Using Disposable Garments in Arc Flash Exposures

Similar documents
Webinar November 12, 2014

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

DON T GET BURNED BY THE CONFUSION:

HOW TO CHOOSE THE RIGHT PROTECTION FOR FIRES, FLASH FIRES & ARC FLASHES

Flame Resistant Clothing: Statistics, Standards and Safety

The Basics Arc Flash Protection

Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE

DuPont NFPA Certified Attire

AN UNCOMPROMISING COMMITMENT TO SAFETY

AN UNCOMPROMISING COMMITMENT TO SAFETY

Combustible Dust with FR Clothing June Service Experience Trust Quality Flexibility

HI-VIS WORKWEAR & RAINWEAR. Medium. Large. X-Large. 3X-Large. 2X-Large. Small. 4X-Large

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

HexArmor. We re Safety, Redefined. 2 HexArmor ColdRush

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Care and Cleaning Recommendations for Mount Vernon FR Flame Resistant Fabrics

NFPA 70E Elevates Safety. with Heightened Risk Awareness

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

6/23/ National Electrical Contractors Association and Intec, Inc.

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

FLAME RESISTANT WORKWEAR (FRW) A Program Development Guideline

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

IAFF DIVISION OF OCCUPATIONAL HEALTH, SAFETY AND MEDICINE

PROTEK PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR PROTECTIVE WORKWEAR

TRAINING AND EQUIPMENT MANUAL 311 PERSONAL PROTECTIVE EQUIPMENT FIREFIGHTER PROTECTIVE CLOTHING CLEANING PROCEDURES EFFECTIVE: OCTOBER 2007

Committee on NFPA 2113

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

WELCOME. NOMEX Protective Apparel Solutions Seeheim, 6/7 th April DuPont s registered trademark. TM DuPont s trademark.

Nuclear Power Plant LSZH Cable Overview

Call MY.ARMOR or visit 3

UL Conference Atlanta May 21 22, 2014 Polyurethane Foam Association presentation

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Electrical Safety for Facility Managers and Building Owners

PROTECTING AGAINST ARC FLASH HAZARDS

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Soiled garments reflect less radiant heat. Materials saturated with hydrocarbons will absorb not deflect radiant heat from a fire.

For Salisbury by Honeywell

Electrical Safety Program.

Electrical Safety Compliance: NFPA 70E

Cost Savings. Waste disposal Occupational health Environmental impact Warehousing

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

OBERON USER GUIDE Arc Flash Suit Care & Use

SAFE WORK PROCEDURE. List the Hazards and risk controls as per risk assessment. assessment reference:

SALISBURY ASSESSMENT SOLUTIONS

Flame retardant. Protectivewear fabrics by Klopman International

COMBUSTIBLE DUST AN EXPLOSIVE ISSUE NFPA 654

MACHINERY & EQUIPMENT INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

Hazard Communication Self Inspection Checklist

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

MATERIAL SPECIFICATION FOR GEOTEXTILES

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

NFPA 70E Electrical Safety & Arc Flash Training

Arc Flash Protection Training - NFPA 70e Electrical Safety

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

Technical Committee on Flash Fire Protective Garments

Clean! Clean working by Qdel. Qdel laminating supplies Hamburgstraat 9 NL-7575 EG Oldenzaal T: E: I :

Y S L V i z L i t e 3 0 2

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

PREPARE, PROTECT & PREVENT: THE GUIDE TO PROPER PPE CLEANING

Indicators of Trouble. by John J. Lentini, CFI, F-ABC

Arc Fault Detection Devices (AFDDs) Protecting People and Property

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

NFPA 70E Electrical Safety in the Workplace

Guidance Note. Guidance Document on Best Practice for Fire Detector Testing/Test Equipment

Stillwater Area Community Services Center Inc.

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

Future Developments Personal Protection

Applying the 2012 NFPA 70E. Arc Flash Standard

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Bulwark Training. Combustible Dust: Understanding the Basics

TEST DATA. Classified by UL to NFPA 1994 Class 1, 2 and 2R (2018 Ed.) and NFPA 1992 (2018 Ed.)

Safe Schools: A Health and Safety Check

Diana H. Gulyas, President DuPont Performance Polymers Financials Safety and Protection Division Nomex Nomex Limitedwear

Buyer s Guide Warning Lights FAMA BUYER S GUIDE TC044. Warning Lights. Prepared by the FAMA Electrical Subcommittee

Safety Meeting Topic #37 NFPA 70E What is it?

Electrical Hazards and NFPA-70E: Protecting Your Employees

8/2017. Firefighter protective clothing ANACONDA. 3rd category of Personal Protective Clothing

CERTIFICATION BULLETIN

A NEW FORCE IN PROTECTIVE CLOTHING. Waxman

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

NFPA 70E Edition Update

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

GENERAL FIRE REQUIREMENTS SELF INSPECTION CHECKLIST

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

UNDERSTANDING THE CHANGES TO CALIFORNIA TB ON FLAME RETARDANCE OF RESILIENT FILLING MATERIALS USED IN UPHOLSTERED FURNITURE

Technical. Data Sheet. 3M Scotchlite Reflective Material 5535 Segmented Flame Resistant Trim. October Description. Retroreflective Performance

EMERGENCY PHONE: or (651) (24 hours) Ingredient C.A.S. No. % by Wt POLYPROPYLENE

Fire Safety. Version 1.0

Transcription:

An e-hazard.com White Paper 13113 Eastpoint Park Blvd. Suite E Louisville, KY 40223 502-716-7073 http://www.e-hazard.com Using Disposable Garments in Arc Flash Exposures Hugh Hoagland, Sr. Managing Partner, e-hazard.com President, ArcWear.com

Contents Arc-rated (AR) disposables? 2 Flame resistant (FR) disposables history 3 Melting makes the difference 3 Practical solutions 5 Summary 6 Arc-rated (AR) disposables? Many applications require disposable garments including chemical, biohazard, nuclear and just plain grease and dirt exposures. Some of these exposures are hazards in their own right (i.e. nuclear, biohazards and chemical hazards) others create new hazards (oil, grease combustible dust and other combustible contaminants) and nuisances (dirt, nonhazardous and non-combustible contaminants). Petrochemical workers and electricians exposed to an electric arc or flash fire hazard have something in common with a meth lab cleanup team. When they arrive on the job site, they may not know exactly what hazards they'll be exposed to, but they do know the potential for fire and chemical exposure exists. Ethanol, acids, oils, ammonia, and other chemicals may be the standard issue, but fire is always a possibility. The hazmat team, the electrician in a petrochemical plant, and a meatpacking company electrician all have something else in common: hydrocarbon loading potential on their clothing. When arcrated clothing has substantial hydrocarbon loading, ignition sources, such as potential flash fires or electric arcs, can make the garment less effective. In this type of situation, the worker must be cognizant of his or her surroundings and use personal protective equipment (PPE) made for those types of exposures. Under these circumstances, disposable FR garments are often the best solution. Let's take a quick look at the evolution of these garments for background.

Flame resistant (FR) disposables history Disposables have improved significantly these test methods is false. You can report the results of test methods but even that can be misleading. Table 1: Test Methods for Flame Resistance and their Limits Test Methods Full Scale (No pass/fail) Flame Test Heat Test Use Test FTMS 191A.5901/5903 (delisted) NFPA 701 (most will cite the 1989 version or earlier which didn t exclude clothing) ASTM D6413 ASTM F1959 ASTM F1930 from the first polyester spun-laced, throw-away garments that changed the chemical protection world just a decade ago. Those garments were resistant to many chemicals but were not adequate if a flash fire or electric arc ensued. They did and still do make many lowlevel chemical exposures less hazardous for workers at a reasonable cost. Newer coated and sealed seam garments on the chemical protection side have made even higher-level exposures, like chemical warfare, more survivable for first responders and soldiers. However, the flame-resistant side of the equation is still fraught with misunderstanding, especially when it comes to disposable garments. Many companies sell FR garments which meet no real applicable standard. They make claims based on the test methods in Table 1 but these claims are not substantiated. All the test methods in Table 1 are good methods but they must be understood and used in conjunction with a specification before the garment can truly be called PPE. None of the test methods in Table 1 have pass/fail criteria so claiming to meet Y N N Y N N One test method inappropriate alone. Clothing. Misused. Curtains, draperies, or other window treatments Misused. Y N N Clothing Y Y Y, Electric arc Y Y Y, flash fire Clothing Arc Rating. No melting and dripping. % body burn. No melting and dripping.. In 1994, the first arc- and flame-resistant raingear was developed. A difficult battle was fought to get folks out of FR -labeled garments that passed small-scale tests but would melt onto workers in a 1- to 3-second flash fire exposure or electric arc event. This campaign was successful. Now, another industry has a similar need. There are flame-resistant, chemical-resistant garments that have been flash fire and arc tested, but many garments on the market should not be used in a flame or arc exposure. How can you tell the difference? Melting makes the difference Any material that melts and drips in an electric arc or flash fire should not be used, even in low-risk potentials. The NFPA 70E standard requires that no melting materials be worn by a worker in any arc potential. Shouldn't this same interpretation be used in potential flame exposures? The most effective way to remedy this misunderstanding is to educate the market.

Cleaning up potentially hazardous materials is often part of the job. In electrical work, it could be oil containing small amounts of PCBs. This oil could also add hydrocarbon loading to the FR clothing. Cleaning up these materials requires a system of safety PPE that can be difficult to balance. It begs the question, Do I need FR, chemical protection, or both? With a garment to be worn over FR clothing and disposed of readily when soiled, this standard's requirements may create a garment with a lower value proposition. NFPA 2112 disposable garments make sense in some specific applications, particularly when the FR disposable can be worn longer or in lieu of FR clothing, such as an inexpensive coverall for a supervisor, engineer, or Table 2: Test Methods for Flame Resistance and their Limits Standard Specifications Flame Test Heat Test Full Scale Test Use ASTM F1506 Y Y NFPA 2112 Y Y CGSB 155.20 Y Y Market confusion about FR disposables and the meaning of some test methods is also a problem. Table 1 includes a list of the primary test method standards with an explanation of their proper uses. The first standard to address FR disposable garments was NFPA 2112, which added the allowance for FR disposable materials as non-woven materials. Some materials have been tested against this standard, but most specification writers are unaware of it. In addition, the standard also has some disadvantage to the end-user who wants a disposable garment. The disposable must meet a minimum body burn percentage and other tests make the non-woven disposable beneficial in some jobs but less disposable from a cost perspective. Y, ASTM F1959 Y, ASTM F1930 N, Does not include F1930 ASTM F2302 Y Y N Arc and flame clothing (tear strength portions have kept out disposables, committee voting 10/09) Flash Fire clothing. Allows disposables. Third party certified testing but some requirements make disposable more expensive than needed for some uses. Some cite only meeting the flame portion. Misused. For clothing NOT exposed to flame or arc. Some thick rainwear materials will pass but burn badly in arc or flash fire. visitor, or as outerwear in a higher potential threat. Most FR disposable garments in the past would have been tested with a vertical flame test to differentiate them from a non-fr garment. Researchers now know this is not sufficient. This and other small-scale tests alone are inadequate to predict flash fire or arc burn protection. Full-scale tests (such as ASTM F1959 Electric Arc or ASTM F1930 Flash Fire) are best for these evaluations. Because these full-scale tests entered the scene in the mid-1990s, the small-scale tests have been seen as less predictive of performance and usually are reserved for quality control only. A garment passing a vertical flame test may still be lifethreatening even in medial level flash

fires or electric arcs, especially if the not acceptable even if labeled FR. (Note: Available Materials Material Single Use Spun laced polyester, polyethylene, olefin, nylon, poly vinyl alcohol Kimberly-Clark Professional* KleenGuard* A65 Flame Resistant Apparel; DuPont Tempro, Lakeland Pyrolon Plus 2; Magid Econowear, Excel Extend FR (FR Sontara), Pyrolon XT FR Sontara More (durable FR Sontara with light weight nylon mesh on the surface). Pyrolon DTP, SoftGuard DTP (Heavier FR Sontara) Multi-use Limited Use Nomex (Spun laced Nomex) Multi-Threat Pyrolon CRFR (Coated FR Sontara) material is a melting material. There is no standard for low-cost FR disposable garments. While FR raingear manufacturers are changing their claims on flame resistance based on these fullscale tests and better knowledge, the FR disposable market has not kept up because there is no real specification using the available full-scale test methods. Melting materials such as polyethylene, olefin, polyester, nylon are Flame Resistant Arc or Flash Fire Rated N, Do not use in arc or flash fire potential Vertical flammability. Does not melt Y, Some have F1930, F1959 tested. No ratings. Y, Arc Rated ~14 cal/cm² Y, Meets NFPA 2112, Arc Rated ~6 cal/cm² Launderable Retail Price Comparison N $6+ N $6-15 N $29 5X $37.50 Y, F1930, F1959 N $27 TyChem ThermoPro Y, F1930 N No retail price found A small percentage of these types of materials may be in full-scale tested FR materials and can add value to their performance.) Practical solutions How do you know you're purchasing the right product for the potential hazards? Here are some factors to look for when selecting appropriate FR disposable garments.

Passes vertical flammability. Passes heat resistance. No melting and dripping in fullscale tests. Has some protective value from a full-scale test (ASTM F1930 or ASTM F1959). Must not melt and drip in your exposure potential. Lighter weight materials may not meet 50 percent body burn or have a high arc rating, but they should be evaluated by a fullscale test method. Other FR clothing should be worn underneath the disposable unless its full-scale rating is adequate for the task. A disposable that can be decontaminated or incinerated might be desirable in some applications. Most of these standards specifically prohibit all melting materials (i.e. polyester, nylon, acetate, polyethylene, polypropylene) from being worn as apparel for workers exposed to electric arc and flash fire respectively. Even when these materials are treated, they are not made truly non-contributory to injury when they can come in contact with skin (as under-layers or outer layers). Some instances exist where light weight inner layers have been used for wind breaks and some small amounts of these fibers have successfully been blended into true flame resistant clothing which meets flash fire standards or arc rating standards. Use ONLY approved specifications when looking for garments and be certain the garment has been tested to a reasonable method for arc-rating or flash fire rating if exposed to any of these hazards. In upcoming years, the industry will likely demand a disposable FR standard either from ASTM F1506, ISEA, or NFPA. Until that happens, examine the choices carefully. Look for full-scale data and evaluate the clothing system for the desired characteristics. Summary All the basic standards for arc flash and flash fire exposures prohibit melting materials: OSHA 29 CFR 1910.269 NFPA 70E IEEE NESC (National Electric Safety Code) ASTM F2733 flash fire protective rainwear F1891 arc flash rainwear NFPA 2112 flash fire clothing Hugh Hoagland does arc flash testing and electrical safety and arc flash training. He may be reached at hugh@ehazard.com or 502-314-7158. Looking Forward Future Specs ANSI/ISEA 101 Considering disposable FR option ASTM F1506 Voting Oct 09 to add NEW disposable FR category NFPA 2112 or CGSB 155.20 No current plans for disposable FR.