Infra Red Basin Tap IR120CP.1 & IR121CP.1

Similar documents
Intatherm Safe Touch Basin Tap IT1008CP

Infra Red Thermostatic Wall Mixer

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Enzo Concealed Shower Mixing Valve

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

Inta City Concealed Shower Mixing Valve CT80010CP

Plus Bath Shower Mixing Valve CP and PL30020CP

Kiko Bath Shower Mixing Valve KK90015CP

Telo Shower Mixing Valve TL10016CP

Inta City Shower Mixing Valve CT20010CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Deluge Shower Mixing Valve 10045CP

Puro Mini Dual Control Shower Mixer PU90010CP

Deluge Concealed Shower Mixing Valve DL40010CP

Mio Concealed Shower Mixing Valve MI40010CP

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Kiko Concealed Shower Mixing Valve KK80010CP

Eco IR Basin Tap. Installation and Maintenance Guide. A basin mounted tap with pre-programmed infra-red sensor; mains or battery supply.

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Pop-up Clicker Drain Installation and User Guide

Flipside Handshower and Showerhead Installation and User Guide

Oblo Basin and Bidet Monobloc Installation and User Guide

Singulier Spout Tube Basin Mixer Installation and User Guide

Antilia Wading Pool Glass Countertop Installation and User Guide

Installation & Operating Instructions

Installation and User Guide

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Beautifully Traditional

Automatic Infrared Tap TAPIFR. Instruction Manual

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Please do not hesitate to contact us with any enquiries.

DELIVERY & STORAGE INSTRUCTIONS PREPARING FOR INSTALLATION

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Installation Instructions Flute Tap Range

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Beautifully Traditional

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

HOT WASHER MODEL NO: KING150

IMPORTANT SAFETY INSTRUCTIONS

MemoirsStately3HoleBasin Mixer Installation and User Guide

Single Handle Lavatory Faucet

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

Single Lever Pull out Kitchen Tap

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Self-help Temperature Adjustment

ELECTRIC STOVE HEATER Models: FS2213B

Dehumidifier. Instruction Manual. Model DH-320/A

ascent Installation & maintenance instructions Customer/technical services Guarantee Mono basin filler with infrared sensor GUARANTEE REGISTRATION

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Beautifully Traditional

Thermostatic Bar Valves

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

Franke Specialist Range Pilatus Tap

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

METRO BASIN MONO MIXER CHR

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

Turbo Vac Pro 18V 2 in 1 Cordless Cleaner

Blueberry Kitchen Sink Tap

Advisory Bulletin. TB-106 Cleaning and Maintenance For Bobrick B-850, B-855, B-856 or B-858 Automatic Counter-Mounted Soap Dispensers

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

Cinnamon Kitchen Sink Tap

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Basin Tap. Time delay maximum 2 seconds

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

Thermostatic Concealed Shower Valve

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Autofill counter top water boiler

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

Installation Instructions and User Guide. Heritage Fixed Riser Kit. Models Covered: STC03 (Chrome) STA03 (Gold)

Portable Air Conditioner

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

VADA - Rain2Main Automatic Rainwater Controller

ORIGINAL INSTRUCTIONS

HANDLING INSTRUCTIONS for DISPENSA VVS-x

Beautifully Traditional

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

identity installation & maintenance instructions customer/technical services guarantee

SUPER CLEAN FILTER PUMP USER S MANUAL 29P414XX/29P415XX/29P416XX/29P417XX

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

MLT100 Mirror Waterfall Fountain Bronze

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Transcription:

Infra Red Basin Tap IR120CP.1 & IR121CP.1 Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility should it be found that in any respect the information is inaccurate or incomplete or becomes so as a result of further developments or otherwise. Intatec Ltd. 2014 Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF Tel: 01889 272 180 Fax: 01889 272 181 email: sales@intatec.co.uk web: www.intatec.co.uk

Introduction This installation guide has been produced for the IR120CP.1 & IR121CP.1 infra red basin taps. These instructions cover the installation, operation and maintenance. Please read the enclosed instructions before commencing the installation of this product, please note; We recommend that the installation of any Inta product is carried out by an approved installer. Products Infra red basin mounted tap with battery box IR120CP.1 Infra red basin mounted tap with electronic transformer IR121CP.1 Check Contents Before commencing remove all components from packaging and check each component with the contents list. Ensure all parts are present, before discarding any packaging. If any parts are missing, do not attempt to install your Inta electronic tap until the missing parts have been obtained Item Components 1 Tap with infra red sensor 2 Fixing kit 3 Copper pipe 4 Gasket 5 Solenoid valve 6 Filter gasket 7 Battery holder or transformer 8 2 screws & 2 wall plugs 3 1 10 9 4 8 5 2 7 6 Water supply Intatec Ltd 2014 1

Check Contents Alkaline 4 x 1,5V (AA) Transformer 230 V 10 Technical Data To electricity supply Power specification: 6V low voltage system Power source - IR120CP.1: 4 x 1.5V AA batteries IR121CP.1: 230V transformer Operating water pressure: 1.0 to 8.0 bar (14.5 to 116 psi) With water pressure in excess of 8 bar use with a pressure reducing valve. Max. recommended water pressure: 5.0 bar Hot water temperature: 5 to 65 C maximum - To limit the outlet temperature to 41 C max. we recommend using theintamix Thermostatic Mixing Valve code 40015CP. Self opening after last water flow: Every 24 hours Intatec Ltd 2014 2

Pre-installation Information Warning Do not install the tap facing a mirror or any other electronic system operated by an infra red sensor. This tap is also vulnerable to stray sensor readings from users wearing high visibility or other reflective clothing. To prevent reflection problems, it is recommended to keep a minimum distance of 1.5m between the tap and other objects. Preparation for installation Flush the water supply pipes thoroughly prior to installation. Do not allow debris, PTFE tape or any metal particles to enter the tap. Do not expose to temperatures below 5 C, for example during winter. If the tap will be exposed to freezing conditions the tap and system should be drained. Important: All plumbing is to be installed in accordance with applicable codes and regulations. Installation 1. A service valve should be installed in the water supply pipe to the valve should maintenance be required in the future. 2. Turn off the water supply using the service valve (not supplied). 3. Install the tap (1) to the basin using fixing kit (2). 4. Connect the copper pipe (3) to the tap and the other end to the solenoid valve (5) using the gasket (4). Ensure the flow through the solenoid valve will be in the correct direction with flow to the tap, as marked on the solenoid valve. 5. Connect the solenoid to the water supply using the filter water (6). Failure to fit the filter washer can damage the solenoid valve and invalidate the product warrantee. 6. Fix the power supply unit to the wall using the wall plugs and screws provided. 7. Connect the signal cable to the tap by assembling connector (9). 8. Turn on the water supply and check all joints for leakage. 9. Isolate via the service ball valve and tighten or remake joints if leakage occurs. Intatec Ltd 2014 3

Connecting the power supply 1. Check that the sensor window is clean and that there are no obstructions in front of the window. 2. Insert batteries into the battery box or connect the transformer to electricity supply. 3. Connect the power supply to the tap by assembling connector (10). 4. The LED under the sensor window will start flashing, when it stops the tap is ready for use. IMPORTANT: This product must be installed by a suitably qualified and competent person carrying the relevant current IEE electrical qualification. Sensor Range The sensing range of the tap is preset and should not require adjustment. If however the range needs to adjusted it can be, using the following procedure; Unplug the power connector (10) or in the case of the transformer turn off the power supply. Wait for 30 seconds before re-connecting or turning on the power supply. When the red LED blinks (if it switches off, it is necessary to unplug the power connector or turn off the power supply and repeat the operation), put one hand immediately in front of the sensor (at a maximum distance of 5cm). When the red LED lights up permanently, move your hand to the desired sensor distance. Wait for the LED to turn off before moving your hand; at this point the new distance is stored. The new setting will be stored in case of battery replacement or failure of the electrical supply. Prevention of Flooding To prevent flooding the wash room following an act of vandalism or carelessness - an object left in front of the sensor or dirty sensor, the tap has a safety device that shuts off the water flow after approximately 1 minute. Once the object has been removed or the sensor cleaned, the tap will start working again. The model with the transformer unit has an automatic shut off which turns off the water supply until the power supply is re-established. Intatec Ltd 2014 4

Aftercare Inta taps have a high quality finish and should be treated with care. An occasional wipe with a mild washing-up liquid on a soft damp cloth followed by a thorough rinsing is all that is required. Do not use an abrasive or chemical household cleaner as this may cause damage. Cleaning the sensor - the darkened window which protects the sensor must always be clean in order for the tap to operate correctly; do not use abrasive material to avoid damaging the plastic surface. Cleaning the water supply filter (6) - water can contain impurities which could damage the solenoid valve. For this reason the inlet to solenoid valve has a gasket with an integral filter which must be kept clean in order to ensure a suitable water flow. CAUTION: turn off the water supply using the service valve before unscrewing the joint to remove the filter gasket for cleaning. Battery Replacement - IR120CP.1 When the batteries are exhausted, the LED blinks continuously and the solenoid valve stops in the closed position, replace the batteries and recycle the used batteries correctly. Warranty Limited Warranty This product is covered by a limited warranty for one year from the date of purchase. During this period Intatec Ltd undertakes, at its option, to repair or replace any faults caused by defective material or manufacturing faults that may arise (see Intatec Warranty). This guarantee does not cover faults or damage caused by incorrect installation and/or maintenance, wear and tear, battery or water composition (eg hard water), this includes but is not limited to the following: Incorrect installation, inversion of supply pipes. Pressure or temperatures exceeding the recommended limits. Improper use, tampering, bad or lapsed maintenance. Foreign bodies, dirt or scale introduced by the water supply. Intatec Ltd 2014 5

Trouble Shooting Problem Cause Solution No water flow from tap Check service valve is closed Exhausted battery - the LED blinks Electrical problems Dirty sensor - with vandalism protection Filter is dirty Blocked solenoid valve Open service valve Replace battery Check the voltage - where needed Disconnect and reconnected the battery Check the connector of the power cable Check the cable for damage Damaged sensor - assistance required Clean the sensor window Close the service valve and clean the filter Assistance required The water flows for 1 minute without an object in front of the sensor. Water flows for more than one minute Dirty sensor Light reflections on the sensor Electrical problems Blocked solenoid valve or damaged senor Clean the sensor window Remove the reflection source - adjust the detection distance Disconnect and reconnect the battery Assistance required Self opening and closing of the tap without user s presence Light reflection on sensor Remove the reflection source - adjust the detection distance The water flows without the tap being activated Self opening function every 24 hours from last operation Eliminates the risk of stagnant water Please Leave this Manual for the User Intatec Ltd 2014 6

To active your product warranty please visit www.intatec.co.uk and click on Product Registration Intatec Ltd Airfield Industrial Estate Hixon Staffordshire ST18 0PF E & O.E Intatec Ltd 2014 Tel: 01889 272 180 Fax: 01889 272 181 email: sales@intatec.co.uk web: www.intatec.co.uk 13-11-14