Considerations for INDUSTRIAL COMBUSTION

Similar documents
HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

Cleaver-Brooks Webinars

Rental Boiler Specifications (Nebraska Boiler)

PROFIRE -E SERIES BURNERS

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Ohio Energy. Workshop HH. Strategies & Technologies to Improve the Boiler Room Efficiency. Wednesday, February 21, p.m. to 3:15 p.m.

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

Guidelines for Preparing for a Temporary Steam Plant

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

Distributed By: M&M Control Service, Inc Building Technologies

Power Flame Incorporated

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

Power Flame Incorporated

PACKAGED COMMERCIAL WATERTUBE BOILERS

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

- Essay Control Functions and Benefits

Honeywell SLATE ICM Platform

Best Practices for Condensing Boilers

1 INTRODUCTION SYSTEM DESCRIPTION... 3

MODULATING CONTROL OF LOW NO X BURNERS

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

HCLEARFIRE. High-efficiency, modular steam boiler HP

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

HYDROCARBONENGINEERING June June 2015

Model CB-LE. Packaged Boiler HP. Operation, Service, and Parts Manual /09. and Model CB Ohio Special HP

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

05/14/2012 BOILER TUNE UPS & REPLACEMENTS PRESENTATION BOILER BASICS FOR LARGE INDUSTRIAL FACILITIES. Mark Bergum, P.E.

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

ALDRICH COMPANY THREE PASS FIRETUBE BOILER CLASSIC SERIES OPERATING & MAINTENANCE MANUAL

- Data Brochure Universal Reset Module 422

Boiler Draft Equipment

CONTENTS. B. System Design and Performance Requirements

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Trials Tribulations & Rewards High T Heating Systems

Zeeco recently had the opportunity

Super Boiler. > Gas Technology Institute Cleaver-Brooks Inc. May WHO WE ARE Gas Technology Institute

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

ABB. Fuel Air Ratio Controls (FARC) Canadian Boiler Society 2018 Education Days. Glen Harrison Regional Sales Manager, Power Generation ABB Inc.

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Energy Management and Controls

How about Savings in Time, Money, Energy and Longer Life?

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

SECTION HEATING BOILERS

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Section 1 Overview. Introduction 1-1

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Complete burner management in a compact, affordable system

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

SAMPLE SPECIFICATIONS

Williams & Davis Boilers

- Data Brochure Universal Reset Module 423

MCH Series Drives. HVAC Application Guide. ag-mch-e2

Boiler Walkdown Field Device Checklist. Customer. Date

Pulse Firing Doubles Capacity and Cuts Fuel Costs

SECTION Boiler Controls & Waste Heat Recovery

Zantingh Burner systems. Reliable energy-saving and environmentally friendly heating solutions

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

HFID Heated Total Hydrocarbon Analyzer Module

HAWK INTEGRATED BOILER CONTROL SYSTEM

Boiler Technical Specifications (2013)

CONTROL SYSTEM D ESIGN, E NGINEERING & C ONSTRUCTION.

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

SLATE. Integrated Combustion Equipment Management Success Stories

Draft Controls. When to use a Draft Control

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

INDUSTRIAL WATERTUBE BOILERS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Diocese of Cleveland Facilities Services Corporation

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

A TRUE GAME CHANGER - The Vortex Heat Recovery Center CONDENSING EFFICIENCIES FOR TRADITIONAL BOILERS & HEATERS

the New Industrial Steam Generation System

Complete Boiler Management in a Compact, Affordable System

The world s standard in efficiency. CBEX FIRETUBE

PROPOSED October 15, 2013

Green Energy Engineering, Inc.

Installation & Operation Manual

Development of Boiler Design

GAS/LOW NOx SERIES. High or Low Pressure Steam Boiler. The most versatile industrial steam boiler in the world

ADDENDUM # 2 TO RFP #

Williams & Davis Boilers

RULE 3.23 NATURAL GAS-FIRED WATER HEATERS, SMALL BOILERS, AND PROCESS HEATERS (Adopted 10/03/2016)

NEW LINE BOILER CONTROLLERS

SECTION INSTRUMENTATION AND CONTROL FOR BOILER PLANT

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Job Name Control Systems Description Date

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Transcription:

August 2016 Volume 23, Number 8 Considerations for INDUSTRIAL COMBUSTION Systems Follow us on:

COMBUSTION CONTROLS FOR BOILERS Understand the advantages and disadvantages of combustion control schemes used on the burners for industrial watertube and firetube boilers. By Brett Barnes, Nationwide Boiler Inc. Steam generated from boilers is used in many industrial processes, including manufacturing, refining, chemical processing and power generation. The burner is the heart of a boiler system, providing the necessary combustion of fossil fuels. Yet, if the burner is the heart, then the combustion controls which manage air and fuel flow to the burner are the brains of the boiler system. Airflow must be controlled and balanced, and sufficient quantity must be provided to ensure complete fuel combustion with minimal unburned hydrocarbons. At the same time, too much airflow can decrease boiler efficiency. This balance is determined by the combustion control scheme. This article will discuss the typical combustion control schemes that are used on watertube and firetube boilers and present advantages and disadvantages for each scheme. For the purpose of discussion, it is assumed that the burner fuel is either gaseous or liquid (oil), not a solid fuel. Also, it is assumed that there is one burner per boiler and that there is a combustion-air fan (the burner is not a natural-draft design). Burners can be thought of as fuel and air blenders. It is the burner s job to mix the air and fuel properly so that all the fuel is burned. Stoichiometric airflow can be calculated based on a fuel composition. For example, natural gas composition is mostly methane with smaller amounts of ethane, nitrogen, carbon dioxide and other gases. The stoichiometric air-to-fuel ratio for natural gas is approximately 16 lb of air per pound of fuel. Burner airflow also includes excess air. This is the amount of airflow added to the stoichiometric airflow requirement. It is typically 10 to 15 percent, depending upon the burner design characteristics. Excess air is necessary to ensure the fuel is completely burned. However, as stated above, it also needs to be minimized as the extra flow decreases boiler efficiency. The three basic types of combustion control schemes are: Single-point positioning. This scheme also is called linkage. Parallel positioning. This scheme also is called called linkageless. Metering. Let s take a closer look at each, from lowest to highest cost. Single-Point Positioning Single-point positioning (SPP) combustion control is the easiest to understand and the easiest to maintain from an operational 30 AUGUST 2016 Process Heating

FIGURE 1. This small burner has single-point positioning combustion controls. www.process-heating.com AUGUST 2016

standpoint. Fuel and air and sometimes flue-gas recirculation are mechanically linked using a jackshaft with linkage arms to form an all-mechanical system. (Fluegas recirculation, or FGR, is one method used to reduce burner NO X emissions. It involves redirecting some of the stack gases or flue gases back through the burner.) Combustion control with single-point positioning typically is used on smaller units, including watertube boilers sized at 50,000 pph and less as well as firetube boilers that are 800 hp or less. The main jackshaft is modulated based upon the firing-rate demand. This, in turn, moves the air and fuel linkage arms, opening and closing the air damper and fuel control valve (figure 1). These linkage movements control the firing rate of the burner. The firing-rate demand is a function of the steam demand from the boiler. For boilers, the industry standard is to calculate demand based on steam pressure. An error function is generated using the difference between the setpoint value and the measured value. For example, if the setpoint is 150 psig, and the boiler pressure is actually 130 psig, the error is 20 psig. This means that the burner has to fire harder to meet demand. The demand signal, which is what determines the firing rate of the burner, typically is calculated using an algorithm with proportional, integral and derivative functions, also known as PID control. The proportional function takes the error value (20 psig in the previous example) and applies a constant or a gain to the signal. The integral function uses the accumulation or summation of past error values to give a corrective action based upon past performance. The derivative function deals with possible future error values, giving a predictive correction. Single-point positioning combustion control uses a single PID loop, meaning there is one input and one output. The input is the boiler pressure, and the output is the firing-rate demand. Two big advantages of this system include the simplicity and ease of maintenance. In addition, it is safe: If the jackshaft drive unit failed, it would fail in position at the mechanically set air-fuel ratio. The disadvantages include: The hysteresis effect. This is where, over time, the linkage connections get worn, causing inaccurate positioning of dampers or valves. All devices need to be physically close to each other due to limitations on linkage lengths. Frequent adjustment can be required. Because this system does not apply any correction for changes in air (or fuel) density, the boiler system typically requires retuning (i.e., readjustment of air and fuel linkage settings) at least twice a year when the average ambient temperature changes. It also means that the boiler may not operate as efficiently as possible because changes in air density will cause flow variances for a fi xed air damper position. FIGURE 2. The metering system uses an airflow measurement device. Parallel Positioning Parallel positioning combustion control is a step up in complexity and cost from the single-point positioning combustion control system. Instead of air and fuel devices linked together, individual actuators drive 32 AUGUST 2016 Process Heating

FIGURE 3. A metering system employs a fuel flow measurement device. each item. A sample system could include a pneumatically operated fuel control valve, a pneumatically operated air damper actuator and a variable-frequency drive (VFD) to modulate the fan speed. A key requirement to this system is position feedback. Because it is not mechanically linked, each device needs to provide proof of position to ensure enough airflow is being provided. Similar to single-point positioning combustion control, this is also a single PID loop. The only difference is that there are multiple outputs one for each device. For example, for a simple gas-only system with no FGR, the input would be steam pressure. The outputs would be the fuel gas control valve position and the air damper actuator position. Once again, position feedback would be used as inputs into the system to confirm device position. By adding an extra PID loop, air density correction can be incorporated using O 2 trim. A stack O 2 probe (which indicates burner excess air) would be the input, and the output would be a correction to the airflow signal (typically a ±10 percent multiplier). This would help maximize boiler efficiency because the airflow is adjusted as the ambient air temperature changes. Another efficiency-saving device is a fan VFD. Combustion-air fan-power requirements are greatly reduced at lower boiler loads by reducing fan speed. The fan laws state that power is proportional to the ratio of fan speeds raised to the third power. For instance, if the fan is running at half speed, the power savings can be as high as one-half to the third power, or one-eighth of the original amount. This can be a significant reduction in the electricity bill. The advantages of this system include the potential efficiency savings and the ability to be applied to larger boilers. The main disadvantage is the potential for air and fuel flows to get out of adjustment, which creates an unsafe situation. (However, this risk is mitigated using position feedback.) This system is also more complex, requiring more qualified operational personnel than what is needed for singlepoint positioning combustion control. Metering Metering is the best system for boiler efficiency, but it is also the most complex and the most costly. It is similar to parallel positioning in the fact that the air and fuel devices are driven by individual actuators, but now air and fuel flow meters are added (figure 2 and 3). The flow meters provide fast-acting feedback signals to the system, which can influence fuel or air flow changes in many ways. For example, if foreign matter was induced into the fan inlet and blocked part of the flow, airflow www.process-heating.com AUGUST 2016

With single-point positioning, the boiler may not operate as efficiently as possible because changes in air density throughout the year will cause flow variances. A metering scheme is the best system for boiler efficiency. would be restricted and the airflow meter would detect this. Also, metering systems have an extra safety feature called cross limiting. This function checks that fuel flow is always less than the measured airflow, and airflow is always more than the measured fuel flow. There are more PID loops with this system: one for the steam pressure (this is the firing-rate demand), one for each fuel, and one for air. The fuel-loop inputs would be firing-rate demand and fuel flow. The output would be fuel control valve position. Similarly, air-loop inputs would be firing-rate demand and airflow. The output would be air damper actuator position. O 2 trim and fan VFD also can be added for increased boiler efficiency. A metering scheme is the best system for boiler efficiency. The main disadvantage is that it is the most complex system, requiring qualified operational personnel and increased maintenance. The selection of the burner control system can affect boiler operation, maintenance and efficiency. A single-point positioning scheme is the least expensive and simplest system available while a metering scheme is the most costly and complex. It also is the most efficient option. A parallel-positioning scheme falls right in the middle of the two in regards to cost and complexity. The ability to be applied to larger boiler systems provides both parallel positioning and metering with an added advantage. Evaluate your specific situation and use this information as a guide to assist in the selection process for your boiler burner control system. Brett Barnes is a sales and project engineer with Nationwide Boiler Inc., Fremont, Calif. For more information from Nationwide Boiler, call 800-227-1966 or visit www.nationwideboiler.com. 34 AUGUST 2016 Process Heating