Supply air ceiling QUICK FACTS 00% flexible spread pattern High induction rate Can be cleaned Diffuser modules 595 x 595 mm Available in alternative colours VariZon air distribution system A I R F L O W - S O U N D L E V E L CONDOR 0 db(a) Size l/s m /h 00-600-50 0 50 800-600-5 00 70 00-600-5 5 88 000-600-00x50 0 6 00-00-5 60 96 800-00-600x00 60 96 00-00-600x00 90 76 000-00-800x50 570 05
Technical description Design The supply air ceiling consists of a number of diffuser modules, equipped with discs, which are installed in a common backing box. The air diffuser modules are also equipped with the VariZon air distribution system to distribute air uniformly. Materials and surface treatment The supply air ceiling is manufactured in galvanised sheet steel. The nozzles and distribution plates are made of plastic (PP Polypropylene). The entire unit is painted with our pure white standard paint, RAL 900/NCS S 0500-N. The unit is also available in other standard colours: Dusty grey 707, white aluminium RAL 9006, jet black RAL 9005, grey aluminium RAL 9007 and white RAL 900. Special version In addition to the standard sizes, this unit can be supplied in special dimensions and with different numbers of discs, etc. CONDOR is also available in galvanized finish. Please contact your nearest sales office for information. Maintenance Clean when necessary with lukewarm water and detergent or vacuum-clean with a brush nozzle. Access can be gained to the duct system without tools. The diffuser section is removed in the same way as a normal cassette ceiling. Environment Declaration of construction materials is available at www. swegon.com. Accessories Commissioning damper with measuring unit. Planning The unit can be installed freely suspended or integrated in a suspended ceiling. It is well-suited for environments such as institutional kitchens, clean rooms, laboratories and environments that require large air volumes discharged from a small face surface. The recommended maximum under-temperature is 5 C. The recommended minimum installation height above the floor is.7 m. Take into consideration that the air diffuser does not fit directly into suspended ceiling systems, as the dimensions of the air diffuser are 600x600, 600x00, 00x00 etc. Installation The backing box has a number of M8 pop nuts on top and a number of attachment eyes along the sides for suspended installation. The backing box can also be bolted directly to the building structure from inside the box. The diffuser panels are inserted into the backing box at an angle, with the VariZon distribution plates facing the airflow, then laid on the grid. See Figure. The profiled sections of the modular ceiling system can be fastened directly to the edges of the backing box. Use blind rivets as fasteners. Commissioning The air flow is commissioned with an adjustable measurement unit which is placed in the connecting duct. Use for example. CRM, or SIRI Figure. Installation. Swegon reserves the right to alter specifications. 079
Sizing The sound level db(a) applies to rooms of 0 m equivalent sound absorption area. The recommended maximum under-temperature with a standard discs installation is 5 C. To calculate the width of the airstream, air velocities in the occupied zone or sound levels in rooms with other dimensions, contact the nearest sales office for information. For calculating the width of the air stream, air velocities in the occupied zone or sound levels in rooms with other dimensions, please refer to our web calculation softwares available for download at www.swegon. com. Sound data CONDOR Supply air Sound power level L w (db) (0 m Sabine) Table K OK CONDOR Mid-frequency (octave band) Hz Size (mm) 6 5 50 500 000 000 000 8000 00-600-50 5 9 7 - -6-9 - 800-600-5 6 0 7-5 -7-8 - 00-600-5 5 8-5 -6-7 - 000-600-00x50 7-6 -7-0 -5 00-00-5 6 9 8 - -5-6 - 800-00-600x00 5 8-6 -5-6 -0 00-00-600x00 6 9 8-6 -7 - -9 000-00-800x50 9-7 -0 - -7 Tolerance ± Sound attenuation DL (db) (0 m Sabine) Table DL CONDOR Mid-frequency (octave band) Hz Size (mm) 6 5 50 500 000 000 000 8000 00-600-50 5 0 5 5 800-600-5 9 0 00-600-5 9 0 000-600-00x50 0 6 00-00-5 9 0 800-00-600x00 0 6 00-00-600x00 8 000-00-800x50 6 0 0 0 0 0 Tolerance ± 079 Swegon reserves the right to alter specifications.
Engineering graphs CONDOR Supply air Airflow Pressure drop Sound level Affected area The graphs must not be used for commissioning. The db(a) values are for rooms with normal acoustic absorption of db. The db(c) value is normally 6-9 db s higher than the db(a) value. For more accurate calculations, see the calculation template in the chapter on Acoustics in the Technical Information section of this catalogue. CONDOR Single CONDOR Double p t Pa 00 50 0 0 0 0 5 0 5 0 0 db(a) 5 p t Pa 50 0 0 0 0 5 0 5 0 0 db(a) 5 00 00 00 00 500 l/s 00 00 00 00 500 l/s 000 00 00 500 000 000 m /h 00 500 000 000 m /h 5 l 0, m 5 l 0, m Size designation:. 00-600-50. 800-600-5. 00-600-5. 000-600-00x50 Size designation:. 00-00-5. 800-00-600x00. 00-00-600x00. 000-00-800x50 Swegon reserves the right to alter specifications. 079
Dimensions and weights Size (mm) Weight (kg) 00-600-50 7,0 800-600-5,0 00-600-5 5,0 000-600-00x50 68,0 00-00-5 6,0 800-00-600x00 69,0 00-00-600x00 9,0 000-00-800x50 5,0 9 Figure. CONDOR, dimensions. CL = Centerline. 079 Swegon reserves the right to alter specifications. 5
Order key Product Supply air ceiling system CONDOR a -aaaa -bbb -ccc Version: Nom. length (mm): 00, 800, 00, 000 Nom. width (mm): 600, 00 Nom. connection diam. (mm): Ø 50, 5 Rectangular dimensions (mm): 00x50, 600x00, 600x00, 800x50 Standard range: 00-600-50 800-600-5 00-600-5 000-600-00x50 00-00-5 800-00-600x00 00-00-600x00 000-00-800x50 Specification example Swegon s supply air ceiling system, type CONDOR, with the following functions: Diffuser modules, equipped with nozzles 00% flexible spread pattern Individually adjustable nozzles (55 mm) made from recyclable PP (Polypropylene) plastic VariZon air distribution system Can be cleaned Powder coated in white Backing box that can be cleaned Size: CONDORa - aaaa - bbb - ccc xx items 6 Swegon reserves the right to alter specifications. 079