Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

Similar documents
V-220 / V-320 Heater Kits Installation Instructions TK IM (Rev. 0, 06/17)

Installation Manual. Truck Edition V-520 RT Series Model 10, 20, 30 and 50 Single Temperature Systems. TK IM (Rev.

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

Truck Edition V-520 Series Single Temperature and SPECTRUM Multi-Temperature Systems TK IM (Rev. 11, 03/18)

Truck Edition V-520 RT Series Models 10, 20, 30 and 50 Single Temperature Systems TK IM (Rev. 8, 1/16)

Trailer Edition Precedent S-600M, C-600M and S-600DE with S-2 and S-3 Remote Evaporator Systems TK IM (Rev. 4, 12/15)

Installation Manual. NAD Truck Edition V-200 and V-300 Series. TK IM (Rev. 7, 02/12)

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Truck Edition V-520 Series Single Temperature and SPECTRUM Multi-Temperature Systems TK IM (Rev. 4, 01/12)

Installation Manual. Truck Edition V-500 Series. TK IM (Rev. 3, 01/05) Copyright 2004 Thermo King Corp., Minneapolis, MN, U.S.A.

V Series. Superior Temperature Control. Small trucks and vans

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Installation Manual. SB Domestic Refrigerated Container (DRC) Unit Single Temperature System. TK IM (Rev.

Direct Drive Truck Units. A complete line of refrigeration units for a wide variety of vehicle chassis and applications.

SB Domestic Refrigerated Container (DRC) Unit Single Temperature System TK IM (Rev. 2, 02/13)

V-Series. Superior Temperature Control for Small Trucks and Vans

Operator s Manual. ColdCube TM. TK OP (Rev. 2, 09/2011)

OPERATION & MAINTENANCE MANUAL TX600

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

HEATING AND AIR CONDITIONING

Installation Manual. Truck Edition SPECTRUM Multi-Temperature Systems T-800R, T-1000R and T-1200R (ESA ONLY) T-1000 (TSA)

Installation Manual. Truck Edition UT-1280 Undermount Systems. TK IM (Rev 0, 01/17)

R100 Oil-Less Refrigerant Recovery Unit

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

an ISO 9001:2008 Registered Company ShortPac HEAT/COOL (05000-QUX-A/05000-VUX-A)

REF5-BB Undercounter Blood Bank Refrigerator

INSTRUCTIONS! DO NOT DISCARD!

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

2002 Dodge Caravan SE

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles.

OPERATION & MAINTENANCE MANUAL RHS680

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Installation Manual. Truck Edition SPECTRUM TM TS Multi-Temperature Systems. TK IM (Rev. 11, 05/15)

OPERATION & MAINTENANCE MANUAL AC860

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Heavy Duty Heater / Air Conditioner Model R-8545

-30 C Undercounter Plasma Freezer

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Installation, Operation, and Maintenance Information

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

REFRIGERATOR MODELS: WRT111SFAW00 (White) WRT111SFAB00 (Black) WRT111SFAF00 (Satina) 11/25/ Whirlpool Corporation Part No. W Rev.

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

SB-210+ MAGNUM to be placed

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

347002K/177002K/34900

SECTION 50 - CAB CLIMATE CONTROL

OPERATION & MAINTENANCE MANUAL TC670

SERVICE BULLETIN A

Air Conditioning Operation and Troubleshooting Matt Dunham

Installation Instructions

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

REF Series Undercounter Refrigerator

Harold Ag & Mobile Products

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

SERVICE MANUAL FOR MODEL RM-10

P10KW / P15KW Air Dryer Installation Guide

HEATING AND VENTILATION

SIDE BY SIDE REFRIGERATOR MODELS: WRS325SDHW00 (White) WRS325SDHB00 (Black) WRS325SDHV00 (Black Stainless) WRS325SDHZ00 (Stainless Steel)

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

Service Step by Step Trouble-Shooting Check-List

Nirvana Cycling Refrigerated Dryers

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

CABINET PARTS For Model: JS42CXFXDB00 (Etched Aluminum)

Room Air Conditioner Service and Parts Manual

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

Repair Parts List REFRIGERATOR MODEL NUMBER LTF2112ARB. When requesting service or ordering parts, always provide the following information:

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)


451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

an ISO 9001:2015 Registered Company

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

INSTALLATION MODULE XARIOS RANGE. UTC Climate, Controls & Security PROPRIETARY Rev B 29th mai 2013

INSTALLATION INSTRUCTIONS

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

Refrigerant Recovery Machine. Model No Operating Manual

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Transcription:

Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM (Rev. 0, 06/17)

Installation Manual Truck Edition V-220 / V-320 Series Single Temperature Systems TK 56321-18-IM (Rev. 0, 06/17) Copyright 2017 Thermo King Corp., Minneapolis, MN, U.S.A.

V-220 / V-320 Installation Manual Release History Released 06/17 2

Introduction This manual was written to assist only with the basic installation of a Thermo King V-220 or V-320 condenser unit and ES220 or ES320 remote evaporators onto trucks designed and built for refrigerated applications. The Thermo King Installation Standards and Procedures Guide (TK 56430) provides more detailed information that must be followed to safely and properly complete the entire installation. Due to its complexity, you should not attempt this installation unless you: Are an experienced mechanic. Can safely lift 34 kilos (75 lbs.) Are certified or trained in the repair and maintenance of transport refrigeration systems. Have a basic understanding of electricity and electrical wiring. Have the necessary tools and equipment to complete the installation. Have a truck body designed and built to meet the requirements of this installation. Follow all safety precautions outlined in the Thermo King Installation Standards and Procedures Guide (TK 56430). This manual is published for informational purposes only. Thermo King makes no representations warranties express or implied, with respect to the information recommendations and descriptions contained herein. Information provided should not be regarded as all-inclusive or covering all contingencies. If further information is required, Thermo King Corporation Service Department should be consulted. Thermo King s warranty shall not apply to any equipment which has been so installed, maintained, repaired or altered as, in the manufacturer s judgment, to affect its integrity. Manufacturer shall have no liability to any person or entity for any personal injury, property damage or any other direct, indirect, special, or consequential damages whatsoever, arising out of the use of this manual or any information, recommendations or descriptions contained herein. 3

Table of Contents Introduction.....................................................3 Safety Precautions.............................................. 5 Engine Driven Compressor Installation..............................6 Preparing the Condenser for Installation............................ 7 Condenser Installation............................................9 Evaporator Installation...........................................10 Hose Connections - V-220 10.....................................11 Hose Connections - V-220 MAX 10.................................12 Hose Connections - V-220 20.....................................13 Hose Connections - V-220 MAX 20.................................14 Hose Connections - V-320 10.....................................15 Hose Connections - V-320 MAX 10.................................16 Hose Connections - V-320 20.....................................17 Hose Connections - V-320 MAX 20.................................18 Hose Connections - V-320 MAX 30................................. 19 Hose Connections - V-320 MAX 50................................. 20 Hose Connections to Accumulator Assembly- V-320 MAX 30 / MAX 50.. 21 Wiring Connections - V-220/V-320 10 & MAX 10...................... 22 Wiring Connections - V-220/V-320 20 & MAX 20...................... 23 Wiring Connections - V-320 MAX 30 & MAX 50...................... 24 In-Cab Controller Installation..................................... 25 Standby Receptacle Box Installation (Models 20 and 50 Only).......... 26 Evaporator Drain Hose Installation................................. 27 Completing the Installation....................................... 28 Suction Pressure Regulator (SPR) Adjustment Procedures - MAX 20.... 29 Compressor Pressure Regulator (CPR) Adjustment Procedures - MAX 30 30 Compressor Pressure Regulator (CPR) Adjustment Procedures - MAX 50 31 Compressor Oil Amounts and Type................................ 32 4

Safety Precautions IMPORTANT: Additional Safety Precautions must be followed when installing this unit. See Section 2 - Safety Precautions in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). Recover Refrigerant At Thermo King, we recognize the need to preserve the environment and limit the potential harm to the ozone layer that can result from allowing refrigerant to escape into the atmosphere. We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere. In addition, service personnel must be aware of Federal regulations concerning the use of refrigerants and the certification of technicians. For additional information on regulations and technician certification programs, contact your local THERMO KING dealer. CAUTION Thermo King condenser units and remote evaporators are shipped with a 35 kpa (5 psi) holding charge of Helium. This holding charge may be safely vented into the atmosphere. CAUTION: SEVERE COMPRESSOR DAMAGE will result from operating the unit before completing the installation which includes: installing the components, releasing the holding charge, connecting refrigeration lines, leak testing, evacuation, clean-up and charging of the system with the proper amount and type of refrigerant. 5

Engine Driven Compressor Installation IMPORTANT: See Section 5 - Compressor Selection and Installation Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLOWED! IMPORTANT: Failure to add the correct amount and type of oil will damage the compressor. See Compressor Oil Amounts and Type on page 32. 6

Preparing the Condenser for Installation Cover and Fan Housing Removal (All Models) Remove plastic condenser cover and fan housing assembly to access the unit mounting holes. Fan Housing Modifications (Nosemount Installations Only) Turn fan housing over and use a hand saw to trim the area shown for refrigeration hose clearance. NOTE: The fan housing assembly will be reinstalled later. 7

Preparing Condenser for Installation ALL MODELS - The oil separator and the dehydrator must be removed to access refrigeration fittings that hoses will be attached to later. NOTE: For nosemount or rooftop installations that may require the harness be re-routed from exiting the bottom of the condenser, first remove the wires with ring terminals from the three (3) ground studs to avoid damaging them. Apply dielectric grease to ground studs and re-connect ground wires after relocating harness. MODELS 20 and 50 ONLY - The power tray must be moved to access unit mounting holes. 1. Remove wires 2R and CH from capacitor. 2. Disconnect 2-pin plug and slide harness out of the grommet. 3. Remove two screws and one nut securing the tray. 4. Lift tray up off the mounting stud and swing out of the way. NOTE: All components removed will be reinstalled later. 8

Condenser Installation IMPORTANT: See Section 4 - Unit Installation Standards and Procedures in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! MODELS 20 and 50 ONLY - After installing condenser, reinstall power tray and reconnect electrical wires removed earlier. Ensure 2R goes back on the (+) terminal and CH goes back on the (-) terminal. 9

Evaporator Installation IMPORTANT: See Section 4 - Unit Installation Standards and Procedures in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! Standard Evaporator - Minimum Distance from cargo wall to rear of evaporator shown. Evaporator with Accumulator - Minimum Distance from cargo wall to rear of accumulator shown. 10

Hose Connections - V-220 10 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 11

Hose Connections - V-220 MAX 10 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 12

Hose Connections - V-220 20 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 13

Hose Connections - V-220 MAX 20 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 14

Hose Connections - V-320 10 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 15

Hose Connections - V-320 MAX 10 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 16

Hose Connections - V-320 20 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 17

Hose Connections - V-320 MAX 20 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 18

Hose Connections - V-320 MAX 30 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! See Hose Connections to Accumulator Assembly- V-320 MAX 30 / MAX 50 on page 21 19

Hose Connections - V-320 MAX 50 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! See Hose Connections to Accumulator Assembly- V-320 MAX 30 / MAX 50 on page 21 20

Hose Connections to Accumulator Assembly- V-320 MAX 30 / MAX 50 IMPORTANT: See Section 6 - Refrigerant Hose and Fittings Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 21

Wiring Connections - V-220/V-320 10 & MAX 10 IMPORTANT: See Section 7 - Electrical Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 22

Wiring Connections - V-220/V-320 20 & MAX 20 IMPORTANT: See Section 7 - Electrical Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430).THESE PROCEDURES MUST BE FOLLOWED! 23

Wiring Connections - V-320 MAX 30 & MAX 50 IMPORTANT: See Section 7 - Electrical Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! 24

In-Cab Controller Installation IMPORTANT: IMPORTANT: Electrical See Section Standards 7 - Electrical must Standards be followed. in See the Thermo Section 7 King of the Vehicle Thermo Powered King Vehicle Truck Installation Powered Truck Standards Installation and Procedures Standards and Guide (TK Procedures 56430). Guide THESE (TK PROCEDURES 56430). MUST BE FOLLOWED! Attach connector to controller making sure it locks securely in place. Secure any excess harness adequately with band wraps. 25

Standby Receptacle Box Installation (Models 20 and 50 Only) IMPORTANT: See Section 7 - Electrical Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! Typical receptacle installation with correct drip loop shown. 26

Evaporator Drain Hose Installation IMPORTANT: See Section 8 - Evaporator Drain Hose Standards in the Thermo King Vehicle Powered Truck Installation Standards and Procedures Guide (TK 56430). THESE PROCEDURES MUST BE FOLLOWED! Attach drain hoses onto both evaporator drain tubes and combine into a single hose using supplied Y-connector. ES320 MAX 30 and 50 ONLY These evaporators are equipped with accumulator assembly which includes a separate drain hose. This drain hose must be connected along with the other two drain hoses using T and Y connectors. 27

Completing the Installation IMPORTANT! TO COMPLETE THE INSTALLATION, YOU MUST PERFORM THE FOLLOWING PROCEDURES PER THE THERMO KING INSTALLATION STANDARDS AND PROCEDURES GUIDE (TK 56430): SYSTEM EVACUATION PROCEDURES SYSTEM LEAK CHECK PROCEDURES SYSTEM CHARGING PROCEDURES CONFIGURATION SOFTWARE PROCEDURES 28

Suction Pressure Regulator (SPR) Adjustment Procedures - MAX 20 IMPORTANT: All new unit installations require these adjustment procedures. Failure to do so may not allow the unit to operate at its maximum capacity. NOTE: The following procedures are for initial settings. Sometimes conditions such as high or low ambient temperatures may require that the settings be fine-tuned for optimum performance. MAX 20 units are equipped with a suction pressure regulator (SPR) valve located in the evaporator. The valve is used to limit the load on the standby compressor. This also affects the current draw of the electric motor. Monitor the current drawn of the electric motor when making this adjustment. 1. Install gauge manifold set on electric standby compressor. Attach additional compound gauge on suction service port located on copper suction tube in evaporator to monitor suction pressure going to the SPR valve. 2. Connect clamp on amp meter to T1 (Black) motor wire on a 115V/230V 1 PH unit, or to the leg of the highest voltage motor wire of a 230V 3 PH unit. 3. Connect standby power receptacle to an appropriate electric power source. 4. Place jumper wire between the 12 and CHB wires at the defrost termination switch to ensure the unit will run in defrost. 5. Start unit and run in defrost on the electric standby compressor until the pressure on the additional compound gauge attached to the suction service port stabilizes at a pressure above 45 psig (310 kpa). 6. Check the suction pressure on the gauge attached to the suction service port at the standby compressor. It should be 24 ± 2 psig (165 ± 14 kpa) without exceeding the following current draws: 7. If the pressure is not within range, or the current is above the specific values, remove the protective cap and adjust the SPR valve to the correct setting. 8. Remove gauge manifold set, the additional compound gauge, and the jumper wire when finished with the procedure. 115 VAC 14 Amps 230 VAC 1 PH 9.5 Amps 230 VAC 3 PH 7 Amps Figure 1: MAX 20 SPR Valve and Service Port Locations 29

Compressor Pressure Regulator (CPR) Adjustment Procedures - MAX 30 IMPORTANT: All new unit installations require these adjustment procedures. Failure to do so may not allow the unit to operate at its maximum capacity. NOTE: The following procedures are for initial settings. Sometimes conditions such as high or low ambient temperatures may require that the settings be fine-tuned for optimum performance. MAX 30 units are equipped with a compressor pressure regulator (CPR) valve located in the accumulator module mounted on the back of the evaporator. It is used to limit the suction pressure during heat. 1. Install a gauge manifold set on the engine driven compressor. Attach an additional compound gauge to the accumulator suction service port to monitor suction pressure after the CPR valve. 2. Place a jumper wire between the 12 and CHB wires at the defrost termination switch to ensure the unit will run in defrost. 3. Start the unit and run it in defrost on the electric standby compressor until the pressure on the additional compound gauge attached to the suction service port stabilizes at a pressure above 45 psig (310 kpa). 4. Check the suction pressure on the gauge attached to the suction service port at the compressor. It should be 24 ± 2 psig (165 ± 14 kpa). If the setting is incorrect, remove the protective cap and adjust the compressor pressure regulator valve to the correct setting. 5. Remove the gauge manifold set and the additional compound gauge when finished with the test. Figure 2: MAX 30 CPR Valve and Service Port Locations 30

Compressor Pressure Regulator (CPR) Adjustment Procedures - MAX 50 IMPORTANT: All new unit installations require these adjustment procedures. Failure to do so may not allow the unit to operate at its maximum capacity. NOTE: The following procedures are for initial settings. Sometimes conditions such as high or low ambient temperatures may require that the settings be fine-tuned for optimum performance. MAX 50 units are equipped with a compressor pressure regulator (CPR) valve located in the accumulator module mounted on the back of the evaporator. The valve is used to limit the load on the standby compressor. This also affects the current draw of the electric motor. Monitor the current drawn of the electric motor when making this adjustment and keep it at least 1.5 amps below the overload relay setting. 1. Install gauge manifold set on electric standby compressor. Attach additional compound gauge on suction service port located on copper suction tube in evaporator to monitor suction pressure going to the CPR valve. 2. Connect clamp on amp meter to T1 motor wire on a 115V/230V 1 PH unit, or to the leg of the highest voltage motor wire of a 230V 3 PH unit. 3. Connect standby power receptacle to an appropriate electric power source. 4. Place jumper wire between the 12 and CHB wires at the defrost termination switch to ensure the unit will run in defrost. 5. Start unit and run in defrost on the electric standby compressor until the pressure on the additional compound gauge attached to the suction service port stabilizes at a pressure above 45 psig (310 kpa). 6. Check the suction pressure on the gauge attached to the suction service port at the standby compressor. It should be 24 ± 2 psig (165 ± 14 kpa) without exceeding the following current draws: 7. If the pressure is not within range, or the current is above the specific values, remove the protective cap and adjust the CPR valve to the correct setting. 8. Remove gauge manifold set, the additional compound gauge, and the jumper wire when finished with the procedure. 115 VAC 14 Amps 230 VAC 1 PH 9.5 Amps 230 VAC 3 PH 7 Amps Figure 3: MAX 50 CPR Valve and Service Port Locations 31

Compressor Oil Amounts and Type IMPORTANT: FAILURE TO ADD THE CORRECT AMOUNT AND TYPE OF OIL WILL DAMAGE THE COMPRESSOR Oil Capacity Chart for Units Utilizing Swash Plate Compressors Oil Supplied in Unit Oil Added at Installation Model Compressor Type System Oil (oz.) Standby Compressor (oz.) Add to Roadside Compressor (oz.) Add to Suction Line (oz.) Total Oil Added at Installation (oz.) Total System Capacity (oz.) Oil Type V-220 / V-320 10 TK 13 / TK 15 5-4 4 8 13 POE 120 V-220 / V-320 20 TK 13 / TK 15 5 4 4 4 8 17 POE 120 V-320 30 TK 15 5-4 8 12 17 POE 120 V-320 50 TK 15 5 4 4 8 12 21 POE 120 NOTE: If utilizing a discharge muffler add an additional 3 oz. of oil during installation or repair. Oil Capacity Chart for Units Utilizing Reciprocating Compressors Oil Supplied in Unit Oil Added at Installation Model Compressor Type System Oil (oz.) Standby Compressor (oz.) Add to Roadside Compressor (oz.) Add to Suction Line (oz.) Total Oil Added at Installation (oz.) Total System Capacity (oz.) Oil Type V-220 / V-320 10 TK 208 5-17 8 25 30 POE 120 V-220 / V-320 20 TK 208 5 4 17 8 25 34 POE 120 V-320 30 TK 208 5-17 12 29 34 POE 120 V-320 50 TK 208 5 4 17 12 29 38 POE 120 NOTE: If utilizing a discharge muffler add an additional 3 oz. of oil during installation or repair. 32

2017 Ingersoll-Rand Company Printed in U.S.A. on Recycled Paper Ingersoll Rand s Climate Solutions sector delivers energy-efficient HVACR solutions for customers globally. Its world class brands include Thermo King, the leader in transport temperature control and Trane, a provider of energy efficient heating, ventilating and air conditioning systems, building and contracting services, parts support and advanced controls for commercial buildings and homes.