Incremental Comfort Conditioners

Similar documents
McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant

Catalog Daikin Type K. Incremental Room Conditioner. Engineered for flexibility and performance

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Catalog EnerSaver Packaged Terminal Air Conditioners and Heat Pumps

McQuay Type J Series Incremental Conditioner

Packaged Terminal Air Conditioner (PTAC)

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

E Z S E R I E S " W X 16" H

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Catalog Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat

Product Specifications. Vertical Floor Consoles By First Co.

PTAC 2017 Air Conditioner Collection

Packaged Terminal Air Conditioner (PTAC)

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

SeasonMaker ThinLine Fan-coil Units

SKYPAK II, 3 Ton Series, gives you a

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SeasonMaker ThinLine Fan-coil Units

SKYPAK II Heating & Cooling Self Contained Packages

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Specifications and Performance

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

Engineered for flexibility and performance

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

SKYPAK II, 3 Ton Series, gives you a

Catalog 1304 Packaged Terminal Air Conditioner with Top-Mounted Hydronic Heat Model PGAN - Unit Sizes

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

Applied Packaged Terminal Air Conditioner and Heat Pumps

EMI ENGINEERING SUBMITTAL

Q-TEC QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Applied Packaged Terminal Air Conditioner

Commercial High-Efficiency Condensing Units

Specifications and Performance

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Applied Packaged Terminal Air Conditioner and Heat Pumps

NEW 2011 DESIGN AIR CONDITIONERS

built-in comfort GE built-in air conditioners New product introductions January 2010

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

MAC-120HE-03 Air-Cooled Chiller

EMI ENGINEERING SUBMITTAL

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

50TM COMBINATION HEATING/COOLING UNITS

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

Q-Tec TM QC-Series Chilled Water Air Conditioner

PACKAGED TERMINAL AIR CONDITIONERS

Single Package Vertical Air Conditioners. Vert-I-Pak

CRSO SERIES CEAFO SERIES

Concealed Ducted Split Series R-407C MBH

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Engineered for flexibility and performance

Specifications and Performance S2H

Cabinet Unit Heaters Type CHF & CHB

SECTION ROTARY-SCREW WATER CHILLERS

PTW 42 Series 230/208 VOLT

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

ZoneAire. Packaged Terminal Air Conditioners PRODUCT PROFILE PRODUCT PROFILE. Features THE EXPERTS IN ROOM AIR CONDITIONING

PAJ3. Product Specifications

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Cabinet Unit Heaters Steam / Hot Water

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Transcription:

Style, comfort and energy efficiency...one room at a time. Incremental Comfort Conditioners Model PDNS Top-mounted Hydronic Heat Engineered for flexibility and performance

PDNS Incremental Comfort Conditioners Quality and Comfort You Can Trust Flexible, Low Cost, Energy Efficient, Reliable, Durable and Quiet Flexible size, capacity and voltage selections to match the requirements of your application. Heavy-gauge construction resists dents, scratches and corrosion over decades of use and promotes quieter operation. High efficiency heating and cooling chassis, fans, and motors provide reliable comfort control and maximize energy savings. Meets ASHRAE 90.1 efficiency Temperature limiting and night setback to maximize energy savings. ARI certified performance. UL listed and MEA agency approval. Continuous condensate removal and filtration of return air promotes good indoor air quality. Optional brick stops and/or support legs for brick or panel / curtain wall applications. A wide variety of factory-supplied options that can reduce field labor and installation costs. Low maintenance design. Optional digital touch-pad control provides an exact comfort setting and conserves energy. Built-in alarm codes make unit diagnostics easy. In 1958, we introduced the Incremental system the first through-the-wall, self-contained heating and air conditioning system and set the standard for reliable, efficient comfort control in multistory building applications. With hundreds of thousands of installed units, McQuay has earned its reputation as one of the most trusted names in individually-zoned comfort control. As one of the world s largest heating, ventilation and air-conditioning manufacturers, McQuay stands behind its products with the strength of a global organization. And with local McQuay representation and manufacturing facility in Auburn, New York, we can provide you the hands-on support you need to make your building project a success. 2 McQuay Incremental comfort conditioners are manufactured to institutional quality standards at our ISO 9002 certified manufacturing facility. Strict attention to manufacturing details from raw materials to the unit packaging gives you a quality product, delivered on-time to support your construction schedule. Every unit is UL Listed and MEA agency approved, with ARI certified performance that meets ASHRAE 90.1 efficiency The high design standards and heavy-duty construction of McQuay Incremental comfort conditioners can provide you years of reliable service, quieter operation and low operating costs. In fact, many of our comfort conditioners have been operating for more than 30 years. 3

Features and Benefits Time and Money Saving Wall Sleeve Options 1 Heavy-Duty Grille Two-way adjustment allows air to be directed where it is needed. Option for extruded aluminum grille. 2 Heating Chassis Top-mounted hydronic (steam or hot water) heat for easy installation. 1 2 7 6 Wall Sleeve Heavy-gauge steel with powder paint coating for maximum scratch, dent and corrosion resistance. Custom wall sleeve depths available. Options for brick or panel/curtain wall applications. 7 Outside Air Louver Heavy-duty, architectural, extruded aluminum to resist weathering. Option for recessed louver. Panel/brick flange (optional) 5 8 6 8 Cooling Chassis Energy efficient, quiet and reliable rotary compressor. 3 Permanent Cleanable Filters (not shown) Filter all return air to promote good indoor air quality. Easy to access and maintain. Adjustable support/leveling legs (optional) Standard Wall Sleeve 3 Room Cabinet Heavy-gauge steel with powder paint coating for maximum scratch and dent resistance. Removable for easy access to filters, controls and piping for routine maintenance and service. Option for custom cabinet colors. Custom depth for varying wall thicknesses. Available in front or bottom return configurations. 4 Kick plate Adjustable height and custom colors for varying floor treatments. 4 5 Electro-Mechanical or Digital Touch-pad Control Reliable and easy to read and operate. Continuous or cycle indoor fan operation. Automatic room freeze protection. 5 Digital Touch-pad Control Wireless Remote (Option) Automatic Motorized Outside Air Damper (not shown) Opens when unit is operating to bring in outside air for improved indoor air quality. Closes when unit is idle to prevent cold drafts. Manual switch to select damper CLOSED or AUTO Operation. Separate Indoor and Outdoor Fans (not shown) Two fan motors provide lower operating costs and quieter operation. Provide more flexible options for architectural louvers or special condenser air treatments. Custom depths Drip edge Pitched bottom Wall Sleeve with Recessed Louver Design 4 5

Performance Data Dimensional Data UNIT SIZE 007 1,2 009 1 012 1,2 015 1 016 1 VOLTS 115V 208V 265V 115V 208V 265V 115V 208V 265V 208V 265V 208V Btuh 8,000 9,700 12,100 15,000 16,000 EER 10.8 10.4 10.0 10.2 9.3 COOLING Full Load Amps 8.2 3.9 3.4 10.0 5.0 4.4 13.3 6.4 5.4 8.0 6.7 9.4 Watts 750 750 750 930 930 930 1,175 1,175 1,175 1,521 1,521 1,810 Power Factor (%) 88 89 79 76 77 78 98 88 82 99 86 90 AIRFLOW High Cool 195/60 185/60 300/70 295/70 295/70 CFM Low Cool 180/40 175/40 275/50 270/50 270/50 TOTAL/ High Heat 205/60 205/60 330/70 340/70 340/70 VENT Low Heat 190/40 190/40 305/50 315/50 315/50 HEATING Full Load Amps.80.43.43.80.43.30 1.67.82.60.82.60.82 HYDRONIC Hot Water High/Low 16,300/13,855 16,300/13,855 18,400/15,640 18,400/15,640 18,400/15,640 HEATING BTUH 3 Steam High/Low 20,100/17,085 20,100/17,085 22,400/19,040 22,400/19,040 22,400/19,040 MINIMUM CIRCUIT AMPACITY 9.5 4.7 4.0 12.8 6.9 5.1 16.1 8.3 6.7 10.5 8.2 12.1 DELAY FUSE OR CIRCUIT BRKR 4 15 15 15 15 15 15 15 15 15 15 15 15 RECEPTACLE REQUIRED, NEMA No. 5-20R 6-20R - 5-20R 6-20R - 5-20R 6-20R - 6-20R - 6-20R TOTAL SHIPPING WEIGHT (LBS) 284 288 292 296 296 ROUGH WALL OPENING 16 x 42 1 Based on ASHRAE and ARI test conditions of 95 F DB/75 F WB outside, 80 F DB/67 F WB inside. 2 Cooling performance ratings based on low fan speed. 3 Based on 200 F EWT; 20 F T 70 F EAT; 2 psig steam 70 F EAT 4 Type HACR circuit breaker. Note: 265V unit requires subbase. Wall Sleeve Dimensions Top View WALL SLEEVE/ROOM CABINET SELECTION CHART A B C D ROOM Standard Recessed Louver Wall Thickness CABINET Wall Sleeve Wall Sleeve 18-3/4 13-3/4" 15" 4-3/4" to 5-3/4" 17-3/4" 13-3/4" 15" 5-3/4" to 6-3/4" 16-3/4" 13-3/4" 15" 6-3/4" to 7-3/4" 15-3/4" 13-3/4" 15" 7-3/4" to 8-3/4" 14-3/4" 13-3/4" 15" 8-3/4" to 9-3/4" 13-3/4" 13-3/4" 15" 9-3/4" to 10-3/4" 12-3/4" 13-3/4" 15" 10-3/4" to 11-3/4" 11-3/4" 13-3/4" 15" 11-3/4" to 12-3/4" 10-3/4" 13-3/4" 15" 12-3/4" to 13-3/4" 10-3/4" 14-3/4" 16" 13-3/4" to 14-3/4" 10-3/4" 15-3/4" 17" 14-3/4" to 15-3/4" 10-3/4" 16-3/4" 18" 15-3/4" to 16-3/4" 10-3/4" 17-3/4" 19" 16-3/4" to 17-3/4" Standard Size Wall Sleeve Notes: 1. Wall opening shall be a minimum of 16-1/4" high X 42-1/4" wide and must be a minimum of 4" above the finished floor, including carpet for bottom return units. 2. Masonry support must be left in wall sleeve until mortar has thoroughly dried. 3. The weather panel is provided with a separate shipment of cabinet/wall sleeve. This panel provides a weather seal prior to installation of the chassis. Be sure to remove weather panel before installing chassis. 4. Wall sleeve should be installed level side-to-side, and inside-to-outside. 5. Wall sleeve must extend past inside finished wall 1-5/8" plus or minus 1/2". 6. Standard kickplate is adjustable from 3" minimum to 5" maximum. Custom heights are available. Model Nomenclature P DNS 2 007 A Z 62 12 Product Category P= PTAC Product Identifier DNS = A/C w/top-mnt Hyd Heat (Flat-top) DNC = A/C w/top-mnt Hyd Heat & Corrosion Protection Design Series 1 = A Design 2 = B Design Electromechanical Controls Solid State Control 12 = Unit Mounted 55 = Unit Mtd. MCO 13 = 24-Volt Thermostat Setup 56 = Hand Held Remote Infra-Red 21 = Unit Mtd. MCO, HFLO 57 = Wall Mtd. Remote T stat 24 = Unit Mtd. MCO w/nsb 26 = Unit Mtd. MCO w/grc & NSB Heating Option 62 = Normally Open - HW 63 = Normally Closed - Steam Coil Options Z = None Front View Architectural Louver Nominal Capacity 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 016 = 16,000 6 Voltage A= 115/60/1 C= 208/60/1 J=265-277/60/1 S= 208/60/1 with 115/60/1 standby emergency power Note: Electrical rough-in should be located behind kickplate (removable front) and below wall sleeve. 7 ASHRAE 90.1 Compliant Made In U.S.A.

Engineering Guide Specifications Furnish and install where shown on plans packaged terminal air conditioners of the sizes and capacities shown on the schedule. The units shall be located as shown on the drawings and shall include cabinet/wall sleeve, chassis, outdoor louver, hydronic heat section, valve, and room cabinet. All units shall be U.L. listed for safety and ARI certified for performance. Overall dimensions for the basic unit shall not exceed 52" wide, 22-1/2" high, and 17-3/4" deep. Overall dimensions of the wall sleeve shall be 16" high, 42" wide and (13-3/4"/ ) deep. All units shall operate on volts, 60 Hz, 1 phase power. The minimum energy efficiency ratio in Btu per hour per watt for each unit must be in accordance with ASHRAE 90.1 for each size. A global leader in system solutions for air conditioning, heating, ventilating and refrigeration. (800) 432-1342 www.mcquay.com Heating/Cooling Chassis Chassis shall be slide-in, plug-in type with a self-contained, hermetically sealed refrigerant circuit. All chassis sheet metal parts shall be constructed of heavy-gauge galvanized steel for maximum corrosion resistance. The chassis shall consist of the following components: Vibration isolated compressor; rifled copper tubed evaporator and condenser coils with high efficiency aluminum plate fins mechanically expanded to the tubes for maximum heat transfer; and a capillary restrictor type refrigerant metering device. Coils shall be factory tested at 300 psig. Airflow system shall consist of a separate single speed, totally enclosed, fan cooled, PSC outdoor condenser motor. Condenser fan shall be made of high impact resistant polymer and shall be propeller type with a slinger ring. Indoor fan motor shall be two speed and shall be separate from the outdoor condenser fan motor. Single motor units serving both condenser and evaporator sections are not acceptable. The indoor fan motor must be positioned on the indoor side of the bulkhead so as to be completely within the conditioned, filtered airstream. Both the indoor and outdoor fan motors shall be permanently lubricated type for prolonged life. Indoor fans shall be forwardly curved centrifugal type to provide even airflow across the evaporator coil. Heating Coil Heating assembly shall consist of pre-assembled cradle and heating coil that snaps directly on to the wall sleeve. Attaching the heating coil by screws or other methods is not acceptable. Coils are copper tubes and mechanically expanded into aluminum fins. Coil assemblies are to ship with a protective sheet metal cover to prevent damage during installation and construction. Sheet metal cover is to be removed prior to installation of the cabinet. Coils to be supplied in right-hand or left-hand piping configuration as required. During The Cooling Cycle The compressor, the outdoor fan motor and the indoor fan motor shall be energized. Condensation accumulated on the evaporator coil shall be drained into the outdoor section where it is to be picked up by the condenser fan slinger ring and evaporated against the outdoor coil. During The Heating Cycle (Hydronic Heat) Only the indoor fan motor, the (normally open) (normally closed) valve and automatic fresh air damper shall be energized. Outdoor condenser fan motor and compressor shall not be energized. Control Module: Electro-Mechanical Shall have a six (6) button selector switch containing Off-Heat-Cool-High- Low-Fan and a self-contained, adjustable thermostat with a field adjustable temperature limiting device. A fan cycle shall be incorporated to allow constant fan operation or intermittent fan operation. Intermittent fan operation shall allow the fan to energize upon a demand for heating or cooling. Digital Control Shall have solid state digital control operated via a unit mounted touch-pad, handheld infra-red or remote wall mounted thermostat. Shall include space temperature control and unit ON or OFF, and the following: Cooling Compressor and Outdoor fan, Indoor fan HI, LOW, CONSTANT or FAN CYCLE, Outdoor air damper. Heating Hydronic Valve, Indoor fan HI, LOW, CONSTANT or FAN CYCLE, Outdoor air damper. Room Cabinet Shall be flat top, wrap-around design with a heavy-gauge sheet metal front panel that is phosphatized and coated with a baked on, corrosion resistant finish. Room cabinets with ordinary enamel finish are not acceptable. Discharge grilles shall be tamper-proof. The control access door shall be mounted on the right-hand side. (Access door shall be furnished with a keylock device to prevent unauthorized tampering.) Fresh Air Damper A positive closing automatic fresh air damper must be located within the chassis to provide fresh air during fan operation. It will have a manual switch for AUTO operation or CLOSED. Filtration Shall be accomplished using a permanent, aluminum mesh, cleanable filter. Washable foam type filters are not acceptable. Filters must be concealed but easily accessible for scheduled maintenance. Wall Sleeve Shall be entirely constructed of galvanized, phosphatized, heavy-gauge steel with an Antique Ivory powder paint corrosion resistant finish. Unpainted, galvanized steel wall sleeves with or without rust inhibiting spray are not acceptable. Wall sleeves with ordinary enamel finish are not acceptable. Wall sleeves shall be installed through the wall as shown on plans and shall have factory provisions for use of appropriate fastening devices to secure sleeve to the wall. In no event shall fasteners be installed through the basepan in the bottom of the cabinet/wall sleeve. Outside Air Louvers Shall be (stamped) (architectural) anodized aluminum as shown on plans. Louver shall be (finished natural) (painted) as shown on the schedule. Louvers shall be easily installed from the inside of the building after the cabinet/wall sleeve has been installed. Special field fabricated louvers must be approved by the PTAC manufacturer as to free area and air circulation 2005 McQuay International A/SP 31-166 (5/05)