WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

Similar documents
WRF04 CO 2 RS485 Modbus

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

LCF Touch (from firmware version 1.7)

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

LCF Touch Modbus Datasheet Application Security Advice Caution

Air Quality. Sample applications 243 CO2 VOC CO2+VOC. Air Quality

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Room air quality sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

User's Guide. CO 2 Monitor. Model CO200

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

esense CO2 Transmitter and Alarm

KANE-ALERT-CO 2 Monitor with Temperature

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Multifunction IAQ Monitor

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

Duct and Rough Service Carbon Monoxide Sensor

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Room Air Quality Sensors

CDL 210. Operating manual. CO2 Logger. Best.-Nr

02/11/2015

Datasheet: K-22 LO Sensor

PROCESS ANALYSERS. SERVOFLEX MiniMP (5200) Gas Analyser. Operator Manual. Part Number: A Revision: 8 Language: UK English

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Introduction. OM-THA2

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Duct Air Quality Sensors

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Carbon Monoxide CO Transmitter ADT-X3-1110

02/11/2015

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Model OEM-2 INSTRUCTIONS FOR USE

Recalibrate the way you look at gas detection

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Danfoss gas detection units

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

USER MANUAL Digital CO Monitor Model CO30

Instruction Manual CHHC-1

RSMFM-2R MULTIFUNCTIONAL

RE-PR3-E-27 3-Phase Panel Mount 27kW

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Networkable Fan Coil Controller Specification and Installation Instructions

Gas cylinder scale Model GCS-1

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

QPM21 Series Duct CO 2 and Air Quality Sensors

CMT MANUAL 6. NMC SENSORS

DGS - Danfoss Gas Sensor Check / Calibration Procedure

HPLC Column Ovens and Temperature Controllers

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Two-Channel Gas Controller

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

EasyLog Data Logger Series

Products. World Edition

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

IR25 Dual Gas Series Datasheet

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Model D12-IR. Digital Gas Transmitter...

Sensor unit MC2 with analog output for Freon gases and refrigerants

GL-CO-RFG Channel Gas Leak Alarm System

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Superdew 3. Hygrometer. Operating Instructions

EasyLog Data Logger Series

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

LC2200 Level Controller Installation and Maintenance Instructions

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Semi flush-mount room thermostats

TLS 500. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.1.

Danfoss gas detection units

FR-A180 FR-A360. Occupancy detector. Use

CHILLGARD M-100. Refrigerant Sensor. Operating Manual. Order No.: /02

Installation and user manual

Allure EC-Smart-Air Series Communicating sensors

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Transcription:

WRF04 CO2 Combined room sensor CO 2 / temperature / humidity 281836 Datasheet Subject to technical alteration Issue date: 26.02.2016 Application Surface mounted sensor for detection of CO2, temperature and optional relative humidity in room and office spaces. For direct connection to a DDC or a monitoring system, using 0..10 V outputs. Also available with traffic light LED and LCD display. Types Available WRF04 CO2 VV 2x outputs 0..10 V / temperature, CO 2 Optional 3xV 3x outputs 0..10 V / temperature, CO 2, humidity WRF04 CO2 xx LCD LCD for displaying measuring values TLF R 3 LEDs for displaying level of CO 2 concentration Potential free relay output (NO) for 24 V ~ or 24 V = / 2 A with adjustable CO2 threshold value Security Advice Caution The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorised modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual

Page 2 / 6 Issue date: 26.02.2016 Notes on Disposal As a component of a large-scale fixed installation, Thermokon products are intended to be used permanently as part of a building or a structure at a pre-defined and dedicated location, hence the Waste Electrical and Electronic Act (WEEE) is not applicable. However, most of the products may contain valuable materials that should be recycled and not disposed of as domestic waste. Please note the relevant regulations for local disposal. Remarks to Room Sensors Location and Accuracy of Room Sensors The room sensor should be mounted in a suitable location for measuring accurate room temperature. The accuracy of the temperature measurement also depends directly on the temperature dynamics of the wall. It is important, that the back plate is completely flush to the wall so that the circulation of air occurs through the vents in the cover. Otherwise, deviations in temperature measurement will occur due to uncontrolled air circulation. Also the temperature sensor should not be covered by furniture or similar devices. Mounting next to doors (due to draught) or windows (due to colder outside wall) should be avoided. The temperature dynamics of the wall will influence the temperature measurement. Various wall types (brick, concrete, dividing and hollow brickwork) all have different behaviours with regards to thermal variations. Surface and Flush Mounting The temperature dynamics of the wall influence the measurement result of the sensor. Various wall types (brick, concrete, dividing and hollow brickwork) have different behaviours with regard to thermal variations. A solid concrete wall responds to thermal fluctuations within a room in a much slower way than a light-weight structure wall. Room temperature sensors installed in flush boxes have a longer response time to thermal variations. In extreme cases they detect the radiant heat of the wall even if the air temperature in the room is lower for example. The quicker the dynamics of the wall (temperature acceptance of the wall) or the longer the selected inquiry interval of the temperature sensor is the smaller the deviations limited in time are. Build-up of Self-Heating by Electrical Dissipative Power Temperature sensors with electronic components always have a dissipative power, which affects the temperature measurement of the ambient air. The dissipation in active temperature sensors shows a linear increase with rising operating voltage. This dissipative power has to be considered when measuring temperature. In case of a fixed operating voltage (±0,2 V) this is normally done by adding or reducing a constant offset value. As Thermokon transducers work with a variable operating voltage, only one operating voltage can be taken into consideration, for reasons of production engineering. Transducers 0..10 V / 4..20 ma have a standard setting at an operating voltage of 24 V =. That means, that at this voltage, the expected measuring error of the output signal will be the least. For other operating voltages, the offset error will be increased by a changing power loss of the sensor electronics. If a re-calibration should become necessary later directly on the sensor, this can be done by means of a trimming potentiometer on the sensor board. Remark: Occurring draft leads to a better carrying-off of dissipative power at the sensor. Thus temporally limited fluctuations might occur upon temperature measurement. Application Notice for Humidity Sensors Refrain from touching the sensitive humidity sensor/element. Touching the sensitive surface will void warranty. For standard environmental conditions re-calibration is recommended once a year to maintain the specified accuracy. When exposed to high ambient temperature and/or high levels of humidity or presence of aggressive gases (i.e. chlorine, ozone, ammonia) the sensor element may be affected and re-calibration may be required sooner than specified. Re-calibration and deterioration of the humidity sensor due to environmental conditions are not subject of the general warranty. Information about Indoor Air Quality CO 2 EN 13779 defines several classes for indoor air quality: Category CO 2 content above the content in outdoor air in ppm Description Typical range Standard value IDA1 <400 ppm 350 ppm Good indoor air quality IDA2 400.. 600 ppm 500 ppm Standard indoor air quality IDA3 600..1.000 ppm 800 ppm Moderate indoor air quality IDA4 >1.000 ppm 1.200 ppm Poor indoor air quality

Issue date: 26.02.2016 Page 3 / 6 Information about Self-Calibration Feature CO 2 All gas sensors are subject to drift caused by components. This fact results generally in the need to recalibrate the sensors regularly. With dual channel technology Thermokon integrates automatic self-calibration for different fields of operation. In contrast to common used ABC-Logic sensors with self-calibration dual channel are suitable for applications operating 24 hours, 7 days a week as for example hospitals. Manual calibration is not necessary! Technical Data Measuring values CO2, temperature, humidity Output voltage VV 2x 0..10 V (min. load 10 kω) 3xV 3x 0..10V (min. load 10 kω) Power supply 15..24 V = (±10%) or 24 V~ (±10%) Power consumption max. 3 W (24 V = 6 VA (24 V =) Measuring range temperature 0..+50 C Measuring range humidity 0..100% rh non-condensing Measuring range CO2 0..2000 ppm Accuracy temperature ±1% of measuring range (typ. at 21 C) Accuracy humidity ±2% between 10..90% rh (typ. at 21 C) Accuracy CO2 ±75 ppm or 10% of measuring range (typ. at 21 C), whatever is greater Calibration self-calibration, dual channel Sensor NDIR (non-dispersive, infrared) Display LCD 29x12 mm, monochrome (optional) 3 LEDs showing air quality (traffic light function TLF ) (optional) Enclosure PC, pure white Protection IP30 according to EN 60529 Cable entry breaking points top/bottom, entry on rear Conenction electrical terminal block, max. 1,5mm² Ambient condition 0..+50 C, max. 85% rh non-condensing Weight 90 g Mounting to be mounted flat onto the surface using adhesive foil or screws Notes relay R (optional): floating, max. 24 V / 2 A (ohmic) Connection plan

Page 4 / 6 Issue date: 26.02.2016 Clamp Type WRF04 CO2 VV Type WRF04 CO2 3xV 1 GND/AC2 GND/AC2 2 UB +24 V ~/AC1 UB +24 V ~/AC1 3 Temp. 0..10 V Temp. 0..10 V 4 CO 2 0..10 V CO 2 0..10 V 5 Not used Rel. humidity 0..10 V 6 Not used Not used 7 Not used Not used 8 relay C (only option -R) relay C (only option -R) 9 relay NO (only option -R) relay NO (only option -R) 10 relay NC (only option -R) relay NC (only option -R) Functions description Traffic light function (optional) The LEDs visualize the air quality 0..33% 0..750 ppm green LED flashing 34..66% 751..1250 ppm yellow LED flashing 67..100% 1251..2000 ppm red LED flashing Configuration P1 Offset temperature ±3 K P2 Offset CO 2 ±150 ppm P3 Offset rel. humidity ±15% rh mode switch position 0 CO 2 set point for relay option mode switch position 2 For configuration set mode switch to the appropriate position and then choose offset or set point using P1 to P3. With changing P1 to P3 the value is stored in the device. Changing set point will not change offset for rel. humidity, if the mode switch has been set to the correct position.

Issue date: 26.02.2016 Page 5 / 6 Mounting Advices Make sure that the device is power-off, if you install it! The device can be installed on a smooth wall surface or a flush box. A representative location for room temperature without direct insolation should be selected for the device. The use of deep installation boxes is recommended due to increased storage capacity for the wires. Empty tubes have to be sealed to avoid air draught from the installation tube. (1) For wiring, the upper part of the base plate has to be removed. Base plate and upper part are connected via snap tab located in the middle of the enclosure bottom. (2) The installation of the base plate to the smooth wall surface can be done either by sticking using the enclosed adhesive film (A) as well as using plugs and screws. (3) Finally the device is clicked into the base plate.

Page 6 / 6 Issue date: 26.02.2016 Dimensions (mm) Accessories Rawlplugs and screws (2 pcs. each) Item No.: 102209 Frame for surface mounting WRF04 Item No.: 111584 Ball stroke protection BS100 Item No.: 103312