 160 170 180 170 165 180 180 NOTES: All models are 115V, 60HZ, 1 phase. Gas connection size for all models is 1 /2" [13 mm] N.P.T. ➀ See Conversion Kit Index Form for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. *E=Standard *N=NOx Models C24B (2) 14" x 16" [609 x 406] 22 3 /4 x 25 x 1 159 [72.3] 93.3% WARNING: Some heating airflow values may be higher than those required for cooling. Be sure to size duct systems for highest possible airflow value. Rheem Heating, Cooling and Water Heating 3

MODEL IDENTIFICATION R G R M 07E* Y B G S 278 Rheem Gas Furnace Upflow Condensing Gas Furnace Design Series Electric Ignition 04* 06* 07* 09* 10* * Heating Input Designation Input BTU/HR 45,000 [13.19 kw] 60,000 [17.58 kw] 75,000 [22 kw] 90,000 [26.38 kw] 105,000 [30.77 kw] 0,000 [35.17 kw] NOTES: *E = Standard *N = NO x Models Blower Size M = [279 x 178 mm] R = 11 x 10 [279 x 254 mm] Z = x 11 [305 x 279 mm] Y = x 7 [305 x 178 mm] Variations A = Std. B = Wide Heat/Cool Designation E = 1100-1300 CFM [519-613.5 L/s] G = 1500-1700 CFM [707.9-802.3 L/s] J = 1900-2100 CFM [896.7-991.1 L/s] Fuel Code S = U.S. and Canadian Option Code for High Altitude Available Models: RGRM-04EMAES RGRM-07EMAES RGRM-09EZAJS278 RGRM-04NMAES RGRM-07NMAES RGRM-10EZAJS RGRM-04EMAES278 RGRM-07EYBGS RGRM-10NZAJS RGRM-06EMAES RGRM-07NYBGS RGRM-ERAJS RGRM-06NMAES RGRM-09EZAJS RGRM-NRAJS RGRM-06EMAES278 RGRM-09NZAJS RGRM-ERAJS78 [ ] Designates Metric Conversions 4 Rheem Heating, Cooling and Water Heating

UPF MODELS MINIMUM CLEARANCE (IN.) [mm] MODEL LEFT A B C D E F RGRM- SIDE RIGHT BACK TOP FRONT VENT SIDE 04*M 17.5 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 15 1 /2 [422] 13 25 /32 [352] 0 0 0 1 [25] 2 [51] 0 06*M 17.5 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 15 1 /2 [422] 13 25 /32 [352] 0 0 0 1 [25] 2 [51] 0 07*M 17.5 [445] 16 11 /32 [415] 15 5 /8 [397] 2 [51] 15 1 /2 [422] 13 25 /32 [352] 0 0 0 1 [25] 2 [51] 0 07*Y 21 [533] 19 27 /32 [504] 19 1 /8 [487] 2 [51] 18 1 /2 [511] 17 9 /322 [441] 0 0 0 1 [25] 2 [51] 0 09*Z 21 [533] 19 27 /32 [504] 19 1 /8 [487] 2 [51] 18 1 /2 [511] 17 9 /322 [441] 0 0 0 1 [25] 2 [51] 0 10*Z 21 [533] 19 27 /32 [504] 19 1 /8 [487] 2 [51] 18 1 /2 [511] 17 9 /322 [441] 0 0 0 1 [25] 2 [51] 0 *R 24.5 [622] 23 11 /32 [593] 22 5 /8 [575] 2 [51] 22 1 /2 [600] 20 25 /32 [530] 0 0 0 1 [25] 2 [51] 0 *E=Standard *N=NO x [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating 5

BER PERFORMANCE DATA** RGRM MODELS MODEL RGRM- RGRM-04*M RGRM-06*M RGRM-07*M RGRM-07*Y RGRM-09*Z RGRM-10*Z RGRM-*R *E=Standard *N=NO x Models BER SIZE (D x W) IN. [mm] x 7 x 11 x 11 11x 10 [279 x 254] ECM MOTOR H.P. [W] 1/2 [373] 1/2 [373] 1/2 [373] 1 [746] 1 [746] 1 [746] 1 [746] BER -HI -HI -HI -HI -HI -HI -HI CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 [.02] 0.8 [.20] 1000 [472] 800 [378] 600 [283] 1000 [472] 800 [378] 600 [283] 1000 [472] 800 [378] 600 [283] 1600 [755] 1400 [661] 1000 [472] 2000 [944] 1600 [755] 1400 [661] 2000 [944] 1600 [755] 1400 [661] 2000 [944] 1600 [755] 1400 [661] [ ] Designates Metric Conversions GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Primary and Secondary Heat Exchanger...Limited Lifetime Conditional Parts Warranty (Registration Required)...Ten (10) Years Conditional Unit Replacement Warranty (Registration Required)...Ten (10) Years 6 Rheem Heating, Cooling and Water Heating

ACCESSORIES UPF VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/ VERTICAL = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM: RXGR-C17B, RXGR-C21B, RXGR-C24B PLENUM DATA FOR A COILS Plenum adapters are required in some instances for use on upflow applications when plenum and furnace size do not match. FURNACE WIDTH IN. [mm] PLENUM WIDTH IN. [mm] PLENUM ADAPTER UPF COIL PLENUM 14 1 /2 [356] 16 1 /4 [413] RXAA-C171 RXAL-B16BU 14 1 /2 [356] 20 1 /4 [514] RXAA-C172 RXAL-B20BU 17 1 /2 [445] 16 1 /4 [413] RXAA-C185 RXAL-B16BU 17 1 /2 [445] 20 1 /4 [514] RXAA-C173 RXAL-B20BU 17 1 /2 [445] 21 5 /8 [549] RXAA-C187 RXAL-B21BU 17 1 /2 [445] 25 1 /4 [641] RXAA-C174 RXAL-B25BU 21 [533] 25 1 /4 [641] RXAA-C175 RXAL-B25BU 21 [533] 22 1 /4 [565] RXAA-C176 RXAL-B22BU 21 [533] 21 5 /8 [549] RXAA-C188 RXAL-B21BU Note: 24See 1 /2 [622] Form Number 25 1 /4 C11-206 [641] for MultiFlex RXAA-C177 coil data. RXAL-B25BU 24 1 /2 [622] 21 5 /8 [549] RXAA-C187 RXAL-B21BU Note: See Form Number C11-206 for MultiFlex coil data. FOR ALTITUDES: ALTITUDE KIT: INPUT BTU/HR [kw] ALTITUDE KIT NO. RGRM-04*M RXGY-F18 RGRM-06*M RXGY-F18 RGRM-07*M Not Required RGRM-07*Y Not Required RGRM-09*Z RXGY-F20 RGRM-10*Z Not Required RGRM-*R RXGY-F21 Option 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas. CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. For all installations above 2000 ft. (including all option 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. (U.S. Models Kit packaged with furnace. Requires field installation). LP CONVERSION KITS: U.S./Canadian RXGJ-FP19 or RXGJ-FP21 EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE FILTER RACK: RXGF-CA MODEL RGRM- 04 06 07EM 07NM 07EY 07NY 09 10 FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CB (BOTTOM) 19 1 /4 x 25 [489 x 635] 19 1 /4 x 25 [489 x 635] 19 1 /4 x 25 [489 x 635] 22 3 /4 x 25 [578 x 635] RXGF-CA (SIDE) *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. [ ] Designates Metric Conversions Rheem Heating, Cooling and Water Heating 7

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Rheem Heating, Cooling and Water Heating P.O. Box 17010, Fort Smith, AR 72917 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. PRINTED IN U.S.A. 5-09 DC FORM NO. G11-501 Supersedes Form No. G11-501 Rev. 5