Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Similar documents
2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Installer s Guide Convertible Air Handlers 1-1/2 5 Ton

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

INSTALLER S GUIDE WARNING: TWE-IN-2A 18-GE02D1-3. Convertible 1 ½ - 5 Ton Air Handlers WARNING HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

R-410A. Installer s Guide WARNING: 18-GE04D2-5

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Installation Instructions

C7 Series Split System Uncased Indoor Coils

INSTALLATION INSTRUCTIONS

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS

Installation Instructions

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

IMPORTANT This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instruction

Installation Instructions

PL Series Premier Indoor Plenum Coils

UPFLOW/DOWNFLOW COILS

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

Cooling/Heat Pump Convertible Air Handlers

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Installation Instructions

Upflow/Downflow A-Coil Specifications

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

Cooling/Heat Pump Convertible Air Handlers

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

EarthLinked AVN Series Air Handlers Installation Manual

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

WineZone Ceiling Mount Ductless Split 15

Installation Instructions

Installation Instructions

EarthLinked AFN Series Air Handlers Installation Manual

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INSTALLATION INSTRUCTIONS

SERVICE BULLETIN A

Modular Multi-position Air Handler

AVS Air Handlers Installation Manual for Classic SC, SD, and SDH

Installation Owner Diagnostics

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

INSTALLATION INSTRUCTIONS

Fig. 1--Typical Coil Installation

Evaporator Coil. Installation Instructions GENERAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR RCQD COILS

CBX32MV (HFC-410A) SERIES UNITS

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

Installation Instructions

Evaporator Coil. Installation Instructions GENERAL

Cooling/Heat Pump Convertible Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Installation Instructions

Installation Instructions

Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

_"RETURN. s ) EVAPORATOR COIL _ DOWNFLOW FURNACE UPFLOW I R I! / _[_SUPPLY

INSTALLATION INSTRUCTIONS

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Vertical Upflow Horizontal Left Air Handlers

INSTALLATION INSTRUCTIONS

R Series Cooling Manual

INSTALLATION INSTRUCTIONS

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

EL SERIES INSTALLATION INSTRUCTIONS

Installation Instructions Part No

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Installation Instructions

AC10B FEATURES UNIT DIMENSIONS. Ducane Air Conditioner. THE DIFFERENCE IS QUALITY

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

R Series Cooling Modules

Transcription:

18-AD32D1-3 Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit Upflow models: 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA 4PXCBU36BS3HAA 4PXCCU36BS3HAA 4PXCBU42BS3HAA 4PXCCU42BS3HAA 4PXCBU48BS3HAA 4PXCCU48BS3HAA 4PXCDU48BS3HAA 4PXCCU60BS3HAA 4PXCDU60BS3HAA Downflow models: 4PXCAD24BS3HDA 4PXCBD24BS3HDA 4PXCBD30BS3HDA 4PXCCD30BS3HDA 4PXCBD36BS3HDA 4PXCCD36BS3HDA 4PXCBD42BS3HDA 4PXCCD42BS3HDA 4PXCBD48BS3HDA 4PXCCD48BS3HDA 4PXCDD48BS3HDA 4PXCCD60BS3HDA 4PXCDD60BS3HDA ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. Table of Contents! WARNING WARNING (Medium/high pressure) Contains Refrigerant! System contains oil and refrigerant under high pressure. Recover refrigerant to relieve pressure before opening the system. See unit nameplate for refrigerant type. Do not use non-approved refrigerants, refrigerant substitutes, or refrigerant additives. Failure to follow proper procedures or the use of non-approved refrigerants, substitutes, or refrigerant additives could result in death, serious injury, or equipment damage. A. GENERAL These coils are designed for use in combination with a heat pump or cooling outdoor section using R-410A REFRIGER- ANT. The 4PXC equipment has been evaluated in accordance with the Code of Federal Regulations, Chapter XX, Part 3280 or the equivalent. Suitable for Mobile Home use The height of the Furnace, Coil and discharge duct work must be 7 ft. or less. Inspect the coil for shipping damage. Notify the transportation company immediately if the coil is damaged. B. APPLICATION INFORMATION 1. FURNACE AND COIL The coil MUST BE installed downstream (in the outlet air) of the furnace. 2. INDOOR UNIT AIRFLOW Indoor unit must provide the required airflow for the heat pump or cooling combinations approved for these coils. General... 1 Application Information... 1 Recommendation... 2 Furnace in Upflow Position... 2 Furnace in Downflow Position... 3 Maximum Airflow Setting, CFM... 3 Installing / Brazing Refrigerant Lines... 3 Leak Check... 4 Condensate Drain Piping... 4 Cleaning the Coil... 4 Outline Drawings... 5 Troubleshooting Indoor TXV / Cooling Mode... 8 Figure 1 IMPORTANT: Review your installation requirements. Check the table on the outline drawings and note all dimensions for your coil before beginning the installation. A341869P30

C. RECOMMENDATION If a coil is part of the total system installation, use the Installer s Guide packaged with the furnaces, outdoor sections, and thermostat for physically installing those components. IMPORTANT: - Upflow furnaces must be matched with dedicated upflow coils. - Downflow furnaces must be matched with dedicated downflow coils. - Horizontal Left furnaces must be matched with dedicated upflow coils and conversion kit. - Horizontal Right furnaces must be matched with dedicated downflow coils and conversion kit. IMPORTANT: If installing the coil in the horizontal position, you MUST use the horizontal kit listed below for this coil model number and follow the instructions in the installation guide provided with the conversion kit. Model Number 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA 4PXCAD24BS3HDA 4PXCBD24BS3HDA 4PXCBD30BS3HDA 4PXCCD30BS3HDA 4PXCBU36BS3HAA 4PXCCU36BS3HAA 4PXCBD36BS3HDA 4PXCCD36BS3HDA 4PXCBU42BS3HAA 4PXCCU42BS3HAA 4PXCBU48BS3HAA 4PXCCU48BS3HAA 4PXCDU48BS3HAA 4PXCBD42BS3HDA 4PXCCD42BS3HDA 4PXCBD48BS3HDA 4PXCCD48BS3HDA 4PXCDD48BS3HDA 4PXCCU60BS3HAA 4PXCDU60BS3HAA 4PXCCD60BS3HDA 4PXCDD60BS3HDA Horizontal Kit No. BAYCONV18A BAYCONV23A BAYCONV27A BAYCONV30A D. FURNACE IN UPFLOW POSITION - APPLICATION USES UPFLOW COIL MODEL ONLY! CAUTION Caution: This coil is pressurized with 8-12 psig of dry air. Do not stand directly in front of the coil connections when removing sealing plugs. If no pressure is released, check for leaks. 1. UPFLOW COIL CONVERSION (Models: 4PXCBU36BS3HAA, 4PXCCU36BS3HAA, 4PXCBU42BS3HAA, 4PXCCU42BS3HAA, 4PXCBU48BS3HAA, 4PXCCU48BS3HAA, 4PXCDU48BS3HAA, 4PXCCU60BS3HAA, 4PXCDU60BS3HAA only) a. For maximum efficiency, remove the factory installed two-piece baffle assembly from the apex of the coil by removing the 5/16 hex head screws. See Figure 2. b. Replace only the top baffle using the same screws previously removed. CASED COIL UPFLOW FURNACE Remove and Discard Figure 2 SCREWS (BOTH SIDES) Replace 2. UPFLOW GAS FURNACE a. Apply gasket material (duct seal field supplied) to ALL mating surfaces between the furnace and the coil case. b. Set the coil case on top of the furnace. Connect the ductwork to the coil case using field supplied screws. c. Secure the coil case to the furnace and seal for air leaks as required. SELF TAPPING SCREWS (4) 1-1/2 MAXIMUM FIELD SUPPLIED FOR UPFLOW / HORIZONTAL LEFT INSTALLATIONS Figure 3 Trane 2015 18-AD32D1-3

E. FURNACE IN DOWNFLOW POSITION- APPLICATION USES DOWNFLOW COIL MODEL ONLY 1. DOWNFLOW GAS FURNACE! CAUTION Caution: This coil is pressurized with 8-12 psig of dry air. Do not stand directly in front of the coil connections when removing sealing plugs. If no pressure is released, check for leaks. When a coil is used with a downflow furnace, a subbase is not required between the coil case and combustible flooring. a. Place the coil case on the furnace supply air plenum. b. Secure the coil case to the plenum. c. Set the furnace on top of the coil case, making sure that the back side of the discharge opening is snug up against the duct flange at the top rear of the coil case. d. Secure the coil case to the furnace and seal for air leaks as required. F. MAXIMUM AIRFLOW SETTING, CFM TE: Water blow-off could occur in certain installation positions if the airflow setting exceeds the maximum values listed. Maximum airflow setting, CFM Coil Upflow Horizontal Left 4PX*U24BS3HAA 900 800 4PX*U30BS3HAA 1125 1000 4PX*U36BS3HAA 1350 1200 4PX*U42BS3HAA 1575 1400 4PX*U48BS3HAA 1800 1600 4PX*U60BS3HAA 2250 2000 * May be "A", "B", "C", or "D" Maximum airflow setting, CFM Coil Downflow Horizontal Right 4PX*D24BS3HDA 750 900 4PX*D30BS3HDA 925 1125 4PX*D36BS3HDA 1100 1350 4PX*D42BS3HDA 1300 1575 4PX*D48BS3HDA 1475 1800 4PX*D60BS3HDA 1850 2250 * May be "A", "B", "C", or "D" G. INSTALLING / BRAZING REFRIGERANT LINES! CAUTION Do T open refrigerant valve at the outdoor unit until the refrigerant lines and coil have been brazed, evacuated, and leak checked. This would cause contamination of the refrigerant or possible discharge of refrigerant to the atmosphere. 1. The following steps are to be considered when installing the refrigerant lines: a. Determine the most practical way to run the lines. b. Consider types of bends to be made and space limitations. c. Route the tubing making all required bends and properly secure the tubing before making final connections. TE: Refrigerant lines must be isolated from the structure and the holes must be sealed weather tight after installation. IMPORTANT: Do not unseal refrigerant tubing until ready to fit refrigerant lines. There is only a holding charge of dry air in the indoor coil, therefore no loss of operating refrigerant charge occurs when the sealing plugs are removed. TE: TXV bulb MUST be protected (wrapped with wet rag) or removed, while brazing the tubing. Overheating of the sensing bulb will affect the functional characteristics and performance of the comfort coil. 1. Remove both rubber plugs from the indoor coil. 2. Field supplied tubing should be cut square, round and free of burrs at the connecting end. Clean the tubing to prevent contaminants from entering the system. 3. Run the refrigerant tubing into the stub tube sockets of the indoor unit coil. PAINTED AREAS OF THE UNIT MUST BE SHIELDED DURING BRAZING. 4. Flow a small amount of nitrogen through the tubing while brazing. 5. Use good brazing technique to make leakproof joints. 6. Minimize the use of sharp 90 degree bends. 7. Insulate the suction line and its fittings. 8. Do T allow un-insulated lines to come into contact with each other. TE: The TXV setting on this unit may run high superheat (15-25 F) by design when measured at the outdoor unit. 18-AD32D1-3 3

Bulb is seated squarely within the indention of the suction line J. CLEANING THE COIL The two piece door (3-piece on 24.5" wide models) allows removal of the outer casing doors without interference from refrigerant or condensate lines. Once the outer doors are removed the split inner coil panels can be easily removed. The inside and outside of the coil can be easily cleaned with a brush and vacuum with the panels removed. See Figure 5. The foil covered insulation on 4PXC coils should be wiped down and residual dirt and dust should be vacuumed up to maintain good air quality. See Figure 6. Figure 4 When replacing the bulb and hose clamp, the clamp should be "snug" but not "tight" - spec is to torque the hose clamp to 20+/-5in-lb. H. LEAK CHECK 1. Using a manifold gauge, connect an external supply of dry nitrogen to the gauge port on the liquid line. 2. Pressurize the connecting lines and indoor coil to 150 PSIG maximum. 3. Leak check brazed line connections using soap bubbles. Repair leaks (if any) after relieving pressure. 4. Evacuate and charge the system per the instructions packaged with the outdoor unit. Figure 5 I. CONDENSATE DRAIN PIPING Condensate drain connections are located in the drain pan at the bottom of the coil/enclosure assembly. The female threaded fitting protrudes outside of the enclosure for external connection. A field fabricated trap is not required for proper drainage due to the positive pressure of the furnace; however, it is recommended to prevent efficiency loss of conditioned air. 1. The drain hole in the drain pan must be cleared of all insulation. 2. Insulate the primary drain line to prevent sweating where dew point temperatures may be met. (Optional depending on climate and application needs) 3. Connect the secondary drain line to a separate drain line (no trap is needed in this line). Figure 6 4 18-AD32D1-3

Outline Drawing for Upflow models: 4PXCAU24BS3HAA, 4PXCBU24BS3HAA, 4PXCBU36BS3HAA, 4PXCCU36BS3HAA, 4PXCBU42BS3HAA, 4PXCCU42BS3HAA, 4PXCBU48BS3HAA, 4PXCCU48BS3HAA, 4PXCCU60BS3HAA, and Downflow models: 4PXCAD18BS3HDA, 4PXCBD18BS3HDA, 4PXCAD24BS3HDA, 4PXCBD24BS3HDA, 4PXCBD36BS3HDA, 4PXCCD36BS3HDA, 4PXCBD42BS3HDA, 4PXCCD42BS3HDA, 4PXCBD48BS3HDA, 4PXCCD48BS3HDA, 4PXCCD60BS3HDA MODEL 4PXCAU24BS3 4PXCAD24BS3 4PXCBU24BS3 4PXCBD24BS3 4PXCBU36BS3 4PXCBD36BS3 4PXCCU36BS3 4PXCCD36BS3 4PXCBU42BS3 4PXCBD42BS3 4PXCBU48BS3 4PXCBD48BS3 4PXCCU42BS3 4PXCCD42BS3 4PXCCU48BS3 4PXCCD48BS3 WEIGHT (LBS.) 39 42 54 56 61 64 73 REFRIGERANT CONTROL TXV (N-BLEED) 4PXCCU60BS3 4PXCCD60BS3 HEIGHT "A" (IN.) 17-1/2 17-1/2 22-1/2 22-1/2 26-7/8 26-7/8 30-3/4 OVERALL WIDTH "B" (IN.) 14-1/2 17-1/2 17-1/2 21 17-1/2 21 21 OPENING WIDTH "C" (IN.) 13-5/8 16-5/8 16-5/8 20-1/8 16-5/8 20-1/8 20-1/8 TOP OPENING "D" 12-3/4 15-3/4 15-3/4 19-1/4 15-3/4 19-1/4 19-1/4 GAS CONNECTION 3/4 3/4 7/8 7/8 7/8 7/8 7/8 LIQUID CONNECTION 3/8 3/8 3/8 3/8 3/8 3/8 3/8 MATCHED FURNACE WIDTH ( ADAPTER REQUIRED) 14-1/2 17-1/2 17-1/2 21 17-1/2 21 21 DRAIN PAN PLASTIC From Dwg. D345397 RevD 18-AD32D1-3 5

Outline Drawing for Upflow models: 4PXCBU30BS3HAA, 4PXCCU30BS3HAA, and Downflow models: 4PXCBD30BS3HDA, 4PXCCD30BS3HDA MODEL 4PXCBU30BS3 4PXCBD30BS3 4PXCCU30BS3 4PXCCD30BS3 WEIGHT (LBS.) 47 49 REFRIGERANT CONTROL TXV (N-BLEED) HEIGHT (IN.) 17-1/2 17-1/2 OVERALL WIDTH (IN.) 17-1/2 21 OPENING WIDTH (IN.) 16-5/8 20-1/8 TOP OPENING 15-3/4 19-1/4 GAS CONNECTION 3/4 3/4 LIQUID CONNECTION 3/8 3/8 MATCHED FURNACE WIDTH ( ADAPTER REQUIRED) 17-1/2 21 DRAIN PAN PLASTIC From Dwg. D345398 RevC 6 18-AD32D1-3

Outline Drawing for Upflow models: 4PXCDU48BS3HAA, 4PXCDU60BS3HAA, and Downflow models: 4PXCDD48BS3HDA, 4PXCDD60BS3HDA MODEL 4PXCDU48BS3 4PXCDD48BS3 4PXCDU60BS3 4PXCDD60BS3 WEIGHT (LBS.) 68 77 REFRIGERANT CONTROL TXV (N-BLEED) HEIGHT (IN.) 26-7/8 30-3/4 OVERALL WIDTH (IN.) 24-1/2 24-1/2 OPENING WIDTH (IN.) 26-7/8 30 TOP OPENING 22-3/4 22-3/4 GAS CONNECTION 7/8 7/8 LIQUID CONNECTION 3/8 3/8 MATCHED FURNACE WIDTH ( ADAPTER REQUIRED) 24-1/2 24-1/2 DRAIN PAN PLASTIC From Dwg. D345408 RevC 18-AD32D1-3 7

Before starting, insure the blower wheel, indoor and outdoor coils are clean. Troubleshooting Indoor TXV / Cooling Mode Is sub cooling at the outdoor unit between 8 to 12F? Is superheat < 5F? Is air flow at least 350 CFM per ton? Correct air flow problem Is superheat < 25F? TXV is OK Verify line set is sized properly for application Is the liquid line temperature at indoor coil within 8F of outdoor liquid line temperature? Is indoor temperature more than 85F? Remove sensing bulb from the suction line. Measure superheat at indoor coil while holding the bulb in bare hand for one minute. Does superheat decrease? Measure superheat at indoor coil while placing the bulb in an ice and water bath for one minute. Does superheat increase? The system is running at max capacity and this may be causing the High superheat. Wait until indoor temperature is less than 80F and check superheat again. Verify Inlet screen of inlet tube assembly is clear of debris Verify Inlet screen of inlet tube assembly is clear of debris Is sub cooling less than 8F? Confirm that charge is correct and look for dirty or restricted outdoor coil. Replace the TXV Confirm that charge is correct. Trane 6200 Troup Highway Tyler, TX 75707 For more information contact your local dealer (distributor) 10/15 Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.