Troubleshooting Manual

Similar documents
DCU 305 R2/R3. Troubleshooting Manual

Manual# User s Manual

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

User s Manual DCU 305 R3 DCU 305 R3 LT. Diesel Engine Control Unit. Auto-Maskin

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

M2500 Engine Controller Installation Manual

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

SC-F3G User Manual 1.0

MO n : 12JMC rév A

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

CTT8 TEMPERATURE MONITOR DEVICE

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

Touchpad Exit Controller Administration Guide

EasyTronic III MANUAL SERVICE

PTE0705 Electric Fence Monitor

21-light Remote Annunciator. Owner s Manual

SCAN200E USER S MANUAL

Ontech GSM 9040/50. Reference Manual English -1 -

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

T7100D Microelectronic Conventional Thermostat

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Halton SAFE / 7.14 user guide and installation instructions

compact office 24V compact office 24V Lux

MTRA-FSP Level Control Relay. Installation & Operation Manual

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

OPERATION / INSTALLATION

compact office 24V compact office 24V Lux

SAFETY INFORMATION AND WARNINGS

SAFESMART Backup Controller SAFE-FSP. Installation & Operation Manual

DIAGNOSTIC GUIDE DIAGNOSTIC TEST DISPLAY FAULT/ERROR CODES IMPORTANT. Activating the Diagnostic Test Mode. Before servicing, check the following:

MD12-2 Vehicle Loop Detector

Magnum Internet Version. user manual P/N Martin Professional A/S

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Operating Instructions

Versa-Pak DMX. DMX 512 Dimmer. User Manual Revision 1, August , Electronics Diversified, Inc.

Memcom Emergency Telephone

RPM1600 Series Room Pressure Monitors

20 Light Remote Annunciator

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

ECO N DATE DESCRIPTION OF CHANGE CHG

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Installation, Operating and Maintenance Manual

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

DIAGNOSTIC GUIDE DISPLAY FAULT/ERROR CODES E1 THERMISTOR OPEN IMPORTANT. Activating the Diagnostic Test Mode. Test Mode Functionality

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

MD12-1 Vehicle Loop Detector

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

MODEL 4200-IR-2 (Up to 2 Sensors) MODEL 4200-IR-4 (Up to 4 Sensors) MODEL 4200-IR-6 (Up to 6 Sensors)

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

MODEL B2 INSTALLATION MANUAL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

M2000 Engine Controller

TrueAlarm Analog Sensing

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Hot Surface Ignition (HSI) System Booklet

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

UNC100 Integra Manual

PERMACONN PM1030 Includes DI300. Installation Manual

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

T7200D,E Series 2000 Commercial Microelectronic Thermostats

WC Series Vended Washers Troubleshooting, and Fault Codes

REPEATER FS5200R INSTRUCTION MANUAL

MPT Electric Fire Pump Controller

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

HP50HA ABG Heat Pump

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

EA-MINI / EA-MINI-V. LEITRONIC AG Swiss Security Systems

Operating Instructions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

PowerRouter application guideline

Entero Voice Alarm system.

Carbon Monoxide Transmitter

For more information, please visit or call toll free at

FEC400 Series. Installation Manual

Transcription:

DCU 305 R2/R3 Troubleshooting Manual Auto-Maskin AS

Document information Document revisions Revision Update April 2003 Created Aug 2006 Added nr. 17 and 18. Sept 2008 Added nr. 19 March 2009 Added nr. 20 Copyright Auto-Maskin AS, 2016 Information given in this document may change without prior notice. This document should not be copied in any way without written permission from Auto-Maskin. Title: DCU 305 R2/R3 Troubleshooting Document article #: N/A Revision: 2 All trademarks acknowledged. Related articles Rudolf R2 User s Manual, English. Article 1009326 Rudolf R2 Configuration Software. Article 1075270 DCU 305 R2 User s Manual. Auto-Maskin AS Sophie Radichs Vei 7 N-2003 LILLESTRØM Norway Telephone (+47) 64 84 52 00 Telefax (+47) 64 84 52 12 E-mail office@auto-maskin.no Internet www.auto-maskin.no - 2 -

Table of Contents TROUBLESHOOTING... 4-3 -

Troubleshooting # Symptom Possible Cause Remedy 1 The DCU indicates a running engine but the engine is at standstill. 2 I press the start button but the engine does not start. The cranking relay K1 is not activated. 3 The remote Start/Stop/Reset functions do not work. 4 The alarm Broken Wire T44 appears. 5 The communication port P3 does not work for communication purposes, but I can still connect with Rudolf. Typically, the oil pressure switch is configured to indicate a running engine. If no rpm signal is present, it is the oil pressure signal that indicates a running engine. The switch might be connected inverted. 1) The DCU indicates a running engine. 2) The DCU has a Start Disable signal. The DCU is set to LOCAL mode. In LOCAL mode, all remote operation is disabled. 1) If terminal 44 is not connected to a relay, this alarm can appear. 2) The wire to terminal 44 is broken. 3) The coil of the relay connected to terminal 44 is broken. 1) The port is configured for logging and not for communication. 2) The ID-number is incorrect. 3) Either of the communication particulars are incorrect An alarm switch opens to activate the alarm (NC). A shutdown switch closes to activate shutdown (NO). 1) See Symptom #1. 2) Remove the Start Disable signal. Bring the DCU out of LOCAL mode. 1) In Rudolf Relays, select the tickbox Disable Alarm on Terminal 44. 2) Replace the wire. 3) Replace the relay. 1) Change the port to Communication using Rudolf. 2) Change the ID-number in the DCU (using Rudolf) or in the remote system. 3) See the Communication Manual for correct setting of the remote system. - 4 -

# Symptom Possible Cause Remedy 6 I get the Low Oil Pressure alarm when the engine has stopped. 7 I get the alarm Broken Wire Detected Tx (Where x is the terminal number). 8 The analog bargraph is empty and indicates ----. 9 The analog bargraph is full (100%). 10 When cranking, the starter disconnects too early/late. 11 The Warning LED disappeared by itself, without anyone pressing the Acknowledge button. 12 The engine has stopped but the rpm-meter still indicates a few rpm. Low Oil Pressure alarm must be disabled when stopped. Channels configured to alarm for a broken wire must have a 10k resistor connected across the switch. 1) Broken wire to the analog sensor. 2) Faulty sensor 3) An activated channel that is not in use. 1) Connection failure, with +24V connected to the 4-20mA input terminal. 2) The graph is doubled in Rudolf 1) The rpm-setting RUN Detected At is set too low/high. 2) An oil pressure switch/ sensor are used as an additional run signal, and the oil pressure appears too early. Warnings can be set to require acknowledge before disappearing. 1) Earth fault 2) Noise on power supply cables Check the tickbox Alarm on Run Only for the appropriate channel in Rudolf. Note! This goes for all pressure/flow switches. 1) Connect the10k resistor in parallel with the switch, or 2) Clear the checkbox Broken Wire Detection for that channel in Rudolf. 1) Verify the wiring. 2) Change the sensor. 3) Clear the Activate checkbox in Rudolf for the appropriate channel. 1) Verify the connections. 2) Clear the checkbox Double Scale in Rudolf. 1) In Rudolf, adjust the RUN Detected At setting. 2) In Rudolf, adjust the timer Initial Delay for the appropriate channel. In Rudolf, change the behaviour of the Warning messages by ticking the checkbox Warning Requires Acknowledge in the Main tab. 1) Check all wiring. Often, a switch is used where the shield is connected to 0V. 2) RK-66 is equipped with filters. Try different combinations of dip switches 2, 3 and 4 on RK-66. - 5 -

# Symptom Possible Cause Remedy 13 Displayed RPM is not stable, but the engine RPM is stable. 14 I press the Standby/Manual button, but the panel refuses to go to Manual. 15 When testing Primary Battery Failure by removing wires from terminal 1 and 2, the screen temporarily goes black. Is this Normal? 16 I do not get the alarm Analog Sensor Failure when the signal is 0mA. 17 Alarm led is flashing and cannot be acknowledged. 18 Common alarm does not alarm when power is lost. 19 J1939 unstable or shows only a few of many configured analog. 20 (R3 only) Diagnostic shows 65535, even if there is no actual diagnostic active in the ECM MPU signal not strong enough Terminal 61/62 is configured as Standby and activated. Normal The channel is configured for 0-20mA or 0-5V One or several Switch channels are activated in Rudolf but have no configuration. A configurable relay is used for common alarm. This Does not activate on loss of power. Bad connection in J1939 cable or incorrect cable type. Firmware related. Remove the MPU and check for dirt. Connect and verify that signal strength is at least 2.5VAC. Reconfigure None. Increase signal strength or configure as 4-20mA. Open the Rudolf configuration software, and then deactivate channels not in use. Use the dedicated common alarm relay K5. Disconnect power!! Disconnect cable on P10 and check for ~120 Ohm resistance on cable-d-sub Pin 7 and 2. If OK, then check for 120 Ohm on DCU 305 s Port P10 pin 7 and 2. Update DCU 305 R3 firmware. - 6 -