Architectural and Engineering Specification for a Personal Alarm System System (PAS)

Similar documents
Architectural and Engineering Specification for a. Flash / Flare

Architectural and Engineering Specification for a Real-Time Locating System Flare

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

Fiber Optic Cable Fence Disturbance Sensor

Architectural and Engineering Specification for a Security Management System. StarNet 2

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

Taut Wire intrusion detection sensor (TWIDS)

Architectural and Engineering Specification for a Fiber Optic Pipeline Integrity Monitoring System. FiberPatrol FP7000

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Section PERIMETER SECURITY SYSTEMS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION NURSE CALL SYSTEM

Product Specifications

DESCRIPTION INSTALLATION

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

INSTALLATION INSTRUCTIONS TALKBACK MODULE

SECTION FIRE ALARM SYSTEMS

PALS 9000 Personal Alarm Locating System System Specifications

Buried ported coaxial cable outdoor intrusion detection system

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

Security Escort. boschsecurity.com. Reliable wireless location solutions

Product Specifications

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Hugs Product Guide Specification

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

Product Specification

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

LaserFOCUS VLF-250 Engineering Specification

TECHNICAL DATA SHEET. FreeSpace DS 16F 1 OF 8. Loudspeaker. Product Overview. Product Information. Key Features. Applications

SECTION INTRUSION DETECTION

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

ANNUNCIATOR FIXED MODULE

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Alarm annunciation, control and communication systems

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Staff Alert Panel. Installation Guide. Using the Touchpad Exit Controller B

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Conventional Releasing Control Panel

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

EOTec 2C32 Installation Guide

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

Open-area Smoke Imaging Detector. Engineering Specification

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

CRESTRON MEDIAMANAGER INTELLICLASS

Michigan State University Construction Standards COMMISSIONING OF FIRE ALARM SYSTEMS PAGE

TLS-300 UST Monitoring and Leak Detection System

Microphonic Cable Fence Disturbance Sensor (multiplex version)

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Interrogator 200 Audio Verification Module (AVM)

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

SensaGuard TM Integrated Latch Installation Instructions

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

SECTION FIRE ALARM

introduction Submittal Data Sheet CENTRA-GUARD POINT LEAK DETECTION

PALS ATLAS Personal Alarm Locating System. System Specifications

CERTIFICATION BULLETIN

PIP PCTPA001 Testing of Process Analyzer Systems

Installation and user guide

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

RAM3 Remote Alarm Module

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Proximity Detection & Collision Avoidance. Strata s solutions for surface, underground, and surface-to-underground

Solutions for Mass Notification Systems

IN2 Lighting Control Devices

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

Figure 1. Figure 2. See notes 1 and 2 below.

Tri-Tech Medical Inc.

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

LONE WORKER SAFETY HOW DO YOU PROTECT YOUR LONE WORKERS? EMPLOYEE CHECK-IN SYSTEMS DON T WORK! YOU NEED AN IMMEDIATE NOTIFICATION SYSTEM

STATEMENT OF WORK. Physical Protection Equipment Upgrades for Al-Tuwaitha Site in Iraq

Appendix 1 LACCD Districtwide Security Performance Requirements

Section K CHLORINATION EQUIPMENT

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

Transcription:

Architectural and Engineering Specification for a Personal Alarm System System (PAS) July 3, 2014 Page 1 of 10

This document is intended to provide performance specifications and operational requirements for the Senstar. It is written in a generic format. These specifications may be copied verbatim to form a generic procurement specification. Senstar and the Senstar logo are registered trademarks of Senstar Corporation. The information in this document is subject to change without notice. Senstar reserves the right to make changes to product design or manufacturing methods, as engineering progresses, or as other circumstances warrant. Copyright 2014. Senstar Corporation. All rights reserved. July 3, 2014 Page 2 of 10

PART 1 GENERAL 4 1.1 System Summary... 4 1.2 Submittals... 4 1.3 Spares... 4 1.4 Warranty... 4 1.5 References... 5 PART 2 PRODUCTS 6 2.1 Personal Alarm System... 6 2.2 Manufacturers... 6 2.3 Regulatory Requirements... 6 2.4 Manufacturing Quality Requirements... 6 2.5 Mechanical Requirements... 6 2.6 Electrical Requirements... 7 2.7 Environmental Requirements... 7 2.8 Transmission/Reception Requirements... 7 2.9 Performance Requirements... 8 2.10 Personal Protection Device Functionality... 8 2.11 Alarm Generation and Announcements... 8 2.12 Reliability and Maintenance Requirements... 8 PART 3 EXECUTION 10 3.1 Site Assessment... 10 3.2 System Installation... 10 3.1 System Calibration... 10 3.2 Training... 10 July 3, 2014 Page 3 of 10

PART 1 GENERAL 1.1 System Summary 1.2 Submittals 1.3 Spares 1.4 Warranty The contractor shall install a. The system shall be used to locate personnel under duress (e.g. corrections officers, administrative staff, nurses, counselors, etc). The system shall consist of a lightweight, wearable Personal Protection Device (PPD) that uses ultrasonic signals (40 khz) with receivers distributed throughout the building or complex. As ultrasonic signals do not penetrate walls or ceilings, the system shall be able to locate personnel on a per-room basis. A duress alarm shall be initiated by pressing a button on the PPD. Optionally, the PPD shall initiate a duress alarm when a pin is pulled out or when the PPD is tilted beyond a specific angle for a period of time (man-down feature). The system shall include a built-in microphone on each receiver so that operators can listen in or record the audio in the location in which the duress alarm occurred. Alarm, audio, and self-test outputs from the receivers shall be collected and relayed to the site's control room equipment. A. Contractor submittals to the facility owner shall include the following, as a minimum: 1. Site conditions report as per article 3.1 2. Configuration and test results for the system after installation and calibration are complete as per article 3.1 3. All manufacturer-supplied software required for the calibration and operation of the system. A. The contractor shall deliver to the facility owner spare system components. B. For each system component, spares consisting of least one unit or 10% of the number that comprise the system, whichever is greater, shall be provided. A. The product shall be under warranty for a minimum of two years from the date of purchase. B. The supplier shall make available replacement components, parts or assemblies for a minimum of 10 years from the date of purchase. July 3, 2014 Page 4 of 10

1.5 References Architectural and Engineering Specification: A. Abbreviations and acronyms: The following acronyms and abbreviations are used in this document: 1. AC: Alternating Current 2. DC: Direct Current 3. PAS: Personal Alarm System 4. PPD: Personal Protection Device July 3, 2014 Page 5 of 10

PART 2 PRODUCTS 2.1 Personal Alarm System A. The contractor shall supply a. B. The system shall consist of: 2.2 Manufacturers 1. A lightweight, wearable Personal Protection Device (PPD) that communicates over ultrasonic frequency with receivers distributed throughout the building or complex. 2. A device that consolidates the alarm, audio, and self-test events from the receivers and provides an interface to the site's control room equipment. A. The PAS from Senstar Corporation (www.senstar.com) meets the requirements stated in this document. 2.3 Regulatory Requirements A. The PAS shall be registered with a nationally registered testing laboratory such as CSA or UL, under the appropriate performance category for duress alarm equipment. B. All equipment shall carry the appropriate registration label(s). 2.4 Manufacturing Quality Requirements A. The manufacturer s quality management system shall be certified as conforming to ISO 9001:2008. 2.5 Mechanical Requirements A. PPDs: 1. The dimensions shall be equal to or less than 9.7 x 6.1 x 2.3 cm (3.8 x 2.4 x 0.9 inches). 2. The weight shall be equal to or less than 200 g (7 ounces) (including battery). 3. Durability: Other than for cosmetic damage, the PPDs shall not be damaged or malfunction after six drops onto a tiled floor from a height of 1.5 m (5 feet) with one drop on each of the six sides on three orthogonal axes. 4. The PPD enclosure shall have a tamper-resistant construction. 5. The PPD shall include an option for a belt-holster. 6. The PPD shall include a pendant option with a pull-ring. B. Ultrasonic receivers: 1. The receiver enclosures shall be installed in wall or ceiling receptacles and include a protective faceplate. July 3, 2014 Page 6 of 10

2. The receiver faceplate shall be affixed with tamper-resistant screws. 2.6 Electrical Requirements A. PPD: 1. The PPD shall use commercially available 9VDC non-rechargeable batteries. 2. Battery shall be replaceable by the user or system administrator. 3. The PPD shall automatically report a low battery condition via an audio notification. 4. Under normal operating conditions (3 test transmissions per day) the PPD battery shall provide a minimum life time of one year before a low battery condition is reported. 5. The PPD shall be capable of operating normally for at least 15 days following the reporting of a low battery condition. B. Ultrasonic receivers: 1. The input voltage for the receiver shall be 12 to 48 VDC and shall draw no greater than 40 ma. 2. The receivers shall have the option of being used with a heater unit. The input voltage for the heater unit shall be 12 to 24 VDC and draw no greater than 1A. 2.7 Environmental Requirements A. The PPD shall operate within specifications under the following environmental conditions: 1. Operating temperature: 20 C to +60 C ( 4 F to +140 F) 2. Water resistance: The PPD shall not malfunction after being exposed to 30 seconds of heavy rain. B. The ultrasonic receivers and other installed devices shall operate within specifications under the following environmental conditions: 1. Operating temperature: 0 C to +60 C (0 F to +140 F) 2. The ultrasonic receivers shall include a heater option. 2.8 Transmission/Reception Requirements A. The PAS shall communicate using ultrasonic signals. B. The ultrasonic signals shall be modulated to eliminate false alarms generated by other devices or objectives. C. The PPD, when activated, shall generate an omni-directional signal so that the device does not need to be pointed or directed at the nearest receiver. D. The receiver faceplate shall include a red LED that illuminates whenever an alarm is received. July 3, 2014 Page 7 of 10

2.9 Performance Requirements Architectural and Engineering Specification: A. The coverage range of each ultrasonic receiver shall be configurable but shall support a nominal diameter distance of 30 m (100 feet). 2.10 Personal Protection Device Functionality A. The PPD shall include a button that, when pressed, activates an alarm transmission B. Optionally, the PPD shall be capable of generating an alarm if the PPD is taken from the user. This tamper function shall require the use of an optional device, such as lanyard with a pull-pin, which causes an alarm to be generated when it is removed from the PPD. C. The PPD shall be available in a pendant configuration that activates an alarm transmission with a pull-ring. D. Man-down feature: 1. The PPD shall have an optional man-down capability, whereby the PPD automatically transmits a duress alarm when it tilts beyond a specific angle for a period of time. 2. The PPD shall emit a warning tone prior to generating the alarm from the mandown position. 2.11 Alarm Generation and Announcements A. Each person using the PAS shall wear a PPD. B. Each PPD user shall be capable of transmitting a duress alarm, which will be reported at the control center, using one or more of the following activation methods: 1. Pressing a button on the PPD. 2. Removing a pin attached to a lanyard from the PPD (optional) 3. Activation of the man-down function (optional) 4. Removing a pull ring (pendant model) C. The front panel of the ultrasonic receivers shall include an option (Local Annunciation Panel, or LAP) for visual and audio notifications of up to four zone alarms. 1. The LAP shall include push-bottoms for acknowledging each alarm (silencing the audio tone) and clearing the alarm. 2.12 Reliability and Maintenance Requirements A. MTBF: The system (excluding consumable items like batteries) shall be less than one failure per two years per 4,645 m 2 (50,000 square feet) of coverage. B. The PAS shall be able to test the state of all system hardware. The system shall be capable of reporting a diagnostic alarm upon the detection of a system problem. July 3, 2014 Page 8 of 10

C. The system shall be able to perform diagnostic checks on PPDs and ultrasonic receivers. July 3, 2014 Page 9 of 10

PART 3 EXECUTION 3.1 Site Assessment A. Before installation begins, the installation contractor shall provide a report to the facility s owner documenting any site conditions that may prevent the system from operating satisfactorily. 3.2 System Installation A. The system shall be installed in accordance with the manufacturer s recommended procedures as defined in the manufacturer s documentation for the system. 3.1 System Calibration 3.2 Training A. The installation contractor shall calibrate the system in accordance with the manufacturer s recommended procedures as defined in the manufacturer s Product Guide. B. The installation contractor shall submit to the Owner the calibration and configuration settings for each processor in the system. C. The installation contractor shall submit to the Owner a response plot for each zone in the system. A. The installation contractor or vendor shall train the Owner s maintenance personnel in the calibration and system maintenance procedures as given in the manufacturer s product documentation. July 3, 2014 Page 10 of 10