INSTALLATION & MAINTENANCE MANUAL

Similar documents
Heat Exchangers DKRCC.PF.000.G1.02 / 520H6410

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Instructions

Installation Instructions

Installation Instructions

SAAB 99 Series H Type Engine. Installation Guide Silicone Cooling System Hoses. Classic Silicone Hoses

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Installation and maintenance condensing unit manual

How To Make Lando Water Chillers? Leading the way of innovation. Here is the instruction to know more us how to

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Installation Instructions

Before using your machine, you must familiarize yourself with all of its components.

400KV Van de Graaff Generator Kit Builders Manual

300KV Van de Graaff Generator Kit Builders Manual

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers

Technical Bulletin TB-009

Heat Exchanger Block Replacement Instructions

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

If you have any questions, please feel free to contact me at (405) or via at

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Aluventa Design Guideline

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

A. P. E. CORP. EX-675 PNUEMATIC DESOLDER STATION

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

SENJU SPRINKLER CO., LTD.

VACUUM VALVES AND HOSES

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ZD-985 Desoldering Station

Pedimat Installation Instructions

Roofing Adhesive SARNACOL 2172 Spray

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

Increased Performance Higher System Efficiency Low Refrigerant Charge Compact Design

Installation, Operation, and Maintenance Information

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Air-Cooled Fluid Cooling Units (P/N E R2)

Instructions for Coating Fimbel Garage Door Panels

OPERATION AND MAINTNENCE MANUAL

Hydraulic Crimping Head, PN 69069

Flipside Handshower and Showerhead Installation and User Guide

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

pushing the tube into the rear of the water outlet housing with a slight twisting motion to evenly distribute the adhesive. After cleaning off any ext

Installation Manual PS-200 & PS-201

OWNER S MANUAL CAVS SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER

INSTALLATION INSTRUCTIONS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

WINDSHIELD REPAIR MANUAL SUPER CINCH

Model LF-310 Air Operated

POOL WINTERIZING INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS

Using the Lely Robot Sampler CanWest DHI Robot Manual

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

CONTENTS. 1 cooling technology white paper

Installation Manual PS-225 & PS-275

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

Glass Door Merchandiser Refrigerator and Freezer

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

TECHNICAL SERVICE GUIDE

TH01 Molding, Bodyside

Installation Instructions / Warranty

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Development and Application of Micro Channel Heat Exchanger for Heat Pump

Installation Instructions

Hydraulic Crimping Head, PN

R-124 MANUAL LOKRING W

Installation Instructions

Thermal Steel Care & Maintenance Guide

568X, 587X, 588X Series

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Qualification Procedures for making PE 3408 Extra High Molecular Weight Polyethylene Heat Fusion Joints

SERVICING INFORMATION

3.5 Cryosurface & Cryogenic Feed-through Specification

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

MX-DS1 Desoldering Gun for the MX-500P & MX-5200 Series

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Model H1011.8/H1011.8HPS Water Cooler

CIRRUS AIRPLANE MAINTENANCE MANUAL

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

Installation Instructions / Warranty

PANCRETE PAN IN A CAN

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

ONE PIECE TOILET LT3. Model: MPN: B0940 INSTALLATION INSTRUCTIONS. Version: 1.0

Welcome to the World of Aavid Heat Pipes

Installation Instructions / Warranty

Installation Instructions

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

METROPOLITAN Construction Standard No: UTILITIES DISTRICT

This chapter is devided into two sections:

Transcription:

MICOCHANNEL HEAT EXCHANGE INSTALLATION & MAINTENANCE MANUAL Version1.1 三花丹佛斯 ( 杭州 ) 微通道换热器有限公司 DANFOSS SANHUA (HANGZHOU) MICO CHANNEL HEAT EXCHANGE CO., LTD.

MAKING LIVES MOE COMFOTABLE THU INNOVATION Table of contents 1. Storage and Working Environment... 2 2. Handling - Handle with care!... 2 3. Bending Procedure... 3 4. Installation... 5 5. Leak epair Procedure... 7 6. Cleaning Procedure... 10 1

MAKING LIVES MOE COMFOTABLE THU INNOVATION Foreword This manual is a guide for installation and maintenance of Microchannel Heat Exchangers (MCHEs) supplied by Danfoss-Sanhua. We recommend that you read this manual carefully before commencing any work. MCHE is specially designed and manufactured for operating conditions that were specified by customer. Please consult Danfoss-Sanhua if want to change the operating conditions. Please notice that Danfoss-Sanhua will not be responsible or liable for any damage caused by failure to comply with the instructions in this manual and/or due to incorrect installation, operation and maintenance of MCHE. 1. Storage and Working Environment Microchannel heat exchanger should be stored indoor with a dry and clean environment. The storage temperature range is -30 C to 121 C (-22 F to 250 F). Metal chips, or dust of copper or steel can cause galvanic corrosion, so please keep the storage and installation areas clean and separate from machining or welding areas. Add use separate tools and/or keep tools clean. To minimize potential damage, we recommend that you keep MCHEs in the package until ready to install them on your unit. Improper storage and stack can cause premature corrosion or deformation and will reduce MCHE s life. Extra care should be taken! 2. Handling - Handle with care! Comparing with fin & tube coils, microchannel heat exchangers are relatively light. The fins are less easy to be bent and cut fingers. However the overall coil assembly is made of soft aluminum, so that it is surprisingly easy to be bent. The combination of these features makes it easy to handle and easy to be damaged. The good news is that there should be much less fin damage than traditional tube and fin coils because the microchannel tubes support and protect the fins. Keep in mind: The inlet and outlet tubes are designed only for connection and support their own weight. Unfortunately they locate where handles would be and often look like handles. Never lift a MCHE by the inlet and outlet tubes! 2

MAKING LIVES MOE COMFOTABLE THU INNOVATION Do not hit or drop MCHX on edges. Because they are made of soft aluminum, dropping, impacting, forcing, placing heavy objects on top of, or stepping on MCHEs will almost certainly deform them. Notice that if the coils end up bowed, it is possible to flatten them back out by laying them concave side down on a flat table and tapping them firmly with a large heavy flat plate (say 3-4 square feet of ½ plywood or plastic sheet with a couple of handles attached). This procedure works for bowed coils with flush fins, not for local fin protrusions. 3. Bending Procedure The same bending machines can be used for MCHE and tube & fin heat exchangers. We recommend that ship flat MCHEs for efficient packing and bend them at customer s plant. Bending radius The minimal bending radius required to achieve acceptable manufacturing yields is a function of the microchannel tube, fin, and alloy, as well as the bending equipment, fixturing, bending speed and bending length. Therefore during the development process customer should test bending the specific coil on the specific configuration to verify the design s manufacturability. In general, tighter radius, thicker tube and longer bend line are harder to bend. The below table is a rough guide to the possible smallest radius under the most favorable conditions. Use a more generous radius as possible. ecommended minimal bending radii (as determined by factory tests under favorable conditions) are shown below for different microchannel tubes and fins. Consult with Danfoss-Sanhua for the tubes not listed. Do not extrapolate or interpolate the values arbitrarily. 3

MAKING LIVES MOE COMFOTABLE THU INNOVATION Structural parameters Minimal ecommended Bending MC Material Tube Tube Fin mm in (Wmm*Hmm*Port #) (Hmm*Gage mm) 1G16 16*1.8*10 8.1*0.1 3102 90 3.5 1G20 20*2*12 8.1*0.1 3102 110 4.3 2G16 16*1.3*16 8.1*0.08 3102 90 3.5 2G20 20.6*1.3*20 8.1*0.08 3102 140 5.5 2G20 20.6*1.3*20 8.1*0.08 31104 170 6.7 2G25 25.4*1.3*26 8.1*0.08 3102 200 7.87 2G25 25.4*1.3*26 8.1*0.1 3102 170 6.7 2G25 25.4*1.3*26 8.1*0.08 31104 >220 >8.7 2G25 25.4*1.3*26 8.1*0.1 31104 190 7.5 3G16 16*1.3*16 11.4*0.09 3102 110 4.3 Pay attention to the following matters during bending emember that microchannel coils are made of soft aluminum that is surprisingly easy to be bent during handling. Before you bend, make sure the MCHE is flat, square and undamaged. Consider a sizing operation to ensure this. Make sure the coils are loaded into the bender in a way that keeps them flat square and undamaged. Keep the flat tubes perpendicular to the spindle while bending the coil. Clamp the coil during the bending, being careful not to crush it. Smaller bending speeds will often yield better results. Vertical spindle bending machines are often set up so that the microchannel coil ends up sliding along the table with all its weight supported by to header ends and/or the dead tube on the bottom. The dead tube in particular is supported only by fins and really not designed to hold the whole weight of a large coil, particularly when combined with a frictional load that wants to push the fins over. Therefore be careful to insure that at no point during the bending operations is one end of the coil cantilevered off the edge of the table, because this can cause the coil to droop so that the tubes are no longer perpendicular to the spindle, resulting in corkscrewing or reduced bend quality and/or consistency. Note also that in some benders, portions of the table drop down during bending, creating more opportunities for cantilevers. Per the above with vertical spindle benders, the quality, parallelism, and height (relative to the header ends) of the bottom dead tube can become important to control (depending on your coil holding fixtures). 4

MAKING LIVES MOE COMFOTABLE THU INNOVATION Bending multi-bend coils on a horizontal spindle bender can also cause cantilevered loads from the dead weight of the unsupported bent legs. For instance on a three bend coil, depending on fixturing, the load of the first 75% of the coil may be put back into the remaining coil leg, possibly causing poor bend quality and/or permanent deformation. This problem is more severe with MCHE s than with similar fin and tube coils. 4. Installation Pass Arrangement Carefully identify the locations of the inlet & outlet tubes. Microchannel condenser is often designed with multiple passages (parallel flow) that have fewer tubes in each successive pass. Confusedly connecting the inlet tube and the outlet tube of MCHE will result in excessively high refrigerant side pressure drop and poor heat exchanger performance. Coil Mounting Thermal expansion of aluminum is higher than most other materials. To avoid continuous thermally induced stress that will shorten its life, the microchannel heat exchanger must be mounted with at least some flexible brackets, so movement is possible not to apply unnecessary stress/tension onto the heat exchanger or its connections. 5

MAKING LIVES MOE COMFOTABLE THU INNOVATION It is preferable for the mounting brackets of the MCHE to only touch rubber or plastic grommets, bumpers, etc.. Direct contact with metal fasteners and/or frames can result in galvanic corrosion unless appropriate measures are taken to prevent it thru careful alloy selection, paints/coatings, etc.. Mounting bracket In order to fulfill customer-specific requirements, a variety of different mounting brackets are available, including: Inlet/outlet connections Inlet/outlet connections are designed to support themselves and for connections, not to act as handles, support mating tubes, resist thermal expansion, or be forced into position with mating tubes during assembly, etc.. In particular: Inlet/outlet connections should also be assembled & supported so the brazed joints are not exposed to stress/tension. To avoid damaging or collapsing the thin walled aluminum inlet/outlet tubes, mating tubes should be pre-bent/prepared so no bending/forcing is needed during installation. 6

MAKING LIVES MOE COMFOTABLE THU INNOVATION When copper and aluminum tubes are joined together, galvanic corrosion of the aluminum can result. Prevent this by protecting the joint with paint or a plastic heat shrink tube. (This will prevent moisture from entering the area and enabling corrosion by completing the galvanic circuit.) To protect the Cu-Al brazing joint and shrink tube from the heat of later brazing, the tube length after the joint on inlet/outlet pipes should be longer than 70mm. When brazing the coil into your system, additional protection can be obtained by dry nitrogen purging and/or wrapping the copper stub tube with a wet cloth. The aluminum inlet/outlet tube on the MCHE also needs to be at least 70mm long to protect the tube-header braze joint. The pipe length after the brazing joint should be longer than 70mm. 5. Leak epair Procedure The below instructions assume that you are familiar with general air conditioning repair procedures and have the appropriate equipment to evacuate the unit before the repair, then charge and performance test the unit afterward. Leak point detection Leak check per the A/C unit instructions or as follows. Use nitrogen or compressed dry air to pressurize the heat exchanger, and then detect the leak point by spraying the coil with a soap solution and looking for bubbles and/or foam. Alternatively, pressurize the MCHE with refrigerant or helium then detect the leak point by passing the appropriate sensor over the coil and mark the point. 7

MAKING LIVES MOE COMFOTABLE THU INNOVATION Microchannel tube leak repair by gluing If MCHE flat tube is leaking due to material/brazing failure or minor damage, it can be repaired quickly and easily by filling the hole with glue. Obtain the following materials and tools -2 component epoxy semi-viscose resin such as: High Performance Acrylate Structural Adhesive (WD-1001) - available in China JB WELD - available in US. Huntsman 2014-1 - available in China, US, Europe 3M Scotch-Weld Epoxy Adhesive (DP100 clear) - available in US. -Dispenser or injector (if not included with the resin) -Heat gun (if recommended to cure the resin) -Vacuum pump -Alcohol -Water -Knife -Brush Step 1: Clean the leak point emove the dirt from the surface around the leak point with brush and water, then wash off any residual oil with the alcohol. 8

MAKING LIVES MOE COMFOTABLE THU INNOVATION Step 2: Open up the leak point with a knife Open up the leak point to at least 1mm width by using the tip of the knife carefully. emove all aluminum fragments. Shape the cut to make it easy for epoxy resin to enter the microchannel like the below right picture shows. Step 3: Clean the surface around the leak point with alcohol. Step 4: Pull a vacuum Connect MCHE with vacuum pump and start evacuating the heat exchanger, preferably from both sides of the leak point. Step 5: Apply the epoxy (while unit is under vacuum) Prepare the high performance epoxy resin, and mix about 1~2cm 3 of resin per the resin instructions and put it into the injector (For some resins this is done automatically in a dispenser). Inject the resin carefully into the leak hole and make sure that a good amount of the resin is sucked into the opening when you are finished. Note: The vacuum pump should be able to pull your A/C unit s recommended vacuum and the cut area should be covered by epoxy (see the below right) 9

MAKING LIVES MOE COMFOTABLE THU INNOVATION Stop evacuating and verify that the vacuum holds. Blow hot air on the epoxy per the resin instructions if required and wait until the resin cures. Step 6: epeat original leak check the system per the A/C service instructions to verify that the leak has been plugged. 6. Cleaning Procedure elative to fin and tube heat exchangers, microchannel coils tend to accumulate more of the dirt on the surface and of the less dirt inside which can make them easier to clean. Step 1: emove surface debris emove surface dirt, leaves, fibers, etc. with a vacuum cleaner (preferably with a brush or other soft attachment rather than a metal tube), compressed air blown from the inside out, and/or a soft bristle (not wire!) brush. Do not impact or scrape the coil with the vacuum tube, air nozzle, etc.. Step 2: inse Do not use any chemicals (including those advertised as coil cleaners) to wash microchannel heat exchangers. They can cause corrosion. inse only. Hose the MCHE off gently, preferably from the inside out and top to bottom, running the water thru every fin passage until it comes out clean. Microchannels fins are stronger than traditional tube & fin coil fins but still need to be handled with care. Do not bang the hose into the coil. We recommend putting your thumb over the end of the hose rather than using a nozzle end because the resulting spray is gentler and the possibility for impact damage is less. Step 3: Optional blow dry Microchannel heat exchangers, because of their fin geometry, tend to retain water more than traditional fin & tube coils. Depending on the specific design and installation of your coil, it may be beneficial to blow or vacuum out the rinse water from your unit to speed drying and prevent pooling. 10

MAKING LIVES MOE COMFOTABLE THU INNOVATION Warning! It is possible to carefully clean a coil with a pressure washer, but it is also possible to totally destroy a coil with a pressure washer so we do not recommend their use. Warranty claims related to cleaning damage, especially from pressure washers or chemical attack, will not be honored. 11

MAKING LIVES MOE COMFOTABLE THU INNOVATION Danfoss Sanhua (Hangzhou) Micro Channel Heat Exchanger Co., Ltd. Add: No 289#, Street 12, Economic &Technological Development Area, Hangzhou, Zhejiang, China Post code: 310018 Tel: +86 571 86672399 Fax: +86 571 86672332 E-mail: sales@danfoss-sanhua.com Website: http://www.danfoss-sanhua.com 12