ARBOR SERIES WOOD WALLCOVERINGS

Similar documents
ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

Write Walls Dry Erase Specification Data (Section 09720)

WALLCOVERINGS WALLCOVERINGS

c. Oko-Tex (European environmental health standard)

SECTION PRESENTATION DRY ERASE WALLCOVERING

ARCHITECT S SPECIFICATIONS

SECTION (09950) - WALL COVERINGS

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

SECTION PRESENTATION DRY ERASE WALLCOVERING

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION PRESENTATION DRY ERASE WALLCOVERING

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

PART 1 GENERAL 1.01 SUMMARY

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

HP PVC-free Durable Wall Paper

EXAMPLE SPECIFICATION ONLY

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

PART 1 GENERAL 1.01 SUMMARY

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

Architectural Specification Sheet

ARCHITECTURAL SPECIFICATIONS

SECTION BRICK PAVERS. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION FIRE-RATED GLASS AND FRAME

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

DIVISION 10 SPECIALTIES

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ENGINEERING EVALUATION

SOLI VINYL. Type II. Photo: Wallcovering Soli ACW Tequila Sunrise #14

MICROVENTING AVAILABLE This product can be microvented with the Duravent process for breathability. You may specify this as an added feature.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION FIRE EXTINGUISHER CABINETS

16028 September 23, 2016

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Section Plaster Accessories

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

mason What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

SECTION CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Fire Performance of Translucent Systems

venetian plaster exclusivewallcovering Low VOC LEED IEQ 4.2 CAL 1350 & CHPS certified VINYL WALLCOVERING Fire classification

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Design Criteria. Installation

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

DESIGN & CONSTRUCTION GUIDELINES

SECTION ELECTRICAL SYSTEMS COMMISSIONING

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

SECTION AIR DUCT ACCESSORIES

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

Design & Construction Standards, Revised January

SECTION SECURITY TESTING AND COMMISSIONING

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

EcoAisle Thermal Containment System

SECTION GYPSUM PLASTER

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

D. Reference Standards (Utilize latest editions available):

Design & Construction Standards, Revised January

Product Guide North & South America

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

SECTION (15767) - UNIT HEATERS

NATURAL GAS PIPING

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

security resources international PART I: GENERAL eguardian Series 1.01 SUMMARY 1.02 REFERENCES 1.03 SUBMITTALS 1.04 QUALITY ASSURANCE

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

SECTION FAN COIL UNITS

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

CP1-C5 COMPACTOR SPECS 2009

The Series LFII (TY3596) Residential

FIRE SUPPRESSION SPRINKLER SYSTEM

A. This Section includes the following emergency plumbing fixtures:

Transcription:

PART 1 - GENERAL 1.01 SUMMARY ARBOR SERIES WOOD WALLCOVERINGS A. A. Provide wood wallcovering, complete. B. B. Related Sections 1. 1. Section 09 74 00 Wall Finishes 2. 2. Section 09 74 13 Wood Wallcovering 3. 3. Section 09 74 16 Flexible Wood Veneers 1.02 REFERENCES A. A. United States Testing Company, Inc. 1. Testing performed " in accordance with the specification set forth in ASTM E84.98. "Standard Test Method for Surface Burning Characteristics of Building Materials," both as to equipment and test procedures. Test procedure is similar to UL-723, ANSI No. 2.5, NFPA No. 255 and UBC in UBC1994 & 1997 UBC. 1.03 SUBMITTALS A. Submit a sample of each type of wood wallcovering specified, inclusive of product name, wood species and cut and/or figure labeled on the back of each sample. B. 6 X 9 samples will be submitted C. C. Submit a copy of maintenance instructions to Owner in accordance with Division 1 section "Contract Closeout." 1.04 1.04 QUALITY ASSURANCE A. A. Manufacturer: Provide each type of wood wallcovering required produced by one manufacturer whose published literature clearly indicated compliance of wood wallcovering with specified requirements. B. B. Applicator: Installation by skilled commercial wallcovering applicators with no less than three years of documented experience installing wallcovering of the types and extent specified for the project. C. C. Composition:

1. 1. A five-ply wood wallcovering consisting of genuine wood veneer, bonded to paper, foil, glue line barrier, and paper. 2. 2. Factory applied protective coating to ensure quality and help maintain the integrity of the wood veneer wallcovering. D. Fire Hazard Classification: Provide materials that comply with Class A Fire Rating when tested in accordance with ASTM E84-98. 3. 3. Flame Spread: 10 4. 4. Smoke Developed: 25 E. Field Test Panels: Contractor shall install not less than three (3) full-width sheets of each pattern specified in an area designated by the architect and or designer. The test installation area shall be reviewed for conformance to manufacture s standard installation instructions recommended adhesive. The approved test area shall remain as part of the finished installation work as a standard of comparison for the installation throughout the project 1.05 PRODUCT DELIVERY, STORAGE AND HANDLING A. Deliver all wood wallcovering to the job site in the distributor's undamaged packaging clearly labeled and properly identified. B. Store materials in a clean, dry, protected area where temperature and humidity remain stable and within the ranges specified by the distributor. 1.06 PROJECT CONDITIONS A. Maintain a constant temperature range of 65 F - 85 F degrees, with less than 50% relative humidity, for at least 4 days prior to, throughout the installation period and maintained consistently thereafter. B. B. Provide Gypsum board finish in compliance AWCI Specification, Level 4. C. C. Finish plaster walls to the distributor's specification and free from undulations and surface defects.

D. D. Metal surfaces to be clean, dry and smooth with a rust inhibitor applied. Refer to wood wallcovering product installations instructions for details. E. Lighting: Sufficient lighting will be provided by the contractor during the installation process. If required, temporary lighting will be provided to augment insufficient or low level permanent lighting. 1.07 1.07 WARRANTY A Submit distributor s 1 year written warranty against defects in material and workmanship. RJF International Corporation guarantees and warrants Arbor Series Flexible Wood Wallcovering to be free from defects in material and workmanship for a period of one year. RFJ International Corporation s liability is limited to replacement of goods found by RJF International Corporation to be defective. This warranty is in lieu of all other warranties or guarantees expressed or implied, including warranties or guarantees of merchantability and fitness for a particular use. 1.08 1.08 MAINTENANCE A. Treat Arbor Series Flexible Wood Wallcovering using a lint-free cloth and Murphy's Oil Soap to clean. Repeat this procedure once a year using Murphy's recommended instructions. PART 2 PRODUCTS 2.01 DISTRIBUTOR A. A. Wood Wallcoverings: Arbor Series Flexible Wood Veneer Wallcovering, distributed by RJF International Corporation, Fairlawn, Ohio. Contact sales representative.

2.02 MATERIALS A. A. Wallcovering: Arbor Series Flexible Wood Veneer Wallcovering (Note to specifier: Fill in applicable areas.) 1. 1. Species: Select from: White Maple, Sapele, etc. 2. 2. Cut and figure: Select from: Flat Cut, Quarter Cut, Rift Cut, Rotary Cut 3. Matching: Select from: Book Match, Slip Match, Swing Match 4: Sheet Size: 2.03 ACCESSORIES A. A. Adhesive: Roman Decorating Products: Extra Stength Pro- 732, Clay Strippable Pro- 774; Gardner-Gibson Products: Dynamite 111 Heavy Duty Clay (formerly known as Sur-Stik 111), Dynamite 433 Heavy Duty Clay Strippable B. B. Primers may or may not be used depending upon the wall and environmental conditions. Consult the distributor's installation instructions. PART 3 EXECUTION 3.01 EXAMINATION

A. A. Examine substrates and installation conditions. B. Test substrates with suitable moisture meter and verify that moisture content does not exceed 7%. C. C. Verify that substrate surfaces are clean, dry, smooth, structurally sound and free from surface defects and imperfections that would show through the finished surface. D. D. Notify the contractor and architect in writing of any conditions detrimental to the proper and timely completion of the installation. E. Do not proceed with work until conditions have been corrected. NO OIL BASED PRIMER IS TO BE USED WITH ARBOR SERIES FLEXIBLE WOOD WALLCOVERING. 3.02 INSTALLATION A. Install flexible wood wall coverings in strict accordance with manufacturer s written installation instructions. B. B. After the application of three sheets of wood wallcovering, request inspection by Architect/Designer for material quality and proper installation. C. C. If problems occur, stop the installation and contact the local flexible wood wallcovering representative before proceeding. D. Install each sheet in sequential, numerical order, as printed on the back of each sheet. E. Install as delivered from the factory with the standard urethane finish applied by the manufacturer. F. If additional protection is required, apply 1-2 coats of a low to mild sheen polyurethane finish. G. Specific stains selected by the architect to be applied over Arbor Series Wood Wallcoverings must have 1-2 coats of polyurethane applied. Samples must be submitted by contractor to architect or designer for approval. Follow the distributor's staining and finishing instructions.

3.03 CLEAN-UP COMPLETION A. Upon completion of the work, remove excess materials, debris and rubbish resulting from the installation and leave the area in a clean and orderly condition. B. Protect the finished wood wallcovering from damage that may occur from other trades until project has been completed.