ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

Similar documents
ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

RAE Systems RAE Systems RAE Systems Presented by David Lucha RAE Systems Protectio n Through Detection

RAE Systems. Using the MeshGuard. Protection Through Detection

UltraRAE 3000 Basic Operation Pocket Reference

MiniRAE 3000 ppbrae Basic Operation Pocket Reference

Using the QRAE Plus personal multigas monitor

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

UNI 321. User s Guide

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

MeshGuard LEL User s Guide

RAE Systems Systems. User Presentation. October Protection Through Detection

GasAlertMicroClip X3 Specifications

ToxiRAE 3 User s Guide

MeshGuard TM Monitor User s Guide

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Single Gas Detector. Quick Reference Guide

ToxiPro. Single Gas Detector. Reference Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

ALTAIR 5X Multigas Detector Product Specification

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Personal Single Gas Monitor. Activation Operation Troubleshooting

IMR IX176 Portable Gas Detector User Manual

Operate the Mutli-Gas Monitor PID

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

SC-01 Operator s Manual

Operating Instructions Compur Monitox plus

multi-gas detector Go the distance, and save Wear yellow. Work safe.

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

S ing le G a s D etec tor. R eferenc e M a nua l

Monitores Personales. Personal Monitor

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

E1000 Portable gas detector

Reference Manual. MultiVision Gas Detector

Model GP-01 Combustible Gas Monitor Operator s Manual

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

Single Gas Monitor 777

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Using the GammaRAE II Personal Radiation Detector

Clip SGD. Portable single Gas Detector. User manual

Using the MiniRAE 2000 & ppbrae PID

IMR EX610. Portable Gas Detector. Operation Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

03 Series: OX-03, CO-03, HS-03 Versions Operator s Manual

ToxiRAE 3 User s Guide

Operator s Manual. 1, 2, 3, and 4-Gas Detector

EchoView Host Mini-Controller for Closed-Loop Portable Wireless Solutions User s Guide

ALTAIR 5X Multigas Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Activation Operation Troubleshooting Part Number: Edition: Release Date:

GasWatch 2 Operator s Manual Part Number: RK Revision: E Released: 2/13/06

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

MeshGuard LEL IR MeshGuard CO2 IR User s Guide

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

User Manual. Single Gas Detector

RAEGuard 2 PID. User Guide

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

Product Manual. The Essential Guide for Safety Teams and Instrument Operators

Micro IV Operation Manual

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Bacharach Bodyguard 4 User's Guide

altair 2X Gas Detectors

For the Safety of Your

ToxiPro. Single Gas Detector. Reference Manual

Biosystems ToxiLtd. Single Gas Detector. Reference Manual

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

Wireless Personal Four-Gas Monitors

SENSIT HXG-2d Combustible Gas Detector

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

altair 2X Gas Detectors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

PGM100 Carbon Monoxide

ALTAIR 2X Gas Detectors It s what s inside that really counts

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Reference Manual MultiPro Gas Detector

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

GAS-Mate. Combustible Gas Leak Detector

MDU 420. Instruction Manual. Dual Range Methane Monitor. P/N REV 0 Printed Specifications Subject to Change

ATX620. Instruction Manual. Multi-Gas Monitor. P/N REV 02 Printed Specifications Subject to Change GUARANTEED. FOR LIFE.

BW Clip4. Portable Gas Detector. Operator Manual

Gas Detection. Product Guide EMEA PORTABLE GAS DETECTION

GX-2009 Portable Gas Monitor Operator s Manual

Model GX Operator s Manual

ALTAIR 5X Multigas Detector

Transcription:

ToxiRAE II PGM-1100 Series Personal Toxic Gas Monitor User Manual 045-4003-000, Revision B, March 2005

- READ BEFORE OPERATING - This manual must be carefully read by all individuals who have or will have the responsibility of using, maintaining, or servicing this product. The product will perform as designed only if it is used, maintained, and serviced in accordance with the manufacturer s instructions. CAUTION! To reduce the risk of electric shock, turn off power before removing the monitor cover. Disconnect the battery before removing sensor module for service. Never operate this monitor while the cover is removed. Remove monitor cover and sensor module only in an area known to be non-hazardous. Sensors are not interchangeable; use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use only RAE Systems batteries. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. Calibrate before use. Make sure gas inlet is free of dirt and debris. Properly recycle Lithium batteries when disposing. US & Canadian Intrinsic Safety UL/cUL Class I, Groups A, B, C, D, T5 European Intrinsic Safety 0575 II 1G EEx ia IIB T5 / 2G EEx ia IIC T5 DEMKO 02-40 C T amb 55 C ATEX 0233306X

Table of Contents US & Canadian Intrinsic Safety ii European Intrinsic Safety ii Standard Contents iv Calibration Kit iv General Information 1 Physical Description 2 Display Features 3 Operating the ToxiRAE II 4 Turning the Monitor ON 4 Using the ToxiRAE II 4 Time Weighted Average (TWA) 5 Peak Reading (PEAK) 5 Turning the Monitor OFF 5 Program Mode 6 Calibration 7 Changing Preset Limits or Span Gas Values 10 Maintenance 11 Replacing the Lithium Battery 11 Replacing the Sensor 12 Specifications 15 Table A: Sensor Configuration 16 Table B: Alarm Signals (H 2 S) 17

Standard Contents ToxiRAE II monitor with sensor as specified Lithium battery installed Spare Lithium battery Gas adapter Alligator clip Stainless steel belt clip / hardhat adapter Operation instructions Calibration Kit Test gas (for sensor as specified) Gas regulator with flow controller Hard transport case

General Information The ToxiRAE II single gas monitor continuously displays toxic gas concentrations and costs just a little more than disposable detectors. Unlike typical disposables that only display remaining life, the ToxiRAE II is full-featured gas monitor providing continuous, digital display of the selected toxic gas concentration, STEL, TWA and Peak values as well as high, low, TWA and STEL alarms. A simple to use one-button product, the ToxiRAE II is easy to calibrate. Use the pre-set alarms, or modify the alarms to meet your specific requirements. In contrast to disposables that are turned on once and remain on until their batteries expire, you decide when and where to use your ToxiRAE II and you turn it on and off accordingly. The ToxiRAE II does not have a preprogrammed expiration date so you get the full life out of the battery and sensor. Sensors and battery are easily replaced in the field, too. And, because the cost of the ToxiRAE II is about the same as many reduced-feature disposables, you have the choice of renewing it, or disposing of it and starting out with a fresh, new monitor. 1

Physical Description 1 Bright red LED Alarm 2 Display 3 Audio Alarm 4 Gas Inlet 5 Button 6 Alligator Clip 6 1 2 5 4 3 2

Display Features 1 Zero Calibration 2 Low Battery Indicator 3 Short Term Exposure Limit (STEL) 4 Time Weighted Average (TWA) 5 Low Alarm 6,7 High Alarm 8 Parts Per Million 9,10 Span Calibration 11 Gas Concentration 2 1 11 10 3 4 6 5 9 8 7 3

Operating the ToxiRAE II Turning the Monitor ON The sensor is zeroed at power on. Always turn the monitor on in clean ambient air. Using the ToxiRAE II Make sure the Lithium battery is installed. Hold the button down and release when it beeps. The monitor is now on. The monitor will perform a self-test preceding the warm-up and zero calibration. The user will see the firmware version displayed briefly (e.g. F10 means firmware version 1.0). Then the current gas concentration reading is displayed. After the monitor is turned on and completes its warmup, it is in Monitor Mode. The display shows the current concentration of the specified gas in ppm ( Current ppm ). The user can also view the exposure analysis - the STEL, TWA, and PEAK - in Monitor Mode. From the Current ppm display, press the button to cycle through each exposure analysis reading. If left idle for one minute, the monitor will automatically return to the Current ppm display from any of the analysis displays. After the monitor is turned on and completes its warmup, it is in Monitor Mode. The display shows the current concentration of the specified gas in ppm. 4

Short Term Exposure Limit (STEL) The STEL is the average reading of the gas concentration for the last 15 minutes. NOTE: The STEL reading does not appear until 15 minutes have elapsed. Time Weighted Average (TWA) The TWA is the accumulated reading of the gas concentration, divided by 8 hours, since the monitor was turned on. Peak Reading (PEAK) The peak reading is the highest reading since the monitor was turned on. NOTE: The display switches back and forth between P and the actual peak reading. If the pre-set alarm limits are exceeded, the monitor will go into alarm, and the user should leave the contaminated area immediately. See Table A for the preset limits. Turning the Monitor OFF Hold the button down, through the 5 4 3 2 1 OFF sequence. The monitor is off when the display is blank. 5

Program Mode Use the Program Mode to perform any of the following actions (listed in order of appearance): Calibrate the Monitor Changing Preset Limits or Span Gas Values Calibration To enter the Program Mode, press and release when Pro appears in the display. To exit the Program Mode at this point, do not press the button, and the monitor will automatically return to the reading display. Press and hold the button again. Release when go starts flashing on the screen. While all instruments are calibrated prior to leaving the factory, temperature extremes and/or shocks during shipment can cause sensor drift. Therefore, the accuracy of any newly purchased RAE Systems monitor should be tested by exposing the sensor to a known concentration calibration gas before the monitor is used or put into service. How often should you calibrate the monitor? The monitor should be calibrated no less than every 30 days, or if it does not pass a fresh air reading, or if it does not pass a field calibration. The sensors are calibrated in a two-step process using fresh air and span gas (a span gas contains a known concentration of a given gas). 6

Field Calibration For maximum safety, the accuracy of the monitor should be checked by field calibration: expose the sensor to known concentration calibration gas before each day s use. To do this, attach the calibration adapter to the unit. (See picture on page 9.) Connect the tubing to a cylinder of span gas. With the unit in Monitor Mode, turn the gas on and allow the measurement to reach a steady state. If the measurement displayed is +/-10% of the span gas concentration as noted on the cylinder, the unit is ready for use. (See page 6, How often should you calibrate the monitor? ) 7

8 Calibrate Monitor Span Gas Calibration Put the unit into Program Mode. CAL (calibration) and go messages switch back and forth in the display. Press and hold the button until go displays continuously without flashing on and off. The gas and span gas preset value will switch back and forth on the screen. During these 10 seconds, connect the span gas to the monitor. (See picture on page 9.) When calibrating, use tygon tubing for all sensors except Cl 2, ClO 2, and HCN. When the monitor detects a change in gas concentration or after 10 seconds of idle time, or when the key is pressed, the countdown timer will begin. NOTE: Sensors vary in the amount of time it takes to calibrate. Span calibration fails when the monitor does not detect any change in gas concentration. In the latter case, the Err (error) message appears on the screen, the monitor beeps and the LED lights up. In either case, begin span calibration again. When span calibration is complete, dn (done) and the real time reading briefly appear on the screen before advancing to the next submenu.

To interrupt and exit span calibration during the 90-second countdown, press the button and no appears on the screen. Press the button again to confirm and advance to the next submenu. span gas cylinder regulator calibration adapter Tygon or Teflon tubing 9

Changing Preset Limits or Span Gas Values High Alarm Low Alarm STEL TWA SPAN Example: Changing the High Alarm preset Cycle through the submenus by pressing the button once after each; stop at appropriate screen. (The monitor returns to the Monitor Mode after the span gas value.) The user will see SEt and go switch back and forth on the screen, prompting the user to change the preset limit or value. To change the preset, press and hold the button. Release when go stops flashing. The current preset will appear on the screen. The blinking digit is the one that will change. To change the digit, press the button and it will increase by one increment; the digits cycle from 0 through 9. To move to the next digit, hold the button down and release when the next digit starts blinking. To save the new limit, hold the button and release when dn appears on the screen. The monitor will advance to the next submenu. 10

Maintenance Replacing the Lithium Battery The ToxiRAE II is shipped with the Lithium battery installed. Change the battery when the low battery symbol appears. The alarm will beep and flash once a minute until a fresh battery is installed. Just before the battery dies, off will appear instead of the reading. The alarm will continue to beep, flash and vibrate for a minute until the battery is dead. CAUTION!! Change battery only in an area known to be nonhazardous. Step 1. Remove the battery compartment cover on the back of the detector. Step 1 Step 1 11

Step 2 Step 3 Step 2. Lift the ribbon out. Step 3. Using the ribbon, pull the battery out. Step 4. Replace the old battery using the orientation markers inside the battery compartment. Step 4 Warning!! Use only the following models of batteries: Tadiran TL 5955 EVE ER14335 12

Replacing the Sensor New sensors need to warm-up before first calibration and use. (See Table A for required warm-up times.) To replace the sensor, using the calibration adapter, remove the sensor cap. Then carefully remove the sensor by pulling straight out. Also remove the filter that is held in place with an o-ring, located in the ToxiRAE II housing above the sensor. Replace with a new sensor and filter. Replace the filter (P/N: 045-2045-000) when it appears dirty or when the sensor is replaced. (See Table A for sensor part numbers.) Sensors are not interchangeable; use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. Make sure the pins are not bent or corroded. Align the pins to the corresponding holes and push straight in. The sensor should fit flush against the PCB. 13

Specifications Size 3.6 (9.3 cm) x 1.9 (4.9 cm) x 0.9 (2.2 cm) Weight 3.6 oz (102 gm) with clip Battery User replaceable 2/3 AA high capacitance Lithium battery Operating Period 2 years typical battery life when use 8 hours/day with less than 5 minutes of alarms per day. 2 years typical sensor life for CO/H 2S sensors, all other sensors typical 1 year life Display Easy-to-read LCD for continuous display of concentration in ppm and text messages Keypad One button operation Direct Readout Instantaneous display of toxic gas concentration in ppm (or oxygen in %) STEL & TWA values Peak hold Alarms Audible: 90 db at 10 cm Visual: Bright Red/Green LED bar visible from top, front, and sides Sensory: Built-in vibration alarm High: Displays High emits 3 beeps and flashes per second Low: Displays Low 2 beeps and flashes per second STEL: Displays STEL 1 beep and flash per second TWA: Displays TWA 1 beep and flash per second Calibration Two point field calibration; Auto-zero at startup, user intiated span/standard reference gas. EMI/RFI Highly resistant to EMI / RFI. Compliant with EMC Directive 89/336/EEC IP Rating rating: protected against dust, protected against low pressure jets of water from all directions Hazardous Area UL/cUL Classified as Intrinsically Safe for use in Class I, Division 1 Groups A, Approval B, C, D, Hazardous Locations T5 rating ATEX II 1G, EEx ia IIB T5 II 2G, EEx ia IIC T5 European Conformity (Conformite Europene) Temperature Continuous: -4 to 114 F (-20 to 45 C) Intermittent: -40 to 131 F (- 40 to 55 C) Humidity 95% relative humidity (non-condensing) Attachments Wrist strap, stainless steel alligator clip (installed), stainless steel belt clip/ hardhat adapter Warranty 2-year warranty for instrument and CO/H 2S sensors (all other sensors have 1 year warranty) On going projects to enhance our products means that these specifications are subject to changes. 14

Table A: Sensor Configuration Sensors are not interchangeable; use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use only RAE Systems batteries. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. Sensor and Part Number NH 3 045-0518-000 CO 045-0512-000 CO 045-0512-200 Cl 2 045-0516-000 ClO 2 045-0523-000 HCN 045-0517-000 H 2 S 045-0511-000 NO 045-0514-000 NO 2 045-0515-000 O 2 045-0006-000 PH 3 045-0519-000 SO 2 045-0513-000 Range Resolution Span Gas Low High STEL TWA Sensor Warm-Up Time 0-50 1 50 25 50 35 25 4 hours 0-500 1 100 35 200 100 35 20 min 0-1999 10 100 35 200 100 3 20 min 0-10 0.1 10 0.5 5 1 0.5 20 min 0-1 0.01 0.5 0.2 0.5 0.3 0.1 20 min 0-100 1 10 4.7 50 4.7 4.7 20 min 0-100 1 25 10 20 15 10 20 min 0-250 1 25 25 50 25 25 4 hours 0-20 0.1 5 1 10 1 1 20 min 0-30 0.1 20.9% (air) 19.5 23.5 - - 20 min 0-5 0.01 5 1 2 1 0.3 20 min 0-20 0.1 5 2 10 5 2 20 min Call for availability Applies to newly installed sensor only. 15

16

Table B: Alarm Signals (H 2 S) Alarm Type Display Cause Buzzer & LED Vibration Alarm Over Range Reading > maximum range 3 beeps/sec once every second High Reading > High Alarm Limit 3 beeps/sec once every second Low Reading > Low Alarm Limit 2 beeps/sec once every second TWA TWA reading > TWA Limit 1 beep/sec once every second STEL STEL Reading > STEL Limit 1 beep/sec once every second Negative Reading < 0 ppm 1 beep/sec once every second Battery Low Battery < 3.2V 1 beep/min None Battery Dead Battery < 3.1V 1 beep/sec once every second 17

RAE Systems, Inc. Contact Information Main Office Telephone Fax Instrument Sales Email Website Technical Service 3775 North First Street San Jose, California 95134, USA 408.952.8200 408.952.8480 877.723.2878 RaeSales@raesystems.com www.raesystems.com 888.723.4800 Tech@raesystems.com SPECIAL NOTE: If the monitor needs to be serviced, contact either: the RAE Systems distributor where the unit was purchased; they will return the monitor on the user s behalf, or the RAE Systems Technical Service department. Before returning the unit for service or repair, obtain a Returned Material Authorization (RMA) number for proper tracking of your equipment. This number needs to be on all documentation and posted on the outside of the box in which the monitor is returned for service or upgrade. Packages without RMA Numbers will be refused at the factory.

ToxiRAE II Addendum To User Manual Rev B 04.2006

Physical Description 1 Bright red LED Alarm 2 Display 3 Audio Alarm 4 Gas Inlet 5 Button 6 Alligator Clip 7 Removable sensor cover (China and E.U. only) 6 1 2 5 4 3 7

Operating the ToxiRAE II Turning the Monitor ON (Firmware 1.4) Make sure the Lithium battery is installed. Hold the button down until you see the word on displayed, and then release it. You see the firmware version displayed briefly (for example, F15 means firmware version 1.5). The monitor performs a self-test preceding the warm-up and zero calibration. Then the current gas concentration reading is displayed. The ToxiRAE II is now operational. Turning the Monitor ON (Firmware 1.5) NOTE: Firmware version 1.5 is used on ToxiRAE II models equipped with sensors for CO, H 2 S, and O 2. Make sure the Lithium battery is installed. Hold the button down until you see the word on displayed, and then release it. You see the firmware version displayed briefly (for example, F15 means firmware version 1.5). The monitor performs a self-test preceding the warm-up. It counts down from 10 to 1, beeps, and vibrates. Then the current gas concentration reading is displayed. The ToxiRAE II is now operational.

Program Mode (v.1.5 only) Use the Program Mode to perform any of the following actions (listed in order of appearance): Calibrate the Monitor Change Alarm Limits To enter Program Mode, the instrument must first be turned off. Press the blue button rapidly, 3 times in succession. Pro appears in the display. Immediately hold the button down again until the display reads on. The display counts down and the buzzer, lights, and vibration alarms are tested. To exit Program Mode, press the button until Pro and End appear. Hold the button down for 5 seconds and release. The unit is now in Monitor Mode.

Replacing the Sensor (China & E.U. Only) ToxiRAE II models with a removable sensor cover allow you to change the sensor. Note: Removable sensor-cover versions are not available in the U.S. New sensors need to warm up before first calibration and use. (See Table A or Table B for required warm-up times.) To replace the sensor, use the calibration adapter to turn the sensor cap one quarter-turn counterclockwise. Next pull off the sensor cap. Then carefully remove the sensor by pulling it straight out. Also remove the filter that is held in place with an o-ring, located in the ToxiRAE II housing above the sensor. Replace these with a new sensor and filter. Replace the filter (P/N: 045-2045-000) when it appears dirty or when the sensor is replaced. (See Table A or Table B for sensor part numbers.) Sensors are not interchangeable. Use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. Make sure the pins are not bent or corroded. Align the pins to the corresponding holes and push the sensor straight in. The sensor should fit flush against the printed circuit board.

Table A: Sensor Configuration (U.S. Only) Sensors are not interchangeable; use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use only RAE Systems batteries. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. ToxiRAE II Model and Part Number NH 3 045-0518-000 CO 045-0512-000 CO 045-0512-200 Cl 2 045-0516-000 ClO 2 045-0523-000 HCN 045-0517-000 H 2 S 045-0511-000 NO 045-0514-000 NO 2 045-0515-000 O 2 045-0006-000 PH 3 045-0519-000 SO 2 045-0513-000 Range Resolution Span Gas Low High STEL TWA Sensor Warm-Up Time 0-50 1 50 25 50 35 25 4 hours 0-500 1 100 35 200 100 35 20 min 0-1999 10 100 35 200 100 35 20 min 0-10 0.1 10 0.5 5 1 0.5 20 min 0-1 0.01 0.5 0.2 0.5 0.3 0.1 20 min 0-100 1 10 4.7 50 4.7 4.7 20 min 0-100 1 25 10 20 15 10 20 min 0-250 1 25 25 50 25 25 4 hours 0-20 0.1 5 1 10 1 1 20 min 0-30 0.1 20.9% (air) 19.5 23.5 - - 20 min 0-5 0.01 5 1 2 1 0.3 20 min 0-20 0.1 5 2 10 5 2 20 min Call for availability. Applies to newly installed sensor only.

Table B: Sensor Configuration (China & E.U.) Sensors are not interchangeable; use only RAE Systems sensors, and use only the sensor type specified for your ToxiRAE II monitor. Use only RAE Systems batteries. Use of non-rae Systems components will void the warranty and can compromise the safe performance of this product. ToxiRAE II Model and Part Number NH 3 045-0518-x00 CO Range Resolution Span Gas Low High STEL TWA Sensor Warm-Up Time 0-50 1 50 25 50 35 25 4 hours 045-0512-x00 0-500 1 100 35 200 100 35 20 min CO 045-0512-X20 0-1999 10 100 35 200 100 35 20 min Cl 2 045-0516-x00 0-10 0.1 10 0.5 5 1 0.5 20 min ClO 2 045-0523-x00 0-1 0.01 0.5 0.2 0.5 0.3 0.1 20 min HCN 045-0517-x00 0-100 1 10 4.7 50 4.7 4.7 20 min H 2 S 045-0511-x00 0-100 1 25 10 20 15 10 20 min NO 045-0514- 0-250 1 25 25 50 25 25 4 hours x00 NO 2 045-0515-x00 0-20 0.1 5 1 10 1 1 20 min O 2 20.9% 0-30 0.1 045-0006-x00 (air) 19.5 23.5 - - 20 min PH 3 045-0519-x00 0-5 0.01 5 1 2 1 0.3 20 min SO 2 045-0513-x00 0-20 0.1 5 2 10 5 2 20 min Call for availability. Applies to newly installed sensor only. Use C for China and E for E.U.

Main Office Telephone Fax Instrument Sales Email Website Technical Service 3775 North First Street San Jose, CA 95134-1708 USA 408.952.8200 408.952.8480 877.723.2878 RaeSales@raesystems.com www.raesystems.com 888.723.4800 Tech@raesystems.com SPECIAL NOTE: If the monitor needs to be serviced, contact either: the RAE Systems distributor where the unit was purchased; they will return the monitor on the user s behalf, or the RAE Systems Technical Service department. Before returning the unit for service or repair, obtain a Returned Material Authorization (RMA) number for proper tracking of your equipment. This number needs to be on all documentation and posted on the outside of the box in which the monitor is returned for service or upgrade. Packages without RMA Numbers will be refused at the factory. Rev B 04.2006