Synco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.

Similar documents
Synco-Gamma Application Guide. Retirement and nursing homes.

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

Application Guide siemens.com/thermostats

Room thermostat with KNX communications RDG100KN

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Room thermostat with KNX communications RDG400KN

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

Saving energy while ensuring an enhanced room climate

Room thermostat with KNX communications RDG400KN

Semi-flush mount communicating room thermostats RDF301, RDF , RDF600KN

Room thermostats with KNX communications RDG100KN, RDG160KN, RDG165KN

Save energy while maintaining a constant room climate

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

Room thermostats with KNX communications RDG100KN, RDG160KN

Room thermostats with KNX communications RDG100KN, RDG160KN, RDG165KN

Use of the application program

Devices for Special Applications

A comprehensive range of controllers, from stand-alone to communicating for any requirement. HVAC control with Synco Simple and energy-efficient

Semi flush-mount communicating room thermostats

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Installer Manual KNX Touchscreen Thermostat

Central apartment unit

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

Semi-flush mount room thermostats with KNX communications RDU341. Basic Documentation. Edition: 1.2. CE1P3172en Building Technologies

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Install intelligent room automation flexibly and future-proofed

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

Central apartment unit with QAX913 consumption data acquisition

Synco 900 Operating instructions

ADRIA intelligent room system

Room thermostats with LCD for wall mounting

Synco living Operating Instructions. Edition 3.0 Controller series C CE1B2707en Building Technologies

Synco 900 Operating Instructions. Edition 1.0 Controller series 1 CE1B2707en Building Technologies HVAC Products

Description of the application programme for KNX occupancy detectors version 3.1

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Siemens room thermostats. For maximal comfort and energy efficiency

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Product and Applications Description

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Saving energy with Synco

Electronic controllers. Comfort embellishes everyday life

Synco living Operating instructions. Building Technologies

RVL481. Heating Controller. including d.h.w. heating

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

PRELIMINARY EDITION

SAUTER ecos504/505. The modular room controller for demand-controlled, integral room automation.

Synco living combines individual room control with consumption data acquisition

Product Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution

Building and home evolution

Room Temperature Controller

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Optimal control for superior lighting performance

Flush-mounted room thermostat

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Wall-mounted room thermostat with LCD

UP 258E11 OPTISENS OFFICE

Application description

Heating and D.h.w. Controller RVL482 Basic Documentation

Desigo TM Room Automation The unique solution for enhanced comfort and productivity

Flush-mounted room thermostats

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

Semi flush-mount room thermostats

Touch Screen Flush-mount Room Thermostats with KNX Communications

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

e.control Function overview

Room thermostat with Auto Timer, Option External Input

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

Room thermostat with Auto Timer, Option External Input

RVL480. Heating Controller

Semi flush-mount room thermostat

Room thermostat with Auto Timer, Option External Input

Wireless room thermostat with LCD

Tebis application software

Web Services are based on Apache and Tomcat servers. The html/jsp (tags, beans) are fully customisable and extendable.

RVL470. Heating Controller. Use. Functions. Series B

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

RVP310. Heating Controller. Building Technologies HVAC Products

Tebis application software

0701 CO Light, HVAC, Monitoring, Brightness

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Product Comparison Guide

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

RVP360 and RVP361 Heating controllers for 2 heating circuits and d.h.w. Basic Documentation

And now: sit back and enjoy the presentation! elearning, ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Room Master

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

Hydronic & HVAC Control Systems

Smart Thermostat RDS110

Room thermostat with Auto Timer, Option External Input

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Room thermostats with LCD RDD100..

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

NEWS THEBEN THEBEN 2

Local Control Network - building controls in perfection

Applications in banks. Economically efficient, customer friendly and ready for the future with GAMMA building control. Answers for infrastructure.

Transcription:

Synco-GAMMA Application Guide Hotel buildings Answers for infrastructure.

Enhanced comfort and energy efficiency in hotels with Synco and GAMMA building systems Requirements Single source Types of integration Purpose of the document Structure of the document Synco with special group addresses Engineering notes Hotel buildings require special technical solutions. What is needed are low construction costs, a high level of flexibility to be able to easily rearrange spaces, economical operation and, naturally, excellent comfort for the guests. The buildings must ensure optimum working conditions, low energy consumption, safe operation, protection from damage, and security in emergency situations. Building systems based on conventional technology cannot satisfy most of these requirements. As a supplier of products and systems for all sectors of building automation and control, Siemens offers integrated, energy-efficient and tested solutions from the production of heat and cooling energy to individual room control and from energy distribution to the power outlet in the hotel room, thus meeting all requirements. There are different types of integrated applications: "Integrated room applications" comprise HVAC, lighting and shading control with the option of manual intervention from the room "Integrated room primary applications" comprise HVAC, lighting and shading control with the option of manual intervention from the room, but also including a connection to primary plant, which ensures optimum communication between the room and the heating/refrigeration plant guaranteeing maximum energy efficiency The present Application Manual describes 7 variants of a guest room in a hotel and one variant each of lobby, restaurant, fitness room, and primary plant. With all applications, the focus is placed on energy efficiency and comfort. The different variants offer room automation with fan coil units, radiators and floor heating systems as well as ventilation and VAV plant with a host of products from Siemens KNX range: From simple solutions with fan coil units including switching of electric circuits to VAV systems for larger rooms with automatic lighting and blind control. Manual control is always possible. There is no need to worry about energy savings since these are automatically ensured by the system. Moreover, the best climatic and lighting conditions are guaranteed for all sections of the hotel. Each application variant is subdivided into the following sections: Features/benefits Room setup Device list Function description Secondary documents Synco devices use standard group addresses to distribute system time and information about plant malfunctions. When an application program is downloaded to the Synco devices via ETS, the group addresses are deleted. For this reason, the special group addresses must be downloaded via ETS. Otherwise, the Synco devices will not be able to communicate. The group addresses can be downloaded from the Internet at www.siemens.com/knx-td This document describes examples of room applications and makes proposals for their implementation. For configuration and parameterization of the individual devices, please refer to the respective application and function sheets which can be downloaded from the Internet at www.siemens.com/hit or www.siemens.com/knx-td 3

Summary No. Functions Benefits Page 1 Fan coil unit, radiator, lighting, sun protection (hotel room) Heating and cooling, 1 control loop: Automatic or manual fan control, 1- or 3- speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection and power supply to the room Dimming and switching of lighting Operation and display of HVAC Simple and flexible installation thanks to wireless technology Pushbuttons for "SOS", "Make up room" and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Efficiency class B 11 Individual room temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Presence-dependent control of lighting and power supply saves electrical energy. Time- and daylight-dependent shading control saves heating/cooling energy when the room is not occupied. Display of energy efficiency saves energy: Facility manager and personnel are informed about energy waste and error messages (e.g. open windows during nonoccupancy times). Installation: Straightforward and flexible thanks to wireless technology saves time and material. 2 Fan coil unit, radiator, lighting, sun protection (hotel room) Heating and cooling, 2 control loops: Automatic or manual fan control, 1- or 3- speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Operation of HVAC Simple and flexible installation thanks to wireless technology Pushbuttons for "SOS", "Make up room" and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Efficiency class B 16 Individual room temperature control and automatic data exchange with primary plant together save up to 30% heating/ cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. eu.bac-certified room temperature controller guarantees high control accuracy and reliability and, in addition, saves heating/ cooling energy. Separate temperature control in the bathroom ensures enhanced comfort and longer life of facilities. Presence-dependent control of lighting and power supply saves electrical energy. Time- and daylight-dependent shading control saves heating/cooling energy when the room is not occupied. Display of energy efficiency saves energy: Facility manager and personnel are informed about energy waste and error messages (e.g. open windows during nonoccupancy times). Installation: Straightforward and flexible thanks to wireless technology saves time and material. 4

3 Fan coil unit, radiator, lighting, sun protection (hotel room) Heating and cooling, 2 control loops: Individual room temperature control, heating and cooling 2 control loops for room and bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via presence detector and door contact Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room" and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Efficiency class B 21 Individual room temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. eu.bac-certified room temperature controller guarantees high control accuracy and reliability and, in addition, saves heating/cooling energy. Separate temperature control in the bathroom ensures enhanced comfort and longer life of facilities. Presence-dependent control of lighting and power supply saves electrical energy. Automatic detection of occupancy ensures enhanced comfort. Time- and daylight-dependent shading control saves heating/cooling energy when the room is not occupied. Display of energy efficiency saves energy: Facility manager and personnel are informed about energy waste and error messages (e.g. open windows during nonoccupancy times). 4 Fan coil unit, radiator, lighting, sun protection (hotel room) Heating and cooling, 1 control loop: Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Operation and display of HVAC Pushbuttons for "SOS", "Make up room" and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Efficiency class B 26 Individual room temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Presence-dependent control of lighting and power supply saves electrical energy. Time- and daylight-dependent shading control saves heating/cooling energy when the room is not occupied. Display of energy efficiency saves energy: Facility manager and personnel are informed about energy waste and error messages (e.g. open windows during nonoccupancy times). 5

5 Fan coil unit, radiator, lighting (hotel room) Heating and cooling, 1 control loop: Individual room temperature control, heating and cooling One control loop for room and bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection and power supply to the room Operation and display of HVAC Pushbuttons for "SOS", "Make up room" and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Efficiency class C 31 Individual room temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Presence-dependent control of lighting and power supply saves electrical energy. Display of energy efficiency saves energy: Facility manager and personnel are informed about energy waste and error messages (e.g. open windows during nonoccupancy times). 6 Radiator, lighting, sun protection (hotel room) Heating, 2 control loops: Individual room temperature control, heating Two control loops for room and bathroom Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room" and "Do not disturb" Efficiency class B 35 Time- and presence-dependent individual room temperature control saves up to 20% heating energy. Separate temperature control in the bathroom ensures enhanced comfort and longer life of facilities. Presence-dependent control of lighting and power supply saves electrical energy. Time- and daylight-dependent shading control saves heating energy when the room is not occupied. 7 Floor heating, lighting, sun protection (hotel room) Heating, 2 control loops: Individual room temperature control, heating Two control loops for room and bathroom Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room" and "Do not disturb" Efficiency class B 39 Time- and presence-dependent individual room temperature control saves up to 20% heating energy. Separate temperature control in the bathroom ensures enhanced comfort and longer life of facilities. Presence-dependent control of lighting and power supply saves electrical energy. Time- and daylight-dependent shading control saves heating energy when the room is not occupied. 6

8 Air conditioning plant, indoor air quality control, lighting (reception area) Heating and cooling, indoor air quality control Room-supply air temperature control/co 2 control Automatic data exchange between room HVAC and primary plant VAV controllers for optimization of ventilation system Remote control of individual rooms or room groups Demand-compensated production of heat and cooling energy thanks to automatic data exchange with heating and refrigeration controller Constant light control Efficiency class A conforming to EN 15232 Efficiency class A 43 Temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Demand-compensated ventilation saves 20% to 70% ventilation energy. Time-, presence- and brightness-dependent control of lighting saves up to 45% light energy. Monitoring of operating times and error messages from the lighting system ensure reliability. Display of energy efficiency saves energy: Fault status messages are sent to the facility manager and to personnel. 9 VAV plant, indoor air quality control, lighting, and sun protection (restaurant area) Heating and cooling, indoor air quality control Fully integrated VAV application with temperature, CO 2 and volumetric air flow control Automatic data exchange between room HVAC and primary plant VAV controllers for optimization of ventilation system Remote control of individual rooms or room groups Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Constant light control Efficiency class A conforming to EN 15232 Efficiency class A 47 Temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Demand-compensated ventilation saves 20% to 70% ventilation energy. Time-, presence- and brightness-dependent control of lighting saves up to 45% light energy. Monitoring of operating times and error messages from the lighting system ensure reliability. Time- and daylight-dependent shading control saves up to 30% heating/cooling energy. Display of energy efficiency saves energy: Fault status messages are sent to the facility manager and to personnel. 7

10 VAV plant, indoor air quality control, lighting, sun protection (fitness room) Heating and cooling, indoor air quality control Fully integrated VAV application with temperature, CO 2 and volumetric air flow control Automatic data exchange between room HVAC and primary plant VAV controllers for optimization of ventilation system Remote control of individual rooms or room groups Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Constant light control Efficiency class A conforming to EN 15232 Efficiency class A 53 Temperature control and automatic data exchange with primary plant together save up to 30% heating/cooling energy. Time- and presence-dependent temperature control saves up to 20% heating/cooling energy. Demand-compensated ventilation saves 20% to 70% ventilation energy. Time-, presence- and brightness-dependent control of lighting saves up to 45% light energy. Monitoring of operating times and error messages from the lighting system ensure reliability. Time- and daylight-dependent shading control saves up to 30% heating/cooling energy. Display of energy efficiency saves energy: Fault status messages are sent to the facility manager and to personnel. 11 Primary plant Efficiency class A 58 Preparation of heat, refrigeration and air Demand-compensated production of heat, cooling energy and supply air Setpoint compensation based on demand and outside temperature Together with room automation: Prerequisite to attain efficiency class A conforming to EN 15232 Temperature control and automatic data exchange with all rooms together save up to 30% heating/cooling energy. Time- and demand-dependent temperature control saves up to 20% heating/cooling energy. Demand-compensated ventilation saves 20% to 70% ventilation energy. Display of energy efficiency saves energy: Fault status messages are sent to the facility manager and to personnel. 8

Scenarios for hotel rooms For hotel rooms, the following usage scenarios are considered realistic: HVAC A typical HVAC scenario could look as follows: When a room is not occupied, it operates continuously in Economy mode. The moment the guest checks in, the hotel reservation system switches the room s operating mode from Economy to Precomfort. As long as the room is not occupied, its temperature is maintained at the Precomfort setpoint (20 C for heating/26 C for cooling). When the guest enters the room, its temperature is raised to the Comfort level of 21 C in the case of heating/lowered to 24 C in the case of cooling, and then lowered/raised again when the guest leaves the room. When checking out, the room s operating mode is reset to Economy. The guest can adjust the Comfort setpoint to meet his/her individual needs. But when automatically switching to another operating mode, the setpoints are reset to those of the room group. Lighting A typical lighting scenario could look as follows: When the hotel card is inserted, the basic lighting is switched on. Then, other lights can be switched on manually via the pushbuttons. When leaving the room, all lights are automatically turned off after a certain period of time. Shading A typical blinds scenario could look as follows: When the room is not occupied, the blinds are controlled automatically. In the winter after sunrise, the blinds are automatically raised, allowing solar heat to enter the room. On the other hand, when, in the summer, the sun shines on the façade, the blinds are lowered to protect the room from solar heat. For safety reasons, the blinds are automatically lowered after sunset. When the room is occupied, it is up to the guest to control the blinds. Then, automatic operation is deactivated and the blinds can be controlled via the pushbuttons or the room operator unit. 9

Hotel-specific functions The functions described below are used primarily in hotels: SOS Alarm function The alarm function can be triggered via pushbutton. When pressed, a signal is sent to the management station. The alarm can be visualized on a suitable display unit (touch panel or webbrowser) or on a panel with signal lamp. The operating elements provided are rockers with "Bell" symbol and pull cords. MUR Make up room The MUR function is activated via pushbutton. When pressed, a signal is sent to the management station. The signal can be displayed on a suitable display unit (touch panel or webbrowser) or can be indicated by a signal lamp on a panel. DND Do not disturb The DND function is triggered via pushbutton. Indication is by signal lamp, inside and outside the room. Minibar Monitoring of minibar Monitoring of the minibar can be implemented by a window contact fitted to the door of the minibar and a pushbutton interface. When the minibar door is opened, a signal is sent to the management station and logged on the UP 588 touch panel as a trend. When using Synco 700 devices (RMB795B, RMS705B), opening the door can either be counted or logged as an event. In each case, 4 channels available. Hotel booking system Integration in hotel booking system Integration of an OPC server with suitable, commercially available software facilitates the connection from the KNX bus to the Micros Fidelio/Opera hotel management system. This makes it possible to automatically switch the hotel room s operating mode when guests check in or out, or based on the booking plan. Fire protection and smoke extraction Shutdown, ventilation or smoke extraction in the event of fire Use of the central control unit RMB795B in connection with the fan coil unit applications allows ventilation to be automatically shut down in the case of fire or to switch on smoke extraction, if required. The sensors are connected directly to the RMB795B. The respective signal is forwarded to the ventilation controller (RMU7x0B) via the KNX bus. On VAV applications, the signal is also fed to the room thermostat or the VAV controllers, which ensure that the VAV dampers will be correctly closed or opened. 10

Application Manual Nr. 01 Fan coil unit with radiator in the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating and cooling One control loop for the room and the bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Operation and display of HVAC Simple and flexible installation thanks to wireless technology Pushbuttons for "SOS", "Make up room", and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Room setup 1. Room thermostat RDF600KN: The RDF600KN acquires the room temperature and controls the fan coil unit and the radiator in the bathroom accordingly. The room operating mode can be selected and the temperature setpoints can be adjusted on the room thermostat. 2. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. 3. AP 641 room control box: The AP 641 features 8 sockets for room automation modules type RS or RL. 4. RS 525/23 universal dimmer: The RS 525/23 features a relay contact to dim a lighting group up to 250 VA. 5. RL 521/23 blind actuator: The RL 521/23 features 2 relay contacts to control blinds. 6. RS 510/23 binary output, 2-fold: The RS 510/23 features 2 relay contacts to switch electric circuits. 7. RXZ97.1 gateway EnOcean/KNX: The RXZ97.1 converts EnOcean wireless signals from the wall transmitter to KNX telegrams. 11

Application Manual Nr. 01 8. EnOcean window contact (3rd party product): The window contact causes the room operating mode to switch to Economy when the window is open. 9. EnOcean hotel card switch (3rd party product): When the card is inserted, the hotel card switch causes the room operating mode to change from Precomfort to Comfort. When the card is removed, the room operating mode returns to Precomfort. Electric circuits and lighting groups are switched off. 10. AP 221 wall transmitter EnOcean, 1-fold, neutral: The AP 221 is used to control the lighting, the blinds, the MUR (Make up room) and the alarm function (SOS). 11. DELTA pushbutton, 1-fold: The DELTA pushbutton activates signal lamp DND (Do not disturb) outside and inside the room. Device list Key Product no. and description Stock number 1 RDF600KN room thermostat S55770-T293 2 STA23 electrothermal actuator S55174-A101 3 AP641 room control box 5WG1 641-3AB01 4 RS 525/23 universal dimmer, 1 x 250 W 5WG1 525-2AB23 5 RL 521/23 blind actuator, 1 x 6 A 5WG1 521-4AB23 6 RS 510/23 binary output, 2 x 10 A 5WG1 510-2AB23 7 RXZ97.1 gateway EnOcean/KNX S55842-Z101 8 EnOcean window contact 3rd party product 9 EnOcean hotel card switch 3rd party product 10 AP 221 wall transmitter EnOcean, 1-fold, neutral 5WG4 221-3AB10 11 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 Optional Key Product no. and description Stock number 12 RMB795B central control unit S55370-C162 C167 13 OZW772.x webserver OZW772.x 14 N125/12 power supply 5WG1 125-1AB12 15 AP257/32 weather station 5WG1 257-3AB32 16 N151 IP viewer 5WG1 151-1AB01 17 UP588 color touch panel 5WG1 588-2AB13 Variants Key Product no. and description Stock number 1a RDF301.50 room thermostat S55770-T105 1b RDG160KN room thermostat (DC fan output) S55770-T297 1c RDG100 KN S55770-T163 3a AP 118 automation module box 5WG1 118-4AB01 4a UP 525/13 universal dimmer, 1 x 250 W 5WG1 525-2AB13 5a UP 520/13 blind actuator, 1 x 6 A 5WG1 520-2AB13 6a UP 510/13 binary output, 2 x 10 A 5WG1 510-2AB13 12

3191S03 Application Manual Nr. 01 HVAC control B2 T Y1 M1 T (B1) 2-pipe fan coil unit with radiator Heating or cooling On/off, PWM or 3-position control of heating/cooling and radiator actuators Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Multifunctional inputs for keycard contact, external sensor, etc. T (B1) YR T N1 TAAC01 DG1 HQ The temperature in every room is acquired and controlled. Every room sends its heat/cooling energy request to the heating/refrigeration plant. These plants are controlled depending on the outside temperature and the heat/cooling energy requests received from the rooms. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered/raised to save heating/cooling energy. The room temperatures are also slightly lowered/raised during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching lighting off when the room is not occupied. Blinds control When a room is not booked (or, if desired, when the guest is absent), a weather station outside the building protects up to 4 façades from extreme sunlight in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences. On sunny winter days, the weather station raises the blinds to let solar radiation make a natural heat contribution. When the guest is present, the blinds can be controlled via the pushbuttons and automatic operation is off. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 13

Application Manual Nr. 01 Function description Description of functions Individual room temperature control The room thermostat (RDF) acquires the temperature, controls it via the fan coil unit and calculates the demand for heat or cooling energy. The resulting signal is forwarded to the primary controller via the KNX bus. Time program and hotel booking system Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Window contact If one or several windows of a room are opened, the operating mode changes automatically to Economy. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Presence-dependent heating control When the presence detector (hotel card switch) signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Economy level. Presence-dependent lighting control When the room is no longer occupied, lighting is automatically switched off. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be operated via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current state of windows and doors Current room temperatures Current room temperature setpoints Current operating modes If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. 14

Application Manual Nr. 01 Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms TAAC01 DG1 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ 2-pipe fan coil unit with radiator Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser RDG100KN RMB795B OZW772 GAMMA Application Sheet, Lighting L00001 N5 HQ GAMMA Application Sheet, Shading B00002 AP2 HQ Central and manual switching of lighting N 512/11 Shading of façades AP 257/32 15

Application Manual Nr. 02 Fan coil unit with radiator in the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating and cooling 2 control loops for room and bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Operation of HVAC Simple and flexible installation thanks to wireless technology Pushbuttons for "SOS", "Make up room", and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Room setup 1. QAX98.4 solar room unit: The QAX98.4 acquires the room temperature. The 2 knobs are used to adjust the room temperature setpoint and to select the operating mode (present/absent). 2. RXB21.1 room controller: The RXB21.1 controls the room temperature via the fan coil unit. It receives the setpoint information from the room unit. 3. AQR2532 room sensor with AQR2570 basic module: The AQR acquires and controls the room temperature in the bathroom via the radiator. 4. AP 562/02 valve actuator: The AP 562/02 drives the radiator valve in the bathroom. It receives the positioning signal from the AQR controller. 5. AP 641 room control box: The AP 641 features 8 sockets for room automation modules type RS or RL. 6. RS 525/23 universal dimmer: The RS 525/23 features a relay contact to dim a lighting group up to 250 VA. 16

Application Manual Nr. 02 7. RL 521/23 blind actuator: The RL 521/23 features 2 relay contacts to control blinds. 8. RS 510/23 binary output, 2-fold: The RS 510/23 features 2relay contacts to switch electric circuits. 9. RXZ97.1 gateway EnOcean/KNX: The RXZ97.1 converts EnOcean wireless signals from the wall transmitter to KNX telegrams. 10. EnOcean window contact (3rd party product): The window contact causes the room operating mode to switch to Economy when the window is open. 11. EnOcean hotel card switch (3rd party product): When the card is inserted, the hotel card switch causes the room operating mode to change from Precomfort to Comfort. When the card is removed, the room operating mode returns to Precomfort. Electric circuits and lighting groups are switched off. 12. AP 221 wall transmitter EnOcean, 1-fold, neutral: The AP 221 is used to control the lighting, the blinds, the MUR (Make up room) and the alarm function (SOS). 13. AP 222 wall transmitter EnOcean, 2-fold, with "I/0" symbol: The AP 222 is used to control the lighting. 14. AP 222 wall transmitter EnOcean, 2-fold, with "Up/Down" symbol: The AP 222 is used to control the blinds. 15. DELTA pushbutton: The DELTA pushbutton activates signal lamp DND (Do not disturb) outside and inside the room. In the bathroom, it switches the lighting. Device list Key Product no. and description Stock number 1 QAX98.4 solar room unit S55623-H107 2 RXB21.1 room controller BPZ:RXB211-FC-10 3 AQR2570 room sensor, basic module S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 4 AP 562/02 valve actuator 5WG1 562-7AB02 5 AP 641 room control box 5WG1 641-3AB01 6 RS 525/23 universal dimmer, 1 x 250 W 5WG1 525-2AB23 7 RL 521/23 blind actuator, 1 x 6 A 5WG1 521-4AB23 8 RS 510/23 binary output, 2 x 10 A 5WG1 510-2AB23 9 RXZ97.1 gateway EnOcean/KNX S55842-Z101 10 EnOcean window contact 3rd party product 11 EnOcean hotel card switch 3rd party product 12 AP 221 wall transmitter EnOcean, 1-fold, neutral 5WG4 221-3AB10 13 AP 222 wall transmitter EnOcean, 2-fold, with "I/0" symbol 5WG4 222-3AB11 14 AP 222 wall transmitter EnOcean, 2-fold, with "Up/Down" symbol 5WG4 222-3AB12 15 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 Optional Key Product no. and description Stock number 16 RMB795B central control unit S55370-C162 C167 17 OZW772.x webserver OZW772.x 18 N 125/12 power supply 5WG1 125-1AB12 19 AP 257/32 weather station 5WG1 257-3AB32 20 N 151 IP viewer 5WG1 151-1AB01 21 UP 588 color touch panel 5WG1 588-2AB13 17

Application Manual Nr. 02 Variants Key Product no. and description Stock number 5a AP 118 automation module box 5WG1 118-4AB01 6a UP 525/13 universal dimmer, 1 x 250 W 5WG1 525-2AB13 7a UP 520/13 blind actuator, 1 x 6 A 5WG1 520-2AB13 8a UP 510/13 binary output, 2 x 10 A 5WG1 510-2AB13 Room HVAC control 4-pipe fan coil unit Heating and cooling with hot or chilled water Modulating control of heating and cooling valve Automatic or manual fan control XFNC04 B21 HQ The temperature in every room is acquired and controlled. Every room sends its heat/cooling energy request to the heating/refrigeration plant. These plants are controlled depending on the outside temperature and the heat/cooling energy requests received from the rooms. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered/raised to save heating/cooling energy. The room temperatures are also lowered/raised during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting and individual electric circuits off when guests are not present. Blinds control When a room is not booked (or, if desired, when the guest is absent), a weather station outside the building protects up to 4 façades from extreme sunlight in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences. On sunny winter days, the weather station raises the blinds to let solar radiation make a natural heat contribution. When the guest is present, the blinds can be controlled via the pushbuttons and automatic operation is off. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 18

Application Manual Nr. 02 Function description Description of functions Individual room temperature control The room unit (QAX) acquires the temperature and makes it available to the room controller (RXB) which controls the fan coil unit and calculates the demand for heat/refrigeration. The result of the calculation is sent to the primary controller via the KNX bus. In the bathroom, the AQR acquires and controls the temperature and feeds the positioning signal to the radiator s valve actuator. Time program and hotel booking system Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Window contact If one or several windows of a room are opened, the operating mode changes automatically to Protection. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Presence-dependent heating control When the hotel card switch signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Precomfort level. Presence-dependent lighting control When the room is no longer occupied, the lighting and individual electric circuits are automatically switched off. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current state of windows and doors Current room temperatures Current room temperature setpoints Current operating modes If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. 19

Application Manual Nr. 02 Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms XFNC04 B21 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ 4-pipe fan coil unit Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser RXB21.1 RMB795B OZW772 GAMMA Application Sheet, Lighting L00001 N5 HQ GAMMA Application Sheet, Shading B00002 AP2 HQ Central and manual switching of lighting N 512/11 Shading of façades AP 257/32 20

Application Manual Nr. 03 Fan coil unit with radiator in the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating and cooling Two control loops for the room and the bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via presence detector and door contact Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room", and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Room setup 1. UP 204 Contouch room controller: The UP 204 acquires the room temperature and sends temperature, setpoint shift, operating mode and fan speed commands to the RXB room controller via the KNX bus. The Contouch room controller can also be used to control the lighting and the blinds. 2. RXB21.1 room controller: The RXB21.1 controls the room temperature via the fan coil unit. If required, the room thermostat sends a heat/cooling energy request to the primary controller. 3. AQR2532 room sensor with AQR2570 basic module: Der AQR acquires and controls the room temperature in the bathroom via the radiator. 4. AP 562/02 valve actuator: The AP 562/02 drives the radiator valve in the bathroom. It receives the positioning signal from the AQR controller. 5. S 290 door/window contact: The window contact causes the room operating mode to change to Protection when the window is open. 6. N 528/31 universal dimmer, main module: The N528/31 features a channel to control a lighting group up to 300 VA. 21

Application Manual Nr. 03 7. N 512/11 switching actuator, main module: The N 512/11 features 3 potentialfree relay contacts to control lighting groups and electric circuits. 8. N 523/02 blind actuator: The N 523/02 features 4 channels to control up to 4 blind motors. 9. UP 222/2 pushbutton, 2-fold, neutral: The UP 222/2 is used to control the lighting and/or the shading. 10. DELTA pushbutton: The pushbutton is connected to the KNX interface of the AQR and is used to control the lighting. 11. DELTA pushbutton with "Bell" symbol (SOS): The pushbutton is used to trigger the alarm function. 12. UP 258D11 presence detector with brightness sensor: The UP 258D11 in connection with the S 290 door contact detects whether a guest is present or absent. When present, the presence detector causes the room operating mode to change from Precomfort to Comfort and electric circuits are switched on. When absent, the room operating mode returns to Precomfort. Electric circuits and lighting groups are switched off. 13. S 290 door/window contact: The door contact in connection with the UP 258D11 causes the room operating mode to change to Comfort/Precomfort when the guest is present/absent. 14. DELTA pushbutton, 2-fold, with labeling field (MUR, DND): One of the pushbuttons can be used to activate signal lamp DND (Do not disturb) outside and inside the room. The other pushbutton is used to activate the MUR function (Make up room). This signal is sent to the KNX bus via pushbutton interface UP 220. Device list Key Product no. and description Stock number 1 UP 204 Contouch room controller 5WG1 204-2AB11 2 RXB21.1 room controller BPZ:RXB211-FC-10 3 AQR2570 room sensor, basic module S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 4 AP 562/02 valve actuator 5WG1 562-7AB02 5 S 290 door/window contact 5WG1 290-7AB11 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 6 N 528/31 universal dimmer, main module, 1 x 300 W 5WG1 528-1AB31 7 N 512/11 switching actuator, main module, 3 x 16 A 5WG1 512-1AB11 8 N 523/02 blind actuator, 4 x 6 A 5WG1 523-1AB02 9 UP 222/2 pushbutton, 2-fold, neutral 5WG1 222-2DB12 UP 117/12 bus coupling unit (BTM) 5WG1 117-2AB12 10 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 11 Rocker, with "Bell" symbol (SOS) 5TG6 207 UP 116/21 DELTA bus coupling unit, 1-fold 5WG1 116-2AB01 12 UP 258D11 presence detector with brightness sensor 5WG1 258-2DB11 13 S 290 door/window contact 5WG1 290-7AB11 14 Rocker, double, with labeling field (MUR, DND) 5TG6 212 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 22

Application Manual Nr. 03 Optional Key Product no. and description Stock number 15 RMB795B central control unit S55370-C162 C167 16 OZW772.x webserver OZW772.x 17 N 125/12 power supply 5WG1 125-1AB12 18 AP 257/32 weather station 5WG1 257-3AB32 19 N 151 IP viewer 5WG1 151-1AB01 20 UP 588 color touch panel 5WG1 588-2AB13 21 N 528/41 universal dimmer, extension, 1 x 300 W 5WG1 528-1AB41 22 N 512/21 switching actuator, extension, 3 x 16 A 5WG1 512-1AB21 Variants Key Product no. and description Stock number 1a QMX3.P37 room operator unit, display and operation, temperature S55624-H108 3a QMX3.P70 room operator unit, temperature, humidity, CO 2 S55624-H104 6a UP 525/13 universal dimmer, 1 x 250 W 5WG1 525-2AB13 UP 221/2 pushbutton, 1-fold, neutral 5WG1 221-2DB12 7a UP 510/13 binary output, 2 x 10 A 5WG1 510-2AB13 UP 222/2 pushbutton, 2-fold, neutral 5WG1 222-2DB12 8a UP 520/13 blind actuator, 1 x 6 A 5WG1 520-2AB13 UP 221/2 pushbutton, 1-fold, neutral 5WG1 221-2DB12 12a/13a DELTA hotel card switch with insert 5TG4 820 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 Room HVAC control 4-pipe fan coil unit Heating and cooling with hot and chilled water Modulating control of heating and cooling valve Automatic or manual fan control XFNC04 B21 HQ The temperature in every room is acquired and controlled. Every room sends its heat/cooling energy request to the heating/refrigeration plant. These plants are controlled depending on the outside temperature and the heat/cooling energy requests received from the rooms. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered/raised to save heating/cooling energy. The room temperatures are also lowered/raised during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. Blinds control 23

Application Manual Nr. 03 When a room is not booked (or, if desired, when the guest is absent), a weather station outside the building protects up to 4 façades from extreme sunlight in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences. On sunny winter days, the weather station raises the blinds to let solar radiation make a natural heat contribution. When the guest is present, the blinds can be controlled via the pushbuttons and automatic operation is off. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. Function description Description of functions Individual room temperature control The room operator unit (UP 204) acquires the temperature and makes it available to the room controller (RXB) which controls the fan coil unit and calculates the demand for heat/refrigeration. The result of the calculation is sent to the primary controller via the KNX bus. Time program and hotel booking system Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Presence-dependent heating control When the presence detector signals room occupancy, the room temperature is raised or lowered to the Comfort level. When the guest leaves the room by opening the door, the door contact as the last device sends a signal, causing the room temperature to be lowered or raised to the Precomfort level. Presence-dependent lighting control When the room is no longer occupied, the lighting is automatically switched off. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current state of windows and doors Current room temperatures Current room temperature setpoints Current operating modes If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. 24

Application Manual Nr. 03 Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms XFNC04 B21 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ GAMMA Application Sheet, Lighting L00002 N5 HQ 4-pipe fan coil unit Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser Daylight- and presence-dependent switching of lighting RXB21.1 RMB795B OZW772 UP258D11 GAMMA Application Sheet, Shading B00002 AP2 HQ Shading of façades AP 257/32 25

Application Manual Nr. 04 Fan coil unit with radiator in the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating and cooling One control loop for the room and the bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Dimming and switching of lighting Operation and display of HVAC Pushbuttons for "SOS", "Make up room", and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Room setup 1. RDG100KN room thermostat: The RDG100KN acquires the room temperature and controls the fan coil unit and the radiator in the bathroom accordingly. The room operating mode can be selected and the temperature setpoints can be adjusted on the room thermostat. 2. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. 3. DELTA hotel card switch: When the card is inserted, the hotel card switch causes the room operating mode to change from Economy to Comfort and electric circuits are switched on. When the card is removed, the room operating mode returns to Economy. Electric circuits and lighting groups are switched off. 4. N 528/31 universal dimmer, main module: The N528/31 features a channel to control a lighting group up to 300 VA. 26

Application Manual Nr. 04 5. N 502/02 combi switching actuator: The N 502/02 features 8 inputs and 8 relay contacts. It is used to switch electric circuits and lighting groups and serves the pushbuttons as a KNX interface. 6. N 523/02 blind actuator: The N 523/02 features 4 channels to control up to 4 blind motors. 7. S 290 door/window contact: The window contact causes the room operating mode to change to Economy when the window is open. 8. DELTA pushbutton: The pushbutton is connected to the N 502/02 and used to control the lighting, the blinds, etc. 9. DELTA pushbutton with "Bell" symbol (SOS): The pushbutton is used to trigger the alarm function. 10. DELTA pushbutton, 2-fold, with labeling field (MUR, DND): One of the pushbuttons can be used to activate signal lamp DND (Do not disturb) outside and inside the room. The other pushbutton is used to activate the MUR function (Make up room). Device list Key Product no. and description Stock number 1 RDG100KN room thermostat S55770-T163 2 STA23 electrothermal actuator S55174-A101 3 DELTA hotel card switch with insert 5TG4 820 4 N 528/31 universal dimmer, main module, 1 x 300 W 5WG1 528-1AB31 5 N 502/02 combi switching actuator, 8 x 16 A, 8 inputs 5WG1 502-1AB02 6 N 523/02 blind actuator, 4 x 6 A 5WG1 523-1AB02 7 S 290 door/window contact 5WG1 290-7AB11 8 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 9 Rocker, with "Bell" symbol (SOS) 5TG6 207 Insert, universal switch 5TA2 156 10 Rocker, double, with labeling field (MUR, DND) 5TG6 212 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 Optional Key Product no. and description Stock number 11 RMB795B central control unit S55370-C162 C167 12 OZW772.x webserver OZW772.x 13 N 125/12 power supply 5WG1 125-1AB12 14 AP 257/32 weather station 5WG1 257-3AB32 15 N 151 IP viewer 5WG1 151-1AB01 16 UP 588 color touch panel 5WG1 588-2AB13 17 N 528/41 universal dimmer, extension, 1 x 300 W 5WG1 528-1AB41 27

3191S03 Application Manual Nr. 04 Variants Key Product no. and description Stock number 1a RDF600KN room thermostat S55770-T293 3a + UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 4a UP 525/13 universal dimmer, 1 x 250 W 5WG1 525-2AB13 5a UP 510/13 binary output, 2 x 10 A 5WG1 510-2AB13 6a UP 520/13 blind actuator, 1 x 6 A 5WG1 520-2AB13 8a 10a + UP 220/31 I/O pushbutton interface, 4 inputs/outputs 5WG1 220-2AB31 HVAC control B2 T Y1 M1 T (B1) 2-pipe fan coil unit with radiator Heating or cooling On/off, PWM or 3-position control of heating/cooling and radiator actuators Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Multifunctional inputs for keycard contact, external sensor, etc. T (B1) YR T N1 TAAC01 DG1 HQ The temperature in every room is acquired and controlled. Every room sends its heat/cooling energy request to the heating/refrigeration plant. These plants are controlled depending on the outside temperature and the heat/cooling energy requests received from the rooms. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered/raised to save heating/cooling energy. The room temperatures are also slightly lowered/raised during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. Blinds control When a room is not booked (or, if desired, when the guest is absent), a weather station outside the building protects up to 4 façades from extreme sunlight in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences. On sunny winter days, the weather station raises the blinds to let solar radiation make a natural heat contribution. When the guest is present, the blinds can be controlled via the pushbuttons and automatic operation is off. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 28

Application Manual Nr. 04 Function description Description of functions Individual room temperature control The room thermostat (RDG) acquires the temperature, controls it via the fan coil unit and calculates the demand for heat or cooling energy. The resulting signal is forwarded to the primary controller via the KNX bus. Time program and hotel booking system Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Presence-dependent heating control When the presence detector (hotel card switch) signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Economy level. Window contact If one or several windows of a room are opened, the operating mode changes automatically to Economy. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Presence-dependent lighting control When the room is no longer occupied, the lighting is automatically switched off after a delay time. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current state of windows and doors Current room temperatures Current room temperature setpoints Current operating modes If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. 29

Application Manual Nr. 04 Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms TAAC01 DG1 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ 2-pipe fan coil unit with radiator Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser RDG100KN RMB795B OZW772 GAMMA Application Sheet, Lighting L00001 N5 HQ GAMMA Application Sheet, Shading B00002 AP2 HQ Central and manual switching of lighting N 512/11 Shading of façades AP 257/32 30

Application Manual Nr. 05 Fan coil unit with radiator in the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating and cooling One control loop for the room and the bathroom Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Operation and display of HVAC Pushbuttons for "SOS", "Make up room", and "Do not disturb" Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Room setup 1. RDF600KN room thermostat: The RDF600KN acquires the room temperature and controls the fan coil unit and the radiator in the bathroom accordingly. The room operating mode can be selected and the temperature setpoints can be adjusted on the room thermostat. 2. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. 3. RMS705B switching and monitoring device: The RMS705B switches electric citcuits. All signals available at the inputs can be passed to the KNX bus. 4. S 290 door/window contact: The window contact causes the room operating mode to change to Economy when the window is open. It is connected directly to the RDF600KN. 5. DELTA pushbutton: The pushbutton is included in the electric circuit and switching directly the lighting, the blinds, etc. 6. DELTA pushbutton with "Bell" symbol (SOS): The pushbutton is used to trigger the alarm function. It is connected to the RMS705B. 31

Application Manual Nr. 05 7. DELTA pushbutton, 2-fold, with labeling field (MUR, DND): One of the pushbuttons can be used to activate signal lamp DND (Do not disturb) outside and inside the room. The other pushbutton is used to activate the MUR function (Make up room). The MUR pushbutton is connected to the RMS705B. 8. DELTA hotel card switch: When the card is inserted, the hotel card switch causes the room operating mode to change from Economy to Comfort and electric circuits are switched on. When the card is removed, the room operating mode returns to Economy. Electric circuits and lighting groups are switched off. Device list Key Product no. and description Stock number 1 RDF600KN room thermostat S55770-T293 2 STA23 electrothermal actuator S55174-A101 3 RMS705B switching and monitoring device, 6 x 4 A, 8 inputs S55370-C100 105 4 S 290 door/window contact 5WG1 290-7AB11 5 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 6 Rocker, with "Bell" symbol (SOS) 5TG6 207 Insert, universal switch 5TA2 156 7 Rocker, double, with labeling field (MUR, DND) 5TG6 212 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 8 DELTA hotel card switch with insert 5TG4 820 Optional Key Product no. and description Stock number 9 RMB795B central control unit S55370-C162 C167 10 OZW772.x webserver OZW772.x 11 UP 588 color touch panel 5WG1 588-2AB13 12 RMZ787 extension module, 4 x 4 A, 4 inputs RMZ787 13 N 125/12 power supply 5WG1 125-1AB12 14 N 151 IP viewer 5WG1 151-1AB01 Variants Key Product no. and description Stock number 1a RDG100KN room thermostat S55770-T163 1b RDG160KN room thermostat S55770-T297 32

3191S03 Application Manual Nr. 05 HVAC control B2 T Y1 M1 T (B1) 2-pipe fan coil unit with radiator Heating or cooling On/off, PWM or 3-position control of heating/cooling and radiator actuators Automatic or manual fan control, 1- or 3-speed Automatic or manual changeover of heating/cooling mode Multifunctional inputs for keycard contact, external sensor, etc. T (B1) YR T N1 TAAC01 DG1 HQ The temperature in every room is acquired and controlled. Every room sends its heat/cooling energy request to the heating/refrigeration plant. These plants are controlled depending on the outside temperature and the heat/cooling energy requests received from the rooms. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered/raised to save heating/cooling energy. The room temperatures are also slightly lowered/raised during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not used. Blinds control Manual control without bus connection. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 33

Application Manual Nr. 05 Function description Description of functions Individual room temperature control The room thermostat (RDF) acquires the temperature, controls it via the fan coil unit and calculates the demand for heat or cooling energy. The resulting signal is forwarded to the primary controller via the KNX bus. Presence-dependent lighting control When leaving the room, the electric circuits are interrupted, causing the lighting to be switched off after a delay time. When the hotel card is reinserted, the electric circuits are closed again. Time program and hotel booking system Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Presence-dependent heating control When the presence detector (hotel card switch) signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Economy level. Window contact If one or several windows of a room are opened, the operating mode changes automatically to Economy. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current state of windows and doors Current room temperatures Current room temperature setpoints Current operating modes If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms TAAC01 DG1 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ 2-pipe fan coil unit with radiator Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser RDG100KN RMB795B OZW772 34

Application Manual Nr. 06 Radiator in the room and the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating Two control loops for the room and the bathroom Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room", and "Do not disturb" Room setup 1. UP 227 room operator unit: The UP 227 acquires the room temperature and sends the temperature value, the setpoint shift and the operating mode to the AP 562/02 via the KNX bus. The UP 227 can also be used to control the lighting and the blinds. 2. AQR2532 room sensor with AQR2570 basic module: The AQR acquires and controls the room temperature in the bathroom via the radiator. 3. AP 562/02 valve actuator: The AP 562/02 drives the radiator valve. It receives the positioning signal from the UP 227 or the AQR controller. 4. AP 118 automation module box: The AP 118 has a socket for room automation modules type RS or RL. 5. RS 525/23 universal dimmer: The RS 525/23 features a relay contact to dim a lighting group up to 250 VA. 6. RL 521/23 blind actuator: The RL 521/23 features 2 relay contacts to control blinds. 7. RS 510/23 binary output, 2-fold: The RS 510/23 features 2 relay contacts to switch electric circuits. 8. S 290 door/window contact: The window contact causes the room operating mode to change to Protection when the window is open. 9. DELTA pushbutton: The pushbutton is connected to the UP 220 and is used to control the lighting. 35

Application Manual Nr. 06 10. DELTA pushbutton with "Bell" symbol (SOS): The pushbutton is connected to the UP 220 and is used to trigger the alarm function. 11. DELTA pushbutton, 2-fold, with labeling field (MUR, DND): One of the pushbuttons can be used to activate signal lamp DND (Do not disturb) outside and inside the room. The other pushbutton is used to activate the MUR function (Make up room). This signal is sent to the KNX bus via the UP 220 pushbutton interface. 12. DELTA hotel card switch: When the card is inserted, the hotel card switch causes the room operating mode to change from Precomfort to Comfort and electric circuits are switched on. When the card is removed, the room operating mode returns to Precomfort. Electric circuits and lighting groups are switched off. This signal is fed to the KNX bus via the UP 220 pushbutton interface. Device list Key Product no. and description Stock number 1 UP 227 room operator unit 5WG1 227-2AB11 2 AQR2570 room sensor, basic module S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 3 AP 562/02 valve actuator 5WG1 562-7AB02 4 AP 118 automation module box 5WG1 118-4AB01 5 RS 525/23 universal dimmer, 1 x 250 W 5WG1 525-2AB23 6 RL 521/23 blind actuator, 1 x 6 A 5WG1 521-4AB23 7 RS 510/23 binary output, 2 x 10 A 5WG1 510-2AB23 8 S 290 door/window contact 5WG1 290-7AB11 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 9 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 10 Rocker, with "Bell" symbol (SOS) 5TG6 207 Insert, universal switch 5TA2 156 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 11 Rocker, double, with labeling field (MUR, DND) 5TG6 212 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 12 DELTA hotel card switch with insert 5TG4 820 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 Optional Key Product no. and description Stock number 13 N 125/12 power supply 5WG1 125-1AB12 14 AP 257/32 weather station 5WG1 257-3AB32 15 N 151 IP viewer 5WG1 151-1AB01 16 UP 588 color touch panel 5WG1 588-2AB13 Variants Key Product no. and description Stock number 1a AQR2570 room sensor, basic module S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 1b UP 204 Contouch room controller 5WG1 204-2AB11 2a AQR2535 room sensor, temperature, humidity S55720-S141 4a AP 641 room control box 5WG1 641-3AB01 36

Application Manual Nr. 06 Room HVAC control Radiator heating Heating Setpoint shift On/of, PWM or 3-position control of radiator/floor heating system valves The temperature in every room is acquired and controlled. During nonoccupancy times (rooms not booked), the room temperatures are automatically lowered via the integrated hotel booking system. Open windows are always automatically detected and the temperatures of such rooms are lowered to save heating energy. The room temperatures are also slightly lowered during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. Blinds control When a room is not booked (or, if desired, when the guest is absent), a weather station outside the building protects up to 4 façades from extreme sunlight in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences. On sunny winter days, the weather station raises the blinds to let solar radiation make a natural heat contribution. When the guest is present, the blinds can be controlled via the pushbuttons and automatic operation is off. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 37

Application Manual Nr. 06 Function description Description of functions Individual room temperature control The room operator unit (UP 227) acquires and controls the room temperature and sends its positioning signal to the radiator s valve actuator. In the bathroom, the AQR acquires and controls the room temperature and sends its positioning signal to the radiator s valve actuator. Window contact If one or several windows of a room are opened, the operating mode changes automatically to Protection. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Time program and hotel booking system Time programs for up to 110 rooms or room groups can be defined on the touch panel (UP 588). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Presence-dependent heating control When the presence detector (hotel card switch) signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Precomfort level. Presence-dependent lighting control When the room is no longer occupied, the lighting is automatically switched off after a delay time. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current room temperatures Current room temperature setpoints Current operating modes Heating plant parameters (temperatures, fault state, etc.) Room occupancy State of blinds State of windows If required, the following parameters can be changed: The state of blinds (up/down) The room operating modes The room temperature setpoints Heating plant parameters (setpoints, operating modes) Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. GAMMA Application Sheet, Lighting L00001 N5 HQ GAMMA Application Sheet, Shading B00002 AP2 HQ Central and manual switching of lighting N 512/11 Shading of façades AP 257/32 38

Application Manual Nr. 07 Floor heating in the room and the bathroom, sun protection, presencedependent switching off of lighting and power supply Features Individual room temperature control, heating 2 control loops for the room and the bathroom Window contact central detection of open windows Detection of presence via hotel card switch Presence- and time-dependent control of HVAC, lighting, sun protection, and power supply to the room Central operation and display of HVAC, lighting, and sun protection Pushbuttons for "SOS", "Make up room", and "Do not disturb" Room setup 1. QMX3.P37 room operator unit: The QMX3.P37 acquires the room temperature and sends the temperature value, the setpoint shift and the operating mode to the N 605 via the KNX bus. The QMX3.P37 can also be used to control the lighting and the blinds. 2. QMX3.P70 room operator unit: The QMX3.P70 acquires the room temperature and sends the temperature value, the setpoint shift and the operating mode to the N 605 via the KNX bus. 3. N 605 thermal drive actuator: The N 605 features 6 inputs to connect pushbuttons and 6 outputs to control electrothermal actuators STA23. 4. AP 641 room control box: The AP 641 features 8 sockets for room automation modules type RS or RL. 5. RS 525/23 universal dimmer: The RS 525/23 features a relay contact to dim a lighting group up to 250 VA. 6. RL 521/23 blind actuator: The RL 521/23 features 2 relay contacts to control blinds. 7. RS 510/23 binary output, 2-fold: The RS 510/23 features 2 relay contacts to switch electric circuits. 8. S 290 door/window contact: The window contact causes the room operating mode to change to Protection when the window is open. 39

Application Manual Nr. 07 9. DELTA pushbutton: The pushbutton can be connected to the KNX interface of the AQR and is used to control the lighting. 10. DELTA pushbutton with "Bell" symbol (SOS): The pushbutton is used to trigger the alarm function. 11. DELTA pushbutton, 2-fold, with labeling field (MUR, DND): One of the pushbuttons can be used to activate signal lamp DND (Do not disturb) outside and inside the room. The other pushbutton is used to activate the MUR function (Make up room). This signal is fed to the KNX bus via the N 605. 12. DELTA hotel card switch: When the card is inserted, the hotel card switch causes the room operating mode to change from Precomfort to Comfort and electric circuits are switched on. When the card is removed, the room operating mode returns to Precomfort. Electric circuits and lighting groups are switched off. This signal is fed to the KNX bus via the N 605. 13. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. Device list Key Product no. and description Stock number 1 QMX3.P37 room operator unit, display and operation, temperature S55624-H108 2 QMX3.P70 room operator unit, temperature, humidity, CO 2 S55624-H104 3 N 605 thermal drive actuator 5WG1 605-1AB01 4 AP 641 room control box 5WG1 641-3AB01 5 RS 525/23 universal dimmer, 1 x 250 W 5WG1 525-2AB23 6 RL 521/23 blind actuator, 1 x 6 A 5WG1 521-4AB23 7 RS 510/23 binary output, 2 x 10 A 5WG1 510-2AB23 8 S 290 door/window contact 5WG1 290-7AB11 9 Rocker, neutral 5TG6 201 Insert, universal switch 5TA2 156 10 Rocker, with "Bell" symbol (SOS) 5TG6 207 Insert, universal switch 5TA2 156 UP 220/21 I/O pushbutton interface, 2 inputs/outputs 5WG1 220-2AB21 11 Rocker, double, with labeling field (MUR, DND) 5TG6 212 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 12 DELTA hotel card switch with insert 5TG4 820 13 STA23 electrothermal actuator S55174-A101 Optional Key Product no. and description Stock number 14 N 125/12 power supply 5WG1 125-1AB12 15 AP 257/32 weather station 5WG1 257-3AB32 16 N 151 IP viewer 5WG1 151-1AB01 17 UP 588 color touch panel 5WG1 588-2AB13 Variants Key Product no. and description Stock number 18a UP 220/31 I/O pushbutton interface, 4 inputs/outputs 5WG1 220-2AB31 2a QMX3.P30 room operator unit, temperature S55624-H103 40

Application Manual Nr. 07 Room HVAC control Radiator heating Heating Setpoint shift On/off, PWM or 3-position control of radiator/floor heating system valves Lighting control When the room is no longer occupied, the lighting is automatically switched off after a delay time. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 41

Application Manual Nr. 07 Function description Description of functions Individual room temperature control The room operator unit (P37) acquires and controls the room temperature and sends its positioning signal to the valve actuator. In the bathroom, the room sensor (P70) acquires and controls the temperature and sends its positioning signal to the valve actuator Window contact If one or several windows of a room are opened, the operating mode changes automatically to Protection. This means that heating or cooling energy is saved since the system does not try to compensate for energy losses. Time program and hotel booking system Time programs for up to 110 rooms or room groups can be defined on the touch panel (UP 588). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Protection, resulting in a lower temperature setpoint. After that, the setpoint is raised to the Economy level. Room automation can also communicate with the hotel s booking system. When the guest checks in, the room temperature is prematuraly raised to the Comfort level. During the periods of time the hotel is closed or in non-booked rooms, valuable heating energy is automatically saved by changing the operating mode to Economy. Presence-dependent heating control When the presence detector (hotel card switch) signals that the room is occupied, the room temperature is raised to the Comfort level. Then, it is lowered again to the Precomfort level. Presence-dependent lighting control When the room is no longer occupied, the lighting is automatically switched off after a delay time. Blinds control The weather station (AP257/32) with its built-in GPS receiver measures solar radiation and controls shading to protect the façade against sunlight. Up to 4 façades can be selected for automatic and individual control. In cold winter nights, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. When the room is occupied, automatic operation is deactivated. The blinds can then be controlled via the pushbuttons. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (IP viewer). The following parameters can be monitored: Current room temperatures Current room temperature setpoints Current operating modes Heating plant parameters (temperatures, fault state, etc.) Room occupancy State of blinds State of windows If required, the following parameters can be changed: The state of blinds (up/down) The room operating modes The room temperature setpoints Heating plant parameters (setpoints, operating modes) Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. GAMMA ApplicationSheet, Lighting L00001 N5 HQ GAMMA ApplicationSheet, Shading B00002 AP2 HQ Central and manual switching of lighting N 512/11 Shading of façades AP 257/32 42

Application Manual Nr. 08 Reception area room automation Air conditioning plant with indoor air quality and lighting control Features Room-supply air temperature control/co 2 control Automatic data exchange between room HVAC and primary plant VAV controller to optimize the ventilation system Remote control of individual rooms or groups of rooms Demand-compensated production of heat and cooling energy thanks to automatic data exchange with heating and refrigeration controller Constant light control Efficiency class A conforming to EN 15232 Room setup 1. AQR2532 room sensor with AQR2576 basic module: The AQR sends information about the room temperature and the indoor air quality to the ventilation controller, which controls the temperature and the proportion of fresh air in the supply air. 2. N 141/02 KNX/DALI gateway: The N141 transmits the KNX signal to the DALI bus to switch and dim the lighting. In the other direction, status information, such as error messages or operating times of lamps, is sent to the KNX bus. 3. UP258E21 presence detector with constant light control: The UP258E21 acquires room occupancy and brightness. This information is then fed to the room thermostat and the KNX/DALI gateway. 4. UP 588 color touch panel: The UP 588 is used to control and monitor HVAC, the lighting and the blinds. 43

Application Manual Nr. 08 Reception area room automation Device list Key Product no. and description Stock number 1 AQR2576 room sensor, basic module with CO 2 S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 2 N 141/02 KNX/DALI gateway 5WG1 141-1AB02 3 UP258E21 presence detector with constant light control 5WG1 258-2EB21 4 UP 588 color touch panel 5WG1 588-2AB13 Optional Key Product no. and description Stock number 5 N 125/12 power supply 5WG1 125-1AB12 6 N 151 IP viewer 5WG1 151-1AB01 5a OZW772.x webserver OZW772.x Variants Key Product no. and description Stock number 1a QMX3.P70 room operator unit, temperature, humidity, CO 2 S55624-H104 1b QMX3.P30 room operator unit, temperature S55624-H103 2a N 141/31 KNX/DALI gateway, twin 5WG1 141-1AB31 Ventilation control ECE01 U2B HQ Room-supply air temperature cascade control with plate heat recovery system, recirculated air damper, air heating coil and air cooling coil 7-day time switch with holiday/special day program Recirculated air operation (Precomfort) and outside air operation (Comfort) Control of supply and extract air fans Room- (extract air)-supply air temperature cascade control with minimum and maximum limitation of A supply air temperature Control of supply air temperature via the heat recovery system, the air heating coil valve and the air cooling coil valve in sequence Frost protection with frost protection sensor on the air side and controller-internal 2-phase frost protection function Monitoring of supply and extract air fans with differential pressure switches Monitoring of supply and extract air filters with differential pressure switches Sustained mode during nonoccupancy times Night cooling with outside air Summer/winter compensation, preheat function, activation of air heating coil pump at low outside temperatures Heat recovery system with Maximum Economy Changeover (MEU) Control of air heating coil pump, with pump kick Fault relay for all fault status messages The temperature is acquired in every room and controlled via the supply air. The ventilation controller controls the supply air temperature and the proportion of fresh air. The heating plant is controlled depending on the heat request from the ventilation controller plus the outside temperature. The refrigeration plant is controlled depending on the cooling energy request from the ventilation controller. Nonoccupancy times are reported by the presence detector or can be set in a time program. During these periods of time, the room temperatures are automatically lowered. 44

Application Manual Nr. 08 Reception area room automation Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. A brightness sensor incorporated in the presence detector helps when switching and dimming lights, ensuring that the room is always optimally illuminated, using as little as possible artificial light. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. Function description Description of functions Indoor air quality control The CO 2 sensor acquires the indoor air quality and forwards its value to the ventilation controller which controls the proportion of fresh air. Demand-dependent supply air temperature control The primary ventilation controller (RMU) controls the supply air temperature and the volumetric air flow depending on the room s demand for heat/cooling energy. Constant light control Constant light control maintains the room lighting at a constant brightness level by adding artificial light to daylight. Brightness is automatically and continuously adapted by dimming up/down the lighting groups. Offset adjustments allow the configuration of constant light control with only one presence detector. Manual switching and dimming is made possible via the pushbutton. In this case, lighting control is stopped and the brightness level in the room is maintained as long as presence is detected. Presence-dependent lighting control The presence detector (UP258E21) allows up to 4 lighting groups to be switched and controlled and detects presence within its range. If persons are detected, lighting is switched on at the required brightness level. When persons leave the room, the lighting is switched off again or dimmed. To extend the monitored range, a master-slave configuration can be implemented. Remote control and monitoring Using a webbrowser, the following parameters can be monitored via webserver (OZW): Current temperatures Current temperature setpoints Current operating modes Ventilation plant parameters (temperatures, errors, alarms) If required, the following parameters can be changed: The operating modes The temperature setpoints The time program Ventilation plant parameters (setpoints, operating modes) Using a webbrowser, all rooms can be controlled and monitored via webserver (IP viewer). The following parameters can be viewed/changed, if required: The state of lighting (on/off) Status information of lamps, such as error messages or the number of operating hours Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. 45

Application Manual Nr. 08 Reception area room automation Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Central Operating and Monitoring AECE01 U2B HQ Room-supply air temperature cascade control with plate heat recovery system, recirculated air damper, air heating coil and air cooling coil RMU720B Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ GAMMA Application Sheet, Lighting L00004 UP2 HQ Local plant operation and monitoring via local network with webbrowser Daylight- and presence-dependent lighting control (using DALI) OZW772 UP 258E21 46

Application Manual Nr. 09 Restaurant area room automation VAV plant with indoor air quality and DALI constant light control Features Fully integrated VAV application with temperature, CO 2, and volumetric air flow control Automatic data exchange between room HVAC and primary plant VAV controller to optimize the ventilation system Remote control of individual rooms or groups of rooms Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Constant light control Efficiency class A conforming to EN 15232 Room setup 1. RDG400KN room thermostat: The RDG400KN acquires the room temperature and calculates the request for heat/cooling energy sent to the heating/refrigeration and VAV controllers. It also controls valve actuator STA23 of the floor heating system. 2. QMX3.P70 room operator unit: The QMX3.P70 acquires the indoor air quality and sends its value to the ventilation controller which adjusts the amount of fresh air required. 3. GDB181.1E/KN VAV compact controller: The GDB.. controls the VAV dampers. The setpoints of the volumetric air flow are shifted depending on the amount of air demanded by the room thermostat. 4. N 141/02 KNX/DALI gateway: The N141 transmits the KNX signal to the DALI bus to switch and dim the lighting. In the other direction, status information, such as error messages or operating times of lamps, is sent to the KNX bus. 5. N 523/11 blind actuator: The N 523/02 features 8 channels to control up to 8 blind motors. 6. UP258E21 presence detector with constant light control: The UP258E21 acquires room occupancy and brightness. This information is then forwarded to the room thermostat and the KNX/DALI gateway. 7. UP 223/2 pushbutton, triple, neutral: The UP 223/2 is used to control the lighting and/or the blinds. 47

Application Manual Nr. 09 Restaurant area room automation 8. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. 9. UP 588 color touch panel: The UP 588 is used to control and monitor HVAC, the lighting and the blinds. Device list Key Product no. and description Stock number 1 RDG400KN room thermostat S55770-T165 2 QMX3.P70 room operator unit, temperature, humidity, CO 2 S55624-H104 3 GDB181.1E/KN VAV compact controller S55499-D134 4 N 141/02 KNX/DALI gateway 5WG1 141-1AB02 5 N 523/11 blind actuator, 8 x 6 A 5WG1 523-1AB11 6 UP258E21 presence detector with constant light control 5WG1 258-2EB21 7 UP 223/2 pushbutton, triple, neutral 5WG1 223-2DB12 UP 117/12 bus coupling unit (BTM) 5WG1 117-2AB12 8 UP 588 color touch panel 5WG1 588-2AB13 Optional Key Product no. and description Stock number 9 N 125/12 power supply 5WG1 125-1AB12 10 N 151 IP viewer 5WG1 151-1AB01 11 OZW772.x webserver OZW772.x 12 RMB795B central control unit S55370-C162 C167 13 AP 257/22 weather station 5WG1 257-3AB22 Variants Key Product no. and description Stock number 1a RDU341 room thermostat S55770-T106 3a GLB181.1E/KN VAV compact controller S55499-D135 4a N 141/31 KNX/DALI gateway twin 5WG1 141-1AB31 7a UP 223/3 pushbutton, triple, with status LED, neutral 5WG1 223-2DB13 7b Rocker, 2-fold, neutral 5TG6 205 UP 116/31 DELTA bus coupling unit, 2-fold 5WG1 116-2AB31 5a / 7c UP 520/03 blind actuator, 1 x 6 A 5WG1 520-2AB03 UP 221/2 pushbutton, 1-fold, neutral 5WG1 221-2DB12 48

3192S07 Application Manual Nr. 09 Restaurant area room automation Room HVAC control YV V M T (B1) T T (B1) N1 VAV plant Heating or cooling DC 0...10 V or 3-position control of VAV boxes or damper actuators Automatic or manual changeover of heating/cooling mode Automatic changeover of heating/cooling mode via supply air temperature (via KNX, only RDG400KN) Multifunctional inputs for keycard contact, external sensor, etc. TB0001 DG4 HQ The temperature is acquired in every room and controlled via the supply air and the floor heating system. The heat/cooling energy requests from all rooms are forwarded to the heating/refrigeration plant and the individual VAV controllers. The ventilation controller controls the supply air temperature and the amount of air demanded by the VAV controller. The heating plant is controlled depending on the heat request from the ventilation controller and the room thermostats plus the outside temperature. The refrigeration plant is controlled depending on the cooling energy request from the ventilation controller. Nonoccupancy times are detected by presence detectors and can be set for the night and every room in a time program. During these periods of time, the room temperatures are automatically lowered. Open windows are automatically detected and the temperature of these rooms is lowered to save heating energy. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. A brightness sensor incorporated in the presence detector helps when switching and dimming lights, thus ensuring that the room is always optimally illuminated, using as little as possible artificial light. 49

Application Manual Nr. 09 Restaurant area room automation Blinds control A weather station outside the building protects up to 8 façades from extreme solar radiation in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences and controls them at dusk and according to temperatures to save heating energy during winter nights. Finally, sun tracking control and shadow outline tracking allow a maximum of natural light to enter the rooms, offering optimum working conditions. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. 50

Application Manual Nr. 09 Restaurant area room automation Function description Description of functions Individual room temperature control The room thermostat (RDU/RDG) acquires the temperature and controls valve actuator STA23 of the floor heating system. When the room calls for heat/cooling energy, the room thermostat sends a heat request to the heating controller and/or a request for more warm/cold air to the VAV controller. indoor air quality control The CO 2 sensor acquires the indoor air quality and forwards its signal to the ventilation controller which controls the proportion of fresh air. Demand-dependent supply air temperature control The primary ventilation controller (RMU) controls the supply air temperature and the volumetric air flow depending on the request for heat/cooling energy from the room thermostat and the request for volumetric air flow from the VAV controller. The pressure setpoints of the ventilation system are shifted depending on the room s demand for supply air. Time program for every room Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Economy, resulting in a lower temperature setpoint. Hence, valuable heating energy can be saved during the night and on days of rest. After that, the setpoint is raised to the Precomfort level. Presence-dependent heating control When the presence detector signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Precomfort level. Constant light control Constant light control maintains room lighting at a constant brightness level by adding artificial light to daylight. Brightness is automatically and continuously adapted by dimming up/down the lighting groups. Offset adjustments allow the configuration of constant light control with only one presence detector. Manual switching and dimming is made possible via the pushbutton. In this case, lighting control is stopped and the brightness level in the room is maintained as long as presence is detected. Presence-dependent lighting control The presence detector (UP258E21) allows up to 4 lighting groups to be switched and controlled and detects presence within its range. If persons are detected, lighting is switched on at the required brightness level. When the persons leave the room, the lighting is switched off again. To extend the monitored range, a master-slave configuration can be implemented. Blinds control The weather station (AP257/22) with its built-in GPS receiver offers efficient control to protect the façade against sunlight. Automatic and individual control of up to 8 façades can be provided. Sun tracking control and shadow outline tracking are another 2 functions that ensure maximum usage of daylight and minimum glare in the room. Sun tracking control continuously adjusts the slats in a way that their position is always at a right angle in relation to the sun. Shadow outline tracking controls the position of the blinds such that the edge of the shadow always maintains the same distance to the window. This optimizes daylight usage, thus reducing the amount of energy required for the lighting. In cold winter nights and when nobody is present in the room, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained.. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current room temperatures Current room temperature setpoints Current operating modes Heating plant parameters (temperatures, errors, alarms) If required, the following parameters can be changed: 51

Application Manual Nr. 09 Restaurant area room automation The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Heating plant parameters (setpoints, operating modes) Using a webbrowser, all rooms can be controlled and monitored via webserver (IP viewer). The following parameters can be viewed/changed, if required: The state of lighting (on/off) Room occupancy Status information from lamps, such as error messages or number of operating hours State of blinds (raised/lowered) Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms TB0001 DG4 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ GAMMA Application Sheet, Lighting L00004 UP2 HQ GAMMA Application Sheet, Shading B00003 AP2 HQ VAV plant, single duct Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser Daylight- and presence-dependent lighting control (via DALI) Shading of façades including sun tracking control and shadow outline tracking RDG400KN RMB795B OZW772 UP 258E21 AP 257/22 52

Application Manual Nr. 10 Fitness room room automation VAV plant with indoor air quality and DALI constant light control Features Fully integrated VAV application with temperature, CO 2, and volumetric air flow control Automatic data exchange between room HVAC and primary plant VAV controller to optimize the ventilation system Remote control of individual rooms or groups of rooms Demand-compensated production of heat and cooling energy thanks to automatic data exchange with primary plant Constant light control Efficiency class A conforming to EN 15232 Room setup 1. RDG400KN room thermostat: The RDG400KN acquires the room temperature and calculates the request for heat/cooling energy sent to the heating/refrigeration and VAV controllers. It also controls valve actuator STA23 of the floor heating system. 2. AQR2532 room sensor with AQR2576 basic module: The AQR acquires the indoor air quality and sends its value to the ventilation controller, which controls the proportion of fresh air in the supply air. 3. GDB181.1E/KN VAV compact controller: The GDB.. controls the VAV dampers. Its setpoints of the volumetric air flow are shifted depending on the amount of air demanded by the room thermostat. 4. AP 641 room control box: The AP 641 features 8 sockets for room automation modules type RS or RL. 5. RS 525/23 universal dimmer: The RS 525/23 features a relay contact to dim a lighting group up to 250 VA. 6. RL 521/23 blind actuator: The RL 521/23 features 2 relay contacts to control blinds. 7. RS 510/23 binary output, 2-fold: The RS 510/23 features 2 relay contacts to switch electric circuits. 8. UP258E21 presence detector with constant light control: The UP258E21 acquires room occupancy and brightness. This information is fed to the room thermostat and the KNX/DALI gateway. 53

Application Manual Nr. 10 Fitness room room automation 9. DELTA pushbutton: The pushbutton with DELTA bus coupling unit is used to control the lighting and/or the blinds. 10. DELTA pushbutton: The pushbutton is connected to the KNX interface of the AQR and is used to control the lighting and/or the blinds. 11. STA23 electrothermal actuator: The STA23 adjusts the valve according to the positioning signal it receives from the controller. Device list Key Product no. and description Stock number 1 RDG400KN room thermostat S55770-T165 2 AQR2576 room sensor, basic module with CO 2 S55720-S203 206 AQR2532 room sensor, temperature S55720-S136 3 GDB181.1E/KN VAV compact controller S55499-D134 4 AP 641 room control box 5WG1 641-3AB01 5 RS 525/23 universal dimmer, 1 x 250 W 5WG1 525-2AB23 6 RL 521/23 blind actuator, 1 x 6 A 5WG1 521-4AB23 7 RS 510/23 binary output, 2 x 10 A 5WG1 510-2AB23 8 UP258E21 presence detector with constant light control 5WG1 258-2EB21 9 Rocker, 2-fold, neutral 5TG6 205 UP 116/31 DELTA bus coupling unit, 2-fold 5WG1 116-2AB31 10 Rocker, 2-fold, neutral 5TG6 205 Insert, pushbutton, 2-fold, 2 NO contacts 5TD2 111 11 STA23 electrothermal actuator S55174-A101 Optional Key Product no. and description Stock number 12 N 125/12 power supply 5WG1 125-1AB12 13 N 151 IP viewer 5WG1 151-1AB01 14 UP 588 color touch panel 5WG1 588-2AB13 15 RMB795B central control unit S55370-C162 C167 16 OZW772.x webserver OZW772.x 17 AP 257/22 weather station 5WG1 257-3AB22 Variants Key Product no. and description Stock number 1a RDU341 room thermostat S55770-T106 3a GLB181.1E/KN VAV controller S55499-D135 4a AP 118 automation module box 5WG1 118-4AB01 7a UP 223/2 pushbutton, triple, neutral 5WG1 223-2DB12 UP 117/12 bus coupling unit (BTM) 5WG1 117-2AB12 7b UP 223/2 pushbutton, triple, with status LED, neutral 5WG1 223-2DB13 54

3192S07 Application Manual Nr. 10 Fitness room room automation Room HVAC control YV V M T (B1) T T (B1) N1 VAV plant Heating or cooling DC 0...10 V or 3-position control of VAV boxes or damper actuators Automatic or manual changeover of heating/cooling mode Automatic changeover of heating/cooling mode via supply air temperature (via KNX, only RDG400KN) Multifunctional inputs for keycard contact, external sensor, etc. TB0001 DG4 HQ The temperature is acquired in every room and controlled via the supply air and the floor heating system. The heat/cooling energy requests from all rooms are forwarded to the heating/refrigeration plant and the individual VAV controllers. The ventilation controller controls the supply air temperature and the amount of air demanded by the VAV controller. The heating plant is controlled depending on the heat request from the ventilation controller and room thermostats plus the outside temperature. The refrigeration plant is controlled depending on the cooling energy request from the ventilation controller. Nonoccupancy times during the night can be set for every room in a time program. During these periods of time, the room temperatures are automatically lowered. Open windows are automatically detected and the temperature of these rooms is lowered to save heating energy. The room temperatures are also slightly lowered during the day, if the guest is not present. Lighting control Presence detectors (hotel card switches) help save energy by automatically switching the lighting off when the room is not occupied. A brightness sensor incorporated in the presence detector helps when switching and dimming lights, ensuring that the room is always optimally illuminated, using as little as possible artificial light. Blinds control 55

Application Manual Nr. 10 Fitness room room automation A weather station outside the building protects up to 8 façades from extreme solar radiation in the summer. This function helps to keep the rooms cool. The weather station also protects the blinds from damage caused by strong winds or other natural influences and controls them at dusk and according to temperatures to save heating energy during winter nights. Finally, sun tracking control and shadow outline tracking allow a maximum of natural light to enter the rooms, offering optimum working conditions. Remote control Integration of a webserver facilitates remote control and monitoring on a PC or smartphone via webbrowser. Function description Description of functions Individual room temperature control The room thermostat (RDU/RDG) acquires the temperature and controls valve actuator STA23 of the floor heating system. When the room calls for heat/cooling energy, the room thermostat sends a heat request to the heating controller and/or a request for more warm/cold air to the VAV controller. Indoor air quality control The CO 2 sensor acquires the indoor air quality and forwards its signal to the ventilation controller which controls the proportion of fresh air. Demand-dependent supply air temperature control The primary ventilation controller (RMU) controls the supply air temperature and the volumetric air flow depending on the request for heat/cooling energy from the room thermostat and the request for volumetric air flow from the VAV controller. The pressure setpoints of the ventilation system are shifted depending on the room s demand for supply air. Time program for every room Time programs for up to 10 rooms or room groups can be defined in the central control unit (RMB). A time program sets the periods of time the room is not used. During these time periods, the operating mode is set to Economy, resulting in a lower temperature setpoint. Hence, valuable heating energy can be saved during the night and on days of rest. After that, the setpoint is raised to the Precomfort level. Presence-dependent heating control When the presence detector signals room occupancy, the room temperature is raised to the Comfort level. Then, it is lowered again to the Precomfort level. Constant light control Constant light control maintains room lighting at a constant brightness level by adding artificial light to daylight. Brightness is automatically and continuously adapted by dimming up/down the lighting groups. Offset adjustments allow the configuration of constant light control with only one presence detector. Manual switching and dimming is made possible via the pushbutton. In this case, lighting control is stopped and the brightness level in the room is maintained as long as presence is detected. Presence-dependent lighting control The presence detector (UP258E21) allows up to 4 lighting groups to be switched and controlled and detects presence within its range. If persons are detected, the lighting is switched on at the required brightness level. When the persons leave the room, the lighting is switched off again. To extend the monitored range, a master-slave configuration can be implemented. Blinds control The weather station (AP257/22) with its built-in GPS receiver offers efficient control to protect the façade against sunlight. Automatic and individual control of up to 8 façades can be provided. Sun tracking control and shadow outline tracking are another 2 functions that ensure maximum usage of daylight and minimum glare in the room. Sun tracking control continuously adjusts the slats in a way that their position is always at a right angle in relation to the sun. Shadow outline tracking controls the position of the blinds such that the edge of the shadow always maintains the same distance to the window. This optimizes daylight usage, thus reducing the amount of energy required for the lighting. 56

Application Manual Nr. 10 Fitness room room automation In cold winter nights and when nobody is present in the room, the blinds are lowered to improve the building s thermal insulation. On sunny winter days, the blinds are raised, allowing sunlight to enter the room so that energy is gained. Protection of blinds The weather station acquires continuously the wind speed. If strong winds occur, the blinds are raised to a secure position. Remote control and monitoring Using a webbrowser, all rooms can be controlled and monitored via webserver (OZW). The following parameters can be monitored: Current room temperatures Current room temperature setpoints Current operating modes Heating plant parameters (temperatures, errors, alarms) If required, the following parameters can be changed: The room operating modes, individually or in groups The room temperature setpoints, individually or in groups The time program for every room or for groups of rooms Heating plant parameters (setpoints, operating modes) Using a webbrowser, all rooms can be controlled and monitored via webserver (IP viewer). The following parameters can be viewed/changed, if required: The state of lighting (on/off) Room occupancy The state of blinds (raised or lowered) Display of energy efficiency The OZW772 webserver is able to display the HVAC system s energy efficiency, which reminds the user if from the point of view of energy efficiency settings beyond the permitted limits were made. If nonefficient operating states occur, the user is notified via e-mail or smartphone app. The limit values can be set by the user. Secondary documents The Application Sheets listed below describe individual controller applications and contain detailed information. They can be downloaded from the Internet at www.siemens.com/hit Application no. Name of application Product no. Synco Application Sheet, Individual Rooms TB0001 DG4 HQ Synco Application Sheet, Centrally Managed Rooms QCA001 MB7 HQ Synco Application Sheet, Central Operating and Monitoring OWAL03 772 HQ GAMMA Application Sheet, Lighting L00004 UP2 HQ GAMMA Application Sheet, Shading B00003 AP2 HQ VAV plant, single duct Central control of room temperature control equipment Local plant operation and monitoring via local network with webbrowser Daylight- and presence-dependent lighting control (using DALI) Shading of façades including sun tracking control and shadow outline tracking RDG400KN RMB795B OZW772 UP 258E21 AP 257/22 57

Application Manual Nr. 11 Energy center primary control Heat, refrigeration and air handling Features Demand-compensated production of heat, cooling energy, and supply air Setpoint compensation depending on demand and outside temperature Together with room automation: Prerequisite to attain efficiency class A conforming to EN 15232 Room setup 1. RMH760B heating controller: The RMH760B controls the heating plant depending on the heat request from the ventilation plant and the rooms. 2. RMU720B refrigeration controller: The RMU720B controls the refrigeration plant depending on the cooling energy request from the ventilation plant and the rooms. 3. RMU720B ventilation controller: The RMU720B controls the primary ventilation plant depending on the heat/cooling energy and proportion of fresh air requests from the rooms. Device list Key Product no. and description Stock number 1 RMH760B heating controller RMH760B-x 2 RMU720B universal controller RMU720B-x 3 RMU720B universal controller RMU720B-x Optional Key Product no. and description Stock number 4 Plug-in type operator unit RMZ790 5 Extension module (4 UE, 2 AA, 2 DA) RMZ788 Variants Key Product no. and description Stock number 4a Detached operator unit with 3 m cable RMZ791 58