Condensate Pump. Installation and Safety Instructions CP-16 CP

Similar documents
Condensate Pump. Installation and Safety Instructions CP-NL20 CP-NL20-230

Instruction Manual. Cheese Warmer with Pump

SSS Intrepid 16 FMS. Manual

GULPER 16SV 16 GALLON WET/DRY VACUUM WITH FRONT MOUNT SQUEEGEE

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Part No Revised November / Instruction Manual Model #8150 AND #8151

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

Professional Warming Drawer and Warming Drawer Cabinet

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

SSS BPV- 40 Backpack Vacuum

Comfort Series Instant Hot Water System

Superdryer Dehumidifiers

Instruction Manual. Carmel Apple-Dip Warmer

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Lubi Submersible Condensate Removal Pumps

Instruction Manual. Double Candy Apple Cooker

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Bag-In-A-Box Oil Pump System

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

Large Combo Warmer Instruction Manual Model #2206

VENTILATION FAN WITH LIGHT AND HEATER

WET/DRY VACUUM MODEL SV-12

MN908 No. 282C Replaces 282B LB7013

Portion Bag Cheese Warmer

Service Parts, Kits and Accessories

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

XC Portable Air Conditioning

5300, 5300CH, 5300EX, 5300FN

Installation & Maintenance Instructions

Instruction Manual. Bucket Oil Pump

... a. Electric Baseboard Heaters IN THIS SECTION J b t S. SY-STEl\t1S, I~C_

Air Pump Up to 800 gallons

Chargebuster Ion Gun Installation, Operation and Maintenance

Cincinnati, OH USA

Instruction Manual. Nacho Cheese Dispenser and Warmer

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Cincinnati, OH USA

IW-25-2 Dehumidifier Installation & Operations. Manual

FOR EASY, FAST INSTALLATION AND FOR RESULTS

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

48 MaxxAir Portable Evaporative Cooler Owner s Manual

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

THE MW-1 Cyclone RECORD CLEANING MACHINE

DROP IN POPCORN WARMERS

InstructIon Manual KrEs EQuIPMEnt stands

FLCH4R Garage and Utility Electric Heater

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

User Guide AutoSealer 1001

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

VENTILATION FAN / LED LIGHT

HUMIDITY SENSING BATH FAN

- Oscillating Table Model Fan

CANISTER VACUUM MODEL SC-19

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

H-16.5 Record Cleaning Machine Setup and Instruction Manual

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

MODEL CDB8 INSTALLATION INSTRUCTIONS

Wax Base Heater & Dispenser

M Series Fan Filter Units

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

Garment Steamer Model SC620

Clean Steam Generators

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Instruction Manual. Table Top Steamer Cart

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

Instruction Manual. Part No Revised September 2004

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

Xaact Spot. Xaact Hot Spot

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Quest PowerHeat HFC 100 Pro

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Chargebuster Ion Gun Installation, Operation and Maintenance

Cat 5 Pro Vacuum OPERATOR S MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Owner s. Coolerr. comply. To view

Transcription:

Condensate Pump Installation and Safety Instructions CP-16 CP-16-230

CP-16 CP-16-230 Rated Voltage 120 Volts / 60 Hz 220 Volts / 60 Hz (208-230) Rated Current Draw 1.9 Amps 1.0 Amps Input Type USA 3-prong plug NEMA 6-15 plug Head Height 16 ft. maximum 16 ft. maximum Flow Rate at Zero Head 1.2 GPM 1.2 GPM Temperature Rating Continuous duty 140F Max inlet temperature 160F Not suitable for contact with steam or gasses that exceed 160F Continuous duty 140F Max inlet temperature 160F Not suitable for contact with steam or gasses that exceed 160F Product Dimensions (LxWxH) 4.5 x 10.75 x 6.5 4.5 x 10.75 x 6.5 Product Weight 3.8 lbs. 3.8 lbs. Inlet Height from Base 3.5 3.5 Included Accessories Instruction Sheet Hang Tabs Plug Protector 4 Remote Shutoff Leads Inlet Cover Instruction Sheet Hang Tabs Plug Protector 4 Remote Shutoff Leads with Insulated Terminals Inlet Covers (3) Wiring Color References Black - Live/Hot White - Neutral Green - Ground All installations must conform to NEC requirements Brown - Live/Hot Blue - Neutral Green/Yellow - Ground All installations must conform to NEC requirements

Limited Warranty All pumps manufactured by or for DiversiTech Corporation (the Company) and sold by the Company under the DiversiTech brand are warranted to be free of defects in workmanship and materials for a period of 24 months from date of sale from the distributor to the contractor. The Company will credit, repair or replace, at its option, any Pump if deemed defective within this time period. All products returned to the Company must include a return authorization issued by the Company. The returned product should be suitably packaged and shipped prepaid from the point of shipment to the point designated in the Company's return authorization. This warranty is a limited warranty and shall be in lieu of any other warranties, expressed or implied, including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose. There are no other warranties that extend beyond the description of the face hereof. The liability of the Company arising out of it's supply of said products, or their use shall not in any case exceed the cost of correcting defects in the products as set forth above. The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in which the products have been assembled. In no event shall the company be liable for loss of profits, indirect, consequential, or incidental damages. SAFETY WARNING FOLLOW ALL SAFETY INFORMATION TO REDUCE POTENTIAL ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. PUMP MUST BE PROPERLY GROUNDED. NEVER USE THE PUMP TO MOVE FLAMMABLE LIQUIDS. NEVER USE THE PUMP IN AN EXPLOSIVE GAS ENVIRONMENT, OR WHERE GAS FUMES OR VAPOR MAY BE PRESENT. ALWAYS DISCONNECT THE POWER PRIOR TO MOVING, ADJUSTING OR SERVICING THE PUMP OR ATTACHED SYSTEMS. WARNING: RISK OF ELECTRIC SHOCK THIS PUMP MUST BE PROPERLY CONNECTED TO POWER FOLLOWING THE NATIONAL ELECTRIC CODE (NEC). FAILURE TO FOLLOW THESE WARNINGS WILL VOID WARRANTY AN COULD RESULT IN AFATAL ELECTRIC SHOCK. A GREEN LED WILL INDICATE IF POWER IS AVAILABLE. THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUND- ING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE. 2016 DiversiTech Corporation PRINTED IN VIETNAM Diversitech Corporation 6650 Sugarloaf Parkway Suite 100 Duluth,GA 30097 800.995.2222 FAX 770.593.8600

General Information Thank you for the purchase of this DiversiTech condensate pump. This pump is designed to automatically remove the condensate water that collects from appliances such as air conditioners, high-efficiency furnaces and de-humidifiers. The pump has a built-in tank that collects the water from the appliance. When the water collected reaches sufficient level inside the pump tank, the pump switches on and pumps the water to a remote location for disposal. When the tank is sufficiently empty the pump automatically switches off. The pump is capable of lifting water to its rated height and is equipped with a check valve that prevents water from flowing back into the tank when the pump shuts off. The pump is also equipped with a switch that activates when the water in the tank reaches an overflow condition. The overflow safety switch may be connected to turn off the appliance if the high water condition occurs. Pump should be stored indoors. The chosen location should be clean and dry. Unpacking CHECK FOR SHIPMENT DAMAGE Carefully open the carton to avoid damage to the pump. Do not use a knife or other sharp object that may scratch the pump s cover. After opening the carton, look for damage. If damage is found file a claim with the freight carrier. Power Source Connect power cord to a supply voltage and frequency that matches what is shown on the pump nameplate. Source voltages lower than the rated supply can reduce performance and cause the pump to overheat. Pump Installation The pump must be level and should be placed on a solid surface or floor. The pump has rubber feet to reduce noise and keep it in place during operation. Do not use this pump in the presence of spraying or standing water, it may cause a shock. This pump is not suitable for use in Class I or Class II locations (explosive gas or dust). Do not cover the pump air vents. The pump is air cooled. Do not cover the vent holes located on the top or sides of the pump housing. The pump may be operated continuously as long as the air vents are not covered. Mounting The condensate pump is equipped with optional mounting tabs which allow the tank to be screwed to a wall or equipment side panel. The screw-toscrew distance is 10-1/16. When mounting into drywall or concrete walls the screws must have anchors which provide the necessary support in the wall material.

Inlets 4 inlet holes are located in the top deck of the pump. Flexible vinyl tubing or PVC may be connected to any of the pump inlets. Knock out covers are provided to cover unused inlets. Be sure to knock out only the hole used for the inlet pipe to prevent the pump from collecting debris or insects. Tubing installed into the inlet holes must be straight. The tubing must not bend inward where it will interfere with the pump or float mechanism. When using rigid tubing such as PVC, be sure to cut the end at an angle. This will allow the condensate water to drain freely and keep the tubing end from being blocked by the tank bottom. It may be desirable to use a P or U trap between the AC unit and the condensate pump to provide a liquid barrier to air flow from the air conditioner. These types of traps always contain some water which blocks the flow of air from the AC unit which is wasteful and can cause other problems such as accelerated algae growth. Outlets and Tubing Connections The pump is equipped with a combination barb-type fitting and check valve. The fitting allows the connection of 3/8 flexible vinyl tubing such as DiversiTech CVT clear vinyl. Attach the tubing by pressing it over the barb fitting and secure with a screw type hose clamp. Route the tubing up and away from the pump; avoid compressing or kinking the tubing. The tube route should be the shortest possible distance from the pump to the building exterior or other drain location. For best results the distance that the water must go UP should be shorter than the distance that it goes DOWN. With the longer DOWN tubing, the length will help siphon the condensate from the tank, speeding the pump out time. Pump Electrical Connections Connect the pump power to a properly grounded outlet capable of providing power that exceeds the requirements listed on the pump nameplate. Avoid the use of extension cords wherever possible. The pump must be operated by a continuous source of power and must not be connected to switched outlets or other power supplies that may be inadvertently or automatically turned off. All aspects of the installation must conform to requirements of the NEC, and any applicable local codes. Safety Switch The pump safety switch should be used on 24V Class II control circuits only. The pump safety switch connections are to be connected in series with the 24 Volt thermostat circuit to shut off A/C systems should an overflow condition occur. An optional DiversiTech Universal Alarm may be connected to indicate system trouble.

Pump Operation Apply power by plugging in the pump. Test float and safety switch by manually filling the tank. Test Safety Switch operation (if used) to be sure that the A/C system shuts down when the pump has reached an overflow condition. Leak Check: Operate the pump by filling tank to trigger operation. Pump Maintenance and Disassembly Always disconnect power before performing maintenance. Periodically inspect the Pump tank to assure it is free of accumulated dirt or sludge. Do not use solvent cleaners. Clean Tank with soap and warm water only. The check valve may be removed for cleaning or replacement by unscrewing with a 9/16 wrench. (illustration) Clean inlet and outlet piping. Tubing may be cleared of slime or debris instantly with a Wagner brand Gallo Gun tool and Swoosh cartridges. Reassemble system and check for correct operation. DOC32302