Application Manual LT-6617 Rev. 1 July 2017

Similar documents
OpenBAS-HV-NX10 Series

OpenBAS-LC-NX12R. Lighting Controller. Installation Manual

OpenBAS-HV-VAVFC. HVAC Controller for Variable Air Volume Boxes and Fan and Coil Applications. Installation Manual

OpenBAS-HV-NXHALF HVAC Controller

OpenBAS-LC-NX12R. Lighting Controller. Installation Manual

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

CAREL heatersteam Electric Element Steam Humidifiers

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

DAP III Zone Master User s Guide

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

RAYCHEM NGC-30 COMPONENTS

IntesisBox BACnet/IP Server - Notifier ID3000 series

ModBus DE-1 INSTALLATION AND USER MANUAL

Installation Guide. Tracer ZN523 Zone Controller BAS-SVN003-E4

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

opti-visor ultra-efficient chiller plant automation Typical specification

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Virginia Tech Standards for Building Automation System

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Cultivator & Hybrid Cultivator

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

Connected Control (BCC100)

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Product Comparison Guide

Two-Channel Gas Controller

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

I/O ZONE 560/583 USERS GUIDE

HOME LOAD MANAGER INSTALLATION MANUAL Hardware Revision 1.4 & Higher

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

The ultimate fresh air solution.

1 Air Handling Units In ICE

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

WEBs AX Security. Integrated Security With Simple, Web-Based Management

Fan Coil Unit (FCU) Application Guide

VCM-X Controller Technical Guide

Water-cooled chillers with High Speed Centrifugal Compressors

STEAMPAK Series BurnerPAK BMS Burner Management Systems

7800 SERIES RM7888A Relay Module

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

design guide for wireless l i g h t i n g c o n t r o l

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Frequently asked questions: Intelligent Transmitter Series

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Gas Controller Module GC-06

Installation & Operation Manual

Introduction. What is the W2W Open controller?

Series 5000 Hydrazine Analyzer Model 60002

Product Specifications Dialog Room Controller* (*patent pending)

Flexible & Innovative. Cooling Solutions

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

NGC-40 Advanced Heat-Tracing Control System

Multi-Zone Wireless Control Training Systems ( )

Technical Data Submittal Document

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

OpenBAS-HV-NXSF. Building Automation Controller and HVAC Automation Solution. Installation Manual

SEQUENCE OF OPERATIONS

CATALOG NUMBER. Features. Description

T6984F,G Electronic Floating Control Thermostats

NetworX NX-548E Receiver Installation Instructions

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series.

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

TX3 Series TX3-CX-1. Installation Manual

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

INTREPID Perimeter Intrusion Detection System

ENERGY SAVING SEIBU GIKEN DST

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

AS950 REFRIGERATED SAMPLERS

Integrated Automation Instrumentation & Terminal Devices

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

NETWORK FIRE ALARM CONTROL PANEL. Features

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Temperature Controllers

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Fan Coil for AppController overview and specifications

TX3 Series ELEVATOR RESTRICTION SYSTEM. Installation Manual

Job Name Control Systems Description Date

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Ammonia Leak Detector Manual

Hydronic & HVAC Control Systems

MBCE-110/230UV Flame Sensor Module

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Transcription:

Application Manual LT-6617 Rev. 1 July 2017

Table of Contents 1.0 Frequently Asked Questions 4 2.0 OpenBAS Wiring Guidelines 6 3.0 Wiring 9 4.0 Glossary 11 3

1.0 Frequently Asked Questions 1.1 What is a Building Automation System? Building Automation Systems (BAS) are centralized, interlinked networks of hardware and software which monitor and control the environment in industrial, commercial, or residential applications. While managing various building systems, the automation system ensures optimal operational performance of the facility, comfort and safety of building occupants, and increases energy efficiency. 1.2 What is OpenBAS? Mircom s OpenBAS (Building Automation System) is a wide selection of UL/ULC listed controllers and supporting accessories that can be easily integrated into any industrial, commercial, or residential applications. OpenBAS delivers HVAC (heating, ventilation, and air conditioning), Lighting, Power Metering, and VAV Fan & Coil control to optimize comfort and energy management within a facility. OpenBAS controllers are programmable and configurable with advanced functions to accommodate any custom application. 1.3 Which systems in a building can OpenBAS control? OpenBAS delivers HVAC (heating, ventilation, and air conditioning), Lighting, Power Metering, and VAV Fan & Coil control to optimize comfort and energy management within a facility. 1.4 Is OpenBAS recognized by any listing agencies? OpenBAS equipment is certified by listing agencies, such as: UL, ULC, CSA, and FCC. 1.5 How many PLCs (Programmable Logic Controllers) can I have on my network? Depending on the network type, different capabilities are offered. TCP/IP networks have the number of devices limited by the number of IP addresses available on each network; however, routers can be used to span multiple networks allowing an unlimited number of devices. On RS-485 networks, the different protocols supported offer device capabilities between 127 and 250 devices on each individual sub network. 1.6 Can I integrate with 3rd party hardware such as fire panels, lighting controllers, etc.? OpenBAS supports main stream open protocols, allowing third party hardware and software to be integrated into OpenBAS networks. OpenBAS equipment can also be integrated into third party networks. 1.7 What are the 3rd party integration softwares available? Schneider s StruxureWare, NiagaraAX Framework, BACnet Explorer, Modbus poll, etc. 4

Frequently Asked Questions 1.8 Do I have access to the configuration library? The OpenBAS configurator software includes an EZ wizard application builder with prebuilt and ready-to-use solutions for applications in HVAC, mechanical rooms, lighting control, power metering, protocol conversion, etc. 1.9 Do I have to purchase the configurator tool or software? The OpenBAS configurator software is free to download from the Mircom website and includes all the modules required to configure and commission all OpenBAS. 1.10 Is the OpenBAS literature available online? Yes, OpenBAS literature is available for download on the Mircom website. www.mircom.com/building-automation-systems 1.11 What is the programming language? OpenBAS controllers can be programmed using ladder logic instructions; they also have integrated script compilers supporting multiple languages other than English. The script can be written in French, Spanish, German, Italian, and Dutch. The EZ wizard application builder creates initial templates of scripts ready to be compiled, downloaded to the controllers and further modified to meet the application requirements. 1.12 Is there a quoting tool? How many devices do I need in my building? There is a quoting tool available to recommend the base equipment and optional accessories required. Please contact our sales representatives to aid you in selecting the appropriate products to meet your needs. 1.13 What happens if there is a network outage? OpenBAS controllers are microprocessor-based and programmed individually so they can still operate when offline. 1.14 Does Mircom s OpenBAS include field devices such as chilled water valves, dampers, VAV controllers, and temperature thermostats? Mircom is an authorized distributor for Schneider products, which include valves, actuators, various sensors, VAV controllers, dampers, and thermostats. OpenBAS offers VAV controllers and temperature thermostats. 1.15 Are there any training modules for the OpenBAS system? Yes. Mircom offers both online and in-class training for OpenBAS. Part of the in-class training will include a free Learning Module (OpenBAS-HV-LEARN) coupled with the configuration software to provide simulated field scenarios. 5

2.0 OpenBAS Wiring Guidelines i Note: Wire in accordance with the Canadian Electrical Code or the National Electrical Code, and comply with all local regulations. Final acceptance is subject to the Local Authority Having Jurisdiction (AHJ). 2.1 USB 5 m (16 ft 5 ) for high speed devices 3 m (9 ft 10 ) for low speed devices 2.2 Ethernet 100 m (328 ft) 2.3 SPI Connection 28 AWG, 20 cm (8 ) 2.4 I2C Connection 28 AWG, 20 cm (8 ) 2.5 RS-485 for COM1, COM2 and COM3 Ports 22 AWG twisted pair, maximum length: 1219.2 m (4000 ft) Mircom recommends shielded cable. 2.6 RS-232 for COM1, COM2 and COM3 Ports 22 AWG twisted pair, maximum length: 15.24 m (50 ft) 2.7 Universal Inputs and Analog Outputs 18-22 AWG braided cable, maximum length: 10 m (30 ft) Unshielded twisted pair, maximum length: 18 m (50 ft) Shielded twisted pair, maximum length: 50 m (150 ft) For distances greater than 10 m, use individually jacketed cable for each input to prevent interference. In general, follow these guidelines: Use 18 AWG stranded wire. 6

OpenBAS Wiring Guidelines Limit the distance between the field device and the controller to 10 m (30 ft). Mircom recommends shielded wire for noisy environments. If this distance is not possible, longer wire runs with shielded wire are allowed up to 30 m (100 ft). Connect the shield to any 0V terminal on the controller, making sure to isolate the shield on the other end. Failing to do so creates ground loops. When possible, route the wiring inside metal piping and ground the piping for better results. Avoid running any analog signals near sources of electric noise such as: motors, ballasts, fluorescent lamps, variable frequency drives, high energy contacts, RF (radio frequency) transmitters, microwave ovens, and any other equipment that generates electromagnetic interference. Keep a minimum distance of 30 cm (1 ft) between analog output wiring and any conductor carrying more than 24 VAC. Fit the end of the wire with terminal connectors to provide a solid connection that can withstand temperature changes and vibration without becoming loose. Follow good wiring and installation practices, and follow all local regulations and electrical codes. 2.8 Digital Relay Outputs! Attention: Relay output connections can contain hazardous voltages that present the risk of electric shock. Exercise caution when handling these terminals. Only certified technicians should handle these terminals. 16-22 AWG braided cable, maximum length: 50 m (150 ft) The gauge depends on the current that the relay output provides, and on the maximum allowable voltage drop. This online voltage drop calculator can help select the maximum cable lengths for any given voltage, wire gauge and load: http://www.calculator.net/voltage-drop-calculator.html In the following example, a 5% voltage drop is obtained with a 5 A at 120 VAC which should be acceptable for most local electrical codes. Figure 1 Voltage Drop Calculator 2.9 Power supply 18-22 AWG braided cable, maximum length: 10 m (30 ft) Daisy chain power supplies, instead of using star connections, to avoid ground loops. 7

OpenBAS Wiring Guidelines 2.10 Wiring the Terminals The terminals are depluggable for ease of wiring. 2.10.1 Required Tools Tools needed: Precision or jeweler's screwdriver set Micro screwdriver, bladed, size: 0.4 x 2.0 x 60 mm (for ) Wire cutter Wire stripper 2.10.2 Installation Tips Perform visual inspection of circuit board and parts for obvious issues. Use a wire tie to group wires for easy identification and neatness. 2.11 Positioning Considerations for Wireless Devices If possible, orient each device so that it has line of sight with the devices it is communicating with. Do not install devices close to metal ducts or conduits. Do not install devices near large metal objects like refrigerators. The technician must use the commissioning software to determine that the receivers are linked to the transmitters. 8

3.0 Wiring Usually, only 1 controller is connected to the OpenBAS-HV-VAVFC. However, up to 4 controllers can be connected to the COM2 port of the OpenBAS-HV-VAVFC in order to obtain an average, minimum, or maximum values. To wire 4 controllers to an OpenBAS-HV-VAVFC 1. Wire the 4 controllers to COM2 of the OpenBAS-HV-VAVFC as shown in Figures 2 and 3. RS-485 wiring requirements 22 AWG twisted pair Maximum length: 1219.2 m (4000 feet) Mircom recommends shielded cable 24VAC or VDC Power Supply 24V 0V OpenBAS-HV-VAVFC, OpenBAS-HV-FCX, or OpenBAS-HV-VAVX 24V +12 0V COM2 d2- d2+ ref2 D- D+ Gnd +V address 1 D- D+ Gnd +V D- D+ Gnd +V D- D+ Gnd +V address 2 address 3 address 4 Figure 2 Wiring up to 4 over 24 VAC/VDC 9

Wiring 12VDC Power Supply 12V 0V OpenBAS-HV-VAVFC, OpenBAS-HV-FCX, or OpenBAS-HV-VAVX 24V +12 0V COM2 d2- d2+ ref2 D- D+ Gnd +V address 1 D- D+ Gnd +V D- D+ Gnd +V D- D+ Gnd +V address 2 address 3 address 4 Figure 3 Wiring up to 4 over 12 VDC 10

4.0 Glossary A B C Analog Input An analog input provides a value such as temperature, pressure, and flow. Normally this type of input represents the real value, for instance 21.5 C, 50 PSI, or 20.3 L/min. Analog Output An analog output controls speed, intensity or position of output devices or equipment. For example, it controls: The position of a modulating valve that can span between 0-100% to provide more or less water to a heating or cooling coil. The speed of a variable speed motor that can vary between 0-60 Hz. The mechanical position of an air damper that can be in any position, between fully closed to fully open spanning anywhere in the 0-100% range. The dimming value for a lamp that can vary its light intensity with a sliding control to any desired light intensity. Building Automation Controller (BAC) A Building Automation Controller is a device that incorporates all necessary inputs, outputs and communications to control all the aspects of a building, such as HVAC, energy metering and management, lighting, control of mechanical rooms such as chillers, boilers, and air handling units, and to provide the end user with comfort, good ambient lighting and ease of use. To the manager it is an easy and accurate way of controlling, programming, scheduling and monitoring these features. To the owner it means a reduced operating cost due to efficient use of HVAC equipment, lighting control and appropriate energy management. Building Automation System (BAS) A Building Automation system is a combination of hardware (controllers) and software that controls all aspects of a building, including HVAC, energy management, lighting, fire and safety, access control, CCTV, and security. Communication Port (or Fieldbus) A communication port is an RS-485 or RS-232 port which integrates industry standard protocols into the Building Automation Controller. 11

Glossary D Digital Input A digital (or binary) input represents the status of a device and can have only two states. For instance, a door can be open or closed, and a motor can be on or off. Digital Relay Output A digital relay (or binary) output operates loads and machinery. It can have only two states. For example: A single speed motor that can be only on or off. A smoke damper that can only be open or closed. A standard fluorescent lamp that can be only on or off. A door that can only be locked or unlocked. H HVAC HVAC (Heating, Ventilation, and Air Conditioning) refers to the mechanical equipment used to ventilate, filter, humidify, dehumidify, heat, and cool the air of an area within specified parameters. Some of the most common equipment includes: AHU Air Handling Units RTU Roof Top Unit, include AHU and Chiller in same unit Split/Mini-split Equipment with separate evaporator and condenser Water source / Heat Pump Equipment that supplies either hot or cold water VAV Variable Air Volume Boxes FCU Fan and Coil Units Chillers Equipment that cools water or air Boilers Equipment that heats water Heaters Equipment that heats air Humidifiers Equipment that adds moisture to air Dehumidifiers Equipment that removes moisture from air Compressors Equipment that provides clean, dry compressed air or that compresses refrigerant gases to generate cooling Fan/Ventilator Equipment that moves air Pump Equipment with a motor that circulates water P Programmable Logic Controller (PLC) Programmable logic controllers are computers that are used in the building automation industry to control and program inputs and outputs. 12

Glossary Pulse (or Frequency) Input A pulse input sends a binary signal (on/off) on a periodic basis. This signal represents a value that the Building Automation System totals over time. For example, a gas meter sends a pulse for every cubic feet consumed, a flow meter sends a pulse every time a liter flows, and a power meter sends a pulse for every kilowatt of energy consumed. This pulse is summed in a register that can represent the total amount of a given product consumed, or if time is added to the equation, it can represent values such as liters per minute (L/min), cubic feet per minute (ft 3 /min), or kilowatts per hour (kwh). R Remote Point A remote point is a value that does not reside physically in the Building Automation Controller but is acquired or commanded through a communication port that can be a Fieldbus port either wired through RS-485 or RS-232, wirelessly, or through a network interface card. U Universal Input (Analog, Digital or Pulse Input) A universal input is a digital or analog hardware input to the Building Automation Controller that measures any type of industry standard sensor such as: Dry contacts, magnetic contacts, mechanical on/off switches, push buttons, mechanical flow switches, mechanical pressure switches (digital). Pulse gas meters, pulse water flow meter, substation electrical pulse kw meter (frequency and pulse counters). Resistive temperature sensors, pressure sensors, lighting LUX sensors, voltage sensors, current sensors, thermocouples (analog). 13

14 Mircom 2017 Printed in Canada Subject to change without prior notice www.mircomgroup.com TECHNICAL SUPPORT North America Tel: (888) Mircom5 (888) 647-2665 International Tel: (905) 647-2665 U.S.A 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Tel: (888) 660-4655 (905) 660-4655 Fax: (905) 660-4113 CANADA - Main Office 25 Interchange Way Vaughan, ON L4K 5W3 Tel: (888) 660-4655 (905) 660-4655 Fax: (905) 660-4113