Cold Plate for Super Computer

Similar documents
The Way We Were and Are Going on Cooling High Power Processors in the Industries

RIGID DC LIQUID CHILLER

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Thermal Performance of a Loop Thermosyphon

Heat sinks for electronic cooling applications

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.


Thermal management architectures for rack based electronics systems. Sukhvinder Kang, David Miller Aavid Thermalloy, Concord NH, USA

"SAN ACE MC" for Pentium *

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

International Journal of Engineering Science Invention Research & Development; Vol. V, Issue VI, DECEMBER E-ISSN:

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Environmental Chambers

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Compact design & easy maintenance

VariCool VAV Engineering Guide

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Economically Productive Universal applicable

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Midea VFD Centrifugal Chiller Technology

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Efficient thermal management for batteries 3 rd International Conference Thermal Management for EV/HEV 25. June 2013

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

DVU-HP. Integrated Reversible Heat Pump System

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Development of the Micro Capillary Pumped Loop for Electronic Cooling

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

SKYPAK II Heating & Cooling Self Contained Packages

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

High Heat COP. High/Low Stage

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Modular Adsorption Dryers

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

Sensors for Cell Phones

15. Heat Pipes in Electronics (1)

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

50TM TFF COMBINATION HEATING/COOLING UNITS

Advantages / Characteristics

Magnetic Refrigeration. Study Case

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

portable gas analyser

50TM COMBINATION HEATING/COOLING UNITS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

commercial refrigeration products

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Bench-Top Type Temperature (& Humidity) Chamber

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Wearable cooling system to manage heat in protective clothing

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Summary of Research Activities. Eckhard A. Groll Professor of Mechanical Engineering

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Reduce everything but reliability

SKYPAK II, 3 Ton Series, gives you a

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Ultimate energy saving technology

Impact of TXV and Compressor in the Stability of a High-End Computer Refrigeration System

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

portable gas analyser

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

CLEAN-LASERSYSTEME GMBH

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

SKYPAK II, 3 Ton Series, gives you a

Method to test HVAC equipment at part load conditions

Indirect Evaporative Air Conditioning

gas monitoring system

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

CLIMATE CONTROL PRODUCT GUIDE

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

Development of a Compact High Efficiency Cooling Device for the PA8000 Processor*

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Transcription:

Liquid Cooling 1

Cold Plate for Super Computer Thermal Resistance (C/W) Calculation Speed:12 x 10 12 times /sec. SB:12 boards Cold Plate IOSB : 6 boards Thermal Resistance Super computer CPU 20kW/Rack x 848 racks 17MW/ a machine SB:12 boards R=dT/Q=(Tbase-Twi)/Q 0.06 0.05 specification :<0.05C/W 0.04 0.03 Measured data 0.02 0.01 0 20 40 60 80 100 120 Heat Input Q (W) 2

Liquid Cooling Cold Plate Brazed Cold Plate (Cross Section) Brazed Sample Inspection by Ultrasonic Microscope 3

Cold Plate Assembly Cold Plate (8 pcs) Coupler Coupler Manifold Φ6.35 tube 4

Cold Plate assembly on the Motherboard For super computer Φ6.35mm Copper Tube 80W(60-100W) x 8 CPUs/Board One tough Coupler to tube Manifold Total 32 memory on the board 5

Cold Plate and Heat Pipe Cooler for a Super Computer Heat Pipe Heat Spreader for DIMM Hub Cold Plate Qcm Cold Plate 6

DIMM (Dual Inline Memory Module) Cooling Cooling method of DIMM : Liquid cooling + Heat spreader Cold Rail Cold Rail Heat spreader Plate(DMS1) with Heat pipe 7

Mini Channel Cold Plate Assemblies: Different Types 8

Modular Refrigerator 9

Fujikura MRU Development Prototype # 1 (Proof of Design) Prototype # 2 (Compact and high performance) Compressor Evaporator/ Heater Expansion Valve Condenser + Blower Can fit into 19 inch rack 10

Fujikura Modular Refrigeration Unit Condenser To Evaporator Compressor Cold Plate (Evaporator) Cover On Cover Total cooling solution designed & development by Fujikura Group using in-house technology Evaporator made by FETL with advanced cold Plate manufacturing technology. Heat pipe application inside MRU unit to improve COP. SUS flexible tube piping made by Fujikura-Numazu. Assembled & inspected by Fujikura Compo Sakura with high reliability. Cover Off Target system price: ~ 5000 USD 11

00:00:00 00:00:35 00:01:10 00:01:45 00:02:20 00:02:55 00:03:30 00:04:05 00:04:40 00:05:15 00:05:50 00:06:25 00:07:00 00:07:35 00:08:10 00:08:45 00:09:20 00:09:55 00:10:30 00:11:05 00:11:40 00:12:15 00:12:50 00:13:25 00:14:00 00:14:35 00:15:10 00:15:45 00:16:20 00:16:55 00:17:30 00:18:05 00:18:40 00:19:15 00:19:50 Temperature, C Temp (C) Fujikura MRU: Test Results Temparature-Time Evaporator temperature controlled at around 25 26 C Heater Input 1.8 kw 60 50 40 30 20 10 0 Refrigerator ON Heater ON Evaporator Evaporator-Outlet Evaporator-Inlet Time, mm:ss 12

Evaporative Heat Transfer Coefficient Technology comparison: Evaporator Heat Transfer Coefficient 50 k Evaporative heat transfer coefficient range for each technology is dependent on: Evaporator design & thickness Operation orientation Heat flux Heat transfer length Two dimensional heat flow Two phase passive cooling Heat spreading device Highly developed evaporator Two phase passive cooling High heat flux and long distance capability 40 k Single phase cooling Pumped circulation One dimensional heat flow Two phase passive cooling 30 k 20 k 15 35 k 20 50 k 10 k 5 10 k 8 15 k 10 20 k Liquid Pumped Cooling Thin Heat Pipes Cylindrical Heat Pipes Thermal Control Technology Vapour Chambers Loop Heat Pipes 13

Heat Spreader 14

15 Heat Spreader of Chips A heat spreader is important part to be spreading heat and guard for silicon chips. Cold forged Electro Ni plating Gold plating CPU Package IHS with Ni plating and gold plating Stiffener

Micro-channel Vapor chamber 16 Thermal Resistance of Micro Channel Vapor Chamber Micro skiving fin is available 0.1mm fin gap and 0.1 mm fin thickness.

Piezo Fan 17

Piezo Fan (Dual Cool Jet): Heat Dissipating Element Thin, Robust, Simple Structure 18

Features of DCJ Thin DC fan for note-pc Miniaturization of fan bearing has limitation on the size due to reliability. 3mm thick is required at this moment. High rotation speed is needed when reducing the thickness, and it becomes a high noise and high power consumption. Failure is caused from dust. Ultra thin DCJ 1mm thickness is possible. Low acoustic noise (<35dBA). Low power consumption (<350mW). Simple structure. 19

Static pressure [Pa] Sample of DCJ (40SQ) Size (main body: W x L x T) 40x40x1 [mm] P-Q Performance(40SQ-25D-1T) Size with frame (Wo x Lo) Input Voltage Driving Voltage* 60x50 [mm] DC 5 [V] AC 25 [Vrms] 8.0 7.0 6.0 Driving Frequency* 155 ±2[Hz] 5.0 Max. Air Flow Rate* Max. Static Pressure* 15 [LPM] 6 [Pa] 4.0 3.0 2.0 1.0 Fan Off 0.0 0 5 10 15 20 Air flow [L/min] Fan On 20

Heater Temperature ( ºC) Reference DCJ Testing Data for 5W Cooling 100 DCJ running at 125 HZ and 35 Vrms 90 80 70 60 50 40 30 DCJ on DCJ off 20 10 0 0 1 2 3 4 5 6 Power Input (W) With DCJ cooling, CPU power can be increased up to 5 W Tested only one DCJ without any other thermal cooling parts 21

4: EXPERIMENTAL STUDY _ Fabricated Module Specification Heat Pipe : L 175.0mm W 8.5mm T 1.5mm Module Weight : 20gmm (Including Fan) Maximum Height : 4.5mm Total Resistance Qmax 18W Temperature Profile Th Target Line Current module Qmax is 18W 電子電装事業部門開発発表会, 27 th December,2012 22

Direct Methanol Fuel Cell (DMFC) 23

Energy Density of Selected Fuels Energy Sources Volumetric Energy Density (Watt*hours/Liter) Specific Energy Density (Watt*hours/kg) Li-ion Batteries 450 200 Hydrogen + Container Compr (2000 psi) 520 248 Hydrogen/Metal Hydride 600 236 Methanol* 4,817 6,098 Formic Acid 2,050 1,724 *Methanol has the highest energy density. 24

Technical highlight - Passive water balance operation e - Water MeOH H 2 O Air O 2 Methanol CO 2 vent (1) (2) (3) (1) Methanol permeable membrane (2) DMFC MEA (3) Air and water management layer Water Balance Operation: Water is produced at the cathode. About 1/3 generated water is reused at anode for electrochemical reaction. About 2/3 generated water is released from the system. 25

Direct Methanol Fuel Cell (DMFC) DMFC is investigated based on our thermal and liquid feeding technology. Strong point - Unique fuel delivering system - Pocket size - High energy conversion efficiency using exhaust heat (1kW type) 2W output prototype 1kW output prototype Output power [W] 2 1,000 Size [mm] 135 x 75 x 23 400 x 500 x 150 Supplying water temperature [ o C] Applications - 50 Portable electronics device (Smart phone, mobile PC) Aviation, Passenger ship, etc. 26

2W DMFC Fuel tank Stack DC-DC converter Package Internal structure 1. Sequencing fuel bottle to charge fuel into the DMFC stack 2. Connecting DMFC to the portable electronic device. 3. DMFC will automatically start to charge the electronic device. 1. H L t : 75 140 38 mm 2. Weight without fuel : 230g (With fuel : 260g) 3. Power output : 4-5W h for 1 fuel pushing. 4. Working time: up to 8 hours (Automatically stop) 5. Orientation independent 6. Working temperature : 10 35 o C (0-40 o C in future). 7. Ambient relative humidity : 10 100% 27

Performance & Durability of passive DMFC system P ow er output (W ) 1.2 1.0 25 o C and 50%RH C #1 C #120 0.8 0.6 0.4 0.2 Working time: 6 hours with one fuel charging. Total power output: C#1 (4.60W h); C#120(4.55W h). Fuel utilization: 1.4 W h/g of fuel. 0 60 120 180 240 300 360 T im e (m ins) We tested this DMFC charger in last 6 months for total 120 operation cycles. 28

1KW DMFC 300mm 400mm 600 mm Overall Dimensions: 600mm (W) x 400mm (D) x 330mm (H) 29

1KW DMFC Air blower Methanol sensor Liquid pump Heat exchanger Liquid pump stack Water tank Methanol solution tank 30

Performance of large active area single cell (180cm 2 ) Voltage (V) 8.00E-01 7.00E-01 6.00E-01 5.00E-01 4.00E-01 3.00E-01 2.00E-01 1.00E-01 Power output, 75C, 1.75% MeOH at 0.4ml/A, dry air 0.00E+00-2.00E+00 0.00E+001.00E+012.00E+013.00E+014.00E+015.00E+016.00E+017.00E+01 Current (A) The peak power output is 16.5W. 1.80E+01 1.60E+01 1.40E+01 1.20E+01 1.00E+01 8.00E+00 6.00E+00 4.00E+00 2.00E+00 0.00E+00 Assume 61 cells in one stack, the stack power output is 1,000W. In order to increase the stack power output to 1,200W, 20% up of performance is needed. Our target is to increase single cell power output 20 to 25W. Power (W) E_Stack[V]-0710 E_Stack[V]-0625 Power[W]-0710 Power[W]-0625 31

Energy balance diagram of 1.0 kw DMFC 5.3 kw of 4.0 kw of heat methanol 1.3 kw of total electrical power 1.0 kw of net electrical power 150 W for air blower 150 W for the other active components 32

Thanks 33