Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

Similar documents
Hoffman Specialty Pump Products

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER S USE. Condensate Return Systems General Installation, Operation, & Service Instructions !

INSTRUCTION MANUAL DN0136 REVISION D

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

DESCRIPTION AND INSTALLATION

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

FLANGE-MOUNT CENTRIFUGAL PUMPS

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

Condensate Boiler Feed Water Make-Up

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

569, 570, 571, 572 Series

Domestic Pump Condensate Transfer Equipment

569, 570, 571, 572 Series

SECTION STEAM CONDENSATE PUMPS

INSTRUCTION MANUAL HS-229G

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

REPAIR PART DIAGRAMS. Pages: 1-6

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

PARTS MANUAL. American Dish Service. ADS HIGH TEMP SINGLE RACK DISHMACHINE MODELS: HT-25 5 WIRE 110 Volt Control System

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

5. CONDENSATE PUMPS/UNITS

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-66 L-R/R-L EFFECTIVE: MAY, 2014

SPEAKMAN SPEAKMAN SPECIFICATIONS

MARLOW PUMPS RECIRCULATION

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

PARTS MANUAL. American Dish Service ADS LOW-WATER DISHWASHER MODELS: L3DW / L3DWC EFFECTIVE: MAY, 2008

568X, 587X, 588X Series

DOOR AND PANEL PARTS For Models: DU1300XTVB0, DU1300XTVQ0, DU1300XTVT0, DU1300XTVS0 (Black) (White) (Biscuit) (Stainless)

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Series 1140 and 1141 Temperature Regulators

LC Series - Light Commercial Pump Station Installation and Operation Manual

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Encyclon Inc. Cyclonic Filtration Systems

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

! WARNING. Before using product, read and understand instructions.

INSTRUCTION MANUAL A REVISION A. Series e 3-4/e 3-6 Instant Hot Water Recirculating Systems

EFFECTIVE: MAY, American Dish Service ADS MODEL: ASQ GLASSWASHER PARTS MANUAL. 900 Blake Street Edwardsville, Kansas (913) /08

sta-rite Call C and CC Series Installation/Operation/Parts For further operating, installation, or maintenance assistance:

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Illus. Part No. No. DESCRIPTION

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

DOOR AND PANEL PARTS. For Models: KUDS25SHBL1, KUDS25SHWH1, KUDS25SHAL1, KUDS25SHBT1 (Black) (White) (Almond) (BISCUIT)

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Water Piping and Pumps

HORIZONTAL AGITATOR ASSEMBLY

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

FIREPLACE INSTALLATION

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

OWNERS GUIDE TO INSTALLATION AND OPERATION

NOTE: Parts are no longer available for this tool. The manual will continue on the next page.

DUPLEX CONDENSATE TANK SYSTEM

IMAGE V. Parts and Service Manual

SECTION STEAM CONDENSATE PUMPS

PARTS MANUAL. American Dish Service MODEL: 5-AG-S ADS LOW TEMPERATURE DISHWASHER EFFECTIVE: JULY, 2013 C 4/08

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

INSTALLATION INSTRUCTIONS

Threaded. Flanged. Model PSH. Primary Secondary Header A-451

DOOR AND PANEL PARTS For Models: KUDU02VRSS1, KUDU02VRMT1 (Stainless) (Meteorite)

DOOR AND PANEL PARTS For Models: KUDC10FXBL1, KUDC10FXWH1, KUDC10FXSS1 (Black) (White) (Stainless)

VANGUARD 245 POST-MIX DISPENSER

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

WU701 BLOWER/AIR INLET & WATER LEVEL FLOAT

Single-Control Lavatory Faucet

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Item No. Name of Part Material of Construction 1 * 2 11 * * 65

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

SECTION STEAM CONDENSATE PUMPS

Wallis & Stevens 7C. hand operated sprayer for cold bitumen emulsion. Contact: Sales at BX Plant on or

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Installation, Operation, and Maintenance Manual. NRF -25,36,45/NBF -25,36, and 45 Circulator

MODEL SK2750. COMPRESSOR SERVICE KIT For use on 2750 Series Compressors

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

HERZ Regulating valve 4002

MODEL CMA-180UC PARTS MANUAL Rev 1.16

COS-101 NON SELF FLUSHING COMBI REPLACEMENT PARTS LIST

INTERMEDIATE GUIDE BRACKET

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Transcription:

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN06C

PARTS LIST DN06 Index How To Use This Parts List.............................. Identifying Your Watchman Unit..........................- Pump Parts for B Style Pump............................8 Pump Parts for A Style Pump............................8 Float Switches & Mechanical Alternators.....................9 Receivers, Conduit Assemblies & Misc. Parts................0

PARTS LIST DN06 Identifying Your Watchman Unit Due to the fact that the Watchman unit is a factory stocked product, unique serial numbers have not been applied to the product. It is therefore necessary to identify the specific generation of product by the physical characteristics of the pump and of the receiver. Figure on the following page indicates two types of piping arrangements that have been used for the Watchman. You ll note the Packing Construction and A Style Watchman indicates a discharge pipe that is parallel to the receiver face (a 90 degree discharge from the pump suction). The B Style is piped perpendicular to the receiver face (a 80 degree or in-line discharge from the pump suction). This only applies to the A design receiver configuration. Figure shows cut-away drawings of all three generations of pumps used on the Watchman. The uniquely identifiable characteristics of each generation is the discharge orientation and the number of capscrews used to hold the volute to the motor (or motor bracket). By using these two easily identifiable characteristics, and referring to the following chart, it is possible to identify the style of pump on the unit. Suction to Discharge Orientation No. of Capscrews Packed Pump 90 A Style 90 B Style 80 Figure indicates the parts required to adapt the current B Style pump and motor assembly to replace the older design A Style pump. Note that the adapter piping is about /" wider than the A Style pump and motor discharge position. This can be taken up by use of a short nipple and/or a union in place of the existing discharge piping.

PARTS LIST DN06 FIGURE VENT VENT MAIN RETURN FROM HEATING SYSTEM HOFFMAN STRAINER VENT OVERFLOW LOOP FILL MAIN RETURN FROM HEATING SYSTEM HOFFMAN STRAINER VENT OVERFLOW LOOP FILL OVERFLOW TO DRAIN BY-PASS TO DRAIN BY-PASS TO DRAIN GATE-VALVE CHECK VALVE GATE-VALVE PLUG COCK OVERFLOW TO DRAIN CHECK VALVE PLUG COCK WC PACKED AND A STYLE WC B STYLE FIGURE 0 0 6 9 6 9 8 6 8 PACKED PUMP A STYLE B STYLE FIGURE Piping Conversion B To A Style Location Items Required To Adjust Piping () /" 90 Street Elbow () /" X " Nipple () /" 90 Elbow () /" X /" Nipple () /" 90 Elbow VOLUTE DISCHARGE /6 / /6 /"

PARTS LIST DN06 PRIMARY INLET 6 / MIN. GREENFIELD CONDUIT ALTERNATE BASKET STRAINER LOCATION OPTIONAL BASKET STRAINER SHIPPED LOOSE (ALTERNATE MOUNTING SHOWN) /8 /8 WATCHMAN PUMP / / / NPT DRAIN FLOAT SWITCH /" NPT DISCHARGE 6 & 9 GALLON B STYLE PUMP / B DESIGN RECEIVER PRIMARY INLET ALTERNATE BASKET STRAINER LOCATION 6 / MIN. OPTIONAL BASKET STRAINER SHIPPED LOOSE (ALTERNATE MOUNTING SHOWN) GREENFIELD CONDUIT THIS PUMP DUPLEX UNIT ONLY / NPT DISCHARGE /8 / /8 /8 /8 / NPT DRAIN WATCHMAN PUMP MECHANICAL ALTERNATOR (DUPLEX) FLOAT SWITCH (SIMPLEX) GALLON B STYLE PUMP / B DESIGN RECEIVER / NPT VENT NPT INLET / PUMP FLOAT SWITCH / / NPT OVERFLOW /8 8 /8" 6 /6" /" NPT DISCHARGE 6 /6 /8 / / 0 DRAIN 6 GALLON B STYLE PUMP / A DESIGN RECEIVER / A DUPLEX H SINGLE H / G NPT INLET / NPT VENT / NPT OVERFLOW FLOAT SWITCH OR MECHANICAL ALTERNATOR /8 M PUMP NO. (DUPLEX ONLY) PUMP NO. B D E / NPT DISCHARGE C DRAIN /8 /8 / /8 F 9 & GALLON B STYLE PUMP / A DESIGN RECEIVER 6 EDR STYLE REC. CAP A B C D E F G H M 8,000 Single 9 / /8 8 /8 9 /8 9 / / 0 /,000 Single 6 /8 /8 9 / 0 / 9 /8 / / /6,000 Duplex 6 /8 /8 9 / 0 / 9 /8 / / /8

PARTS LIST DN06 /" 0 /6" " VENT " INLET FLOAT SWITCH " OVERFLOW VENT /" MAX. 6 /6" DRAIN DISCHARGE /" 6 GALLON A STYLE PUMP / A DESIGN RECEIVER /8" 0 /" /" /" /" NPT VENT FLOAT SWITCH /8" 9" /8" " NPT INLET /" NPT DISCHARGE /8" /6" 8 /6" /" NPT OVERFLOW /8" /6" " /8" 6 /6" /8" /8" " DRAIN 9 & GALLON A STYLE PUMP / A DESIGN RECEIVER SQUARE RECEIVER DIMENSIONS FEET CAPACITY EDR STYLE GALLON A B C 8,000 Single 9 9 8 /8 8,000 Duplex /8 9 /,000 Single 9 /8 9 /,000 Duplex 9 /8 9 /

PARTS LIST DN06 6 9 6 0 9 8 8 AFTER 00 98-00 PUMPS MANUFACTURED PUMPS BETWEEN 98 MANUFACTURED TO 00 AFTER 00 ITEM NUMBER PART PART NUMBER DESCRIPTION REQUIRED NUMBER NUMBER Motor / hp, ph, 00 rpm DM000 DM000 Seal Holder DP090 DP966 Seal Impeller DP0 DP0 Head Gasket DG009 DG009 6 Pump Case with Wearing Ring DP66 DP66 Capscrew DJ008 DJ008 8 Wear Ring DP08 DP08 9 Pipe Plug /" P900 P900 0 Wire Spacer DP09 Water Slinger DP088 DP088 Seal Kit including Mechanical Seal, Head Gasket & Case to 800 800 Receiver Gasket Complete Pump and Motor Assembly 8000 8000 Order Replacement Parts by Description and Part No. Specify Serial No. shown on nameplate. 8

PARTS LIST DN06 WATCHMAN A STYLE PUMP AND MOTOR ASSEMBLY 0 6 9 8 6 ITEM NUMBER PART NUMBER DESCRIPTION REQUIRED NUMBER - Motor with Pump Head 8006 Water Slinger DP088 Pump Head DP006 Head Gasket DG0 8 Impeller DP0 9 Case Wearing Ring DP08 9-0 Pump Case with Wearing Ring DP60 6 Head to Case Capscrews DJ00 Case to Receiver Gasket DG0060 Seal Kit including Mechanical * Seal, Head Gasket & Case to 800 Receiver Gasket Complete Pump and Motor Assembly 80060 Order Replacement Parts by Description and Part No. Specify Serial No. shown on nameplate. * Seal only. Consult factory. Factory recommended spare parts. 9

PARTS LIST DN06 CONTINUED FLOAT SWITCH ASSEMBLY INSTRUCTIONS APPLICATION For automatically controlling the liquid level in a closed tank by float movement. MOUNTING Screw-in Tank Float Switches are mounted directly to the tank by means of the /" I.P.S. threaded fitting (D). Before screwing this fitting into the tank, loosen Nut (C) so that the fitting (D) is free to rotate in the switch bracket. Tighten the fitting (D) so that there will be no leak past the threads. Then revolve the switch case until it is horizontal and tighten Nut (C). REVERSE ACTION To change, relocate operating link to the opposite slot in base plate and corresponding hole in adjusting plate. ADJUSTMENT Switches are shipped from the factory set for a specified float travel. Reasonable adjustment of float travel can be made in the field by moving adjusting strips () which are held in place by Screws (A) and (B). Loosening Screw (B) and moving upper adjusting strip () will affect the upper limit of float travel only. Loosening Screw (A) and moving lower adjusting strip () will affect the lower limit of float travel. B A CAUTION: Switches are shipped with a bracket attached to the mounting plate. This bracket prevents the float and the rod from moving in the tank during shipment. When installing the system, this clearly marked shipping bracket must be removed and discarded. ITEM NUMBER PART NUMBER DESCRIPTION REQUIRED NUMBER Complete Float Switch with Foat NEMA DA09 Float DA06 * Float Switch Seal Kit 8009 C D MECHANICAL ALTERNATOR ASSEMBLY INSTRUCTIONS APPLICATION Mechanical alternators serve to open and close an electric circuit by an upward and downward float movement. The forces are applied by means of a float operating between different liquid levels. The action is such that two switch units are alternated on successive cycles. If the liquid level continues to rise or fall with one pump in operation, the lever will continue to travel to a further position at which point the second switch will be operated, throwing the stand-by pump across the line. MOUNTING Mechanical alternators are mounted directly to the tank by means of the /" I.P.S. threaded fitting (D). Before screwing this fitting into the tank, loosen Nut (C) so that the fitting (D) is free to rotate in the switch bracket. Tighten the fitting (D) so that there will be no leak past the threads. Then revolve the switch case until it is horizontal and tighten Nut (C). STANDARD OPERATION Contacts are arranged for sump action. In this form the contacts will close on increase in liquid level. REVERSE ACTION To change, relocate operating link to the opposite slot in base plate and corresponding hole in adjusting plate. ADJUSTMENT Switches are shipped from the factory set for a specified float travel. Reasonable adjustment of float travel can be made in the field by moving adjusting strips () which B A are held in place by Screws (A) and (B). Loosening Screw (B) and moving upper adjusting strip () will affect the upper limit of float travel only. Loosening Screw (A) and moving lower adjusting strip () will affect the lower limit of float travel. CAUTION: Switches are shipped with a bracket attached to the mounting plate. This bracket prevents the float and the rod from moving in the tank during shipment. When installing the system, this clearly marked shipping bracket must be removed and discarded. ITEM NUMBER PART NUMBER DESCRIPTION REQUIRED NUMBER Complete Mech. Altr. with Foat NEMA DA06 Float DA06 * Float Switch Seal Kit 8009 C D 0

Pump and Motor Asembly 800 Description Part Number Quantity Motor DM00 Impeller DP06 Pump Head/Motor Bracket DP008 Wearing Ring DP08 Impeller Capscrew DJ0 Impeller Washer DJ06 Capscrews DJ0066 8 Water Slinger DP088 Seal and Gasket Kit 800 Xylem Inc. 800 N. Austin Avenue Morton Grove, Illinois 600 Phone: (8) 966-00 Fax: (8) 96-89 www.bellgossett.com Bell & Gossett is a trademark of Xylem Inc. or one of its subsidiaries. 0 Xylem Inc. DN06C February 0