CONDOR. Supply air ceiling QUICK FACTS

Similar documents
CHILLED BEAM CASSETTE IQ STAR LYRA

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

iq Star LYRA II chilled beam cassette

Primo Hotel. General. Indoor climate units for hotel rooms

HOTEL CHILLED BEAM IQ STAR SILENCIA

Ceiling diffusers. Type DLQL

LØV-R. Svalbard-H. Chilled beam for corner installation between wall and ceiling

Units for suspended ceilings

PARASOL EX. Suspended comfort modules QUICK FACTS

iq Star LYRA II chilled beam cassette

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

Units for suspended cei lings

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

Ceiling swirl diffusers

Ceiling air diffuser INDULTHERM INDULTHERM-e

ADRIATIC VF. Active chilled beam with cooling, heating and ventilation QUICK FACTS

Ceiling swirl diffusers

Type TDF-SilentAIR WITH VERY LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH FIXED AIR CONTROL BLADES

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Orion-Opus LØV-R with Sirius

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

Air distribution systems. Opticlean OC-Q...

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

PARAGONTM Comfort module for hotel rooms and hospital wards

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

Orion-PTV LØV-R with Sirius

Orion-LØV LØV-R with Sirius

KLIMA Active Chilled Beams

Orion-LØV LØV-R with Sirius

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

TTC. TTC Active supply air diffuser. Product description. Introduction SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Simplicity

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Ceiling air diffuser INDULTHERM INDULTHERM-e

TTC. TTC Active supply air diffuser. Product description SUPPLY AIR DIFFUSER - ACTIVE [CEILING MOUNTED] Introduction. Simplicity

ROOFMASTER STEF-HT ROOF FAN

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

KOMFORT EC DB Suspended heat recovery air handling units

HYBRID PLUS2 AIRCOOL VENTILATORS

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Halton Rex 600 Basic R6B - Active chilled beam

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

ROOFTM. roof products. Roof products for a complete ventilation system HOME VENTILATION

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

HYBRID PLUS2 AIRCOOL VENTILATORS

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

QZB "Standard" comfort fan coil

COMPACT Air & Heat. Contents

Recessed. Air Curtain. Fig 1. Recessed air curtain

Fan Coil Unit CULTRA

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

TURBO HOODS. Product Brochure

CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER

Polaris-I-60. active chilled beam. the future of space conditioning

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

System architecture. Air treatment Index

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

DV-PP-L-125 DV-PP-L-150. Noise level [db] Capacity [m3/h]

PARAGON. Compact comfort module. Key figures

Passive chilled beams

Cooling Strip Model SPB

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Brand : CCC. AIR DIFFUSION EQUIPMENT EGG CRATE GRILLES Series : CCC-ECRG

Ecophon Solo Baffle Wave

UV-TURBO HOODS. Product Brochure

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Technology for life. Unit heater LH

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

GLEC exhaust FAN. Air Comfort. Air movement. Duct & Box Fans

CONTENT: VEX308 Decentralised ventilation VEX308

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Intumescent Fire Dampers

Bevent Rasch. FIDs. - Fire /05/18

Fan heater Panther Powerful fan heater for large premises

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Chilled ceiling panel INDUCOOL-Compact

Halton Rex for Vario R6O - Variable air volume chilled beam

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Performance Rating of Active Chilled Beams

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

VENTILATION SYSTEM COMPONENTS. Product Overview

Units for suspended ceilings Type DID632

ADAPT Parasol EX. Energy-saving, suspended comfort module QUICK FACTS

Active Chilled Beams

TopVent Design Handbook

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Chilled Beam/Induction Unit

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Transcription:

Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O W - S O U N D L E V E L CONDOR 0 db(a) Size l/s m /h 00-600-50 0 50 800-600-5 00 70 00-600-5 5 88 000-600-00x50 0 6 00-00-5 60 96 800-00-600x00 60 96 00-00-600x00 90 76 000-00-800x50 570 05

Technical description Design The supply air ceiling consists of a number of diffuser modules, equipped with discs, which are installed in a common backing box. The air diffuser modules are also equipped with the VariZon air distribution system to distribute air uniformly. Materials and surface treatment The supply air ceiling is manufactured in galvanised sheet steel. The nozzles and distribution plates are made of plastic (PP Polypropylene). The entire unit is painted with our pure white standard paint, RAL 900/NCS S 0500-N. The unit is also available in other standard colours: Dusty grey 707, white aluminium RAL 9006, jet black RAL 9005, grey aluminium RAL 9007 and white RAL 900. Special version In addition to the standard sizes, this unit can be supplied in special dimensions and with different numbers of discs, etc. CONDOR is also available in galvanized finish. Please contact your nearest sales office for information. Maintenance Clean when necessary with lukewarm water and detergent or vacuum-clean with a brush nozzle. Access can be gained to the duct system without tools. The diffuser section is removed in the same way as a normal cassette ceiling. Environment Declaration of construction materials is available at www. swegon.com. Accessories Commissioning damper with measuring unit. Planning The unit can be installed freely suspended or integrated in a suspended ceiling. It is well-suited for environments such as institutional kitchens, clean rooms, laboratories and environments that require large air volumes discharged from a small face surface. The recommended maximum under-temperature is 5 C. The recommended minimum installation height above the floor is.7 m. Take into consideration that the air diffuser does not fit directly into suspended ceiling systems, as the dimensions of the air diffuser are 600x600, 600x00, 00x00 etc. Installation The backing box has a number of M8 pop nuts on top and a number of attachment eyes along the sides for suspended installation. The backing box can also be bolted directly to the building structure from inside the box. The diffuser panels are inserted into the backing box at an angle, with the VariZon distribution plates facing the airflow, then laid on the grid. See Figure. The profiled sections of the modular ceiling system can be fastened directly to the edges of the backing box. Use blind rivets as fasteners. Commissioning The air flow is commissioned with an adjustable measurement unit which is placed in the connecting duct. Use for example. CRM, or SIRI Figure. Installation. Swegon reserves the right to alter specifications. 079

Sizing The sound level db(a) applies to rooms of 0 m equivalent sound absorption area. The recommended maximum under-temperature with a standard discs installation is 5 C. To calculate the width of the airstream, air velocities in the occupied zone or sound levels in rooms with other dimensions, contact the nearest sales office for information. For calculating the width of the air stream, air velocities in the occupied zone or sound levels in rooms with other dimensions, please refer to our web calculation softwares available for download at www.swegon. com. Sound data CONDOR Supply air Sound power level L w (db) (0 m Sabine) Table K OK CONDOR Mid-frequency (octave band) Hz Size (mm) 6 5 50 500 000 000 000 8000 00-600-50 5 9 7 - -6-9 - 800-600-5 6 0 7-5 -7-8 - 00-600-5 5 8-5 -6-7 - 000-600-00x50 7-6 -7-0 -5 00-00-5 6 9 8 - -5-6 - 800-00-600x00 5 8-6 -5-6 -0 00-00-600x00 6 9 8-6 -7 - -9 000-00-800x50 9-7 -0 - -7 Tolerance ± Sound attenuation DL (db) (0 m Sabine) Table DL CONDOR Mid-frequency (octave band) Hz Size (mm) 6 5 50 500 000 000 000 8000 00-600-50 5 0 5 5 800-600-5 9 0 00-600-5 9 0 000-600-00x50 0 6 00-00-5 9 0 800-00-600x00 0 6 00-00-600x00 8 000-00-800x50 6 0 0 0 0 0 Tolerance ± 079 Swegon reserves the right to alter specifications.

Engineering graphs CONDOR Supply air Airflow Pressure drop Sound level Affected area The graphs must not be used for commissioning. The db(a) values are for rooms with normal acoustic absorption of db. The db(c) value is normally 6-9 db s higher than the db(a) value. For more accurate calculations, see the calculation template in the chapter on Acoustics in the Technical Information section of this catalogue. CONDOR Single CONDOR Double p t Pa 00 50 0 0 0 0 5 0 5 0 0 db(a) 5 p t Pa 50 0 0 0 0 5 0 5 0 0 db(a) 5 00 00 00 00 500 l/s 00 00 00 00 500 l/s 000 00 00 500 000 000 m /h 00 500 000 000 m /h 5 l 0, m 5 l 0, m Size designation:. 00-600-50. 800-600-5. 00-600-5. 000-600-00x50 Size designation:. 00-00-5. 800-00-600x00. 00-00-600x00. 000-00-800x50 Swegon reserves the right to alter specifications. 079

Dimensions and weights Size (mm) Weight (kg) 00-600-50 7,0 800-600-5,0 00-600-5 5,0 000-600-00x50 68,0 00-00-5 6,0 800-00-600x00 69,0 00-00-600x00 9,0 000-00-800x50 5,0 9 Figure. CONDOR, dimensions. CL = Centerline. 079 Swegon reserves the right to alter specifications. 5

Order key Product Supply air ceiling system CONDOR a -aaaa -bbb -ccc Version: Nom. length (mm): 00, 800, 00, 000 Nom. width (mm): 600, 00 Nom. connection diam. (mm): Ø 50, 5 Rectangular dimensions (mm): 00x50, 600x00, 600x00, 800x50 Standard range: 00-600-50 800-600-5 00-600-5 000-600-00x50 00-00-5 800-00-600x00 00-00-600x00 000-00-800x50 Specification example Swegon s supply air ceiling system, type CONDOR, with the following functions: Diffuser modules, equipped with nozzles 00% flexible spread pattern Individually adjustable nozzles (55 mm) made from recyclable PP (Polypropylene) plastic VariZon air distribution system Can be cleaned Powder coated in white Backing box that can be cleaned Size: CONDORa - aaaa - bbb - ccc xx items 6 Swegon reserves the right to alter specifications. 079